Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “high throughput”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Visual and computational analysis of structure--activity relationships in high-throughput screening data.

Novel analytic methods are required to assimilate the large volumes of structural and bioassay data generated by combinatorial chemistry and high-throughput screening programmes in the pharmaceutical and agrochemical industries. Recent work in visualisation and data mining has been used to develop structure--activity relationships from such chemical-biological datasets.

Computational Biology↗

Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate.

This paper describes the design and application of instrumentation for automated high-throughput infusion ESI-mass spectrometry. The approach, based on a subatmospheric ESI interface, allows sample introduction from a commercially available microtiter plate without the need for a separate fluid delivery system. The microtiter plate was placed vertically on a three-dimensional translation stage in front of the sampling ESI interface. A single, 7-cm, 20-microm-i.d. fused-silica capillary (total volume, 70 nL), with a tapered tip, served as a combination of sample delivery and spraying capillary. The tapered tip of the capillary was enclosed in a subatmospheric chamber attached in front of the orifice of the mass spectrometer. The sample aspiration rate (flow rate) was regulated by computer-controlled pneumatic valves, which allowed fast switching of the pressure in the subatmospheric ESI chamber. A flow-through wash device was positioned between the microtiter plate and the ESI interface. This design allowed alternate filling of the capillary with (a) sample from the wells and (b) wash solution from the wash device. Sample turnaround times of 10 s/sample, with a 120-nL sample consumption/analysis, and a duty cycle (percentage of total analysis time spent acquiring data) of 40% were achieved. The infusion system was demonstrated in the analysis of preparative HPLC fractions from a small molecule combinatorial library.

Angiotensin I↗

Combined electrospray ionization-atmospheric pressure chemical ionization source for use in high-throughput LC-MS applications.

Fast and accurate analytical methods are essential to keep pace with sample libraries produced from combinational chemistry and high-throughput biological screening. Many laboratories now use a combination of ionization techniques for the characterization of these samples, including atmospheric pressure chemical ionization (APCI), electrospray ionization (ESI), and photoionization (PI). Data are shown here from the analysis of a compound collection plate containing a variety of sample structures. ESI will normally analyze around 80% of these samples, necessitating a source change to analyze a further 10%. In this work, we have developed a new combined ESI-APCI source (ESCi) for use in on-line HPLC applications. The combined source allows alternate on-line ESI and APCI scans with polarity switching within a single analysis. The ESCi source has been designed to be a simple replacement for the existing mass spectrometer interfaces. Each ionization method is optimized independently using separate tuning parameters. Instrument electronics can readily switch between the two ionization methods and polarities within normal interscan time periods. The new source has reduced the analysis time of sample plates by eliminating the need for a source hardware change, source optimization, and repeat analyses.

Journal Article↗

A cell-sparing electric field stimulation technique for high-throughput screening of voltage-gated ion channels.

The Trans Cell Layer Electrical Field Stimulation (TCL-EFS) system has been developed for high-throughput screening (HTS) of voltage-gated ion channels in microplate format on a Voltage-Ion Probe Reader (VIPR) platform. In this design, a wire electrode is placed above the cell layer of each filter well, and a whole plate perimeter electrode resides beneath the filter layer. This configuration allows the electrodes to be placed away from the cell layer to minimize the near electrode field effects on cell function and dye bleaching observed with other existing designs. Mathematical simulation indicates that the electric field at the cell layer becomes uniform as the top electrode is raised to a position near the surface of the solution in the well. Using the TCL-EFS system and membrane potential fluorescence resonance energy transfer (FRET) dyes, the sensitivity of voltage-gated sodium channels to tetrodotoxin and other channel inhibitors was found to be similar to those determined by established electrophysiological and more conventional VIPR techniques. A good correlation was also observed with the TCL-EFS system for inhibition of Cav2.2 by omega-conotoxin-GVIA and for block of Cav1.2 by known small molecule inhibitors. Thus, the TCLEFS system is suitable for both quantitative analysis and HTS of voltage-gated sodium and calcium channels, without the liabilities of previously reported EFS methodologies.

Calcium Channel Blockers↗

High throughput cellular localization of specific plant mRNAs by liquid-phase in situ reverse transcription-polymerase chain reaction of tissue sections.

Advances in high throughput DNA sequencing and bioinformatic gene discovery far outpace our ability to analyze gene function, necessitating development of more efficient means to examine expression at the cellular level. Here we present a polymerase chain reaction-based method to detect mRNA species in situ in which essentially all of the steps are carried out in liquid phase in a 96-well microtiter tray and only the final signal detection is performed on a microscope slide. We demonstrate the sensitivity of the method by the cellular localization of mRNA for the Tkn2 transcription factor in a wide variety of plant tissues, and its selectivity in discriminating a single gene family member by the in situ localization of rbcs3 transcripts. Furthermore, we demonstrate the utility of the in-well in situ method in detecting FDL and IFL1 transcripts in Arabidopsis sections, thus establishing the method as a tool to determine spatial expression pattern of sequences obtained from genomic sequencing projects. Being amenable to robotic processing, in-well in situ reverse transcription-polymerase chain reaction permits a great enhancement in the number of tissue samples that can be processed. Consequently, this method may become a powerful tool for functional genomics studies, permitting the cellular site of transcription of large numbers of sequences obtained from databases to be rapidly established.

Arabidopsis↗

The integration of high throughput technologies for drug discovery.

Producing quality clinical candidates less prone to late stage failure is greatly facilitated by better integration of the relevant high throughput functions and the inclusion of ADME/toxicology further upstream in the discovery process. We describe the tasks and their integration in the context of the design, make and test triad.

Automation↗

Validation of a fluorescent imaging plate reader membrane potential assay for high-throughput screening of glycine transporter modulators.

A fluorescent imaging plate reader (FLIPR) membrane potential (V(m)) assay was evaluated for pharmacological characterization and high-throughput screening (HTS) of rat glycine transporter type 2 (rGlyT(2)) in a stable rGlyT(2)-HEK cell line. Data show that glycine activation of rGlyT(2) consistently results in a concentration-dependent V(m) response on the FLIPR that is blocked by the potent and selective GlyT(2) antagonist 4-benzyloxy-3,5-dimethoxy-N-[1-dimethylamino-cyclopentyl)methyl]-benz-amide (Org-25543). Agonist and antagonist pharmacologies match those reported using conventional [(3)H]glycine uptake assays and electrophysiology. The glycine response is dependent on buffer ionic composition consistent with GlyT(2) physiology. Assay signal-to-background and coefficient of variation meets sufficient statistical criteria to conduct HTS. The results of a screen of the chemical inventory demonstrate that the assay is able to successfully identify and confirm GlyT(2) inhibitors. The advantages of this assay are its homogeneity, compatibility with both 96- and 384-well formats, and lack of radioactivity usage. Thus, the authors conclude that a fluorescence-based V(m) assay on FLIPR is a viable approach for identification and pharmacological profiling of small molecule modulators of the electrogenic transporter rGlyT(2).

Amino Acid Transport Systems, Neutral↗

Development and validation of a high-throughput screen for inhibitors of SARS CoV and its application in screening of a 100,000-compound library.

The authors have developed a high-throughput screen (HTS) that allows for the identification of potential inhibitors of the severe acute respiratory syndrome coronavirus (SARS CoV) from large compound libraries. The luminescent-based assay measures the inhibition of SARS CoV-induced cytopathic effect (CPE) in Vero E6 cells. The assay was validated in 96-well plates in a BSL3 containment facility. The assay is sensitive and robust, with Z values > 0.6, signal to background (S/B) > 16, and signal to noise (S/N) > 3. The assay was further validated with 2 different diversity sets of compounds against the SARS CoV. The "hit" rate for both libraries was approximately 0.01%. The validated HTS assay was then employed to screen a 100,000-compound library against SARS CoV. The hit rate for the library in a single-dose format was determined to be approximately 0.8%. Screening of the 3 libraries resulted in the identification of several novel compounds that effectively inhibited the CPE of SARS CoV in vitro-compounds which will serve as excellent lead candidates for further evaluation. At a 10-microM concentration, 3 compounds with selective indexes (SI50) of > 53 were discovered.

Animals↗

Design of a microsphere-based high-throughput gene expression assay to determine estrogenic potential.

Recently gene expression studies have been multiplied at an accelerated rate by the use of high-density microarrays. By assaying thousands of transcripts at a time, microarrays have led to the discovery of dozens of genes involved in particular biochemical processes, for example, the response of a tissue/organ to a given chemical with therapeutic or toxic properties. The next step in these studies is to focus on the response of a subset of relevant genes to verify or refine potential therapeutic or toxic properties. We have developed a sensitive, high-throughput gene expression assay for this purpose. In this assay, based on the Luminex xMAP system, carefully selected oligonucleotides were covalently linked to fluorescently coded microspheres that are hybridized to biotinylated cRNA followed by amplification of the signal, which results in a rapid, sensitive, multiplexed assay platform. Using this system, we have developed an RNA expression profiling assay specific for 17 estrogen-responsive transcripts and three controls. This assay can evaluate up to 100 distinct analytes simultaneously in a single sample, in a 96-well plate format. This system has improved sensitivity versus existing microsphere-based assays and has sensitivity and precision comparable with or better than microarray technology. We have achieved detection levels down to 1 amol, detecting rare messages in complex cRNA samples, using as little as 2.5 microg starting cRNA. This assay offers increased throughput with decreased costs compared with existing microarray technologies, with the trade-off being in the total number of transcripts that can be analyzed.

Animals↗

High-throughput DNA extraction from old paraffin-embedded biopsies.

We have developed a rapid and reliable microporous spin-column-based method for high-throughput extraction of DNA from old paraffin-embedded biopsies. The method was developed specifically for PCRs and molecular genetic studies. De-waxing and DNA extraction from tissues is performed in only one vessel, minimizing pipetting steps and eliminating supernatant/pellet procedures. All steps are performed at 60 degrees, 55 degrees and 95 degrees C minimize deleterious DNase activity. The amount of the extracted DNA was measured spectrophotometrically, and the quality of the extracted DNA and the PCR products was controlled on ethidium bromide-stained 3% agarose gel. The presented method for DNA extraction is less laborious and more convenient than previously published methods. It provides means by which extensive, paraffin-embedded material can be subjected to molecular genetic studies.

Actins↗

A novel histone deacetylase inhibitor identified by high-throughput transcriptional screening of a compound library.

Libraries of compounds are increasingly becoming commercially available for the use of individual academic laboratories. A high-throughput system based on a stably integrated transcriptional reporter was used to screen a library of random compounds to identify agents that conferred robust augmentation of a signal transduction pathway. A novel histone deacetylase (HDAC) inhibitor, termed scriptaid, conferred the greatest effect, a 12- to 18-fold augmentation. This facilitation of transcriptional events was generally applicable to exogenous gene constructs, including viral and cellular promoters, different cell lines and reporter genes, and stably integrated and transiently introduced sequences. Scriptaid did not interfere with a further induction provided by stimulation of the cognate signal transduction pathway (transforming growth factor beta/Smad4), which implied the functional independence of ligand-stimulated transcriptional activation and histone acetylation states in this system. Additional insights into this and other signal transduction systems are likely to be afforded through the application of compound screening technologies.

Cell Survival↗

[Small but high throughput: how "tissue-microarrays" became a favorite tool for pathologists and scientists].

Progress in the knowledge of molecular genetics and availability of high-throughput technologies offer the opportunity to identify new diagnostic and prognostic markers and new therapeutic targets in human cancer. The recently developed "tIssue microarrays" (TMA) technology allows parallel molecular profiling of clinical samples. Using this technique and immunohistochemistry (IHC), fluorescence in situ hybridisation (FISH), or RNA in situ hybridisation (ISH), the pathologist is now able to perform unprecedented large-scale analyses. The advantages are significant: large number of cases assessed simultaneously for numerous markers, processed in identical conditions, from reduced amount of archival tIssues, with an excellent correlation with standard methods, and a reduction in cost and time. This Article provides a short review of this technology, and points out several aspects of the TMA construction and its applications for clinical research.

Biomarkers↗

Identifying protein complexes in high-throughput protein interaction screens using an infinite latent feature model.

We propose a Bayesian approach to identify protein complexes and their constituents from high-throughput protein-protein interaction screens. An infinite latent feature model that allows for multi-complex membership by individual proteins is coupled with a graph diffusion kernel that evaluates the likelihood of two proteins belonging to the same complex. Gibbs sampling is then used to infer a catalog of protein complexes from the interaction screen data. An advantage of this model is that it places no prior constraints on the number of complexes and automatically infers the number of significant complexes from the data. Validation results using affinity purification/mass spectrometry experimental data from yeast RNA-processing complexes indicate that our method is capable of partitioning the data in a biologically meaningful way. A supplementary web site containing larger versions of the figures is available at http://public.kgi.edu/wild/PSBO6/index.html.

Algorithms↗

A rational utilization of high-throughput screening affords selective, orally bioavailable 1-benzyl-3-carboxyazetidine sphingosine-1-phosphate-1 receptor agonists.

Moderately potent, selective S1P(1) receptor agonists identified from high-throughput screening have been adapted into lipophilic tails for a class of orally bioavailable amino acid-based S1P(1) agonists represented by 7. Many of the new compounds are potent S1P(1) agonists that select against the S1P(2), S1P(3), and S1P(4) (although not S1P(5)) receptor subtypes. Analogues 18 and 24 are highly orally bioavailable and possess excellent pharmacokinetic profiles in the rat, dog, and rhesus monkey.

Administration, Oral↗

Algorithmic approach to high-throughput molecular screening for alpha interferon-resistant genotypes in hepatitis C patients.

This study was designed to analyze the feasibility and validity of using Cleavase Fragment Length Polymorphism (CFLP) analysis as an alternative to DNA sequencing for high-throughput screening of hepatitis C virus (HCV) genotypes in a high-volume molecular pathology laboratory setting. By using a 244-bp amplicon from the 5' untranslated region of the HCV genome, 61 clinical samples received for HCV reverse transcription-PCR (RT-PCR) were genotyped by this method. The genotype frequencies assigned by the CFLP method were 44.3% for type 1a, 26.2% for 1b, 13.1% for type 2b, and 5% type 3a. The results obtained by nucleotide sequence analysis provided 100% concordance with those obtained by CFLP analysis at the major genotype level, with resolvable differences as to subtype designations for five samples. CFLP analysis-derived HCV genotype frequencies also concurred with the national estimates (N. N. Zein et al., Ann. Intern. Med. 125:634-639, 1996). Reanalysis of 42 of these samples in parallel in a different research laboratory reproduced the CFLP fingerprints for 100% of the samples. Similarly, the major subtype designations for 19 samples subjected to different incubation temperature-time conditions were also 100% reproducible. Comparative cost analysis for genotyping of HCV by line probe assay, CFLP analysis, and automated DNA sequencing indicated that the average cost per amplicon was lowest for CFLP analysis, at $20 (direct costs). On the basis of these findings we propose that CFLP analysis is a robust, sensitive, specific, and an economical method for large-scale screening of HCV-infected patients for alpha interferon-resistant HCV genotypes. The paper describes an algorithm that uses as a reflex test the RT-PCR-based qualitative screening of samples for HCV detection and also addresses genotypes that are ambiguous.

Algorithms↗

High-throughput screening and quantitative structure-efficacy relationship models of potential displacer molecules for ion-exchange systems.

A technique is presented for the high-throughput screening of ion-exchange displacers. Potential displacers were employed to displace proteins in parallel batch ion-exchange experiments. The percentage of protein displaced from a particular stationary phase was then used as a parameter to rank the displacers. By employing this technique, a large number of molecules possessing a range of affinities and properties could be rapidly evaluated. This data was then used together with traditional and electron density-based transferable atom equivalent (TAE) molecular descriptors computed for the displacer molecules to produce quantitative structure-efficacy relationship (QSER) models using a genetic algorithm/partial least squares (GA/PLS) regression approach. The QSER models were generated using a portion of the protein-displacement data, with the remainder serving as a test set. Descriptor selection and model building was accomplished using a genetic algorithm/partial least squares approach. The resulting models were found to have high-correlation coefficients and could be used to accurately predict the behavior of molecules not included in the training set. In addition, the models were employed to examine a virtual library of displacers based on modifications of neomycin to provide further insight into displacer design. The results presented here indicate that it may be possible to design displacers that can dramatically improve the effective selectivity of ion-exchange chromatographic materials.

Algorithms↗

High throughput HLA sequence-based typing (SBT) utilizing the ABI Prism 3700 DNA Analyzer.

AIMS AND BACKGROUND: The genetic complexity of the human major histocompatibility complex (MHC) has required the development of various molecular typing methods. The purpose of this paper is to compare the results of two of these molecular methods: sequenced based typing (SBT) and polymerase chain reaction (PCR) using sequence specific primers (PCR-SSP). METHODS: The SBT method described utilizes an ABI Prism 3700 DNA Analyzer, which has been designed fro high throughput production of sequence data through highly automated operation with significant walk-away time. The ABI Prism 3700 DNA Analyzer is a 96-capillary electrophoresis instrument with the capability of running four 96-well plates black to back in a sixteen-hour period. Potentially, data from this machine can produce Class I sequences for A or B loci for 64 samples in this time frame. The SBT method encompassed exons 2, 3, and 4 with forward and reverse sequence orientation reactions using the PE Biosystems HLA-A and HLA-B Sequenced Based Typing Kits (PE Applied Biopsystems/Perkin-Elmer, Foster City, CA, USA). Most SBT methods previously employed only gather data from exons 2 and 3 which distinguishes most of the polymorphism necessary to identify the majority of alleles in the HLA region. However, in an effort to discern numerous null alleles in the HLA region, exon 4 data is also included. The PCR-SSP method utilized consists of one 96 well tray, with 95 primer mixes and one negative control, per sample designed to produce an intermediate/high resolution HLA-A, B typing. RESULTS: Data from one 96-well capillary run on the ABI Prism 3700 DNA Analyzer, which consists of results from 16 samples for HLA-A or HLA-B loci, was compared to data derived from sixteen HLA-A and HLA-B PCR-SSP typings. 75% of loci tested achieved a higher resolution HLA typing by the SBT method. DISCUSSION: The ability to provide allele level HLA typing results can have significant functional implications for the bone marrow transplant community and numerous vaccine studies.

DNA↗

A homogeneous, high-throughput fluorescence resonance energy transfer-based DNA polymerase assay.

A homogeneous, fluorescence resonance energy transfer (FRET)-based DNA polymerase assay that is suitable for high-throughput screening for inhibitors, and can also be used for steady-state kinetic investigations, is described. The activity, kinetic mechanism, and processivity of the isolated alpha subunit of DNA polymerase III, the product of the dnaE gene, from the gram-negative pathogen Haemophilus influenzae were investigated using the FRET assay.

Base Sequence↗