Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUTOMATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

Short-wavelength automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes. Initial baseline results.

OBJECTIVE: To examine the relationship between the prevalence of short-wavelength sensitivity losses in the central 30 degrees visual field and risk factors for development of glaucomatous visual field loss in ocular hypertension. DESIGN: A modified Humphrey Field Analyzer was used to perform standard automated perimetry and short-wavelength automated perimetry (SWAP), which is a technique that isolates the activity of short-wavelength-sensitive ("blue") mechanisms. In addition, an assessment of the risk of developing glaucomatous visual field loss was determined, based on a validated model that utilized intraocular pressure, a family history of glaucoma, age, and the vertical cup-to-disc ratio. PATIENTS: Both eyes of 232 ocular hypertensive patients were examined and compared with results from an age-matched control group of normal subjects. Both ocular hypertensive patients and normal subjects had to have normal visual fields on standard automated perimetry, good visual acuity, and no evidence of other ocular or neurologic disease or surgery. Intraocular pressure in the ocular hypertensive patients was 21 mm Hg or greater OU (without medication), and it was less than 20 mm Hg OU in normal control subjects. RESULTS: Less than 10% of the low-risk ocular hypertensive eyes had a SWAP deficit, as compared with 20% of the moderate-risk and 33% of the high-risk ocular hypertensive eyes. Intraocular pressure and a family history of glaucoma showed no meaningful relationship with the prevalence of SWAP deficits, but both age and the vertical cup-to-disc ratio demonstrated a strong association with the SWAP abnormalities. CONCLUSIONS: The SWAP results that were found in the ocular hypertensive eyes were associated with other risk factors that have been reported to be predictive of the development of glaucomatous visual field loss, especially the vertical cup-to-disc ratio and age. These findings support the notion that the SWAP deficits represent early glaucomatous damage and may be related to early changes that occur at the optic nerve head.

Adult↗

Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial.

CONTEXT: High-quality cardiopulmonary resuscitation (CPR) may improve both cardiac and brain resuscitation following cardiac arrest. Compared with manual chest compression, an automated load-distributing band (LDB) chest compression device produces greater blood flow to vital organs and may improve resuscitation outcomes. OBJECTIVE: To compare resuscitation outcomes following out-of-hospital cardiac arrest when an automated LDB-CPR device was added to standard emergency medical services (EMS) care with manual CPR. DESIGN, SETTING, AND PATIENTS: Multicenter, randomized trial of patients experiencing out-of-hospital cardiac arrest in the United States and Canada. The a priori primary population was patients with cardiac arrest that was presumed to be of cardiac origin and that had occurred prior to the arrival of EMS personnel. Initial study enrollment varied by site, ranging from late July to mid November 2004; all sites halted study enrollment on March 31, 2005. INTERVENTION: Standard EMS care for cardiac arrest with an LDB-CPR device (n = 554) or manual CPR (n = 517). MAIN OUTCOME MEASURES: The primary end point was survival to 4 hours after the 911 call. Secondary end points were survival to hospital discharge and neurological status among survivors. RESULTS: Following the first planned interim monitoring conducted by an independent data and safety monitoring board, study enrollment was terminated. No difference existed in the primary end point of survival to 4 hours between the manual CPR group and the LDB-CPR group overall (N = 1071; 29.5% vs 28.5%; P = .74) or among the primary study population (n = 767; 24.7% vs 26.4%, respectively; P = .62). However, among the primary population, survival to hospital discharge was 9.9% in the manual CPR group and 5.8% in the LDB-CPR group (P = .06, adjusted for covariates and clustering). A cerebral performance category of 1 or 2 at hospital discharge was recorded in 7.5% of patients in the manual CPR group and in 3.1% of the LDB-CPR group (P = .006). CONCLUSIONS: Use of an automated LDB-CPR device as implemented in this study was associated with worse neurological outcomes and a trend toward worse survival than manual CPR. Device design or implementation strategies require further evaluation. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00120965.

Aged↗

The use of semi-automated EBV IgG avidity determination for the diagnosis of infectious mononucleosis.

The diagnosis of acute Epstein-Barr virus (EBV) infection is based frequently on the combination of positive viral capsid antigen (VCA) IgM antibodies and negative EB viral nuclear antigen 1 (EBNA-1) IgG antibodies. However, both VCA IgM and EBNA-1 IgG can provide false positive and false negative results. Therefore, situations in which the EBV serology remains unclear are not uncommon. Determination of EBV IgG avidity can clarify the EBV status in these patients. So far, mainly immunofluorescence assays have been used for this purpose. These tests are laborious, their evaluation is subjective, and automation is difficult. Therefore, two commercially available microtiter plate enzyme immunoassays (EIA) were compared for their usefulness for semi-automated EBV IgG avidity determination. One assay is based on a mixture of EBV antigens, the other assay uses a synthetic peptide of the VCA-complex. Patient sera of confirmed acute and past EBV infections were tested for avidity by both assays. The results with the antigen mixture assay proved to be highly sensitive (100%) and specific (100%). Avidity index calculations on the basis of one-point-quantification titers gave better results than calculations using OD values. Determination of EBV IgG avidity by the peptide assay was complicated by the fact that it was less sensitive than the antigen mixture assay for IgG detection in acute EBV infections. On the other hand, about 30% of the samples had to be retested with the peptide assay in a higher dilution because the IgG units in initial testing fell outside the range covered by the standard curve. Using OD values of the peptide EIA, the sensitivity was 99% but the specificity of detection of acute EBV infections was only 86%. Thus, while the peptide EBV avidity assay is unsuitable as a confirmatory assay, avidity testing with the antigen mixture assay is a useful tool to resolve equivocal EBV serologies. Avidity assays on the basis of EIA can be automated which should lead to wider use of this methodology.

Antibodies, Viral↗

Automated analysis of mammographic densities and breast carcinoma risk.

BACKGROUND: There is considerable evidence that one of the strongest risk factors for breast carcinoma can be assessed from the mammographic appearance of the breast. However, the magnitude of the risk factor and the reliability of the prediction depend on the method of classification. Subjective classification requires specialized observer training and suffers from inter- and intraobserver variability. Furthermore, the categoric scales make it difficult to distinguish small differences in mammographic appearance. To address these limitations, automated analysis techniques that characterize mammographic density on a continuous scale have been considered, but as yet, these have been evaluated only for their ability to reproduce subjective classifications of mammographic parenchyma. METHODS: In this study, using a nested case-control design, the authors evaluated the direct association between breast carcinoma risk and quantitative image features derived from automated analysis of digitized film mammograms. Two parameters, one describing the distribution of breast tissue density as reflected by brightness of the mammogram (regional skewness) and the other characterizing texture (fractal dimension), were calculated for images from 708 subjects identified from the Canadian National Breast Screening Study. RESULTS: These parameters were evaluated for their ability to distinguish cases (those women who developed breast carcinoma) from controls. It was found that both the skewness and fractal parameters were significantly related to risk of developing breast carcinoma. CONCLUSIONS: Although the relative risk estimates were moderate (typically > 2.0) and less than those from subjective classification or for an interactive computer method the authors have previously described, they are comparable to other risk factors for the disease. The observer independence and reproducibility of the automated methods may facilitate their more widespread use.

Adult↗

Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometry.

The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.

Autoanalysis↗

Discontinuations of antihyperlipidemic drug therapy: assessment by means of automated databases.

Discontinuations of drugs used in the treatment of chronic conditions such as hyperlipidemia often signal adverse drug effects or therapeutic ineffectiveness. Discontinuations of antihyperlipidemic drug therapy among 2369 patients were evaluated using the computerized files and written medical records of two health maintenance organizations (HMOs) in Massachusetts for the period 1988 to 1990. Three methods were assessed for the identification of potential discontinuations of drug therapy using the automated databases. Overall, 75% of discontinuations flagged by the automated databases were confirmed in the medical charts. (1) In new users, 618 of the 635 (97%) drugs identified as drug switches by the computerized HMO pharmacy files were confirmed as discontinuations by the medical charts. (2) Of 620 eligible HMO members 332 (54%) identified with greater than 6 months between the last refill for an antihyperlipidemic drug and the end of the study stopped the drug therapy according to the medical chart. (3) Of 219 eligible drug therapies flagged with an 'inactive' or with an 'omit' status in the clinical encounter files 198 (90%) were discontinued according to the medical chart. This study demonstrates the utility of clinical automated databases to facilitate the study of drug discontinuations in primary care settings, reducing the cost and the amount of time required for the evaluation.

Journal Article↗

Automated T2 quantitation in neuropsychiatric lupus erythematosus: a marker of active disease.

Active neuropsychiatric systemic lupus erythematosus (NPSLE) is characterized by brain edema as measured by manual quantitative magnetic resonance (MR) relaxometry. An automated image processing method was developed to segment gray matter (GM), while minimizing the effects of confounding factors, specifically cerebral atrophy and volume averaging artifacts. Twenty patients with SLE (10 major, 10 minor), matched for atrophy, were studied. We compared T2 calculated for GM segmented by manual and automated methods. Both methods demonstrated a marked increase in GM T2 in patients with major NPSLE (P < 0.001), confirming the presence of cerebral edema. The results from each method were highly correlated, (r = 0.64, P = 0.002). The automated method effectively identifies GM, minimizes volume averaging artifacts, and produces results similar to the manual method. This method markedly decreases analysis time and will make quantitative relaxometry a valuable contribution to the clinical management of NPSLE.

Adult↗

An automated machine vision system for the histological grading of cervical intraepithelial neoplasia (CIN).

The histological grading of cervical intraepithelial neoplasia (CIN) remains subjective, resulting in inter- and intra-observer variation and poor reproducibility in the grading of cervical lesions. This study has attempted to develop an objective grading system using automated machine vision. The architectural features of cervical squamous epithelium are quantitatively analysed using a combination of computerized digital image processing and Delaunay triangulation analysis; 230 images digitally captured from cases previously classified by a gynaecological pathologist included normal cervical squamous epithelium (n=30), koilocytosis (n=46), CIN 1 (n=52), CIN 2 (n=56), and CIN 3 (n=46). Intra- and inter-observer variation had kappa values of 0.502 and 0.415, respectively. A machine vision system was developed in KS400 macro programming language to segment and mark the centres of all nuclei within the epithelium. By object-oriented analysis of image components, the positional information of nuclei was used to construct a Delaunay triangulation mesh. Each mesh was analysed to compute triangle dimensions including the mean triangle area, the mean triangle edge length, and the number of triangles per unit area, giving an individual quantitative profile of measurements for each case. Discriminant analysis of the geometric data revealed the significant discriminatory variables from which a classification score was derived. The scoring system distinguished between normal and CIN 3 in 98.7% of cases and between koilocytosis and CIN 1 in 76.5% of cases, but only 62.3% of the CIN cases were classified into the correct group, with the CIN 2 group showing the highest rate of misclassification. Graphical plots of triangulation data demonstrated the continuum of morphological change from normal squamous epithelium to the highest grade of CIN, with overlapping of the groups originally defined by the pathologists. This study shows that automated location of nuclei in cervical biopsies using computerized image analysis is possible. Analysis of positional information enables quantitative evaluation of architectural features in CIN using Delaunay triangulation meshes, which is effective in the objective classification of CIN. This demonstrates the future potential of automated machine vision systems in diagnostic histopathology.

Female↗

Automated nanoflow liquid chromatography/tandem mass spectrometric identification of proteins from Shewanella putrefaciens separated by two-dimensional polyacrylamide gel electrophoresis.

The implementation of nanoflow liquid chromatography offers unique opportunities for automation of proteomics research. We demonstrate that automated nanoflow LC/MS/MS allowed the unambiguous identification of proteins from the omnipotent bacterium Shewanella putrefaciens, based on similarity searches against the completely determined genome of related microorganisms and against non-redundant databases. Total protein extracts were separated by 2-dimensional polyacrylamide electrophoresis. Only 1/20th of a tryptic digest mixture obtained from a single Coomassie Blue stained spot was loaded on the nanoflow LC column using a preconcentration/desalting step, and analyzed on-line on a hybrid quadrupole time-of-flight mass spectrometer with an automated MS-to-MS/MS switching protocol. This method allowed the de novo peptide sequence determination of several tryptic fragments and the identification of different proteins. CopyrightCopyright 2000 John Wiley & Sons, Ltd.

Amino Acid Sequence↗

Proteomic study of the soluble proteins from the unicellular cyanobacterium Synechocystis sp. PCC6803 using automated matrix-assisted laser desorption/ionization-time of flight peptide mass fingerprinting.

The unicellular cyanobacteria Synechocystis sp. (PCC6803) has become a model organism for a range of biochemical and molecular biology studies aimed at investigating environmental stress responses. In this study the soluble proteins of Synechocystis were analysed using narrow pH range (pH 4.5-5.5) zoom gels, automated matrix-assisted laser desorption/ionization mass spectrometry acquisition, spectral processing and database searching. The work sets the foundation for investigations of proteomic changes following stress treatment. One hundred and ninety-two protein spots were analysed and 105 proteins identified, of these 37 were novel proteins not previously seen on two-dimensional gels. Proteins involved in amino acid biosynthesis, energy metabolism and protein modification were identified using this fully automated procedure demonstrating that automated acquisition and processing will be a useful tool for proteomic analyses on this organism.

Bacterial Proteins↗

Correlation of hematopoietic progenitor cell count determined by the SE-automated hematology analyzer with CD34(+) cell count by flow cytometry in leukapheresis products.

The yield of stem cell collection after mobilization is crucial for autologous peripheral blood stem cell (PBSC) transplantation. Quantitative determinations of CD34(+) cells using flow cytometry or stem cell culture have been used, but these methods require much time, technical experience, and expensive reagents. The automated hematology analyzer (Sysmex SE-9000trade mark, TOA, Japan) equipped with the Immature Information (IMI) channel for immature myeloid cells can detect IMI(+) cells within 90 sec. Detection is made possible by the combination of a special reagent system and direct current/radiofrequency biosensors. We studied the relation of IMI(+) cells and variable cell counts with CD34(+) cell yield in autologous stem cell harvest. In a series of 32 patients (median age, 44 years; M:F = 11:21), 184 leukaphereses were performed after mobilization regimens with chemotherapy and G-CSF or G-CSF alone. Full blood cell counts were enumerated on peripheral blood (PB) samples taken prior to each leukapheresis. Mononuclear cell (MNC) and IMI(+) cell counts by automated hematology analyzer and flow cytometry based CD34(+) cell yield were measured on the harvested product. The relationship among PB white blood cells (WBC), PB monocytes, IMI(+) cells, MNC, and CD34(+) cell yield in a single leukapheresis was estimated by Pearson correlation analysis. PB WBC count showed no correlation with CD34(+) cell yield in a single leukapheresis (r = 0.02, P = 0.81). PB monocyte count showed a weak correlation (r = 0.21, P = 0.01) and MNC in harvest also showed a weak correlation (r = 0.36, P = 0.0001) with CD34(+) cell yield. In contrast, CD34(+) cell yield correlated well with IMI(+) cell count (r = 0.68, P = 0.0001), and data could be fitted by a linear regression equation, y = 0.330 + 0.974x. IMI(+) cell assay by the automated hematology analyzer correlated well with the CD34(+) cell yield in a mobilized autologous stem cell harvest. The IMI(+) cell count might be used as a simple and efficient indicator of blood stem cell mobilization and collection.

Adolescent↗

Automated maintenance of embryonic stem cell cultures.

Embryonic stem cell (ESC) technology provides attractive perspectives for generating unlimited numbers of somatic cells for disease modeling and compound screening. A key prerequisite for these industrial applications are standardized and automated systems suitable for stem cell processing. Here we demonstrate that mouse and human ESC propagated by automated culture maintain their mean specific growth rates, their capacity for multi-germlayer differentiation, and the expression of the pluripotency-associated markers SSEA-1/Oct-4 and Tra-1-60/Tra-1-81/Oct-4, respectively. The feasibility of ESC culture automation may greatly facilitate the use of this versatile cell source for a variety of biomedical applications.

Animals↗

Quantitative metabolic profiling of valproic acid in humans using automated gas chromatographic/mass spectrometric techniques.

An automated gas chromatographic/mass spectrometric assay is described for the antiepileptic drug valproic acid (VPA) and 14 of its metabolites in plasma or urine. Quantitative analysis of the parent drug and its biotransformation products was carried out with the aid of trimethylsilyl derivatives, and was performed by selected ion monitoring gas chromatography/mass spectrometry (normally of [M-CH3]+ species) using an HP 5790 mass selective detector (MSD) quadrupole mass spectrometer. The analysis was fully automated, in that simple injection, data acquisition, integration, quantification and report functions were carried out during unattended operation by an HP 59970C ChemStation computer system. The method exhibits good accuracy and high precision, with correlation coefficients greater than 0.990 for all standard curves. Replicate analyses of pooled plasma samples over a 4 month period exhibited an inter-day variation of less than 15% for the parent drug and ten of its metabolites. Moreover, the high dynamic range of the MSD instrument permitted quantification of VPA and minor metabolites thereof (e.g. the hepatotoxic terminal olefin, delta 4-VPA) at levels as disparate as 260 micrograms ml-1 (VPA) and 14 ng ml-1 (delta 4-VPA) in a single analysis. The high stability and sensitivity of the assay, combined with the fully automated features of the instrumentation, make the method ideally suited to expanded clinical studies and for the routine monitoring of potentially high-risk patients on VPA therapy.

Gas Chromatography-Mass Spectrometry↗

Comparison of exercise blood pressure measured by technician and an automated system.

We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

Blood Pressure↗

Automated protein-ligand crystallography for structure-based drug design.

An approach to automate protein-ligand crystallography is presented, with the aim of increasing the number of structures available to structure-based drug design. The methods we propose deal with the automatic interpretation of diffraction data for targets with known protein structures, and provide easy access to the results. Central to the system is a novel procedure that fully automates the placement of ligands into electron density maps. Automation provides an objective way to structure solution, whereas manual placement can be rather subjective, especially for data of low to medium resolution. Ligands are placed by docking into electron density, whilst taking care of protein-ligand interactions. The ligand fitting procedure has been validated on both public domain and in-house examples. Some of the latter deal with cocktails of low-molecular weight compounds, as used in fragment-based drug discovery by crystallography. For such library-screening experiments we show that the method can automatically identify which of the compounds from a cocktail is bound.

Crystallography, X-Ray↗

Evaluation of an automated immunochemical fecal occult blood test for colorectal neoplasia detection in a Chinese population.

BACKGROUND: Most commercial fecal occult blood tests (FOBT) used for colorectal carcinoma screening of Western populations are guaiac-based, manually developed, subjective, and sensitive to dietary components. Preliminary studies demonstrated the unsuitability of these tests for screening a Chinese population. The goal of the current study was to evaluate the performance characteristics of a human hemoglobin-specific automated immunochemical FOBT, the Magstream 1000/Hem SP (Fujirebio, Inc., Tokyo, Japan), in a Chinese population referred for colonoscopy. METHODS: Two hundred fifty consecutive patients who were referred for colonoscopy and met the study inclusion criteria provided samples for the immunochemical FOBT (without dietary restrictions) from two successive stool specimens. Tests were developed with an automated instrument that had an adjustable sensitivity threshold. The sensitivity, specificity, and positive predictive value for detecting colorectal adenomas and carcinomas were calculated according to the manufacturer's instructions over a range of sensitivity levels. RESULTS: At the optimal threshold level, the sensitivity, specificity, and positive predictive value for detection of significant colorectal neoplasia (adenomas >or= 1.0 cm and carcinomas) were 62%, 93%, and 44%, respectively. The test was easy to use, and results did not depend on operator experience. CONCLUSIONS: The automated immunochemical FOBT used in the current study was a robust, convenient, and useful tool for colorectal carcinoma screening in the study population.

Adenoma↗

New high-resolution 2-deoxyglucose method featuring double labeling and automated data collection.

A new approach to high-resolution 2-deoxy-D-glucose (2DG) emulsion-autoradiography which combines improved retention of 2DG labeling, staining with immunohistochemical and other specific markers, and automated data collection and analysis of local silver grain and stain densities is described. The Durham et al. (J. Neurosci. 1:519-526, '81) procedure for fixation of 2DG with periodate-lysine-paraformaldehyde (PLP, McLean and Nakane: J. Histochem. Cytochem. 22:1077-1083, '74) was adapted to increase retained label roughly tenfold. Phenobarbital anesthesia is induced 45 minutes after 2DG injection. Barbiturate anesthesia increases brain glycogen (Nelson et al.: J. Neurochem. 15:1271-1279, '68) and presumably increases the incorporation of intracellular 2DG from 2DG-6P into brain glycogen and other molecules (Nelson et al.: J. Neurochem. 43:949-956, '84; Pentreath et al.: Neuroscience 7:759-767, '82). Iodoacetate is added to cold fixative to prevent glycogen breakdown (Cammermeyer and Fenton: Histochemistry 76:339-356, '82). This high-resolution 2DG protocol is directly compatible with many other neuroanatomical techniques. We demonstrate 2DG emulsion autoradiography combined with cytochrome oxidase (CO) histochemistry, markers for axonal pathway tracing, plastic embedding for semithin sections, and immunohistochemical staining for glutamate decarboxylase (GAD). The method should be compatible with antibodies for other antigens and with other neuroanatomical stains. To collect the data directly from microscope slides, a computer-controlled microscope was integrated with image-processing software to eliminate the need for manual counting and scoring of autoradiograms. Regions of interest are scanned automatically at high resolution to map regional labeling and/or stain density. There is excellent correspondence between computer-enhanced two-dimensional maps of the data and the original autoradiograms. Automated counts for five specimens were compared to counts of labeled cells by trained observer. The correlation between the two sets of measurements is high (r = .93). Automated data collection has been generalized to measure regional stain densities on the autoradiographed sections for direct comparison with silver grain density. The method is extremely flexible, especially since new image-processing strategies can be developed in software to extract the desired information from materials labeled by other methods (e.g., HRP).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Use of automated microscopy for the detection of disseminated tumor cells in bone marrow samples.

The use of automated microscopy has reached the maturity necessary for its routine use in the clinical pathology laboratory. In the following study we compared the performance of an automated microscope system (MDS) with manual method for the detection and analysis of disseminated tumor cells present in bone marrow preparations from breast carcinoma patients. The MDS System detected rare disseminated tumor cells among bone marrow mononuclear cells with higher sensitivity than standard manual microscopy. Automated microscopy also proved to be a method of high reproducibility and precision, the advantage of which was clearly illustrated by problems of variability in manual screening. Accumulated results from two pathologists who had screened 120 clinical slides from breast cancer patients both by manual microscopy and by use of the MDS System revealed only two (3.8%) missed by the automatic procedure, whereas as many as 20 out of 52 positive samples (38%) were missed by manual screening.

Bone Marrow Examination↗