Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAMMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

[Value of MR tomography in inconclusive mammography findings].

PURPOSE: To evaluate the usefulness of magnetic resonance (MR) imaging in the assessment of inconclusive findings at mammography, such as indeterminate focal or diffuse breast abnormalities, post-treatment breasts with extensive scarring, dense breasts, and findings suggesting multifocal or multicentric breast cancer. MATERIAL AND METHODS: 254 patients underwent mammography, sonography, and MRI of the breast. Dynamic MR imaging was done using a thin-section three-dimensional gradient-echo sequence (FLASH, TR = 11.8 ms; TE = 5 ms; flip angle = 25 degrees) which was applied in a dynamic fashion before and every 90 seconds after injection of gadopentetate dimeglumine. Diagnoses were confirmed at biopsy (n = 165) or by follow-up (n = 89). RESULTS: Among various breast anomalies, the highest proportion of breast cancers was associated with dense breast tissue (27.8%), architectural distortion (26.9%), and irregular scars (15.8%). Sensitivity of dynamic MR imaging was 93.7%, and specificity was 83.3%. As compared to mammography and sonography, MR detected 6 occult carcinomas, and showed additional malignant lesions in 19/63 women (30.2%) with biopsy-proven breast cancer. CONCLUSION: MR imaging of the breast may provide valuable additional information in indeterminate breast anomalies. However, because of its inherent limitations, it should not replace core needle biopsy in all lesions which are amenable to biopsy. Because of its high sensitivity in the detection of invasive carcinomas in any type of breast tissue, MR imaging is considered the modality of choice in the evaluation of dense breasts in high-risk patients or in patients with clinical suspicion of occult breast cancer, and for preoperative tumor staging.

Breast↗

Value of contralateral surveillance mammography for primary breast cancer follow-up.

Mammographic screening of the contralateral breast is often advocated during follow-up of women previously treated for primary operable breast cancer. The purpose of this study was to determine the value of this investigation. Between 1987 and 1995 a total of 5102 contralateral screening mammograms were performed biennially on 2511 women aged </= 70 years following treatment for primary operable breast cancer. Sixty-five metachronous contralateral breast cancers were identified: 21 (32%) at routine clinical examination, 24 (37%) at mammography, and 20 (31%) by patients between routine follow-up appointments. The prognostic features of metachronous cancers were better or similar to those of the first cancer in 59 of 65 (91%) cases. Because of the favorable prognostic characteristics of the contralateral cancer, mammographic screening may have contributed to the long-term survival of 16 of 26 women in whom the histologic characteristics of the first cancer predicted a good prognosis. The cancer detection rate with mammography for these women was 6.5 per 1000 contralateral mammogram investigations at a cost of pound3852 per cancer detected. The results of this study suggest that surveillance mammography of the contralateral breast is of value in women whose first cancer predicted a favorable prognosis.

Adult↗

Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen-film mammography: results of a prospective clinical trial.

The purpose of the study was to determine prospectively the diagnostic value of a computed radiography (CR) system by comparing mammographic hard copy images with screen-film mammography (SFM). A series of 100 patients, who came for diagnostic investigation, underwent two-view SFM (Lorad M-IV Platinum) and digital mammography with a CR system (AGFA CR system). The images were obtained by double exposure, i.e. same view without removing compression of the corresponding breast. The CR images were processed with dedicated processing for mammography. Six radiologists read sets of SFM and CR images. The primary efficacy parameter was the overall diagnostic value. The secondary efficacy parameters were lesion conspicuity and lesion details (for masses and micro-calcifications), tissue visibility at chest wall and at skin line, axillary details, overall density and sharpness impression and the overall noise impression. These parameters were scored by a 7-point scoring system. "CR non-inferior to SFM" was concluded if the lower confidence interval bound exceeded 80%. The confidence interval for the overall diagnostic value was between 96.4% and 100%. Pooled analysis of the ten features for image quality comparison demonstrated for all but one feature (lesion details of the calcifications) CR non-inferiority to SFM.

Adult↗

Digital mammography: current state and future aspects.

The introduction of digital technique in mammography has been the last step in completing the process of digitalization in diagnostic imaging. Meanwhile, some different digital techniques as well as a couple of different digital mammography systems were developed and have already been available for some years. In this review article, the relevant data of key studies are reported, the current status is defined, and perspectives of digital mammography are described.

Breast Neoplasms↗

Effect of soft-copy display supported by CAD on mammography screening performance.

Diagnostic performance and reading speed for conventional mammography film reading is compared to reading digitized mammograms on a dedicated workstation. A series of mammograms judged negative at screening and corresponding priors were collected. Half were diagnosed as cancer at the next screening, or earlier for interval cancers. The others were normal. Original films were read by fifteen experienced screening radiologists. The readers annotated potential abnormalities and estimated their likelihood of malignancy. More than 1 year later, five radiologists reread a subset of 271 cases (88 cancer cases having visible signs in retrospect and 183 normals) on a mammography workstation after film digitization. Markers from a computer-aided detection (CAD) system for microcalcifications were available to the readers. Performance was evaluated by comparison of A(z)-scores based on ROC and multiple-Reader multiple-case (MRMC) analysis, and localized receiver operating characteristic (LROC) analysis for the 271 cases. Reading speed was also determined. No significant difference in diagnostic performance was observed between conventional and soft-copy reading. Average A(z)-scores were 0.83 and 0.84 respectively. Soft-copy reading was only slightly slower than conventional reading. Using a mammography workstation including CAD for detection of microcalcifications, soft-copy reading is possible without loss of quality or efficiency.

Aged↗

Patient satisfaction and quality of care at four diagnostic imaging procedures: mammography, double-contrast barium enema, abdominal ultrasonography and vaginal ultrasonography.

The objective of this study was to measure patient satisfaction and to investigate the practical implications of monitoring the quality of care at four radiology procedures. A survey was conducted immediately after the examinations in eight radiology departments: 550 patients attending for mammography, 110 for double-contrast barium enema (DCBE), 97 for abdominal ultrasonography and 90 for vaginal ultrasonography. Outcome measures were seven questionnaire scales: pain, emotional distress, information received, staff's punctuality and technical ability, facilities, and general satisfaction. Response rate was 87 %. Multivariate regression analysis showed significant differences between procedures on all scales (p < 0.001). Differences considered to be of practical importance, i. e. >/= 7 scale points, were detected on five of the scales. Mammography and DCBE caused the most pain, and vaginal US and DCBE caused the most distress. The US procedures entailed dissatisfaction with information about the procedures. The DCBE patients recorded dissatisfaction with the staff's lack of punctuality, and these and the mammography patients recorded dissatisfaction with the facilities. The findings indicate a potential for improving patients' experiences. Several aspects of care, i. e. pain management, attention to the patient's emotional concerns, explanation of procedures, punctuality and quality of the facilities, can be improved.

Abdomen↗

Differentiation between benign and malignant findings on MR-mammography: usefulness of morphological criteria.

The purpose of this study was to evaluate the usefulness of morphological criteria in differentiating between benign and malignant lesions on MR-mammography. Fifty-three women (18-82 years) with 62 lesions scheduled for excisional biopsy underwent dynamic contrast-enhanced MR-mammography using fast 3D Gradient-Echo sequences in coronal orientation (axial orientation in seven patients). Histology revealed 44 malignant and 18 benign lesions. For each lesion, five radiologists evaluated four morphological features: lesion shape, irregularity of contour, homogeneity of contrast enhancement and presence of ring enhancement. For each feature a receiver operating characteristic (ROC) curve was generated with calculation of the area under the curve (AUC). Interobserver variability was evaluated by the kappa-coefficient. The most reliable morphological feature indicating malignancy was an irregular lesion contour with a sensitivity/specificity/AUC of 83%/76%/0.9 followed by inhomogeneous contrast enhancement (85%/42%/0.7) and the presence of ring enhancement (71%/53%/0.64). The average interobserver agreement for the different features ranged between 0.35 and 0.4. Morphological criteria are useful features in MR-mammography for differentiating between benign and malignant lesions. However, due to the relatively high interobserver variability, standardization of terminology is important.

Adolescent↗

Soft copy versus hard copy reading in digital mammography.

The objective of this study was to compare soft copy reading at a mammography work station with hard copy reading of full-field digital mammographic images. Mammograms of 60 patients ( n = 29 malignant, n = 31 benign) performed with full-field digital mammography (Senographe 2000D, GE, Buc, France) were evaluated. Reading was performed based on hard copy prints (Scopix, Agfa, Leverkusen, Germany) and on 2 k x 2.5 k high-resolution monitors (Sun Ultra 60, Sun Microsystems, Palo Alto, California, USA). Four readers with different levels of experience in mammography categorized the mammograms according to the BI-RADS classification. The comparative study was performed by four readers, and at least 2 months elapsed between the reading sessions. Postprocessing, of course, was available only at the work station (windowing and leveling, zooming, inversion). Sensitivity, specificity, and positive predictive value were evaluated. Diagnostic accuracy of the evaluation was determined. Sensitivity for malignant lesions in hard copy versus soft copy reading was 97% vs 90%, 97% vs 97%, 93% vs 97%, and 76% vs 76% for the four readers, respectively. Specificity was 52% vs 68%, 58% vs 74%, 65% vs 48%, and 61% vs 68%. Accuracy for the classification of malignant lesions according to the BI-RADS categories showed no difference between hard copy and soft copy reading. Soft copy reading is possible with the available system and enables radiologists to use the advantages of a digital system.

Breast Neoplasms↗

Population-based mammography screening results in substantial savings in treatment costs for fatal breast cancer.

AIMS: The aim was to assess the effect of population-based mammography screening on treatment costs for fatal breast cancer in Turku, Finland. MATERIALS AND METHODS: The study included 556 women with invasive breast cancer, diagnosed at the age of 40-74 years in 1987-1993: 427 in the screened group (screen-detected or interval cancer) and 129 in the unscreened group (not yet invited or refused screening). Both groups were followed up for 8 years from diagnosis. RESULTS: In the unscreened group, 32 (25%) patients died of breast cancer versus 49 (12%) in the screened group (p < 0.001). The non-discounted mean treatment costs were 2.8-fold for those dying of breast cancer compared to survivors: 26,222 euros versus 9,434 euros; the difference between means was 16,788 euros (95% CI 14,915-18,660) (p<0.001). The mean costs for fatal cases were high, irrespective of the way cancer was detected: 23,800 euros in the unscreened group versus 27,803 euros in the screened group; the difference between means was -4,003 euros (-10,810 to 2802) (p=0.245). In the unscreened group, patients with fatal breast cancer accounted for 41% (0.76/1.87 million euros) of the total treatment costs versus 29% (1.36/4.76 million euros) in the screened group. It was estimated that about one third of costs for fatal breast cancer were avoided through mammography screening, accounting for 72-81% of the estimated total treatment cost savings achieved by screening. About 31-35% of the screening costs for 1987 to 1993 were offset by savings in treatment costs. CONCLUSIONS: Treatment costs for fatal breast cancer are high. Mammography screening results in substantial treatment cost savings, in which reduction of fatal disease is the key element.

Adult↗

Assessing the impact of screening mammography: Breast cancer incidence and mortality rates in Connecticut (1943-2002).

BACKGROUND: Randomized controlled studies demonstrate that early detection and intervention reduce breast cancer mortality by approximately 25%. Though the ultimate goal of screening is to reduce breast cancer deaths, the immediate goal is to detect and treat early-stage tumors before they pose a threat to life. MATERIALS AND METHODS: To assess the impact of early detection and intervention in the general population, we analyzed breast cancer incidence and mortality rates in the NCI's Historical Connecticut Tumor Registry (1943-2002). RESULTS: Though breast cancer rates increased for the entire study period, overall incidence rates rose faster than previously following the initiation of mammography screening in the early 1980s in the United States. Of note, stage-specific incidence rates increased 152% (53.2-133.9 per 100,000 woman-years) for early-stage tumors and fell 16% (56.1-47.2 per 100,000 woman-years) for late-stage breast cancers. Period- and cohort-age-specific incidence rates rose dramatically for early-stage tumors among women targeted for screening (ages 40-80 years), whereas rates for regional and distant stages declined modestly among women ages >50 years. Breast cancer mortality rates fell 31.6%. CONCLUSIONS: Along with increases in incidence rates for early-stage tumors, rates for late-stage disease and breast cancer mortality declined following widespread screening mammography, consistent with effective early detection and improved treatment over time. However, the disparity between the dramatic rise in early-stage tumors compared to the more modest declines in late-stage disease and mortality suggests that many mammography-derived early-stage lesions may never progress to late-stage cancers and pose a threat to life.

Adult↗

Contrast-enhanced magnetic resonance mammography: does it affect surgical decision-making in patients with breast cancer?

BACKGROUND: Diagnostic imaging in women with suspected breast cancer should accurately detect and diagnose malignant tumors and facilitate the correct choice of therapy. Contrast-enhanced magnetic resonance mammography (CE-MRM) is potentially the imaging modality of choice for accurate patient management decisions. METHODS: A total of 164 women with suspected breast cancer based on clinical examination, conventional mammography and/or ultrasound each underwent preoperative bilateral CE-MRM using an axial 3D dynamic T1-weighted gradient-echo sequence and gadobenate dimeglumine as contrast agent. Images were evaluated by two readers in consensus. Histological evaluation of detected lesions was performed on samples from core biopsy or surgery. Determinations were made of the sensitivity, accuracy and positive predictive value of CE-MRM compared to mammography/ultrasound for the detection of malignant lesions and of the impact of CE-MRM for surgical decision-making. FINDINGS: Conventional mammography/ultrasound detected 175 lesions in the 164 evaluated patients. CE-MRM revealed 51 additional lesions in 34/164 patients; multifocal and multicentric cancer was detected in 7 and 4 additional patients, respectively, contralateral foci in 21 additional patients and pectoral muscle infiltration in 2 additional patients. CE-MRM also confirmed the absence or benignity of 3 and 1 lesions suspected of malignancy on mammography/ultrasound. The sensitivity and accuracy for malignant lesion detection and identification was 100% and 93.4%, respectively, for CE-MRM compared to 77.3% and 72.1% for mammography/ultrasound, respectively. Patient management was altered for 32/164 (19.5%) patients as a result of CE-MRM. INTERPRETATION: CE-MRM positively impacts patient management decisions and should be performed in all women with suspected breast cancer based on clinical examination, mammography and/or ultrasound.

Adult↗

Variation in screening mammography and Papanicolaou smear by primary care physician specialty and gatekeeper plan (United States).

OBJECTIVE: To assess whether the specialty of a patient's primary care physician or being part of a gatekeeper plan influence breast and cervical cancer screening. METHODS: Cross-sectional study of women in a national sample. For mammography, we studied women aged 40 and above, and for Papanicolaou (Pap) smear, women aged 18-65 years. Screening mammography or Pap smear within the previous two years was measured by patient self-report. The key independent variables were primary care physician specialty and whether the patient had a gatekeeper. RESULTS: Among women seen by a family practice physician, there was a higher probability of being screened if the patient was part of a gatekeeper plan than if the patient was not part of a gatekeeper plan: mammography (OR = 1.35; 95% CI = 1.20-1.52) and Pap smear (OR = 1.60; 95% CI = 1.34-1.91). Among women seen by an internal medicine physician, cancer screening did not vary significantly by gatekeeper status. CONCLUSIONS: The impact of gatekeeper plans upon cancer screening varies according to the primary care physician's specialty. Policy interventions designed to increase cancer screening should take into account different responses to gatekeeper requirements among different types of providers.

Adolescent↗

Benefit of screening mammography in reducing the rate of late-stage breast cancer diagnoses (United States).

OBJECTIVE: We studied the benefit of modern mammography screening in community settings, evaluating age-related differences in rates of late-stage breast cancer detection. METHODS: Our multicenter population-based case-control study included 931 black and white women with incident breast cancer (American Joint Commission on Cancer Stage IIB or higher) diagnosed 1994-1998 and 4,016 randomly sampled controls never diagnosed with breast cancer. Adjusted odds ratios (ORs) estimated the relative rate of late-stage diagnosis in screened and non-screened women. RESULTS: Women aged 50-64 at diagnosis with at least one screening mammogram in the previous 2 years were significantly less likely to have late-stage diagnosis (OR = 0.41, 95% CI 0.33-0.52). Results for women aged 40-49 were consistent with a screening benefit, although the confidence interval marginally overlapped the null (OR = 0.81, 95% CI 0.64-1.02). Mammography screening was associated with lower rates of late-stage breast cancer among both premenopausal (OR = 0.64, 95% CI 0.50-0.81) and postmenopausal (OR = 0.44, 95% CI 0.35-0.56) women. CONCLUSIONS: With modern mammography in the community, rates of late-stage breast cancer diagnoses are lower in screened compared to non-screened women ages 40 and older, but age-related differences persist.

Adult↗

Meeting the mammography screening needs of underserved women: the performance of the National Breast and Cervical Cancer Early Detection Program in 2002-2003 (United States).

OBJECTIVE: To examine the extent to which the National Breast and Cervical Cancer Early Detection Program (Program) has helped to meet the mammography screening needs of underserved women. METHODS: Low-income, uninsured women aged 40-64 are eligible for free mammography screening through the Program. We used data from the U.S. Census Bureau to estimate the number of women eligible for services. We obtained the number of women receiving Program-funded mammograms from the Program. We then calculated the percentage of eligible women who received mammograms through the Program. RESULTS: In 2002-2003, of all U.S. women aged 40-64, approximately 4 million (8.5%) had no health insurance and had a family income below 250% of the federal poverty level, meeting Program eligibility criteria. Of these women, 528,622 (13.2%) received a Program-funded mammogram. Rates varied substantially by race and ethnicity. The percentage of eligible women screened in each state ranged from about 2% to approximately 79%. CONCLUSIONS: Although the Program provided screening services to over a half-million low-income, uninsured women for mammography, it served a small percentage of those eligible. Given that in 2003 more than 2.3 million uninsured, low-income, women aged 40-64 did not receive recommended mammograms from either the Program or other sources, there remains a substantial need for services for this historically underserved population.

Adult↗

Pain and discomfort associated with mammography among urban low-income African-American women.

African-American women have lower rates of breast cancer screening than Caucasian women. Discomfort during mammography may deter women from rescreening. Research to date has focused primarily on Caucasian women. This study examined mammography-associated discomfort among urban, low-income African-American women, and how discomfort influenced rescreening intentions. Using survey data from 530 urban African-American women aged 45 years and older, we assessed sociodemographic, psychological, and health-related predictors of pain or discomfort, and associations between pain or discomfort and intention for rescreening. Seventy-six percent of women reported discomfort; reasons included machine compression (96%), breast size (36%), stature (30%), and roughness by technicians (18%). Intention to rescreen within 2 years was significantly reduced with reporting any discomfort (OR 0.61; 95% CI: 0.38, 0.98), reporting two specific reasons-stature (OR 0.47; 95% CI: 0.31, 0.72) and technician roughness (OR 0.43; 95% CI: 0.26, 0.72), and attributing more sources for pain or discomfort (p for trend = 0.02). Most women reported discomfort; for some, this influenced intended adherence. Offering women the opportunity to control the amount of compression may reduce the pain associated with mammography and subsequently increase compliance.

Black or African American↗

Analysis of the results of a proficiency test in screening mammography at the CSPO of Florence: review of 705 tests.

PURPOSE: The aim of this study was to evaluate the performance of a sample of Italian radiologists undergoing a proficiency test of screening mammography. MATERIALS AND METHODS: We retrospectively analysed the results of 705 tests (537 first tests, 168 repeat tests) taken during 1997-2005 by 537 Italian radiologists. The test, consisting of 17 screen-detected cancer cases and 133 negative controls, was validated by a panel of expert readers defining a minimum standard as to sensitivity for cancer and recall rate of negative controls. Success rates were assessed as a function of previous experience in mammography (years of experience, total mammograms read, mammograms read in the last year). RESULTS: A total of 176 radiologists successfully passed the test at their first attempt (32.7%). Success correlated with experience, measured in terms of years of experience (5-year cutoff: chi(2) for trend=4.17, p=0.04), total mammograms read (chi(2) for trend =11.8, p=0.002) or mammograms read in the last year (chi(2) for trend=6.27, p=0.04). Training improves performance at repeat testing: after a first negative attempt, a second attempt was successful in 50.6% of cases (74/146) and a third in 68.1% (15/22). CONCLUSIONS: A substantial proportion of Italian radiologists taking the test showed limited proficiency in screening mammography. This finding is consistent with several reports of poor performance of service screening compared with reference standards. As expected, test performance is associated with experience, suggesting that the current policy of employing non-dedicated, untrained, general radiologists in screening should be reconsidered. Test performance improves with training (courses, consultation of teaching atlases). Several screening programmes in Italy have been implemented without prior adequate radiologist training. Radiologist training needs to be considered a priority, at least in those screening programmes that are still to be implemented in one third of the country.

Aged↗

Impact of mammography on breast surgery in a small community hospital.

The impact of mammography on breast surgery at a small community hospital was evaluated by comparing the stage of cancer at diagnosis in a 5 year period before mammography with that in a 5 year period after its introduction. During both periods approximately the same number and stage of palpable carcinomas were diagnosed and treated. However, in the 5 year period after introduction of mammography, in addition to the 35 palpable carcinomas 11 additional nonpalpable occult carcinomas were diagnosed. These 11, with an average size of 8 mm and all in patients with negative nodes, would fit into the category of minimal breast cancer, which is associated with a 10 year disease-free interval of over 90 percent.

Aged↗

Audit of mammography in a community setting.

A Northwest community concentrated all mammography services in one location and instituted a program of annual review. The 32,118 mammograms prompted 466 biopsies of women who had no palpable abnormality. Over the 5-year study, there were 142 nonpalpable cancers found for a positive biopsy rate of 30%. In the first year, the positive biopsy rate was 17%, and, in the last year, it was 42%. The increase in apparent selectivity prompted a search for false negatives or missed breast cancers. One percent of women subjected to mammography underwent biopsy, but, interestingly, only 84% of women undergoing mammography received a normal report. Eighty-seven percent of the cancers were invasive, and 13% were considered to be noninvasive. A review of the literature suggests significant variation in the frequency of identifying nonpalpable breast cancer, and respected pathologists report variations in the pathologic evaluation of these nonpalpable cancers.

Adult↗