Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

In vivo moment arm calculations at the ankle using magnetic resonance imaging (MRI).

In vivo moment arm lengths for the Achilles tendon and tibialis anterior (TA) were determined in 10 adult male subjects. Moment arms were measured as the perpendicular distance between the joint center of rotation (CR) and the center of the muscle's tendon on a series of sagittal plane magnetic resonance images. The first set of calculations used a fixed CR and the second a moving CR. The position of the CR was determined using a modification of the graphical method of Reuleaux. For both moving and fixed CR conditions, moment arms increased by approximately 20% for the Achilles tendon and decreased by approximately 30% for the TA when the ankle moved from maximum dorsiflexion to maximum plantarflexion. Moment arms averaged 3.1% greater for the Achilles tendon and 2.5% greater for the TA when calculated using a fixed CR. These data suggest that the averaged moment arm lengths for the Achilles tendon and the TA were relatively unaffected by the use of a fixed vs moving CR.

Achilles Tendon↗

Knee muscle moment arms from MRI and from tendon travel.

We tested magnetic resonance imaging (MRI) as a means to collect geometric data for moment arm estimation. A knee specimen in five successive flexion postures was scanned by MRI, while simultaneously tendon positions of loaded muscles were measured (long head of biceps femoris, lateral and medial gastrocnemius, gracilis, rectus femoris, sartorius, semimembranosus, semitendinosus, and tensor fasciae latae). Discrete rotation centres were derived from MRI pictures. Moment arms were estimated as the distances from these centres to the tendons. The ratio of tendon travel over the increment of joint angulation was the alternative, more reliable estimate of the moment arm. An important principal shortcoming of MRI is the impossibility of accounting for force distribution in taut tissue. As a consequence, for some muscles, considerable inaccuracies in moment arm estimation are found in a relatively small range of joint angulation (up to about 30% for the rectus femoris and semimembranosus). For the tensor fasciae latae, the moment arm cannot be estimated by MRI, while the estimate by tendon travel is unreliable owing to the deformability and attachments of the fascia lata.

Aged↗

The influence of tendon Youngs modulus, dimensions and instantaneous moment arms on the efficiency of human movement.

The purpose of the study was to examine the influence of passive tendon work on the gross mechanical efficiency of human whole body movement. Seven male subjects participated in the study. They performed repetitive jumps (like skipping) of three different intensities. Metabolic costs and work rates were recorded to obtain mechanical efficiencies. Net joint moments were calculated from film recordings using inverse dynamics. A general stress-strain relationship for tendons was modelled using a quadratic function, including Youngs elastic modulus of tendon tissue and tendon dimensions. Instantaneous tendon moment arms for the largest leg extensor muscles (m. triceps surae and m. quadriceps femoris) were calculated using joint angle-moment arm transfer functions obtained from the literature (cadaver studies) and the tendon work was calculated from the net joint moments. Gross efficiency values of 0.65-0.69 and efficiency values of 0.77-0.80 at the approximate level of the muscle-tendon complexes were observed. The tendons performed 52-60% of the total work. The enhancement of the muscle-tendon efficiency over the maximal theoretical efficiency of the contractile machinery (0.30) could exclusively be explained by the contribution of the tendon work. A clear negative relationship between repetitive jumping with high mechanical efficiency and running economy at 12 km h-1 was found. Using model calculations the gross efficiency and the muscle-tendon efficiency were shown to be sensitive to tendon Youngs modulus, dimensions and moment arms. The efficiencies were most sensitive to changes in the tendon moment arms. A 10% decrease in tendon moment arms resulted in a 13% increase in the gross efficiency. Optimization or minimisation of the mechanical efficiency by changing the tendon variables 5% was followed by changes in mechanical efficiency of +14% and -10%, respectively.

Adult↗

Structural comparison of purified dynein proteins with in situ dynein arms.

Using the quick-freeze deep-etch technique, we describe the structure of outerarm dynein proteins from Chlamydomonas and Tetrahymena after adsorption to a mica surface, after high-salt dissociation, and after glutaraldehyde fixation, and compare these images to the configuration of outer arms bound to microtubules. After adsorption to mica, the extracted dyneins from both organisms look like three-headed "bouquets", as reported for Tetrahymena by Johnson & Wall (1983b). High magnification images demonstrate that each head carries a slender "stalk" and a long "stem", and that small subunits decorate the stems and create a "flowerpot" domain at the base of the bouquet. Exposure to high salt induces this trimer to dissociate into a two-headed species and a single-headed species; it also stimulates the decorative elements to dissociate from the stems. Dynein is thus constructed on the same general plan as myosin, with large globular heads, narrow stems and additional small subunits that associate with the stems. The splayed-out image of the bouquet appears to be a distortion arising during adsorption to mica since, after brief glutaraldehyde fixation, the three heads remain closely associated as vertices of a triangular unit. In situ, the three heads also adopt this trigonal configuration. Two of the three are visible from the exterior of the axoneme and constitute the bilobed rigor head we described previously (Goodenough & Heuser, 1982). The third head faces the interior of the axoneme where, we propose, it forms the "hook" of the outer arm as seen in thin section. We further propose that the decorative elements associated with the stem coalesce to form the two outer-arm "feet" seen in situ, and that at least one of the in vitro stalks is equivalent to the in situ stalk, which extends from the head to the B microtubule. Deep-etch images of stretched axonemes, partially extracted axonemes, and dynein-decorated brain microtubules indicate that each outer arm, as traditionally viewed, is a hybrid of two dynein molecules: its two feet derive from one molecule, whereas its trigonal head derives from the molecule located distally. The resultant overlapping configuration creates the diagonal "linkers" seen in situ, which correspond to the in vitro stems. Thus, a row of dynein arms is essentially a dynein polymer that extends from the tip to the base of a doublet microtubule, each head riding on its neighbor's feet like a row of circus elephants.(ABSTRACT TRUNCATED AT 400 WORDS)

Adenosine Triphosphatases↗

Effects of the NMDA antagonists CPP and MK-801 on radial arm maze performance in rats.

The dose- and time-dependent effects of N-methyl-D-aspartate receptor/channel antagonists on radial 8-arm maze performance were examined in rats. Both CPP (1.0-30 mg/kg), a competitive NMDA antagonist, and MK-801 (0.1-1.0 mg/kg), a noncompetitive NMDA antagonist, produced dose-dependent increases in the number of errors made to sample all 8 baited arms. The effective doses of both drugs produced maximal performance impairments 2 hr after IP injection, and no effects after 24 hr. In a second radial arm maze task where only 4 arms were baited, CPP (10 mg/kg) had a somewhat greater effect on the number of working memory errors than on reference memory errors. MK-801 (0.1, 0.33 mg/kg) had no effects on either this task or on a task involving a 1-hr delay between correct choices 4 and 5 on the 8 choice task. CPP (10 mg/kg), however, impaired performance on this latter task. These results indicate that doses of NMDA antagonists, sufficient to block hippocampal long-term potentiation, also disrupt radial arm maze performance.

Animals↗

Microtubule polarity and the direction of pigment transport reverse simultaneously in surgically severed melanophore arms.

The transport of pigment through the long cytoplasmic extensions (arms) of teleost melanophores is a microtubule-dependent event. We have severed the arms from melanophores to test whether microtubules isolated from the centrosome maintain their original polarity and disposition. In addition, we have tested whether arms containing microtubules of mixed polarities alter the direction of pigment transport. We find that microtubules within severed arms eventually change their polarity and reorganize from the arm center as if to form a new minicell. Concomitant with this change is a reversal in the direction of pigment transport.

Animals↗

Impedance imaging in upper arm fractures.

We used the Aberdeen impedance imaging system to drive a constant current of 1 mA on a 10 kHz sine wave into the upper arm encircled by an elastic belt of 16 equi-spaced strip electrodes. The system was used to examine a normal upper arm, an upper arm with a recent humeral fracture and an upper arm with a clinically united fracture. We approximated the human upper arm to a circular cylinder and assumed bilateral symmetry of normal human limbs. We measured transverse limb resistivity ratios and reconstructed static two-dimensional images of the spatial distribution of log(resistivity) by the equipotential back projection technique using a homogeneous muscle equivalent saline reference. Our results indicate that impedance osteography provides unique information about the changing electrical characteristics at the fracture site. This information could prove a useful adjunct to clinical and radiological tests for fracture union.

Calibration↗

Homozygosity of the short arm of chromosome 17 in cervical carcinoma.

We have determined the frequency of heterozygosity of the short arm of chromosome 17 in 20 cervical tumours using the highly polymorphic probe pYNZ22. Only 25% of the tumours were heterozygous at this locus. This is significantly lower than the level of 86% heterozygosity for this locus in the general population indicating that loss of one allele occurs in cervical cancer. Heterozygosity for a locus on the long arm of the same chromosome showed no significant difference between the tumours and the general population indicating that genetic loss was confined to the short arm of the chromosome. The analysis of premalignant lesions showed 70% of patients were heterozygous suggesting that loss of material from the short arm of chromosome 17 took place at a late stage in tumour development. This report confirms predictions made from previous karyotypic analysis and is the first indication of allele loss on the short arm of chromosome 17 in cervical cancer.

Alleles↗

Widespread absence of outer dynein arms in the spermatozoids of lower plants.

Transverse sections of flagellar axonemes from a variety of lower plant spermatozoids were examined by electron microscopy. Motile sperm of four ferns (Marsilea, Pteridium, Lygodium and Aneimia), a horsetail (Equisetum) and a liverwort (Marchantia) were fixed in the presence of tannic acid to visualise the dynein arms. In all cases the inner dynein arms were clearly resolved but the outer arms were absent. Absence of outer arms therefore appears to be a common feature of the archegoniate plants. The implications of these findings to our understanding of the evolution of the land plants and the role of the dynein arms in flagellar beating is discussed.

Adenosine Triphosphatases↗

Vectors for inserting selectable markers in vector arms and human DNA inserts of yeast artificial chromosomes (YACs).

To facilitate studies of gene expression and homologous recombination, plasmids have been developed which permit the insertion of neomycin resistance-encoding gene (NmR) into either the human DNA insert or the vector arm of a yeast artificial chromosome (YAC). To integrate into the YAC arm, the plasmid pRV1 contains a LYS2 (encoding alpha-aminoadipate reductase) gene for selection in the yeast host, and a NmR gene for subsequent selection after transfection of mammalian cells. These two sequences are bracketed by fragments of the URA3 gene (encoding orotidine-5'-phosphate decarboxylase) that can disrupt the URA3 gene in the YAC arm by homologous recombination in yeast. To integrate a selectable marker into the insert, the plasmid pRV2 contains a NmR gene and an intact copy of the URA3 gene, bracketed by segments of an L1 (LINEs) repetitive element. In this case, the vector has been designed for use with YACs that have already been fitted in the vector arm with a different marker (i.e., TK) that has disrupted the URA3 gene in the vector arm. Selection is for the restoration of URA3 gene activity attendant on recombination into an L1 element in the YAC insert. Use of the vectors is illustrated with a YAC clone containing ribosomal DNA.

Aldehyde Oxidoreductases↗

Physiologic responses to arm ergometry exercise relative to age and gender.

Arm ergometry exercise testing is a valuable alternative method used in the evaluation and management of patients with both cardiac disease and lower limb impairment. The purpose of this study is to provide information concerning the physiologic responses of normal healthy subjects to arm ergometry relative to age and gender, which could serve as a standard for comparison. Eighty healthy subjects (age 22 to 59 years) cycled at 75 to 80 rpm (on a bicycle adapted for arm ergometry) starting at a power output of 10 W, increasing at 10 W/2 min until exhaustion. Sixty subjects were classified on the basis of age into three groups, each with 10 men and 10 women. Men achieved significantly (p less than 0.001) higher power output (95 +/- 25 W) and oxygen consumption (20.7 +/- 3.9 ml/kg per min) than did women (56 +/- 19 W and 15.5 +/- 3.1 ml/kg per min, respectively). The heart rate response to total body oxygen demand during arm ergometry was significantly higher in women than in men (p less than 0.001). These findings were also present when men and women of each age group were analyzed separately. Older subjects reached a significantly (p less than 0.02) lower peak power output than did younger subjects although they reached a similar level of oxygen consumption. Separate regression equations for predicting oxygen consumption at each power output were formulated for men and women and validated in 20 other subjects. Small differences in measured and predicted oxygen consumption at each stage were found. These data provide additional information concerning arm ergometry testing and should prove useful in diagnostic exercise testing and cardiac rehabilitation.

Adult↗

The gradient of luminosity between open/enclosed arms, and not the absolute level of Lux, predicts the behaviour of rats in the plus maze.

The effect of the gradient of luminosity between the open and the enclosed arms (O/E(DeltaLux)) of the elevated plus maze (EPM), upon the level of fear/anxiety in rats submitted to the trial 1/trial 2 paradigm was investigated. Male Wistar rats were assigned to freely explore either of three EPM configuration, with the enclosed arm walls constructed with either translucent glass (O/E(DeltaLux)=11), opaque glass (O/E(DeltaLux)=96) or wood (O/E(DeltaLux)=141), for 2 consecutive days (trial 1/trial 2). Independently of the EPM configuration, rats exhibited increased fear during trial 2 relative to trial 1, thus indicating that the level of O/E(DeltaLux), at least in the range used here, is not a determinant variable for the establishment of increased anxiety induced by prior maze experience. The groups tested under 11 and 141 O/E(DeltaLux) were those who exhibited the low and higher level of open arm avoidance, respectively. There was also an increased open arms avoidance over trial 1 in rats tested under 11 and 96 O/E(DeltaLux), only. These results suggest that the enclosed arm preference of rats during trial 1 EPM procedure may be changed by the level of O/E(DeltaLux) of the test. The present results are discussed with respect to the controversy regarding the role of luminosity on EPM performance.

Analysis of Variance↗

Spontaneously hypertensive, Wistar-Kyoto and Sprague-Dawley rats differ in performance on a win-shift task in the water radial arm maze.

The spontaneously hypertensive rat (SHR) is a commonly used animal model of attention deficit hyperactivity disorder. Previous literature is inconclusive with respect to the exact nature of memory impairments in this strain. The objective of this study was to assess spatial memory as measured by performance of male SHR, Wistar-Kyoto (WKY) and Sprague-Dawley (SD) rats on a win-shift version of the water radial arm maze. On this task, all strains made more errors on Trial 4 when the mnemonic demand was highest, and showed a similar response when the delay was increased from 60s to 2h on Week 3. Both SHR and WKY rats made more reference memory errors than SD, however, SHR showed minimal improvement over weeks. The increase in errors may be due to a greater inclination of SHR and WKY to use a chaining strategy of entering consecutive arms than SD. Furthermore, the number of incomplete arm entries into reference memory arms decreased over weeks in WKY and SD, but increased in SHR, suggesting increased impulsivity of SHR at the later stages of testing. Although based on number of errors, the data indicate that SHR may have memory deficits, the data relating to arm entries suggest that the minimal improvement in SHR over weeks may have been due to greater impulsivity in the later weeks, rather than defective memory. Thus, these findings are consistent with SHR having impairments with selection of appropriate behavioural responses in a goal-directed task.

Analysis of Variance↗

Integrating mutation, copy number, and gene expression data to identify driver genes of recurrent chromosome-arm losses.

Aneuploidy is a hallmark of cancer, yet the genes driving recurrent chromosome-arm losses remain largely unknown. We present a systematic framework integrating mutation, copy number, and gene expression data to identify candidate driver genes of cancer type-specific recurrent chromosome-arm losses across 20 cancer types, using ∼7,500 tumors from The Cancer Genome Atlas. By analyzing focal deletions and point mutations that co-occur, or are mutually exclusive, with chromosome-arm losses, we pinpoint 322 candidate drivers associated with 159 recurring events. Our approach identifies known aneuploidy drivers such as TP53 and PTEN, while revealing multiple additional candidates, including tumor suppressors not previously linked to aneuploidy. We leverage expression changes associated with chromosome-arm losses to propose cancer-promoting pathway-level alterations. Integrating these findings highlights key candidate drivers that underlie the observed expression alterations, reinforcing their biological relevance. We provide a comprehensive catalog of candidate driver genes for recurrently lost chromosome-arms in human cancer.

Humans↗

Sagittal plane moment arms of the female lumbar region rectus abdominis in an upright neutral torso posture.

BACKGROUND: Prior imaging studies of torso muscle moment arms for use as inputs into biomechanical models have been derived from subjects lying supine. Recent research suggests moment arms of the rectus abdominis are larger when standing versus lying supine. METHODS: Axial MRI images, through and parallel to the intervertebral discs were obtained from five females in a standing upright neutral posture. Digitizing software was utilized to quantify the distance in the sagittal plane between the centroids of the intervertebral disc and the rectus abdominis muscle, and converted to the transverse plane to allow comparisons with studies with subjects in a supine posture. FINDINGS: The mean sagittal plane moment arms in the transverse plane were 9.7, 9.1, 8.5, 8.5 and 9.8 cm at the L(1)/L(2), L(2)/L(3), L(3)/L(4), L(4)/L(5) and L(5)/S(1) intervertebral levels, respectively. Compared with a study on females of a similar age group, the moment arms from this study were larger at each level, increasing from 7.3% larger at L(1)/L(2) to 43.7% larger at L(5)/S(1). INTERPRETATION: Accurate anatomical geometrical representation in biomechanical models is necessary for valid estimates of internal loading. Sagittal plane rectus abdominis moment arms were larger from the upright neutral torso posture in this study compared to studies with subjects lying supine. This suggests the torso internal moment generating capability would be represented differently in biomechanical models that use data from studies where subjects were upright, which is more reflective of the postures biomechanical models are utilized for, than when using anatomical geometry derived from supine postures.

Abdomen↗

Synthesis and preparation of novel 4-arm star-shape poly(carboxylic acid)s for improved light-cured glass-ionomer cements.

OBJECTIVE: The objective of this study was to synthesize and characterize novel 4-arm star-shape poly(acrylic acid)s (poly(AA)s) via atom-transfer radical polymerization (ATRP) technique, tether in situ light-curable methacrylate functionalities onto the poly(AA) backbone, use these star-shape poly(AA)s to formulate the light-cured glass-ionomer cements (LCGICs), and evaluate the mechanical strengths of the formed cements. MATERIALS AND METHODS: The 4-arm poly(AA)s were synthesized using ATRP and tethered with either 2-isocyanatoethyl methacrylate (IEM) or glycidyl methacrylate (GM). The polymers were formulated with 2-hydroxyethyl methacrylte (HEMA) or methacryloyl beta-alanine (MBA), water, initiators, and Fuji II LC filler. Compressive strength (CS) was used as a tool to evaluate the formed cements. The specimens were conditioned in distilled water at 37 degrees C for 24h prior to testing. RESULTS: The 4-arm poly(AA) showed a lower viscosity as compared to its linear counterpart. Both IEM-tethered and GM-tethered 4-arm poly(AA) constructed LCGICs showed significantly high mechanical strengths. Both types of co-monomer and grafting agent dramatically affected the mechanical strengths. The MBA-containing poly(AA) cements exhibited much higher CS than the HEMA-containing cements. The IEM-tethered poly(AA) cements showed much higher CS and DTS than the GM-tethered cements. CONCLUSIONS: This study developed a novel light-curable 4-arm star-shape poly(AA) system. The system was 13% in CS, 178% in DTS and 123% in FS, compared to Fuji II LC.

Acrylic Resins↗

Improvement in the visualization of superficial arm veins being evaluated for access and bypass.

OBJECTIVES: Duplex ultrasound mapping of arm veins is being performed with increasing frequency. Unlike ultrasound testing in other areas, this has never been subjected to a gold standard invasive test to determine accuracy. Duplex mapping appears to have a good predictive value whenever large veins are demonstrated preoperatively, but its ability to accurately measure minimum-sized veins is unproven. In this study, we compared diameter measurements obtained under six different conditions and used the maximum diameter as the comparison gold standard. METHODS: A 12-MHz linear probe was used to measure the cephalic and basilic vein cross-sectional diameters at the wrist level in 24 normal volunteers under the following conditions: (1) resting supine with a room temperature of 23 degrees to 24 degrees C, (2) supine with a tourniquet inflated to 65 mm Hg, (3) sitting with the arm dangling, (4) sitting with a tourniquet, (5) sitting after a 2-minute immersion in warm water (44 degrees C), and (6) same with tourniquet. Half the subjects underwent the protocol in a different order. RESULTS: Vein diameters were significantly larger after submersion in warm water compared with supine (P < .05, pair-wise multiple comparison procedure, Student-Newman-Keuls method). Assuming the sitting position (from supine) resulted in a decreased arm vein diameter 58% of the time. In 25% of the normal subjects, the cephalic vein size was <2 mm, which increased to >2 mm after warming. All subjects had either a cephalic or a basilic vein at the wrist that was >3.1 mm after warming. CONCLUSION: Use of warm water immersion before vein diameter measurement in a sitting position, without a tourniquet, will result in significantly larger diameter findings in normal arm veins. These diameters are likely to more closely resemble the venous diameter after distension with arterial pressure. Further studies are needed to see if warming in patients could result in increased utilization of autogenous arm vein for dialysis access and bypass.

Adult↗

Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm.

Total knee arthroplasty implant designs with larger extensor moment arms theoretically should generate lower extensor forces for the same externally applied loads. This study measured knee kinematics, quadriceps forces, and patellofemoral forces under conditions of dynamic knee extension under load in two knee designs with differing quadriceps moment arms. Six human cadaver knees were tested both before implantation and after sequential implantation with two posterior cruciate retaining designs. The extensor moment arm of the LMA (long extensor moment arm design, Scorpio, Howmedica Osteonics, Rutherford, NJ) was approximately 1 cm longer than that of the Control design (7000, Howmedica Osteonics). Quadriceps tension was measured during dynamic closed kinetic chain knee extension. Patellar compressive and shear forces were also recorded using a patellar component instrumented with a custom triaxial load transducer. Knee kinematics were monitored using a three-dimensional electromagnetic tracking device. Both designs produced similar patterns of femoral rollback and tibial rotation. Quadriceps tension was lower in the LMA design compared with the Control design. Patellofemoral compressive forces were also significantly reduced in the LMA design when compared with Control (8-18% lower at angles greater than 50 degrees flexion). The design with the longer extensor moment arm required less quadriceps force to extend the knee under load and reduced patellofemoral compressive forces. Reduced quadriceps forces may facilitate postoperative rehabilitation and activities such as stair climbing. Reduction in patellofemoral forces could reduce patellar complications such as anterior knee pain, component wear, and loosening.

Arthroplasty, Replacement, Knee↗