Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PATENTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

A video-assisted thoracoscopic surgical technique for interruption of patent ductus arteriosus.

We describe herein a technique for patent ductus arteriosus (PDA) closure using a method of video-assisted thoracoscopic surgical (VATS) interruption derived from video-assisted endoscopic surgery. This technique of repair was performed on five patients with a mean age of 3 years and a mean weight of 13.7 kg during 1994 and 1995. Under general anesthesia, two 10-mm trocars and two or three 5-mm trocars were inserted through the left thoracic wall. A video camera and specially designed surgical tools including scissors, dissectors, and a clip applicator were then introduced. The ductus was dissected, and two titanium clips were applied to interrupt the ductus completely. Successful closure of the PDA by this video-assisted technique was achieved in all patients. The only complication which developed in one patient was hoarseness for 2 weeks postoperatively. The hospital stay ranged from 7 to 12 days and there were no serious complications or deaths. There results indicate that video-assisted thoracoscopic surgical interruption is a safe and effective technique for achieving closure of PDA.

Child, Preschool↗

Precordial contrast echocardiographic detection of patent ductus arteriosus in small preterm infants.

Clinical detection of patent ductus arteriosus (PDA) remains an important and challenging problem in the small preterm infant with respiratory distress. In this study, PDA was diagnosed in 28 small preterms using an improved contrast echocardiographic method. In these infants, the injection of saline into the aorta generated echoes which were imaged at the pulmonary valve. This was accomplished using a conventional M-mode ultrasound transducer applied at the usual precordial position. Contrast echo studies were compared with the degree of ductal patency shown by single film aortography. Ductal patency was detected by contrast echo in 29 of 31 instances of aortographically proven PDA. Indirect echo indices commonly used for detection of PDA (cardiac chamber enlargement) may be limited since factors other than left-to-right shunt can cause cardiac enlargement in distressed small preterms. This direct contrast echo technique is an easily performed, sensitive, qualitative method for confirmation of the diagnosis of PDA in small preterm infants.

Aortography↗

Ligation of medically refracted patent ductus arteriosus (PDA) in an extremely low body weight premature infant.

Medically refracted patent ductus arteriosus (PDA) in an extremely low birth weight (ELBW) preterm (gestation 24 weeks 2 days) infant was successfully ligated under general anesthesia in the neonatal intensive care unit (NICU). Pharmacological agents are more effective to close PDA in preterm infants than in full-term infants, although within 48 h three doses of indomethacin were not sufficient to close PDA in this case. At the age of 69 h the infant developed severe symptoms including bradycardia, systemic hypotension, pulmonary hypertension, diastolic steal (reverse distal aorta flow velocity), and anuria. A PDA ligation was thus performed surgically at 72 h of age. General anesthesia and surgical stress were tolerated by this 531 g infant. Postoperatively all symptoms improved dramatically and the general conditions were stable. On the 38th day the endotracheal tube was extubated and on the 50th day nasogastric milk feeding was started. The oxygen supply was weaned on the 78th day. Growth and development until 6 months were within the normal range of very low birth weight infants. A surgical ligation as early as possible in medically refracted PDA in an ELBW infant is thus considered to be a safe and effective treatment. It prevents the development of further complications of cardiopulmonary vascular problems. Color Doppler echocardiography can reliably measure the PDA size, flow velocity, and hemodynamic changes of persistent PDA, even in tiny infants.

Ductus Arteriosus, Patent↗

Transcatheter vascular occlusion of the small patent ductus arteriosus: an alternative method.

The current strategies concerning a small (</=2 mm) patent ductus arteriosus (PDA) include surgical ligation, transcatheter implantation of the Rashkind occluder device, or no intervention requiring indefinite endocarditis precautions. Five patients have undergone successful transcatheter closure of a small-caliber PDA utilizing a single 3 mm Gianturco occluder coil as an alternative to surgical ligation. The coil was delivered to traverse the narrowest dimension of the PDA, leaving loops of coil in both the pulmonary and aortic ends of the ductus. All PDAs were successfully occluded, and the duration of hospitalization for all patients was 1 day. At latest follow-up (11 +/- 2 months), echocardiography demonstrates complete ductus occlusion in all patients, with no obstruction to left pulmonary arterial or descending aortic flow. Transcatheter coil occlusion of the small ductus is an easily accomplished, safe, effective alternative to surgical ligation, thereby avoiding a lateral thoracotomy incision, shortening hospitalization, and reducing costs.

Aorta, Thoracic↗

Occlusion of the neonatal patent ductus arteriosus with a simple retrievable device: a feasibility study.

PURPOSE: To examine the feasibility of transvenous placement of a new memory-shaped, small, retrievable coil that has a smaller-caliber delivery system than currently available devices, for closure of the patent ductus arteriosus (PDA). METHODS: Through 4 or 5 Fr vascular sheaths and 4 or 5 Fr end-hold catheters, the coils were delivered and placed in piglets (n = 10) with PDA. The coils were made from 0.018" (0.46 mm) or 0.028" (0.71 mm) stainless steel guidewire. Mounted for delivery, the new device has the appearance of a conventional guidewire. This neonatal PDA model was created without major surgery or drugs by stenting the ductus arteriosus. RESULTS: The memory-shaped coils were easily delivered. Coils not optimally placed were retrieved and repositioned. Occlusion of the ductus arteriosus as early as a half-hour after delivery was shown angiographically and confirmed by histopathology. CONCLUSION: This new, small-caliber, simple device was found to be effective for closure of the PDA in this animal model. Longer-term observations are needed.

Animals↗

Transluminal closure of patent ductus arteriosus: long-term results of 208 cases treated without thoracotomy.

Patent ductus arteriosus was the first inborn cardiac defect ever eliminated by percutaneous transvascular therapy. The method, results, and complications of Ivalon plugging of the ductus in 208 patients between 5 and 62 years old and treated between 1967 and 1985 are described. Permanent closure was accomplished in 197 patients (94.7%). The following particular benefits are obtainable from the method: no need for thoracotomy; local anesthesia applicable to 65% of all cases; 30 mm average time of intervention; only moderate invasiveness to the patients; only 7 days of hospitalization; good cost-benefit ratio.

Adolescent↗

Patent ductus arteriosus in preterm neonates.

Failure of the ductus arteriosus to close within 48-96 hours of postnatal age results in a left to right shunt across the ductus and overloading of the pulmonary circulation. This is more likely to happen in premature neonates with respiratory distress syndrome. Deterioration in the respiratory status on day 3-4 in a ventilated neonate and unexplained metabolic acidosis may be the earliest indicators of a patent ductus arteriosus (PDA). Indomethacin is the main stay of medical management of PDA in preterm neonates. Guidelines for administration of indomethacin have been described in the protocol. Restricted fluid therapy may be beneficial in the prevention of PDA in preterm neonates. Presence of PDA in a term neonate should be investigated to rule out an underlying congenital heart disease.

Cyclooxygenase Inhibitors↗

Review and patents and literature. The use of insect cell cultures for recombinant protein synthesis: Engineering aspects.

The use of the insect cell/baculovirus expression system for producing recombinant proteins of bacterial, plant, insect, and mammalian origin has become widespread. The popularity of this eukaryotic expression system is due to many factors, including (1) potentially high protein expression levels, (2) ease and speed of genetic engineering, (3) ability to accommodate large DNA inserts, (4) protein processing similar to higher eukaryotic cells (e.g., mammalia cells), and (5) ease of insect cell growth (e.g., suspension growth). The following review of the literature discusses two engineering aspects of recombinant protein synthesis by insect cell cultures: bioreactor scale-up and insect cell line selection. Following this review patent abstracts and additional literature pertaining to expression of recombinant proteins in insect cell culture are listed.

Animals↗

The anaesthetic management of preterm infants undergoing ligation of patent ductus arteriosus.

The authors reviewed the records of seventy preterm infants suffering from respiratory distress syndrome and, in most cases, refractory congestive heart failure, who underwent ligation of patent ductus arteriosus. The peri-operative management of these patients is described. The anaesthetic technique consisted of nitrous oxide and oxygen supplemented with a relaxant. All patients were ventilated manually with a humidified Jackson Rees system. The operations were performed in the main operating suite. There were no deaths during operation. The infants were protected from significant temperature fluctuations by various methods which are described. The overall survival rate of all preterm infants with respiratory distress syndrome. The management presented is considered acceptable to the infants, to the surgeons and to the anaesthetists.

Anesthesia, General↗

Transoesophageal echocardiography detects residual ductal flow during video-assisted thoracoscopic patent ductus arteriosus interruption.

This report describes transoesophageal echocardiographic (TEE) monitoring in a one-year-old boy undergoing patent ductus arteriosus (PDA) interruption. After application of a first vascular clip, echocardiographic monitoring detected incomplete interruption of ductal flow, prompting the surgeon to add a second clip to the ductus. The procedure was performed via a new surgical technique: video-assisted thoracoscopic surgery (VATS). This innovative approach offers many advantages to patient care including reduced postoperative pain and better preservation of pulmonary function. We conclude that the use of TEE monitoring during PDA interruption via the VATS procedure may improve the surgical result, and eliminate reintervention and the complications associated with residual ductal flow.

Ductus Arteriosus, Patent↗

Transcatheter occlusion of the patent ductus arteriosus: a comparison of two devices.

BACKGROUND: Transcatheter occlusion of the arterial duct is a safe and effective alternative to surgical closure. The Rashkind umbrella occluder and the Cook coil are two established devices, although the former is no longer manufactured. AIMS: To assess any difference in outcomes between the use of the Cook detachable coil and the Rashkind double umbrella in patent ductus arteriosus (PDA) occlusion. METHODS: A retrospective study of 77 patients in whom PDA occlusion was attempted using the Cook detachable PDA coil from March 1996 to March 2000. A comparison was carried out with patients in whom occlusion was attempted using the Rashkind double umbrella between 1989 and 1996. RESULTS: The rate of immediate complete occlusion was 24% compared with 29.9% for the Rashkind device. The figure for complete occlusion after 24 hours with the PDA coil was 63% compared with 61.5% in the Rashkind group (p > 0.1). The overall closure rate in the coil group was 72% versus 74.6% for umbrellas. CONCLUSION: The outcome in terms of complete duct closure using the Cook coil is comparable with figures obtained using the Rashkind umbrella. Both devices have a good safety profile in the short and medium-terms.

Cardiac Catheterization↗

[Percutaneous transcatheter coil embolization of the patent ductus arteriosus for elderly patient with left ventricular disfunction].

We performed the coil embolization for 64-year-old male with patent ductus arteriosus and left ventricular dysfunction. We used "snare method" and "cross catheter technique" delivering one coil transvenously and one coil transarterially. Echocardiograms at 7 month after the procedure demonstrated complete occlusion of the ductus, though small shunt was detected at discharge.

Catheterization, Peripheral↗

[Surgical management of patent ductus arteriosus in low body weight infants].

Between January 1980 and December 1994, seventeen premature infants weighing less than 2500 g underwent surgical management for the isolated patent ductus arteriosus (PDA). Indometacine therapy for closure of PDA was not effective for all these patients. In terms of the body weight at birth, they were divided into two groups; Group I (G-I) consisted of ten patients with birth weight less than 1000 g and Group II (G-II) of seven patients weighing more than 1000 g. The age at operation was 22.1 +/- 15.4 days in the G-I and 14.3 +/- 11.4 days in the G-II. The ductus was ligated in all patients but one of the G-II, in whom it was divided. There were five (50%) hospital deaths in the G-I and none in the G-II. The causes of death in the G-I were related to necrotizing enterocolitis (NEC) in two and infant respiratory distress syndrome (IRDS), acute renal failure, and broncho-esophagial fistula in each. The age at operation tended to be older in nonsurvivors rather than in survivors in the G-I (28.0 +/- 16.8 days vs. 16.2 +/- 14.0 days, respectively, but the difference did not reach significance). Before surgery, all patients in the G-I required mechanical ventilator support and nine of them were associated with IRDS. In contrast, only two patients in the G-II needed mechanical ventilation preoperatively. The postoperative period of intubation was also significantly longer in the G-I than in the G-II (51.6 +/- 35.2 days vs. 2.2 +/- 1.5 days, respectively, p < 0.05). In conclusions, the surgery for PDA can be safely performed even in small premature babies weighing less than 1000 g. When medical therapy for PDA is not effective in the premature patients, the surgical management should be considered as early as possible before their conditions become worse due to such critical complications as NEC, IRDS, and renal failure.

Cardiac Surgical Procedures↗

Fixation principles in metaphyseal bone--a patent based review.

Osteoporotic changes start in cancellous bone due to the underlying pathophysiology. Consequently, the metaphyses are at a higher risk of "osteoporotic" fracture than the diaphysis. Furthermore, implant purchase to fix these fractures is also affected by the poor bone quality. In general, researchers and developers have worked on three different approaches to address the problem of fractures to osteoporotic bone: adapted anchoring techniques, improved load distribution as well as transfer with angular stable screws, and augmentation techniques using bone substitutes. A patent-based review was performed to evaluate which ideas were utilized to improve fixation in osteoporotic, metaphyseal bone, especially in the proximal femur, and to analyze whether the concept had entered clinical use. Anchoring devices that are either extramedullary or intramedullary have a long clinical history. However, demanding surgical techniques and complications, especially in poor quality bone, are justification that such implants and their corresponding surgical techniques need to be improved upon. Expanding elements have been evaluated in the laboratory. The results are promising and the potential of this approach has yet to be fully exploited in the clinics. Internal fixators with angular stable screws open the door for many new anchorage ideas and have great potential for further optimization of load distribution and transfer. Augmentation techniques may improve anchorage in osteoporotic bone. However, the properties of bone substitute materials will need to be modified and improved upon in order to meet the demanding requirements. If we summarise the development process and the clinical use of implants to date, we have to clearly state that more factors than simply biomechanical advantage will determine the clinical success of a new fixation principle or a new implant. Instead, fracture treatment of patients with osteoporosis really needs an interdisciplinary approach!

Bone Nails↗

Percutaneous transaortic occlusion of patent ductus arteriosus using a new versatile angiographic and delivery catheter.

We evaluated the usefulness of patent ductus arteriosus (PDA) occlusion using a new catheter that combines good angiographic properties, easy manipulation across the duct, documentation of aortic and pulmonary artery pressure, and coil delivery for percutaneous transaortic ductal occlusion. Thirty patients (13 females and 17 males) who met the clinical and echocardiographic criteria for the percutaneous closure of PDA were catheterized. The patients selected for this study had a small to moderate PDA with a conal or tubular shape, adequate aortic ampula, and normal or mildly elevated pulmonary artery pressure. The median age was 4.8 years (range, 10 months-20 years). Patients were catheterized by the transaortic approach using the new angiographic and coil delivery catheter specially designed for this procedure. A PDA was closed in every case. A single DuctOcclud pfm coil was delivered in 28 patients, and 2 patients had NitOcclud pfm coils for ductal occlusion. The screening time was measured and found to be 50% less than the measured screening time using other catheters in our laboratory. Only one catheter and one guidewire were used per procedure, with no need for exchange wires or the establishment of an arteriovenous loop. The procedure time was also reduced by 50%. A minimal residual shunt, demonstrated by color-flow Doppler mapping, was present in 2 patients. The new combined angiographic and coil delivery catheter is most suitable for transaortic PDA coil occlusion, significantly decreasing the procedure and screening time.

Adolescent↗