Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Direct detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Write and Read: Harnessing Synthetic DNA Modifications for Nanopore Sequencing.

An exciting feature of nanopore sequencing is its ability to record multi-omic information on the same sequenced DNA molecule. Well-trained models allow the detection of nucleotide-specific molecular signatures through changes in ionic current as DNA molecules translocate through the nanopore. Thus, naturally occurring DNA modifications, such as DNA methylation and hydroxymethylation, may be recorded simultaneously with the genetic sequence. Additional genomic information, such as chromatin state or the locations of bound transcription factors, may also be recorded if their locations are chemically encoded into the DNA. Here, we present a versatile "write-and-read" framework, where chemo-enzymatic DNA labeling with unnatural synthetic tags results in predictable electrical fingerprints in nanopore sequencing. As a proof-of-concept, we explore a DNA glucosylation approach that selectively modifies 5-hydroxymethylcytosine (5hmC) with glucose or glucose-azide adducts. We demonstrate that these modifications generate distinct and reproducible electrical shifts, enabling the direct detection of chemically altered nucleotides. We further demonstrate that enzymatic alkylation, such as the enzymatic transfer of azide residues to the N6 position of adenines, also produces characteristic nanopore signal shifts relative to the native adenine and 6-methyladenine. Beyond direct nucleotide detection, this approach introduces new possibilities for bio-orthogonal DNA labeling, enabling an extended alphabet of sequence-specific detectable moieties. The future use of programmable chemical modifications for simultaneous analysis of multiple omics features on individual molecules opens new avenues for genetic research and discovery.

5-hydroxymethylcytosine (5hmC)↗

Affibody molecules in protein capture microarrays: evaluation of multidomain ligands and different detection formats.

The importance of the ligand presentation format for the production of protein capture microarrays was evaluated using different Affibody molecules, produced either as single 6 kDa monomers or genetically linked head-to-tail multimers containing up to four domains. The performances in terms of selectivity and sensitivity of the monomeric and the multidomain Affibody molecules were compared by immobilization of the ligands on microarray slides, followed by incubation with fluorescent-labeled target protein. An increase in signal intensities for the multimers was demonstrated, with the most pronounced difference observed between monomers and dimers. A protein microarray containing six different dimeric Affibody ligands with specificity for IgA, IgE, IgG, TNF-alpha, insulin, or Taq DNA polymerase was characterized for direct detection of fluorescent-labeled analytes. No cross-reactivity was observed and the limits of detection were 600 fM for IgA, 20 pM for IgE, 70 fM for IgG, 20 pM for TNF-alpha, 60 pM for insulin, and 10 pM for Taq DNA polymerase. Also, different sandwich formats for detection of unlabeled protein were evaluated and used for selective detection of IgA or TNF-alpha in human serum or plasma samples, respectively. Finally, the presence of IgA was determined using detection of directly Cy5-labeled normal or IgA-deficient serum samples.

Biotinylation↗

Enzyme immunoassay for the detection of Giardia lamblia.

An enzyme immunoassay (EIA) was developed for direct detection of Giardia lamblia antigens in fecal specimens. The EIA was evaluated by testing specimens from 1,331 subjects in the USA and Egypt. For the 353 specimens from human subjects in the USA there was a 97% overall agreement between the results of the EIA and direct microscopic examination, yielding a sensitivity and specificity of 92% and 99% respectively. Due to adverse field conditions the EIA did not perform as well in the specimens collected and tested in Egypt. The sensitivity and specificity for 585 human specimens from Egypt were 74% and 97% respectively.

Animals↗

Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode.

Direct detection of ephedrines and other underivatized amino compounds (amines, alicyclic amines, alkanolamines, and amino acids) can be carried out via electrocatalytic oxidation at a carbon paste electrode (CPE) modified with cobalt phthalocyanine (CoPC) in alkaline solution (0.10 mol L-1 NaOH). Most of the amino compounds tested could be determined using the CoPC/CPE in an amperometric flow detector. The analytical signal of ephedrine was stabilised by alternating the potential between an anodic detection potential of +0.30 V (+0.45 V for other amino compounds) applied for 220 ms and a cathodic reactivation potential of -0.30 V applied for 100 ms (potentials versus SCE). The linear response range for ephedrine was within 1-100 mumol L-1 and the detection limit was 0.8 mumol L-1 with a 100 microL sample loop and a typical sampling ra 60 h-1. The signal (oxidation peak current) reproducibility was 2-3%. The method was applied to the determination of ephedrine in pharmaceutical formulations with results comparable to those obtained with a standard spectrophotometric method.

Carbon↗

Sensitive detection of Escherichia coli O157:H7 by conventional plating techniques.

The direct detection and estimation of concentration of Escherichia coli O157:H7 down to 1 CFU/g of cheese was achieved by conventional plating techniques. Cheese was manufactured with unpasteurized milk inoculated with E. coli O157: H7 at 34 +/- 3 CFU/ml. The numbers of E. coli O157:H7 were monitored during cheese ripening by plating on sorbitol MacConkey agar supplemented with cefixime and potassium tellurite (CT-SMAC) and on CT-O157:H7 ID medium. Using the pour plate method, E. coli O157:H7 colonies could easily be distinguished from non-O157:H7 colonies on CT-O157:H7 ID medium but not on CT-SMAC. Higher numbers of E. coli O157:H7 were detectable with O157:H7 ID medium. Latex agglutination and PCR were used to confirm the identification of typical E. coli O157:H7 colonies, and nontypical colonies as not being E. coli O157:H7. As few as 1 CFU/g of cheese could be detected. E. coli O157:H7 also was detected in deliberately contaminated milk at concentrations as low as 4 CFU/10 ml.

Cheese↗

Rapid viral diagnosis.

There has been much interest and activity in the development of techniques for rapid viral diagnosis which would allow successful intervention in the treatment of patients or their contacts or in the control of viral diseases in the community. The greatest emphasis has been on techniques that permit viral detection directly in the clinical specimen, since these avoid the need to cultivate the agent, are feasible for detection of viruses that cannot be cultivated, and can detect virus in specimens in which the agent is no longer infectious. Direct methods used for viral detection include electron microscopy and various immunoassays which are based on demonstrating reactivity of viral antigen in the specimen with known viral antisera. The use of immunoassays for more rapid identification of viruses isolated in laboratory host systems and for selective detection of viral antigen in inoculated cell cultures even before the agents produce an observable effect has been an important advance in viral diagnosis by the approach of isolation and identification. The reliability of all specific viral identification procedures depends on the use of high quality viral antisera. Some of the problems previously encountered in preparing satisfactory viral immune reagents are being overcome through the availability of highly specific monoclonal antibodies produced by cell hybridization techniques. Virus-specific IgM antibody assays for rapid diagnosis have been improved greatly through the use of a "capture" technique in which antibody to the human mu chain is used in the solid phase to separate IgM from other serum components which might compete with IgM antibody or give nonspecific reactivity, and also through the availability of highly specific monoclonal antibodies to the human mu chain. A variety of simple assays for determination of viral antibody status have been developed, and many are commercially available. The reliability of some of these antibody assays has been improved through the incorporation of more suitable controls and through better definition of interpretations which should be made from test results.

Antibodies, Monoclonal↗

Immunoassay for serologic diagnosis of influenza type A using recombinant DNA produced nucleoprotein antigen and monoclonal antibody to human IgG.

Influenza type A nucleoprotein (NP) derived from the full length cloned gene expressed in E. coli was evaluated in a solid phase enzyme immunoassay (EIA) for detection of human antibody to influenza. Monoclonal antibody to human IgG was used for detection. Direct and indirect assays were developed and sera were tested in serial and single dilution formats. Preliminary results indicated that recombinant-and virion-derived NP antigens were comparable in binding ability to plastic and binding human antibody. Eighty-seven paired sera from influenza patients were tested. The most sensitive assay (indirect-serial dilution) detected 56 (64%) rises and the simplest assay (direct-single dilution) detected 43 (49%) rises, compared to 36 (41%) for complement fixation. Paired sera from 18 control patients showed no evidence of antibody rises by any of the assays. Forty-nine paired sera from influenza B infected patients were negative for antibody rises except for one borderline rise by the indirect-serial dilution assay. These results indicate that the use of recombinant DNA derived nucleoprotein for immunoassay is feasible. The sensitivity of immunoassays using NP adsorbed to the solid phase and monoclonal antibody specific for human IgG to detect bound antibody exceeded that of conventional complement fixation testing for establishing serologic evidence of influenza type A infection.

Antibodies, Monoclonal↗

Nonspecific velocity and amplitude hunting reveals different specific detection performance of flexion and extension movements in the human knee joint.

A debate exists in the literature as to what extent perception is conscious. In some publications regarding proprioception, the term proprioception has explicitly only been seen as properly used when subjects were able to report the imposed movement's direction. Detections of movements without movement-direction perception, have been seen as nonspecific. Since a lot of studies discussed this point but never tested it explicitly, we tested it by using nonspecific hunting paradigms (only the occurrence of a movement has to be detected, not its direction) with the following rationale. If the perception performance is really nonspecific, no difference regarding the movement's direction should be found. Thus, if we found a different detection performance regarding flexion and extension by means of a nonspecific paradigm, it would demonstrate that this "nonspecific" perception is already specific. Therefore, we measured the perception characteristics separately for flexion and extension. The perception characteristics have been determined from the amplitude-velocity-relation curve. Two different, nonspecific hunting paradigms, modifications of our previously published specific hunting paradigm, have been used. Thus, we determined pairs of threshold values, regarding amplitude hunting using three different angular velocities (0.1 degrees s(-1), 0.25 degrees s(-1), and 0.5 degrees s(-1)) and regarding velocity hunting using three different angular displacements (0.25 degrees, 0.5 degrees, and 1 degrees) as well, for flexion and extension, respectively. We found that both threshold paradigms (velocity hunting and amplitude hunting) revealed the same perception characteristics for a given movement direction. With an increasing angular velocity, angular displacement threshold values converged toward a common value for flexion and extension (about 0.2 degrees); with an increasing angular displacement, angular velocity threshold values converged toward separate values for flexion (about 0.06 degrees s(-1)) and extension (about 0.1 degrees s(-1)). Thus, our findings demonstrate that detection performance is specific and not bound to conscious perception, since specific thresholds for flexion and extension were revealed with nonspecific hunting paradigms.

Adult↗

Detection of Aeromonas salmonicida from fish by using polymerase chain reaction amplification of the virulence surface array protein gene.

A DNA-based assay was developed to detect Aeromonas salmonicida from infected fish by analyzing tissues, feces, and the tank water in which the infected fish were held. This analysis was done both by direct detection from samples and after a bacterial outgrowth step. Polymerase chain reaction (PCR) amplification of a 421-bp sequence from the 3' region of the surface array protein gene (vapA) of A. salmonicida provided a specific and sensitive method for the detection and identification of this important fish pathogen. The sensitivity of PCR detection of A. salmonicida directly from tissues was less than 10 CFU/mg. Furthermore, a detection level of 5 fg, equivalent to approximately 1 cell, was obtained by using purified chromosomal DNA as the template. This highly reproducible assay, which requires 45 min to complete, is therefore sensitive enough to be used as a noninvasive method for monitoring fish populations for the presence of carrier fish. Because the surface protein array (A-layer) is a virulence factor of A. salmonicida, PCR analysis with oligonucleotide primers directed at vapA can also be used to provide information on the potential virulence of a strain.

Aeromonas↗

Characterization and quantification of organic anions with capillary zone electrophoresis using direct and indirect detection.

A comparison of the separation and quantification capabilities of capillary zone electrophoresis (CZE) using direct and indirect detection of organic anions was conducted. A conventional CZE separation (normal polarity, electroosmotic flow toward the cathode) of phenol, benzoic acid, and 2,4-dihydroxybenzoic acid utilized direct UV absorption at 215 nM. A separation of myo-inositol 1,4,5-trisphosphate and myo-inositol hexakisphosphate utilizing a reversed polarity and an electroosmotic flow modifier (flow toward the anode) was monitored by indirect UV absorption at 250 nM. The separation buffers utilized in this study consisted of 50 mM borate buffer (pH 8.3) and IonPhor Anion PMA Electrolyte Buffer (pH 7.7) (Dionex Corp., Sunnyvale, CA, U.S.A.) for studies utilizing direct and indirect detection methods, respectively. The effect of separation voltage on the theoretical plate numbers observed for the separations was linear for both the direct and indirect systems. Sample introduction parameters investigated included electromigration injection voltage and duration, and gravity injection duration. The conventional CZE separation using direct detection gave superior precision and better agreement with theoretical predictions than the separation using indirect detection. Both systems were evaluated for quantitative accuracy using electromigration, pressure, and gravity sample introduction modes. The conventional CZE system showed superior performance with regard to sensitivity and limits of detection. Accuracy and precision in the quantitation of known standards was greatest for both systems when the gravity sample introduction mode was used.

Anions↗

Novel, rapid optical immunoassay technique for detection of group A streptococci from pharyngeal specimens: comparison with standard culture methods.

A novel immunoassay system based on the changes in the reflection of light, termed an optical immunoassay (OIA), was utilized to directly detect group A streptococcal (GAS) carbohydrate antigen from clinical specimens. In two studies, a total of 1,275 throat swabs were tested for the presence of this antigen with the Strep A OIA rapid detection system and the results were compared with those of standard culture methods. In both studies, the Strep A OIA yielded more positive results than plating of the throat swab onto a selective agar, Trypticase soy agar containing sheep blood, or an enriched broth. In one study, the sensitivity and specificity of Strep A OIA compared with those of the broth-enriched culture were 97.4 and 95.6%, respectively. In a second study a sensitivity of 98.9% and a specificity of 98.6% were achieved. It was also shown that the carbohydrate antigen could be detected in the absence of viable GAS organisms. The Strep A OIA is an easily interpretable method and was shown to be more sensitive than routine culture methods for detecting GAS infections directly from throat swabs.

Antigens, Bacterial↗

Molecular methods in the detection and identification of mycobacterial infections.

Nucleic acid amplification (NAA) tests for direct detection of Mycobacterium tuberculosis complex in respiratory specimens have the potential to provide a more rapid diagnosis of pulmonary tuberculosis (TB) than is currently possible by conventional stain, culture, and identification tests. Currently, 2 NAA tests-enhanced Amplified Mycobacterium Tuberculosis Direct (MTD) Test (Gen-Probe, Inc) and Amplicor Mycobacterium tuberculosis Test (Roche Molecular Systems, Inc)-have been approved by the Food and Drug Administration for testing respiratory specimens that are smear positive for acid-fast bacilli (AFB). This restriction to AFB smear-positive specimens was based on data from the initial clinical trials conducted to evaluate these products that showed low sensitivity (ie, 48%-53%) and less-than-optimal specificity (ie, 96%-99%) in AFB smear-negative specimens. Data from the clinical trial for the enhanced MTD test and from 2 subsequent studies, however, suggest that this version of the MTD test is a reliable tool for rapid diagnosis of pulmonary TB, regardless of the AFB smear result. Both NAA tests have been evaluated for diagnosis of extrapulmonary TB, and results were comparable to the results of tests performed with respiratory specimens. The NAA tests also appear to be reliable for rapid identification of M tuberculosis complex in positive broth cultures of all specimen types except blood. The impact of the NAA tests on patient outcome varies based on the AFB smear result. With smear-positive results, public health and hospital infection control resources are predominantly affected. With smear-negative results, however, the potential for affecting patient outcome is much greater. In patients with smear-negative results, the NAA test can result in earlier diagnosis of TB and subsequent initiation of therapy. Use of these tests also may eliminate the need for invasive diagnostic procedures, which are costly and pose an added risk to the patient, and they may allow earlier discharge of hospitalized patients.

Bacteriological Techniques↗

Capillary electrophoretic determination of phosphate based on the formation of a Keggin-type [PMo12O40]3- complex.

Based on the formation of a Keggin-type [PMo12O40]3- complex, a sensitive capillary electrophoresis (CE) method was developed for the determination of P(V) with direct UV detection at 220 nm. A mixture of alpha- and beta-Keggin-type [PMo12O40]3- complexes was readily formed in a sample solution consisting of a trace amount of P(V), 2.5 mM Mo(VI), 0.050 M p-C6H3(CH3)-2-SO3H (XSA), and 60% v/v CH3CN. When a 0.05 M HCl and 60% v/v CH3CN solution was used as a migration electrolyte, the Keggin complexes exhibited a sharp and well-defined peak in the electropherogram. The peak area was linearly dependent on the P(V) concentration in the range of 5 x 10(-7)-5 x 10(-5) M; a detection limit of 1 x 10(-7) M was achieved. In comparison with indirect UV detection, the direct UV detection is about ten times more sensitive, because the Keggin complexes possess high molar absorptivities. The developed CE method was applied to the determination of P(V) in river water, and the results were in good agreement with those obtained by ion chromatography (IC) and colorimetry (COL) based on the formation of mixed-valence heteropoly blue species.

Acetonitriles↗

Laboratory diagnosis of infections caused by legionellae.

Legionnaires' disease can be diagnosed by detection of antibody to the organism or by direct detection of the bacterium and/or its products using immunological means, culture or a DNA probe. Culture isolation, still the most specific and sensitive test, can be done with sputum samples if proper selective techniques are used. Antibody detection is more suited for epidemiological purposes than individual cases. It has been overused to the exclusion of more specific and rapid methods, such as culture and other means of bacterial detection. Immunofluorescent microscopy remains an important tool in diagnosis, although urinary antigen detection and DNA probes are promising alternative tests. For optimal sensitivity, culture must be performed, regardless of which test is used.

Antibodies, Bacterial↗

[Detecting infectious agents in central nervous system inflammation by cerebrospinal fluid analysis].

Cerebrospinal fluid analysis is the method of choice in CNS infection and provides the basis for appropriate treatment. Due to the proximity of CSF and CNS, the infectious agent may be detected directly by microscopy or antigen or nucleic acid detection--the latter by polymerase chain reaction--in native CSF or after culture. Furthermore, intrathecal antibody synthesis against the infectious agent may identify the cause of infection. This indirect antigen detection method requires correction for a systemic antibody response and a blood-CSF barrier disturbance. The following text gives an overview of appropriate detection methods and their relevance to the most important CNS infections.

AIDS Dementia Complex↗

Prevalence of enterotoxigenic Bacteroides fragilis in hospital-acquired diarrhea.

Stool specimens from 152 hospitalized patients with diarrhea were analyzed for the presence of enterotoxigenic Bacteroides fragilis (ETBF) by a nested polymerase chain reaction (PCR) assay. ETBF gene sequences were directly detected in 14/152 (9.21%) stools of patients. The prevalence of ETBF in hospital-acquired diarrhea was statistically significant when compared to a prevalence of 2.3% in control subjects (P = 0.04). B. fragilis was cultured from 19.7% (30/152) patients with diarrhea; 4 of these isolates were enterotoxigenic. To determine whether colonization with B. fragilis is heterogeneous in nature, multiple colonies from 17 individual patients were analyzed for enterotoxin gene sequences and genotyped by arbitrarily primed PCR. Of these 17 patients, 13 harbored multiple strain types suggesting heterogeneity of colonization with both enterotoxigenic and non-enterotoxigenic strains. Identification of ETBF in the stools of 10 patients in the absence of a positive culture is likely due to the noted heterogeneity and suggests that detection of enterotoxin by PCR should be performed directly in the stool. These preliminary data indicate that ETBF may play a role in hospital-acquired diarrhea of unknown origin and suggest the need for further studies.

Bacteroides Infections↗

Comparison of two micro-analytical methods for detecting the spatial distribution of sorbed Pu on geologic materials.

Subsurface transport of groundwater contaminants is greatly influenced by chemical speciation, precipitation and sorption processes at the mineral-water interface. The retardation of contaminants is often greatest at boundaries between minerals and in fractures and pore spaces. The investigation of the spatial distribution of sorbed contaminants along these boundaries requires micro-analytical techniques. The sorption of dissolved Pu(V) on a natural zeolitic tuff from Yucca Mountain (NV, USA) was examined using microautoradiography (MAR), X-ray diffraction (XRD), electron microprobe (EM) techniques, and synchrotron-based micro-X-ray fluorescence (micro-SXRF). The tuff contained a heterogeneous distribution of zeolites and trace quantities of smectites, Fe oxides (hematite), and Mn oxides (rancieite), which are present as fracture fill and pore space materials. Micro-SXRF studies showed that Pu is mostly associated with bodies of smectite plus Mn oxides, which were typically elevated in Ce, Ga, Nb, Pb, Y, Ca, Ti, and Zn. Sorbed Pu was not associated with Fe-rich bodies, which were enriched in Cl and Rb. Results of the MAR studies were complementary to that of the micro-SXRF studies in that Pu was associated with similar elements in the tuff. Indirect detection of Pu by EM or micro-SXRF (by analyzing Ag developed on the MAR photoemulsion) was a more sensitive method for detecting lower levels of sorbed Pu than the direct detection of sorbed Pu via micro-SXRF in the absence of the photoemulsion.

Adsorption↗

Diagnostic procedures in B19 infection.

In immunologic normal hosts, both children and adults, B19 can cause acute, generally self-limiting diseases. The infection leads to a viremia that can be present, at high titre, for about one week, then the onset of a specific immune response controls the infection. B19 infection in pregnancy can be associated with non-immunologic foetal hydrops or foetal death. In immunocompromised hosts, B19 can persist over several months and sometimes years. Persistent or recurrent B19 infections can be associated with chronic clinical manifestations or with transient clinical syndromes, generally related to the recrudescence of viral replication. Since the infection has been associated with a wide variety of clinical manifestations and some clinical features of B19 infection, such as anemia, artropathy and rash, can be common to other pathogens, a laboratory diagnosis of B19 infection is required. A diagnostic protocol must consider both the type of pathology and the type of patient. In immunocompetent individuals serological and virological testing is complementary, while in immunocompromised patients viral detection is the diagnosis of choice. Viral detection methods are generally based, nowadays, on the direct detection of B19 genome in clinical specimens. B19 DNA is mainly detected by hybridizations assays and by the most sensitive PCR assays. Serological diagnosis of B19 infection is generally achieved by detection of IgM and IgG antibodies to the B19 structural proteins VP1 and VP2. IgM detection is most often performed by capture assays, both in EIA and RIA formats, IgG are mainly detected by indirect EIA and immunofluorescence tests.

Antibodies, Viral↗