Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Advanced high-performance liquid chromatography method development. Discovering unexpected choices in chromatography.

The influence of some important experimental parameters on the resolution of compounds as well as the validity of widely used rules of thumb and of common expectations about how to improve resolution is discussed. It will be shown, on the basis of selected examples, that the general expectations about how the experimental parameters have to be adjusted for better resolution does not cover all chances for resolution improvement. The tool for understanding the method and to discover all chances for increasing selectivity is the resolution map of a method.

Algorithms↗

Comparison between liquid chromatography-UV detection and liquid chromatography-mass spectrometry for the characterization of impurities and/or degradants present in trimethoprim tablets.

The characterization of impurities and/or degradants present in pharmaceutical compounds is an important part of the drug development process. Although LC-UV is commonly employed for impurities and degradant compound determination, LC-MS techniques are proposed in this work to be a viable modem alternative for the characterization of these compounds. LC-UV and LC-MS were compared for the detection of impurities present in different brands of trimethoprim tablets by using an in-line LC-UV-MS system with atmospheric pressure chemical ionization source (APCI) coupled with a reversed-phase gradient HPLC system. It was shown that, although chemical noise was higher when using full-scan LC-MS compared to LC-UV, low level impurities were better detected by mass spectrometry (MS) when modern software algorithms are employed. These included the "Contour" chromatogram algorithm and/or the "component detection algorithm" (CODA). In addition, MS allowed for the simultaneous determination of the molecular masses and some structural information of the impurities and/or degradants. The results also showed a large difference in the purity of trimethoprim among different manufacturers. LC-MS and tandem MS techniques were employed to acquire fragmentation patterns for trimethoprim and its degradants to gain insight into their structures.

Chromatography, High Pressure Liquid↗

Identification of aroma active compounds in orange essence oil using gas chromatography-olfactometry and gas chromatography-mass spectrometry.

Using GC-MS and GC-flame ionization detection (FID)/olfactometry, 95 volatile components were detected in orange essence oil, of which 55 were aroma active. In terms of FID peak area the most abundant compounds were: limonene, 94.5%; myrcene, 1%; valencene, 0.8%; linalool, 0.7%, and octanal, decanal, and ethyl butyrate, 0.3% each. One hundred percent of the aroma activity was generated by slightly more than 4% of the total volatiles. The most intense aromas were produced by octanal, wine lactone, linalool, decanal, beta-ionone, citronellal, and beta-sinensal. Potent aroma components reported for the first time in orange essence oil include: E-2-octenal, 1-octen-3-ol, Z-4-decenal, E,E-2,4-nonadienal, guaiacol, gamma-octalactone, and m-cresol. Over 20 compounds were identified for the first time in orange essence oil using MS, however, most did not exhibit aroma activity.

Citrus↗

Liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry of the Alternaria mycotoxins alternariol and alternariol monomethyl ether in fruit juices and beverages.

Alternariol (AOH) and alternariol monomethyl ether (AME) are among the main mycotoxins formed in apples and other fruits infected by Alternaria alternata. For determination of AOH and AME by LC, apple juice and other fruit beverages were cleaned up on C18 and aminopropyl solid-phase extraction columns. Positive and negative ion mass spectra of AOH and AME under electrospray (ESI) and atmospheric pressure chemical ionization (APCI) conditions were obtained. Collision-induced dissociation of the [M+H]+ and [M-H]- ions for both compounds were also studied. The phenolic anions of both compounds are more stable with less fragmentation. In quantitative analysis, negative ion detection also offers lower background and better sensitivity. Sensitive LC-MS and LC-MS-MS confirmatory procedures based on APCI with negative ion detection were applied to confirm the natural occurrence of AOH in nine samples of apple juice and in single samples of some other clear fruit beverages--grape juice, cranberry nectar, raspberry juice, red wine, and prune nectar (which also contained 1.4 ng AME/ml)--at levels of up to 6 ng AOH/ml. Electrospray LC-MS-MS with negative ion detection and in multiple reaction monitoring mode offers higher sensitivity and specificity. Absolute detection was better than 4 pg per injection for both compounds.

Beverages↗

Complete structure elucidation of a globular protein by particle beam liquid chromatography-Fourier transform infrared spectrometry and electrospray liquid chromatography-mass spectrometry. Sequence and conformation of beta-lactoglobulin.

The advantages to the use of both mass spectrometry (MS) and Fourier transform infrared spectrometry (FT-IR) in combination for the structural characterization of the tryptic digest of a model globular protein is demonstrated. HPLC has been interfaced to both spectroscopic techniques and has provided a high degree of structural detail for the target protein. beta-Lactoglobulins A and B were digested with trypsin and chromatographed with narrow-bore, reversed-phase HPLC. As determined by LC-FT-IR spectrometry, the conformation of each form of intact beta-lactoglobulin was randomized upon elution. The particle beam and the electrospray LC-MS interfaces enabled the acquisition of spectra for nanogram injection quantities. The primary structures were determined from the accurate molecular mass determinations of the digest fragments. Infrared spectra confirmed the presence of some amino acid functionalities.

Amino Acid Sequence↗

Determination of sulfonylurea degradation products in soil by liquid chromatography-ultraviolet detection followed by confirmatory liquid chromatography-tandem mass spectrometry.

A method based on liquid extraction followed by sample enrichment on reversed-phase solid-phase extraction was developed for the extraction of five degradation products of four sulfonylurea herbicides (chlorsulfuron, metsulfuron-methyl, thifensulfuron-methyl and tribenuron-methyl) from soil. The compounds have been quantified by LC-UV and identified by tandem LC-MS with electrospray ionization or atmospheric pressure chemical ionization. The limits of detection for the five compounds were between 10 and 50 micrograms kg-1. The method has been applied to the extraction of soil samples after microbial degradation of sulfonylurea herbicides.

Chromatography, Liquid↗

Comparison of gas chromatography-pulsed flame photometric detection-mass spectrometry, automated mass spectral deconvolution and identification system and gas chromatography-tandem mass spectrometry as tools for trace level detection and identification.

The complexity of a matrix is in many cases the major limiting factor in the detection and identification of trace level analytes. In this work, the ability to detect and identify trace level of pesticides in complex matrices was studied and compared in three, relatively new methods: (a) GC-PFPD-MS where simultaneous PFPD (pulsed flame photometric detection) and MS analysis is performed. The PFPD indicates the exact chromatographic time of suspected peaks for their MS identification and provides elemental information; (b) automatic GC-MS data analysis using the AMDIS ("Automated Mass Spectral Deconvolution and Identification System") software by the National Institute of Standards and Technology; (c) GC-MS-MS analysis. A pesticide mixture (MX-5), containing diazinon, methyl parathion, ethyl parathion, methyl trithion and ethion was spiked, in descending levels from 1 ppm to 10 ppb, into soil and sage (spice) extracts and the detection level and identification quality were evaluated in each experiment. PFPD-MS and AMDIS exhibited similar performance, both superior to standard GC-MS, revealing and identifying compounds that did not exhibit an observable GC peak (either buried under the chromatographic background baseline or co-eluting with other interfering GC peaks). GC-MS-MS featured improved detection limits (lower by a factor of 6-8) compared to AMDIS and PFPD-MS. The GC-PFPD-MS-MS combination was found useful in several cases, where no reconstructed ion chromatogram MS-MS peaks existed, but an MS-MS spectrum could still be extracted at the elution time indicated by PFPD. The level of identification and confirmation with MS-MS was inferior to that of the other two techniques. In comparison with the soil matrix, detection limits obtained with the loaded sage matrix were poorer by similar factors for all the techniques studied (factors of 5.8, >6.5 and 4.0 for AMDIS, PFPD-MS and MS-MS, respectively). Based on the above results, the paper discusses the trade-offs between detectivity and identification level with the compared three techniques as well as other more traditional techniques and approaches.

Automation↗

Analysis of steroids in environmental water samples using solid-phase extraction and ion-trap gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry.

This paper describes an improved method for the extraction and determination of three steroids, oestrone, 17beta-oestradiol, and the synthetic contraceptive steroid 17alpha-ethinyloestradiol in aqueous matrices. Samples of wastewater and environmental water were spiked with internal standards, comprising isotopically labelled analogues of the steroids to be determined. The samples were extracted using solid-phase extraction disks and the extracts were then derivatized to form tert.-butyldimethylsilyl derivatives. The derivatised steroids were determined in the final extracts by GC-MS or GC-MS-MS allowing an operational detection limit for each steroid in effluent samples of 1 ng l(-1).

Chromatography, Gas↗

High-performance liquid chromatography of amino acids, peptides and proteins. CXXVIII. Effect of D-amino acid substitutions on the reversed-phase high-performance liquid chromatography retention behaviour of neuropeptide Y[18-36] analogues.

The reversed-phase high-performance liquid chromatographic (RP-HPLC) gradient elution behaviour of a series of peptides related to Neuropeptide Y (NPY) has been investigated. The peptides studied included NPY, NPY[13-36], NPY[18-36] and a series of 16 analogues of NPY[18-36], each with a single D-amino acid substitution. Chromatographic parameters which relate to the interactive contact area and the binding affinity have been evaluated with two different stationary phase ligands and two organic modifiers. The results demonstrate that D-amino acid substitutions in the sequence region encompassing amino acid residues NPY[27-31] of these NPY[18-36] peptides significantly influence the interactive behaviour of these peptides relative to the unsubstituted NPY[18-36] molecule, while substitutions in the N- and C-terminal regions had little effect. Further, these results indicate that, in hydrophobic environments, NPY[18-36] adopts a significant degree of secondary structure which is severely disrupted by the presence of the D-amino acids in the central portion of the molecule.

Acetonitriles↗

Identification and quantification of metabolites of 2,3,5,6-tetrafluoro-4-trifluoromethylaniline in rat urine using 19F nuclear magnetic resonance spectroscopy, high-performance liquid chromatography-nuclear magnetic resonance spectroscopy and high-performance liquid chromatography-mass spectrometry.

The urinary excretion profile and identity of the metabolites of 2,3,5,6-tetrafluoro-4-triflouromethylaniline, following i.p. administration to the rat at 50 mg kg(-1), were determined using a combination of 19F-NMR, HPLC-NMR and HPLC-MS. A total of 38% of the dose was eliminated in the urine as five metabolites. The major routes of metabolism were N-glucuronidation, sulfation and oxidation with a significant amount of metabolic defluorination to give a number of ortho-ring hydroxylated metabolites. The oxidised metabolites were excreted as glucuronide and/or sulfate conjugates.

Aniline Compounds↗

Detection of digoxin, digitoxin, their cardioactive metabolites and derivatives by high-performance liquid chromatography and high-performance liquid chromatography-radioimmunoassay.

High-performance liquid chromatographic (HPLC) systems are described for the separation of the cardioactive metabolites of the digoxin and digitoxin series that are formed by the splitting of digitoxose sugar residues from the aglycone steroid: isocratic separation of digoxin and its cardioactive metabolites; isocratic separation of digitoxin and its cardioactive metabolites; and gradient elution separation of the digoxin and digitoxin series including beta-acetyl- and beta-methyldigoxin. Separations were performed on a 10-microns bonded octadecyl phase column using various mixtures of acetonitrile--water and acetonitrile--methanol--water as the mobile phase. These methods provide high peak resolution and are well suited for collecting elution fractions, e.g. to link up with sensitive immunological measurements. An HPLC-radioimmunoassay method is described for the quantitation of digoxin, digitoxin and their metabolites in human tissues.

Chromatography, High Pressure Liquid↗

Comparison between liquid chromatography-time of-flight mass spectrometry and selected reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of idoxifene in human plasma.

This study compares HPLC electrospray time-of-flight mass spectrometry and selected reaction monitoring (SRM) LC-MS for high throughput quantitative determination of a small molecule drug in biological samples. A high throughput LC-MS method was developed for quantitatative determination of idoxifene in human plasma and the evaluation was accomplished with the cross-validation of the developed LC-MS method between the time-of-flight mass spectrometer, and a triple quadrupole mass spectrometer operated in the SRM mode. A simple one-step semi-automated 96-well liquid-liquid extraction procedure was used to prepare 96 samples in approximately 30 min and a rapid gradient was used to shorten the LC run time. Time-of-flight mass spectrometry provides acquisition of full-scan mass spectra and extracted ion current chromatograms, which may be extracted from the total ion current chromatogram for peak area determination. The limit of quantitation for idoxifene in human plasma obtained with the time-of-flight mass spectrometer was 5 ng/ml based on 100-microl aliquots of human plasma, and the linear dynamic range was from 5 ng/ml to 2000 ng/ml. The quantitative LC-MS results from the time-of-flight mass spectrometer demonstrated that precision did not exceed 7.1% and accuracy did not exceed 1.7% with reference to quality control samples at three concentration levels in replicates of six. In contrast, the limit of quantitation for idoxifene in human plasma using a tandem triple quadrupole mass spectrometer was 0.5 ng/ml with a linear dynamic range to 1000 ng/ml. The results from the triple quadrupole instrument show that the precision did not exceed 2.2% and accuracy did not exceed 2.9%. The overall results suggest time-of-flight mass spectrometry may be a viable technique for high throughput bioanalytical work for the quantitative determination of a representative small molecule drug in the low ng/ml range in human plasma.

Calibration↗

Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) in toxicological analysis. Studies on the detection of clobenzorex and its metabolites within a systematic toxicological analysis procedure by GC-MS and by immunoassay and studies on the detection of alpha- and beta-amanitin in urine by atmospheric pressure ionization electrospray LC-MS.

GC-MS is the method of choice for toxicological analysis of toxicants volatile in GC while non-volatile and/or thermally labile toxicants need LC-MS for their determination. Studies are presented on the toxicological detection of the amphetamine-like anorectic clobenzorex in urine by GC-MS after acid hydrolysis, extraction and acetylation and by fluorescence polarization immunoassay (FPIA, TDx (meth)amphetamine II). After ingestion of 60 mg of clobenzorex, the parent compound and/or its metabolites could be detected by GC-MS for up to 84 h or by FPIA for up to 60 h. Since clobenzorex shows no cross-reactivity with the used immunoassay, the N-dealkylated metabolite amphetamine is responsible for the positive TDx results. The intake of clobenzorex instead of amphetamine can be differentiated by GC-MS detection of hydroxyclobenzorex which is detectable for at least as long as amphetamine. In addition, the described GC-MS procedure allows the simultaneous detection of most of the toxicologically relevant drugs. Furthermore, studies are described on the atmospheric pressure ionization electrospray LC-MS detection of alpha- and beta-amanitin, toxic peptides of amanita mushrooms, in urine after solid-phase extraction on RP-18 columns. Using the single ion monitoring mode with the ions m/z 919 and 920 the amanitins could be detected down to 10 ng/ml of urine which allows us to diagnose intoxications with amanita mushrooms.

Amanitins↗