Radiation exposure reduction during voiding cystourethrography in a pediatric porcine model of vesicoureteral reflux.

PURPOSE: To compare grid-controlled variable-rate pulsed fluoroscopy (GCPFL) and continuous fluoroscopy (CFL) for the reduction of radiation exposure during voiding cystourethrography (VCUG) in a pediatric porcine model of vesicoureteral reflux. MATERIALS AND METHODS: Institutional animal care and use committee approval was obtained. Vesicoureteral reflux was simulated in four pigs, and 48 VCUG studies were performed (24 with GCPFL, 24 with CFL). VCUG was performed at abdominal girths of 8-10 cm (group 1, simulates human newborn to 6-month-old infant), 12-13 cm (group 2, simulates 2-3-year-old child), and 15-17 cm (group 3, simulates 10-year-old child). An electronic device calculated total radiation exposure during fluoroscopy and image recording. With five-point ordinal scales, VCUG images were scored independently for anatomic conspicuity and overall diagnostic quality by two radiologists (radiologists A and B). An analysis of variance was used to compare radiation exposures and fluoroscopy times between GCPFL and CFL and to determine whether radiation exposure and fluoroscopy time were dependent on the pig's abdominal girth. The Pearson product-moment correlation coefficient was used to assess whether fluoroscopy time was correlated with radiation exposure. Anatomic conspicuity and diagnostic quality scores were compared by means of the Wilcoxon signed rank test. RESULTS: Results of analysis of variance revealed that GCPFL resulted in a significant reduction in total radiation exposure compared with CFL for each of the three groups (P < .05 for each comparison), and this reduction was most marked in the larger animals. There were no significant differences in diagnostic quality of the recorded VCUG images (P > .05). Anatomic conspicuity was not significantly different for groups 2 and 3, but there was a significantly higher score for GCPFL in group 1 for radiologist A (P = .04). CONCLUSION: By using GCPFL in the performance of VCUG in a pediatric porcine model of vesicoureteral reflux, total radiation exposure can be reduced by a factor of 4.6-7.5 lower than with CFL, and diagnostic-quality images can be obtained.

Analysis of Variance↗

Radiation exposure during catheter ablation of atrial fibrillation.

BACKGROUND: The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach. METHODS AND RESULTS: The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray system operated at a low-frame pulsed fluoroscopy (7.5 frames per second). Radiation exposure was measured directly with 50 to 60 thermoluminescent dosimeters (TLDs). Peak skin doses (PSDs), effective radiation doses, and risk of fatal malignancies were all computed. Mean fluoroscopy durations for AF procedures were 67.8+/-21 minutes in the right anterior oblique (RAO) and 61.9+/-16.6 minutes in the left anterior oblique (LAO) projection, significantly different from that required for atrial flutter and AVNRT. The mean PSDs measured with the TLDs were 1.0+/-0.5 Gy in the RAO and 1.5+/-0.4 Gy in the LAO projection. The lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy was 0.07% for women and 0.1% for men. CONCLUSIONS: The relatively small amounts of the patient's radiation exposure in this study, despite the prolonged fluoroscopy durations, can be attributed to the use of very-low-frame pulsed fluoroscopy, the avoidance of magnification, and optimal adjustments of the fluoroscopy exposure rates. The resulting lifetime risk of fatal malignancy is within the range previously reported for standard supraventricular arrhythmias.

Adult↗

Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: A prospective randomized study.

BACKGROUND: Radiofrequency catheter ablation within the tricuspid annulus-inferior caval vein isthmus can cure typical atrial flutter. The target for ablation, nonetheless, is relatively wide, and standard ablation procedures may require significant exposure to radiation. METHODS AND RESULTS: A total of 50 patients (mean age, 58+/-11 years) with typical atrial flutter were prospectively randomized to receive isthmus ablation using conventional fluoroscopy for catheter navigation (group I, n=24) or electromagnetic mapping (group II, n=26). Complete bidirectional isthmus block was verified with double potential mapping. If complete isthmus block could not be achieved after 20 radiofrequency pulses or 25 minutes of fluoroscopy, the patients were switched to the other group. Eight patients from group I (33%) but only 1 patient from group II (4%) were switched. Overall, complete isthmus block was achieved in 47 of 50 patients (94%). The overall fluoroscopy time, including the placement of the diagnostic catheters, was 22.0+/-6.3 minutes in group I and 3.9+/-1.5 minutes in group II (P:<0.0001). The fluoroscopy time needed for isthmus mapping was 17.7+/-6.5 minutes in group I and 0.2+/-0.3 minutes in group II (P:<0.0001). CONCLUSIONS: Electromagnetic mapping during the induction of linear lesions for the ablation of atrial flutter permitted a highly significant reduction in exposure to fluoroscopy while maintaining high efficacy, and it allowed the time required for fluoroscopy to be reduced to levels anticipated for diagnostic electrophysiological studies.

Atrial Flutter↗

Computer assisted determination of the dose-area product in retrograde urethrography.

Retrograde urethrography (RUG) is a dynamic radiological procedure in which the cumulative dose-area product (DAP) comprises radiation doses derived from both fluoroscopy and radiography. In the present prospective study, digital retrograde urethrographs (Prestilix 1600X/DRS, General Electric) were obtained in 40 consecutive male patients (mean age 60.6 years; range 23-88 years) presenting for evaluation of urinary pathology. The radiation dose was recorded as the dose-area product. From these data, a computer program (Diasoft 2.0, PTW, Freiburg, Germany) then determined the respective proportions of the total radiation dose deriving from fluoroscopy and radiography, as well as the number of radiographic exposures. The average total radiation dose was 316 cGy cm2. In five of the 40 patients examined (12.5%), the number of radiographic exposures registered by the program and, hence, the calculated DAPs were erroneous. In the remaining 35 patients, the average proportion of the cumulative DAP resulting from fluoroscopy was 81%, while that deriving from radiography was 19%. The computer program utilized in this study makes possible an intelligent evaluation of the DAP in dynamic procedures such as RUG. Since fluoroscopy is responsible for 81% of the cumulative DAP at RUG, a significant decrease in applied radiation dose may be achieved by reducing fluoroscopy time or by using pulsed fluoroscopy.

Adult↗

Computer-assisted LISS plate osteosynthesis of proximal tibia fractures: feasibility study and first clinical results.

Fluoroscopy is the most common tool for the intraoperative control of long-bone fracture reduction. Limitations of this technology include high radiation exposure for the patient and the surgical team, limited visual field, distorted images, and cumbersome verification of image updating. Fluoroscopy-based navigation systems partially address these limitations by allowing fluoroscopic images to be used for real-time surgical localization and instrument tracking. Existing fluoroscopy-based navigation systems are still limited as far as the virtual representation of true surgical reality is concerned. This article, for the first time, presents a reality-enhanced virtual fluoroscopy with radiation-free updates of in situ surgical fluoroscopic images to control metaphyseal fracture reduction. A virtual fluoroscopy is created using the projection properties of the fluoroscope; it allows the display of detailed three-dimensional (3D) geometric models of surgical tools and implants superimposed on the X-ray images. Starting from multiple registered fluoroscopy images, a virtual 3D cylinder model for each principal bone fragment is constructed. This spatial cylinder model not only supplies a 3D image of the fracture, but also allows effective fragment projection recovery from the fluoroscopic images and enables radiation-free updates of in situ surgical fluoroscopic images by non-linear interpolation and warping algorithms. Initial clinical experience was gained during four tibia fracture fixations that were treated by LISS (Less Invasive Stabilization System) osteosynthesis. In the cases operated on, after primary image acquisition, the image intensifier was replaced by the virtual reality system. In all cases, the procedure including fracture reduction and LISS osteosynthesis was performed entirely in virtual reality. A significant disadvantage was the unfamiliar operation of this prototype software and the need for an additional operator for the navigation system.

Adult↗

[Trial of finger contamination reduction of the operator in nerve block treatment: comparison of over- and under-table systems].

Fluoroscopy-guided intervention of the lumbar spine, such as nerve block, plays an important role in the management of disc hernia patients. However, irradiation of operators' fingers remains a problem even with careful collimation and operation, especially when performed by non-radiologists. We compared the irradiation doses of under-table and over-table fluoroscopy systems, and we discuss the most advantageous method of reducing irradiation. The effectiveness and conditions of use of lead protection gloves were also evaluated. Skin dose was monitored using polymethyl methacrylate (PMMA) and an electronic dose meter. The skin doses of over- and under-table fluoroscopy were compared using C-arm fluoroscopy. Finger irradiation dose with 0.03 mmPb protection gloves was also measured. The under-table method reduced skin dose by 95% compared with the over-table method. Thicker PMMA resulted in a higher rate of irradiation reduction. Protection gloves reduced radiation dose by half, although this reduction was cancelled when automatic brightness control (ABC) was utilized. Under-tube fluoroscopy was superior to over-tube fluoroscopy in reducing irradiation to the fingers.

Fingers↗

The importance of fluoroscopic guidance for Maloney dilation.

One hundred and forty-five patients were evaluated for the importance of fluoroscopic monitoring during Maloney esophageal dilation. In 35 patients (24%), fluoroscopy altered the dilation technique. Dilation of peptic strictures (27 of 75, 36%) was much more likely to be affected by fluoroscopy than Schatzki's rings (eight of 70, 11%, p < 0.05). Patients whose stricture was altered by fluoroscopy also had larger size hiatal hernias (6.5 vs. 4.3 cm, p < 0.05). Patients with Schatzki's ring with a hiatal hernia size of less than or equal to 4.0 cm did not benefit from fluoroscopy. In 26 of 35 cases, successful redirection of the dilator and passage under fluoroscopy was accomplished. In nine patients, Maloney dilation was impossible, and use of Savary wire-guided dilators was needed. We had no morbidity and mortality. We advise the use of fluoroscopy for Maloney dilation for peptic strictures and for large hiatal hernias.

Adolescent↗

Safety of transvenous right ventricular endomyocardial biopsy guided by two-dimensional echocardiography.

A total of 231 endomyocardial biopsy procedures performed in 74 consecutive patients were evaluated to compare the incidence and nature of complications in procedures guided by fluoroscopy versus those guided by echocardiography. Sixty biopsy procedures were guided by fluoroscopy and 171 by two-dimensional echocardiography. The right interventricular septum was the target site for biopsy sampling in all patients. Clinical signs of myocardial perforation occurred during one (1.7%) procedure guided by fluoroscopy versus two (1.2%) procedures guided by echocardiography. Two cases of interventricular septal perforation were visualized during the echo-guided procedures. The biopsy specimens were judged to be inadequate for diagnosis in 2.2% of the biopsy procedures, all of which were guided by fluoroscopy. The number of samples obtained during a procedure guided by fluoroscopy was lower (mean 2.3 +/- 1.6) (mean +/- 1 SD) than that taken during a procedure guided by echocardiography (mean 4.0 +/- 1.2). Epicardial or pericardial tissue was present in 5.8% of the samples obtained under fluoroscopic guidance, versus 0.7% of the samples obtained using echocardiography (p = 0.0003). It is concluded that although echocardiography seems to provide more accurate and safer guidance for the positioning of the bioptome toward the septum, the presence of epicardium or pericardium in 0.7% of the samples indicates that inadvertent sampling from the right ventricular free wall cannot be avoided.

Adolescent↗

Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study.

INTRODUCTION: The objective of this clinical trial was to determine whether there is a skill dependence for the total amount of radiation exposure to orthopaedic surgeons caused by fluoroscopy during intramedullary fracture fixation. MATERIALS AND METHODS: Surgical teams were assigned to either the 'Senior group' or the 'Junior group' according to their professional qualification and clinical appointment. Twenty-two long-bone shaft fractures were stabilized with intramedullary nails. The radiation exposure was measured at different body locations including fingers, trunk and head by means of thermoluminescent LiF:Mg,Cu,P detectors. The total time of fluoroscopy was registered for each operation. RESULTS: Mean time of fluoroscopy per operation was 4.43 min for the 'Senior group' and 6.95 min for the 'Junior group'. The surgeons' hands were exposed to markedly higher doses (range 0-2.88 mSv 'Senior group'; 0-11.94 mSv 'Junior group') than their trunk and head (range 0-0.27 mSv 'Senior group'; 0-0.38 mSv 'Junior group'). After analysis of variance, differences between both groups proved to be statistically significant for all fingers measured (p</=0.02) and for the total time of fluoroscopy (p=0.019). CONCLUSIONS: Generally, the hands are at higher risk than are the trunk and the head, and this finding is independent of surgical skills. However, an additional hazard is created for the less experienced surgeon by a highly varying and poorly predictable exposure of the hands and time needed for fluoroscopy. Thus, the use of radiation is more consistent and standardized with a skilled surgeon.

Clinical Competence↗

Comparison of film-screen combination and digital fluorography in gastrointestinal barium examinations in a clinical setting.

OBJECTIVE: Digital fluoroscopy systems have been developed for gastrointestinal barium studies. We compare the performance of a commercially available digital fluoroscopy system with conventional film-screen combinations in gastrointestinal barium studies. METHODS: Two consecutive groups of outpatients underwent diagnostic barium examinations of esophagus, stomach, or colon using either a film-screen technique (n = 32) or a digital fluoroscopy system with an 8-bit gray scale (n = 31). A standardized biphasic protocol was employed in all patients by the same set of investigators and scored subjectively for contrast performance in single-contrast and double-contrast mode and for spatial resolution. RESULTS: For the whole group there were no significant differences between the two techniques. In the subgroup of esophagus studies, digital fluoroscopy performed better during the full-column part of the examination. In the subgroup of colon studies, the film-screen technique performed better during the double-contrast part of the examination. To reach sufficient spatial resolution with the digital system (884(2) matrix), the smallest input screen had to be used (23 cm), resulting in a higher number of exposures than with the film-screen combination (P = 0.006). The average amount of film used was not significantly different. CONCLUSION: In a clinical setting the contrast performance and spatial resolution of digital fluoroscopy systems can be comparable with conventional film-screen combinations.

Barium Sulfate↗

Safety and efficacy of ERCP in pregnancy.

BACKGROUND: Choledocholithiasis during pregnancy increases the risk of morbidity and mortality for both fetus and mother because of cholangitis and pancreatitis. ERCP has been advocated as safe and effective in pregnant women, but fetal radiation exposure is not routinely monitored. The aim of this study was to record fetal exposure to ionizing radiation during ERCP and to assess outcome. METHODS: Seventeen ERCPs were performed in pregnant women between January 1995 and August 2003. Techniques to minimize fluoroscopy were used, and fluoroscopy times were recorded. Thermoluminescent dosimeters affixed to the skin of the mother were used to estimate fetal radiation exposure. OBSERVATIONS: Mean gestational age was 18.6 (8.9) weeks (range 5-33 weeks). Mean fluoroscopy time was 14 (13) seconds (range 1-48 seconds). Estimated fetal radiation exposure was 40 (46) mrad (range 1-180 mrad). There was a correlation between fluoroscopy time and radiation exposure, but there was a wide range of radiation exposure for individual fluoroscopy times. Complications included post-sphincterotomy bleeding in one patient (controlled by hemoclip placement) and post-ERCP pancreatitis in one patient that necessitated 3 days of hospitalization. Two women developed third-trimester preeclampsia, and labor was induced in both. Thirteen of the 15 patients who delivered were contacted and they confirmed that their child was in good health. CONCLUSIONS: ERCP with modified techniques is safe during pregnancy. Dosimetry should be routinely recorded.

Adolescent↗

Radiation exposure to patients and personnel during interventional ERCP at a teaching institution.

BACKGROUND: This study was designed to determine the radiation dose to patients and personnel during ERCP procedures. METHODS: Phantom studies were performed to compare dosimetry for two image capture systems and to determine the effectiveness of shielding in reducing stray radiation. Radiation techniques and dosimetry were recorded in 72 patients undergoing ERCP. RESULTS: Phantom studies indicated that increasing fluoroscopy voltage from 75 to 96 kV decreased entrance dose by 50%. Image capture by digital radiography decreased radiation exposure by 66%. Shielding decreased stray radiation exposure by 93%. All patients underwent cholangiography (n = 71) and/or pancreatography (n = 53). The mean number of interventional ERCP procedures performed per patient was 1.8 (range, 0 to 6). The mean measured patient entrance dose was 80 mGy (8 R; range, 0.2 to 73 R); however, the calculated mean entrance dose (based on measured intensifying screen doses) may have been as high as 3000 mGy (30 R; range, 0.8 to 300 R). Measured patient exposure increased with fluoroscopy time (r = 0.9) and with the number of interventions performed (r = 0.3). The mean dose to personnel was estimated at 0.04 mR. CONCLUSIONS: The patient radiation dose depended most on fluoroscopy time. The dose may be lowered by minimizing fluoroscopy time, using higher voltage and lower current for fluoroscopy, and using digital radiography for documentation. Personnel were adequately protected.

Adult↗

Accuracy of fluoroscopic localization of the Crista terminalis documented by intracardiac echocardiography.

The crista terminalis is an important anatomic target for ablation of atrial arrhythmias. We determined the accuracy of catheter placement guided by fluoroscopy alone when directed to 24 sites along the crista terminalis in 6 patients. The sites selected included the most medial superior, most lateral superior, mid lateral, and most inferolateral sites along the crista terminalis in each patient. These sites were selected because of their recognized importance in sinus node and/or atrial tachycardia ablation and the importance of avoiding caval structures when targeting the most superior and/or inferior right atrium. The position of the catheter tip was documented using a catheter based ultrasound transducer in the right atrium or vena cava. The operator was blinded to the intracardiac echocardiographic (ICE) results until reviewing the images after the procedure in each patient. The catheter tip, guided by fluoroscopy alone, was identified by ICE to be within the right atrium and within 1cm of the crista terminalis at only 10 of the 24 sites (42%). Importantly, when targeting the most superior and inferior sites along the crista terminalis, the catheter tip, guided by fluoroscopy, was noted to be adjacent to the venous junction with the right atrium but actually located in the superior or inferior vena cava at 5 of the 18 such sites. The catheter was positioned appropriately (within 1 cm of the crista and within the right atrium) guided by fluoroscopy alone when targeting 1 of the 12 sites in the first 3 patients versus 9 of 12 sites in the last 3 patients, p<0.05. In conclusion, it appears that using fluoroscopic guidance alone: 1) localization of the crista terminalis is frequently inaccurate and 2) catheter positioning in the superior/inferior vena cava is commonly noted when targeting very superior and inferior sites along the crista terminalis. A learning curve, assisted by review of ICE recordings after each procedure, appears to improve the accuracy of catheter placement by fluoroscopy alone but still does not result in uniform success. ICE appears to facilitate and ensure accurate targeting of specific anatomic sites along the crista terminalis and thus may serve as an important adjunctive imaging technique in electrophysiology.

Adult↗

Evaluation of a new three-dimensional magnetic imaging system for use during colonoscopy.

BACKGROUND AND STUDY AIMS: A prototype magnetic imaging system (Scope Guide, Olympus Optical Co., Ltd.) provides a new facility for continuous viewing on a monitor of the position of the colonoscope during examination, without exposing patients or medical staff to radiation. The aim of this prospective study was to compare this magnetic imaging system with routine colonoscopy, including fluoroscopy. The study parameters were the detection of loops, the location of the endoscope tip at defined positions, the insertion time, and the premedication rate. MATERIALS AND METHODS: In the first part of the study, 133 consecutive patients were examined - 64 using an integrated three-dimensional colonoscope and 69 with the three-dimensional probe inserted into the biopsy channel of a routine video colonoscope. Fluoroscopy was used in all investigations for comparison at defined anatomical points and loops, and pathological findings and defined anatomic structures were documented using a laser printer both for three-dimensional colonoscopy and fluoroscopy. In the second part of the study, 25 further patients underwent colonoscopy with a modified prototype, now exclusively using the integrated three-dimensional colonoscope. RESULTS: The total time for insertion and the premedication rate did not differ from those of routine colonoscopies with fluoroscopy available. Precise detection of loops was observed in the first study in 79 - 100 % of cases in comparison with fluoroscopy. Precise localization of the endoscopic tip improved from 30 % in the first part of the study to 80 % in part 2. CONCLUSION: Using magnetic three-dimensional imaging systems, the position of the colonoscope, the detection and observation of loops during straightening, and localization of pathological findings can be accurately achieved. Modification of the prototype led to satisfactory improvement in all parameters tested.

Colonoscopy↗

[Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation].

AIM: Goal of the current study was to compare radiation dose and fluoroscopy time of fluoroscopic computer assisted pedicle screw implantation versus the conventional technique. METHOD: For each of 10 specimens two pedicle screws were placed using conventional technique (group 1) and two screws were inserted with fluoroscopic navigation system (group 2) contralateraly. RESULTS: For implantation of two pedicle screws the mean radiation dose was 0.041 mSv in group 1 and 0.029 mSv in group 2. Fluoroscopy time was 34 seconds in group 1 and 25 seconds in group 2. The differences of radiation dose and fluoroscopy time for group 1 and 2 were statistically significant (radiation dose p = 0.00044, fluoroscopy time p = 0.00039). CONCLUSION: We achieved significantly lower radiation dose and fluoroscopy time with fluoroscopic computer assisted pedicle screw implantation compared with the conventional technique. Concerning exposure to radiation for patients and personnel fluoroscopic navigated screw insertion is to favour.

Body Burden↗

Radiation doses to patients from enteroclysis.

The purpose of this study was to determine the patient doses during enteroclysis and compare them with the available bibliographical data. For 14 enteroclysis examinations, the dose-area product (DAP) meter readings, fluoroscopy time, number of radiographs and exposure data were recorded. From these data, the fluoroscopy and radiography contributions to DAP, the entrance surface dose (ESD) and the effective dose (E) for each examination were estimated. The mean DAP was 81 Gy cm(2) and the mean fluoroscopy time was 19.5 min. The fluoroscopy contribution to DAP was 77% and 8.7 films were acquired in each examination on average. The mean ESD and E were estimated to be 428 mGy and 21 mSv, respectively. The mean DAP and fluoroscopy time calculated in this study are quite high when compared with those reported in the literature, suggesting that the examination technique should be reviewed and the ways to reduce patient exposure without compromising the diagnostic quality should be acquired.

Adult↗

A randomized study of oral metoclopramide in small bowel biopsy of infants and children.

As an intravenous injection is not used in our premedication of infants and children for small bowel biopsy, we investigated what effects oral metoclopramide might have on small bowel biopsy procedure time and fluoroscopy time. Eighteen infants and children were randomized to receive 0.2 mg/kg metoclopramide or placebo orally, 40-45 min before starting the procedure, and the procedure was monitored for the time required for the biopsy capsule to reach the pylorus, to cross into the proximal duodenum, and to reach the biopsy site. Corresponding fluoroscopy times were recorded as well. Mean total procedure time was less for those treated with metoclopramide, 43.7 +/- 11 min, than for controls, 86.5 +/- 15.5 min (p less than 0.005). Mean total fluoroscopy time was also less in treated patients (40.9 +/- 11.5 s versus control 84.4 +/- 17 s) (p less than 0.005). The effect of metoclopramide occurred in the interval for the biopsy capsule to cross the pylorus (15.1 +/- 2.7 min versus control 60.8 +/- 16.6 min) (p less than 0.005) and in fluoroscopy time required (15.1 +/- 1.9 s versus control 46 +/- 17 s) (p less than 0.005). Oral metoclopramide is effective in reducing procedure time for small bowel biopsy, and its predictable action facilitates reduction in fluoroscopy exposure.

Administration, Oral↗

Talocrural and subtalar joint instability after lateral ankle sprain.

PURPOSE: Recurrence of lateral ankle sprain (LAS) is common among recreational and competitive athletes. Talocrural (TC) joint laxity has traditionally been seen as the cause of mechanical instability after LAS. The purpose of this study was to examine the use of stress fluoroscopy and physical examination in the assessment of TC and subtalar (ST) instability in subjects with and without a history of LAS. METHODS: Twelve subjects with a history of unilateral LAS and eight healthy controls were examined by two blinded examiners. The first examiner performed physical examination on each ankle by using the anterior drawer (AD), talar tilt (TTPE), and medial subtalar glide (MSTG) tests. Laxity in each ankle was assessed on a 4-point scale. The second examiner performed stress fluoroscopy taking AP views with and without a manually applied supination stress to assess TC laxity and a sidelying modified Broden view with and without stress to assess ST laxity. Subjective examination of the images was used to determine excessive TC and ST laxity. RESULTS: Seventy-five percent of previously injured subjects demonstrated unilateral laxity differences of the TC joint using stress fluoroscopy. Of the nine with excessive talar tilt on fluoroscopy, 78% demonstrated excessive laxity with the AD and MSTG tests, and 67% demonstrated laxity with the TTPE test. Sixty-seven percent of those with TC laxity also demonstrated either excessive unilateral or bilateral laxity of the ST joint under stress fluoroscopy. CONCLUSIONS: These data suggest the existence of a subpopulation of patients with a history of LAS who demonstrate a pattern of combined TC and ST laxity.

Adult↗