Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “COSMIC RADIATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Simulation of the low-Earth-orbit dose rates using secondary radiations from the HZE particles at NIRS-HIMAC.

In order to study biological effects from cyclic dose rates encountered at the low-Earth orbit (LEO), an experimental facility was designed in the Biology room of the Heavy Ion Medical Accelerator in Chiba (NIRS-HIMAC). An incubator placed in this facility is irradiated repeatedly by secondary radiations from HZE-particle beams supplied for independent users. The daily-average dose rate (1.4 mGy d-1) measured for 223 days and short-term dose rates measured for selected beam conditions were comparable to the dose rates observed in past LEO missions. Severe solar particle events can be simulated with hourly maximum dose rate of 2.8 mGy h-1. Preliminary measurements using CR-39 and TLD indicated that the dominant LET range is less than 5 keV micrometers-1. These results demonstrate the possibility of this facility for radiobiology studies of the effects of low dose rates comparable to the LEO environment.

Cesium Radioisotopes↗

In-flight measured and predicted ambient dose equivalent and latitude differences on effective dose estimates.

The results from 2 years (2001-2002) of experimental measurements of in-board radiation doses received at IBERIA commercial flights are presented. The routes studied cover the most significant destinations and provide a good estimate of the route doses as required by the new Spanish regulations on air crew radiation protection. Details on the experimental procedures and calibration methods are given. The experimental measurements from the different instruments (Tissue Equivalent Proportional Counter and the combination of a high pressure ion chamber and a high-energy neutron compensated rem-counter) and their comparison with the predictions from some route-dose codes (CARI-6, EPCARD 3.2) are discussed. In contrast with the already published data, which are mainly focused on North latitudes over parallel 50, many of the data presented in this work have been obtained for routes from Spain to Central and South America.

Aircraft↗

Space radiation measurements on-board ISS--the DOSMAP experiment.

The experiment 'Dosimetric Mapping' conducted as part of the science program of NASA's Human Research Facility (HRF) between March and August 2001 was designed to measure integrated total absorbed doses (ionising radiation and neutrons), heavy ion fluxes and its energy, mass and linear energy transfer (LET) spectra, time-dependent count rates of charged particles and their corresponding dose rates at different locations inside the US Lab at the International Space Station. Owing to the variety of particles and energies, a dosimetry package consisting of thermoluminescence dosemeter (TLD) chips and nuclear track detectors with and without converters (NTDPs), a silicon dosimetry telescope (DOSTEL), four mobile silicon detector units (MDUs) and a TLD reader unit (PILLE) with 12 TLD bulbs as dosemeters was used. Dose rates of the ionising part of the radiation field measured with TLD bulbs applying the PILLE readout system at different locations varied between 153 and 231 microGy d(-1). The dose rate received by the active devices fits excellent to the TLD measurements and is significantly lower compared with measurements for the Shuttle (STS) to MIR missions. The comparison of the absorbed doses from passive and active devices showed an agreement within +/- 10%. The DOSTEL measurements in the HRF location yielded a mean dose equivalent rate of 535 microSv d(-1). DOSTEL measurements were also obtained during the Solar Particle Event on 15 April 2001.

Aerospace Medicine↗

Immunofluorescence detection of clustered gamma-H2AX foci induced by HZE-particle radiation.

We studied the spatial and temporal distributions of foci of the phosphorylated form of the histone protein H2AX (gamma-H2AX), which is known to be activated by double-strand breaks after irradiation of human fibroblast cells with high-energy silicon (54 keV/microm) and iron (176 keV/microm) ions. Here we present data obtained with the ion path parallel to a monolayer of human fibroblast cells that leads to gamma-H2AX aggregates in the shape of streaks stretching over several micrometers in an x/y plane, thus enabling the analysis of the fluorescence distributions along the ion trajectories. Qualitative analyses of these distributions provide insights into DNA damage processing kinetics for high charge and energy (HZE) ions, including evidence of increased clustering of DNA damage and slower processing with increasing LET.

Cells, Cultured↗

Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir.

A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. Moscow. Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three different locations on board the Mir space station. Thermoluminescence dosemeters (TLDs) were exposed at various depths inside the phantom either parallel or perpendicular to the hull of the spacecraft. The high-temperature ratio (HTR) method was used for the evaluation of the TLDs. The method was developed at the Atominstitute of the Austrian Universities. Vienna, Austria, and has already been used for measurements in mixed radiation fields on earth and in space with great success. It uses the changes of peak height ratios in LiF:Mg,Ti glow curves in dependence on the linear energy transfer (LET), and therefore allows determination of an 'averaged' LET as well as measurement of the absorbed dose. A mean quality factor and, subsequently, the dose equivalent can be calculated according to the Q(LETinfinity) relationship proposed by the ICRP. The small size of the LiF dosemeters means that the HTR method can be used to determine the gradient of absorbed dose and dose equivalent inside the tissue equivalent body.

Aerospace Medicine↗

The measured radiation environment within Spacelabs 1 and 2 and comparison with predictions.

To measure the radiation environment in the Spacelab (SL) module and on the pallet, a set of passive and active radiation detectors was flown as part of the Verification Flight Instrumentation (VFI). SL 1 carried 4 passive and 2 active detector packages which, with the data from the 26 passive detectors of Experiment INS006, provided a comprehensive survey of the radiation environment within the spacecraft. SL 2 carried 2 passive VFI units on the pallet. Thermoluminescent dosimeters (TLDs) measured the low linear energy transfer (LET) dose component; the HZE fluence and LET spectra were mapped with CR-39 track detectors; thermal and epithermal neutrons were measured with the use of fission foils; metal samples analyzed by gamma ray spectroscopy measured low levels of several activation lines. The TLDs registered from 97 to 143 mrad in the SL 1 module. Dose equivalents of 330 +/- 70 mrem in the SL 1 module and 537 +/- 37 mrem on the SL 2 pallet were measured. The active units in the SL 1 module each contained an integrating tissue-equivalent ion chamber and two differently-shielded xenon-filled proportional counters. The ion chambers accumulated 125 and 128 mrads for the mission with 17 and 12 mrads accumulated during passages through the South Atlantic Anomaly (SAA). The proportional counter rates (approximately 1 cps at sea level) were approximately 100 cps in the middle of the SAA (mostly protons), approximately 35 cps at large geomagnetic latitudes (cosmic rays) and approximately 100 cps in the South Horn of the electron belts (mostly bremsstrahlung). Detailed results of the measurements and comparison with calculated values are described.

Atlantic Ocean↗

Estimates of HZE particle contributions to SPE radiation exposures on interplanetary missions.

Estimates of radiation doses resulting from possible HZE (high energy heavy ion) components of solar particle events (SPEs) are presented for crews of manned interplanetary missions. The calculations assume a model spectrum obtained by folding measured solar flare HZE particle abundances with the measured energy spectra of SPE alpha particles. These hypothetical spectra are then transported through aluminum spacecraft shielding. The results, presented as estimates of absorbed dose and dose equivalent, indicate that HZE components by themselves are not a major concern for crew protection but should be included in any overall risk assessment. The predictions are found to be sensitive to the assumed spectral hardness parameters.

Alpha Particles↗

An analysis of particle track effects on solid mammalian tissues.

Relative biological effectiveness (RBE) and quality factor (Q) at extreme values of linear energy transfer (LET) have been determined on the basis of experiments with single-cell systems and specific tissue responses. In typical single-cell systems, each heavy particle (Ar or Fe) passes through a single cell or no cell. In experiments on animal tissues, however, each heavy particle passes through several cells, and the LET can exceed 200 keV micrometers-1 in every cell. In most laboratory animal tissue systems, however, only a small portion of the hit cells are capable of expressing the end-point being measured, such as cell killing, mutation or carcinogenesis. The following question was therefore addressed: do RBEs and Q factors derived from single-cell experiments properly account for the damage at high LET when multiple cells are hit by HZE tracks? A review is offered in which measured radiation effects and known tissue properties are combined to estimate on the one hand, the number of cells at risk, p3n, per track, where n is the number of cells per track based on tissue and organ geometry, and p3 is the probability that a cell in the track is capable of expressing the experimental end-point. On the other hand, the tissue and single-cell responses are compared by determining the ratio RBE in tissue/RBE in corresponding single cells. Experimental data from the literature indicate that tissue RBEs at very high LET (Fe and Ar ions) are higher than corresponding single-cell RBEs, especially in tissues in which p3n is high.

Animals↗

Fluence-based and microdosimetric event-based methods for radiation protection in space.

The National Council on Radiation Protection and Measurements (NCRP) has recently published a report (Report #137) that discusses various aspects of the concepts used in radiation protection and the difficulties in measuring the radiation environment in spacecraft for the estimation of radiation risk to space travelers. Two novel dosimetric methodologies, fluence-based and microdosimetric event-based methods, are discussed and evaluated, along with the more conventional quality factor/LET method. It was concluded that for the present, any reason to switch to a new methodology is not compelling. It is suggested that because of certain drawbacks in the presently-used conventional method, these alternative methodologies should be kept in mind. As new data become available and dosimetric techniques become more refined, the question should be revisited and that in the future, significant improvement might be realized. In addition, such concepts as equivalent dose and organ dose equivalent are discussed and various problems regarding the measurement/estimation of these quantities are presented.

Cosmic Radiation↗

The use of TEPC for reference dosimetry.

The radiation fields on board aircraft are quite complex and cover an energy range that is unusual in ordinary radiation protection work. Usually dosemeters measure only one radiation quality and the mixture found on board makes measurements complicated. There is also some doubt when it comes to the best choice of quantity for this application and no radiation standards exist for this kind of radiation field. For those reasons there is a need to find a standard measurement procedure that could serve as a reference for other, maybe simpler, measurements or for calculations of route doses. The only direct reading dosemeter that both measures the absorbed dose to tissue and the radiation quality (in terms of lineal energy) is the tissue-equivalent proportional counter (TEPC). The instrument was originally developed for scientific purposes and is still used as such. The detector consists of a gas filled cavity surrounded by a few mm thick wall. Both wall and gas consists of tissue-like material. The measurement principles are explained. Results observed with TEPC instruments are demonstrated. A preliminary collection of data reported by different groups from measurements on board aircraft will be shown. The results agree within +/- 20%. The conclusion is that TEPC instruments have the capacity of serving as reference instruments.

Aerospace Medicine↗

Analysis of radiation risk from alpha particle component of solar particle events.

The solar particle events (SPE) will contain a primary alpha particle component, representing a possible increase in the potential risk to astronauts during an SPE over the often studied proton component. We discuss the physical interactions of alpha particles important in describing the transport of these particles through spacecraft and body shielding. Models of light ion reactions are presented and their effects on energy and linear energy transfer (LET) spectra in shielding discussed. We present predictions of particle spectra, dose, and dose equivalent in organs of interest for SPE spectra typical of those occurring in recent solar cycles. The large events of solar cycle 19 are found to have substantial increase in biological risk from alpha particles, including a large increase in secondary neutron production from alpha particle breakup.

Alpha Particles↗

Stochastics of HZE-induced microlesions.

Fundamental biological experiments with bacteria, yeast, and mammalian cells irradiated with ions heavier than helium indicate that maximal probability of single-hit inactivation does not occur when the ion has LET below about 100-200 keV/micrometer. Theoretical treatments of cell inactivation data and the radiation chemistry in particle tracks are consistent with this finding. If a "microlesion" is defined as a linear array, within a tissue, of cells inactivated with maximum probability, surrounded by non-lethally damaged cells, then, by this definition, there must be an LET below which "microlesion" damage cannot be expected. In a retrospective survey of experimental literature in which single-particle effects in tissues were sought, it was found that little or no evidence has been reported supporting single-particle effects in tissues when LET was below 200 keV/micrometer, while some experimenters who irradiated tissues with particles having LET greater than 200 keV/micrometer reported effects that could be attributed to single-particle tracks.

Animals↗

Results of biological experiments carried out under conditions of "Vostok" flights with the participation of cosmonauts A.G. Nikolajev, P.R. Popovich and V.F. Bykovsky.

The data are presented on a study of the effect of space flight factors, particularly of weightlessness and radiation, on the fertilization, growth and development of Drosophila melanogaster and on the mechanism of heredity in Tradescantia paludosa. Copulation, oviposition and development of Drosophila are shown to be possible under 4-day weightless conditions. A distortion in the sex ratio has been registered in the cultures of flies grown in flight. Three types of changes in Tradescantia microspores brought about by flight factors have been revealed, i.e. chromosome rearrangements, distortions in the mitotic mechanism and stimulation of growth processes in the cell. It is suggested that rearrangements of chromosomes are caused by the action of vibrations and accelerations while distortions in the mechanism of mitosis are mainly related to the weightlessness effect.

Animals↗

Worms in space? A model biological dosimeter.

Although it is well known that radiation causes mutational damage, little is known about the biological effects of long-term exposure to radiation in space. Exposure to radiation can result in serious heritable defects in experimental animals, and in humans, susceptibility to cancer, radiation-sickness, and death at high dosages. It is possible to do ground controlled studies of different types of radiation on experimental animals and to physically measure radiation on the space station or on space probes. However, the actual biological affects of long-term exposure to the full range of space radiation have not been studied, and little information is available about the biological consequences of solar flares. Biological systems are not simply passive recording instruments. They respond differently under different conditions, and thus it is important to be able to collect data from a living animal. There are technical difficulties that restrict the placement of an experimental organism in a space environment for long periods of time, in a manner that allows for the recovery of genetic data. Use of the self-fertilizing hermaphroditic nematode, Caenorhabditis elegans offers potential for the design of a biological dosimeter. In this paper, we describe the advantages of this model system and review the literature of C. elegans in space.

Animals↗

NASA Space Radiation Transport Code Development Consortium.

Recently, NASA established a consortium involving the University of Tennessee (lead institution), the University of Houston, Roanoke College and various government and national laboratories, to accelerate the development of a standard set of radiation transport computer codes for NASA human exploration applications. This effort involves further improvements of the Monte Carlo codes HETC and FLUKA and the deterministic code HZETRN, including developing nuclear reaction databases necessary to extend the Monte Carlo codes to carry out heavy ion transport, and extending HZETRN to three dimensions. The improved codes will be validated by comparing predictions with measured laboratory transport data, provided by an experimental measurements consortium, and measurements in the upper atmosphere on the balloon-borne Deep Space Test Bed (DSTB). In this paper, we present an overview of the consortium members and the current status and future plans of consortium efforts to meet the research goals and objectives of this extensive undertaking.

Algorithms↗

Implementation of ALARA radiation protection on the ISS through polyethylene shielding augmentation of the Service Module Crew Quarters.

With 5-7 month long duration missions at 51.6 degrees inclination in Low Earth Orbit, the ionizing radiation levels to which International Space Station (ISS) crewmembers are exposed will be the highest planned occupational exposures in the world. Even with the expectation that regulatory dose limits will not be exceeded during a single tour of duty aboard the ISS, the "as low as reasonably achievable" (ALARA) precept requires that radiological risks be minimized when possible through a dose optimization process. Judicious placement of efficient shielding materials in locations where crewmembers sleep, rest, or work is an important means for implementing ALARA for spaceflight. Polyethylene (CnHn) is a relatively inexpensive, stable, and, with a low atomic number, an effective shielding material that has been certified for use aboard the ISS. Several designs for placement of slabs or walls of polyethylene have been evaluated for radiation exposure reduction in the Crew Quarters (CQ) of the Zvezda (Star) Service Module. Optimization of shield designs relies on accurate characterization of the expected primary and secondary particle environment and modeling of the predicted radiobiological responses of critical organs and tissues. Results of the studies shown herein indicate that 20% or more reduction in equivalent dose to the CQ occupant is achievable. These results suggest that shielding design and risk analysis are necessary measures for reducing long-term radiological risks to ISS inhabitants and for meeting legal ALARA requirements. Verification of shield concepts requires results from specific designs to be compared with onboard dosimetry.

Astronauts↗

Particle directionality and trapped proton fluences on LDEF.

Directionality of incident space radiation is a significant factor in spacecraft shielding and astronaut dosimetry in low Earth orbit (LEO). Particle directionality of GCR and trapped protons were measured on LDEF with plastic nuclear track detectors (PNTD) from the P0006 west-side experiment. This experiment consisted of a thick detector stack and is described more fully in a companion article (Benton et al., 1996). The anisotropy of the trapped protons produced maximum intensity for protons arriving from the west. The fluences of the eastward directed trapped protons have been measured by selection of the particles on the basis of range in the PNTDs. The measured fluences are compared with the model calculations of Armstrong and Colborn (1993).

Anisotropy↗

Unique biological aspects of radiation hazards--an overview.

Low orbit, geostationary, and deep-space flights differ from one another with respect to particle radiation environment, participating population size, mission duration, and biological risks other than radiation. It is proposed that all of these factors be considered in the setting of safety standards and, in particular, that the rem-dose concept is applicable only to radiations having low and intermediate linear energy transfer (electrons, protons, and helium ions), whereas the incidence of microlesions is a more meaningful indicator of the hazard due to higher-Z, high energy (HZE) particles. A microlesion is the biological injury inflicted in a specific tissue by a single HZE particle, and it is still in need of quantitative biological definition for specific mammalian tissues. If for example, a microlesion is taken as due to a HZE particle track 10 cell diameters long with LET > 200 KeV/micrometer in its core and > 25 rad dose in its penumbra at a distance of 10 micrometers, then the microlesion dose rate in geostationary orbit, for example, is about 9,000 microlesions per cm3 of tissue per month.

Aerospace Medicine↗