Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Characteristics of lipopolysaccharides of Salmonella typhi isolated from carriers and patients suffering from typhoid fever.

Lipopolysaccharides (LPS) of Salmonella typhi strains, isolated from carriers and patients suffering from typhoid fever, were characterised according to their biochemical properties, morphological structure and degree of aggregation of complexes. All preparations of LPS, regardless of their origin, were morphologically heterogeneous. Free electrophoresis and immunoelectrophoresis demonstrated that LPS preparations were composed of components possessing different mobilities in electric fields. LPS of bacterial strains isolated from both carriers and patients, split upon reaction in immunoelectrophoresis with specific antiserum 73, rabbit antiserum to Salmonella typhi Vi Bhatnagar and 0-901 split into anodic and cathodic fractions. The anodic fraction reacted similarly as Vi antigen. LPS from Salmonella typhi Ty-2 yielded only the cathodic fraction, typical for O antigen. LPS from strains which were passaged twice in nutritional medium possessed identical properties as LPS from fresh cultures of Salmonella typhi. Electron microscopy revealed that LPS appears as long bands, rods, ellipsoid forms and amorphous material. Contrary to amorphous material, the bands, rods and ellipsoid forms possessed three-layer structure.

Antigens, Bacterial↗

Electrochemical behavior and differential pulse polarographic determination of rifampicin in the pharmaceutical preparations.

Differential pulse polarographic (DPP) analytical procedure for the rifampicin antibiotic, which can be applied to monitor its synthetic process from the starting antibiotic of rifamycin B or rifamycin SV, has been developed based on the electrochemical reduction of an azomethine group. Rifampicin exhibited a cathodic peak due to the azomethine group in the side chain of 3-[(4-methyl-1-piperazinyl)imino]methyl moiety and another cathodic peak due to the carbonyl group in rifamycin SV by DPP The experimental peak potential shift of an azomethine reduction was -73 mV/pH in the pH range between 3.0 and 7.5, agreeing with involvement of 4 e- and 5 H+ in its reduction. By the cyclic voltammetric(CV) studies, the azomethine and the carbonyl reductions in rifampicin were processed irreversibly on the mercury electrode. The plot of peak currents vs. concentrations of rifampicin ranging 1.0 x 10(-7) M tp approximately 1.0 x 10(-5) M yielded a straight line with a correlation coefficient of 0.9996. The detection limit was 1.0 x 10(-8) M with a modulation amplitude of 50 mV. DPP has been successfully applied for the determination of rifampicin in the pharmaceutical preparations.

Antibiotics, Antitubercular↗

Molecular basis for the properties of the thyroxine-binding globulin-slow variant in American blacks.

Thyroxine-binding globulin-slow (TBG-S), a variant found in 4-12% of Black and Pacific Island populations, is inherited as an X-chromosome linked trait. This variant is detected on isoelectric focusing by the characteristic cathodal shift of all its isoforms, suggesting that the difference resides in the core protein. In addition, TBG-S is slightly more thermolabile, which explains why subjects expressing TBG-S have on the average lower serum TBG, and thus reduced T4, concentrations. We now report the molecular basis for this TBG variant, deduced from sequencing the TBG-S gene of an American Black man. Sequencing of the four coding regions and all intron/exon junctions revealed a single nucleotide substitution in the codon for amino acid 171 of the mature protein. The resulting change of the codon GAC to AAC results in replacement of the normal aspartic acid by asparagine. Since the negative charge provided by the aspartic acid is lost when replaced by the neutral asparagine, this substitution seems responsible for the cathodal shift on isoelectric focusing and slower electrophoretic mobility of TBG-S. An identical nucleotide substitution was identified in an unrelated American Black man expressing TBG-S. Whether the TBG-S phenotype observed in populations from the Pacific Islands is caused by the same mutation remains to be determined.

Amino Acid Sequence↗

Organic dyestuffs as catalysts for fuel cells.

Electrocatalysis in fuel cells requires as well substances capable of catalyzing the anodic oxidation of fuels as catalysts for the cathodic reduction of oxygen. Several dyestuffs that catalyze oxygen reduction are known, but up to now only one has been described as active in anodic reactions. All these dyestuffs are N4-chelates. Comparative studies have shown that chelates with other types of coordination, in particular N202-, 04-, N2S2- and S4-chelates, are able to catalyze the reduction of oxygen, though they are considerably less active than the N4-compounds. With a given type of coordination, the nature of the central atom has a decisive influence on the catalytic activity of the dyestuff, whereas substitution on the organic skeleton has only a slight effect. Thermal pretreatment of the N4-chelates can considerably increase their stability in electrolytes containing sulfuric acid. All the experimental results point to the conclusion that, with electrocatalysts, as with natural oxygen carriers, the interaction essential for catalysis takes place between the oxygen and the central metal ion. Various assumptions may be made as to the nature of the rate-determining step. The cathodic reduction of oxygen can be regarded as redox catalysis, or it can be considered from the standpoint of molecular orbital theory. The models hitherto suggested for the mechanism of oxygen reduction are tested against the experimental results and a modified model based on MO theory is put forward.

Catalase↗

Separation of organoselenium compounds and their electrochemical detection.

A simplified procedure based on ion-exchange separation of selenourea (Se-U) and selenocystamine (Se-CM), which have very close half-wave potential when they are simultaneously analyzed by voltammetric techniques, has been developed and optimized. Thus, selenocystamine remains in the cation exchanger Purolite C 100 H, whereas selenourea is found in the effluent and is determined by square wave cathodic stripping voltammetry using Na(2)CO(3 )as electrolyte. Selenocystamine is then eluted from the cation exchanger using 4 M HCl and analyzed by square wave cathodic stripping voltammetry in the HCl solution. For each voltammetric determination the corresponding parameters were investigated and optimized; the obtained detection limits were 0.3 ng Se mL(-1) for Se-CM and 2 ng Se mL(-1) for Se-U. A flow sheet for the separation of inorganic (Se(IV) and Se(VI)) and organoselenium compounds (Se-U, Se-CM, (CH(3))(2)Se(2), and (CH(3))(2)Se) developed for their electrochemical detection is presented and it was successfully applied to a certified reference material, an environmental soil sample, and a urine sample.

Adult↗

Electrochemical vapor generation of selenium species after online photolysis and reduction by UV-irradiation under nano TiO2 photocatalysis and its application to selenium speciation by HPLC coupled with atomic fluorescence spectrometry.

An online UV photolysis and UV/TiO2 photocatalysis reduction device (UV-UV/TiO2 PCRD) and an electrochemical vapor generation (ECVG) cell have been used for the first time as an interface between high-performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS) for selenium speciation. The newly designed ECVG cell of approximately 115 microL dead volume consists of a carbon fiber cathode and a platinum loop anode; the atomic hydrogen generated on the cathode was used to reduce selenium to vapor species for AFS determination. The noise was greatly reduced compared with that obtained by use of the UV-UV/TiO2 PCRD-KBH4-acid interface. The detection limits obtained for seleno-DL: -cystine (SeCys), selenite (Se(IV)), seleno-DL: -methionine (SeMet), and selenate (Se(VI)) were 2.1, 2.9, 4.3, and 3.5 ng mL(-1), respectively. The proposed method was successfully applied to the speciation of selenium in water-soluble extracts of garlic shoots cultured with different selenium species. The results obtained suggested that UV-UV/TiO2 PCRD-ECVG should be an effective interface between HPLC and AFS for the speciation of elements amenable to vapor generation, and is superior to methods involving KBH4.

Catalysis↗

Electrochemical properties of silver-copper alloy microelectrodes for use in voltammetric field apparatus.

Microelectrodes of silver-copper alloys have been evaluated for use in voltammetric analyses. Increased overpotential towards the hydrogen overvoltage reaction (HER) was found as a function of increased copper content in the silver. A study of oxidizing products by cyclic voltammetry (CV) in NaOH solution showed ten anodic and eight cathodic peaks which are described in the present paper. The behaviour of these alloy electrodes is somewhere between pure silver and pure copper electrodes. Differential pulse anodic stripping voltammetry (DPASV) was used to measure zinc, cadmium and lead in ultrapure water only (18 MOmegacm), and good linearity was found for all metals (r (2)=0.998) in the range of 0.5 to 5 ppb with a 600- to 1,200-s plating time. It was additionally found that cadmium and lead were better separated on the alloy electrodes compared to pure silver electrodes. Measurements of nickel were carried out on alloy electrodes by use of adsorptive differential pulse cathodic stripping voltammetry (Ad-DPCSV), and good linearity (r (2)=1.000) was found in the range from 0.5 to 5 ppb with an adsorption time of 120 s. The alloy electrodes were also found to be sensitive to nitrate, and good linearity (r (2)=0.997) was found in the range from 1 mg L(-1) to 100 mg L(-1) using differential pulse voltammetry (DPV) scanning from -450 mV to -1,500 mV. Addition of nitrate in ultrapure water afforded two different peaks related to the successive reductions of nitrate and nitrite. In ammonium buffer solution (pH 8.6) only one peak resulting from reduction of nitrate was observed. Furthermore, the use of alloy electrodes containing 17% Cu was tested in real samples, by installing it in a voltammetric system for monitoring of zinc and lead in a polluted river, the river Deûle, near the town of Douai in northern France. Results were found to be in agreement with parallel measurements carried out by ICP-MS.

Journal Article↗

Progress in pulsed-current Karl Fischer coulometry using diaphragm-free cells.

Factors influencing the accuracy of water determinations using diaphragm-free, pulsed current Karl Fischer (KF) coulometry were investigated with the new Metrohm 756 instrument. Results obtained with commercially available reagents from Riedel-deHaen and Merck were compared with home-made ones that were especially designed to minimize the formation of iodine-consuming reduction products generated in the cathode reaction. Positive errors in the range 2-5% were found for the commercial reagents as compared to 0.2-1% for the home-made ones which were buffered at about pH 10 containing modifiers like chloroform, hexanol or ethylene glycol. Except for the composition of the KF-reagent, the cathode current density and the titration rate were found to be critical parameters for the accuracy of the determinations. For all reagents investigated, the best results were obtained for the maximum generator current 400 mA (corresponding to a current density of 1,400 mA cm(-2)) in combination with a maximum titration rate of 2,000 microg min(-1). Surprisingly, the errors found under optimum conditions for the pulse technique were always somewhat larger than the corresponding values obtained with continuous coulometry.

Journal Article↗

Subspeciation of nickel disulfide by carbon paste electrode voltammetry catalyzed by Ni2+.

In subspeciation of sulfidic nickel, carbon paste electrode voltammetry was developed for the specific determination of Ni3S2 or NiS, but NiS2 was found to be unreactive. Ni2+ in pH 7.2 acetate solution was able to catalyze NiS2 to undergo redox reactions. The cyclic voltammogram showed two anodic peaks at -0.3 and +0.7 V and a cathodic peak at -0.6 V. The first anodic peak at -0.3 V and the cathodic peak were common among the three nickel sulfides, but the second anodic peak at +0.7 V was unique to NiS2. This peak current gave a linear dose response to NiS2 from 40 to 610 microg, with a correlation coefficient of 0.994, and a detection limit of 40 microg.

Carbon↗

Detection of trace radioisotopes in soil, sediment and vegetation by glow discharge mass spectrometry.

The possibility for the determination of some radioisotopes of cesium, strontium, plutonium, uranium and thorium by glow discharge mass spectrometry (GDMS) in soils, sediments and vegetations is investigated. The preparation of samples is described as a combination of the use of a conductive host matrix and a secondary cathode in order to decrease the dilution effect of the blending material for the trace level determination and to gain a stable discharge. Effects of interferences arising from the nature of the conductive host matrix and of the secondary cathode on the sensitivity of the method are discussed. The determination of (137)Cs and (90)Sr has been attempted and the results obtained were in agreement with those from other analytical techniques. Accuracy, internal and external precisions have been also evaluated. GDMS is shown to be a helpful technique for the determination of radioisotopes in environmental samples. Radioisotopes can be determined according to the matrix of the sample (e.g. grass), also in presence of isobaric interferences. However, limitations still exist on the application of GDMS.

Journal Article↗

Optimization of an rf-powered magnetron glow discharge for the trace analysis of glasses and ceramics.

A radiofrequency (rf) powered planar magnetron glow discharge ion source has been designed and coupled to a double-focusing mass spectrometer. Superposition of the electrical field of the plasma in the cathode dark space and the magnetic field obtained from a ring-shaped magnet located directly behind the sample (cathode) form the electron traps and enhance the sputtering and ionization efficiency of the ion source. In order to establish optimum conditions for the trace analysis of nonconducting materials, mass spectrometric studies have been carried out on the ion signal intensities and energy distributions of analyte and discharge gas ions depending on pressure.

Journal Article↗

Linearity, symmetry and additivity of the human eye-movement response to maintained unilateral and bilateral surface galvanic (DC) vestibular stimulation.

Recent studies have shown that, although responses to long-duration, constant-current surface galvanic vestibular stimulation (GVS) show substantial interindividual variability, individual subjects show a reliable, repeatable, idiosyncratic oculomotor response pattern to GVS. It follows that GVS may be a more reliable stimulus than may have been anticipated from the literature. The aim of the present study was to examine the metrics of 3D eye-movement responses to maintained (120 s), unilateral and bilateral surface GVS. Eye movements were measured using computerised video-oculography. Two experiments were conducted: Experiment 1 examined whether the normal response is linear over increasing levels of current; and Experiment 2 examined (1) whether the normal response to surface GVS is symmetrical when comparing stimulated sides, (2) whether the normal response to surface GVS is symmetrical when the polarity of the stimulating current was reversed, and (3) whether there is additivity in the normal response to combinations of unilateral/bilateral surface GVS. Five subjects participated in Experiment 1 and eight subjects participated in Experiment 2. In both experiments, the onset of stimulation produced characteristic eye-movement responses: changes in torsional position with the upper pole of both eyes rolling towards the anode and away from the cathode; together with horizontal and torsional nystagmus with slow phases towards the anode and away from the cathode; and negligible vertical nystagmus. These responses reversed direction at stimulus offset. In the fixation condition of Experiment 1, the magnitude of ocular torsional position (OTP) and torsional nystagmus responses showed a linear relationship over conditions of increasing current strength, as did OTP, torsional and horizontal nystagmus responses in darkness. The results of Experiment 2 showed that responses to unilateral stimulation are symmetrical between stimulated sides, symmetrical between stimulating polarities, and additive (with respect to responses to bilateral stimulation). The principles derived from these findings, as well as those of recent studies, provide a foundation for future work investigating eye-movement responses to surface GVS in patients with known types of vestibular dysfunction.

Adult↗

Manipulation of phosphene thresholds by transcranial direct current stimulation in man.

Transcranial direct current stimulation (tDCS) can modulate the excitability of the human motor cortex, as revealed by the amplitude of the motor-evoked potentials (MEP). The aim of our study has been to produce localized changes of cerebral excitability of the visual cortex in the intact human by weak anodal and cathodal stimulation. For quantification of current-induced excitability changes, we measured phosphene threshold (PT) using short trains of 5-Hz transcranial magnetic stimulation (TMS) pulses in nine healthy subjects before, immediately after, 10 min, and 20 min after the end of tDCS. PTs are suggested as representative values of visual cortex excitability changes. Reduced PT was detected immediately and 10 min after the end of anodal stimulation, while cathodal stimulation resulted in an opposite effect. Our results show that tDCS elicits a transient, reversible excitability alteration of the visual cortex, thus representing a promising tool for neuroplasticity research.

Adult↗

Anodal transcranial direct current stimulation of prefrontal cortex enhances working memory.

Previous studies have claimed that weak transcranial direct current stimulation (tDCS) induces persisting excitability changes in the human motor cortex that can be more pronounced than cortical modulation induced by transcranial magnetic stimulation, but there are no studies that have evaluated the effects of tDCS on working memory. Our aim was to determine whether anodal transcranial direct current stimulation, which enhances brain cortical excitability and activity, would modify performance in a sequential-letter working memory task when administered to the dorsolateral prefrontal cortex (DLPFC). Fifteen subjects underwent a three-back working memory task based on letters. This task was performed during sham and anodal stimulation applied over the left DLPFC. Moreover seven of these subjects performed the same task, but with inverse polarity (cathodal stimulation of the left DLPFC) and anodal stimulation of the primary motor cortex (M1). Our results indicate that only anodal stimulation of the left prefrontal cortex, but not cathodal stimulation of left DLPFC or anodal stimulation of M1, increases the accuracy of the task performance when compared to sham stimulation of the same area. This accuracy enhancement during active stimulation cannot be accounted for by slowed responses, as response times were not changed by stimulation. Our results indicate that left prefrontal anodal stimulation leads to an enhancement of working memory performance. Furthermore, this effect depends on the stimulation polarity and is specific to the site of stimulation. This result may be helpful to develop future interventions aiming at clinical benefits.

Adult↗

Vestibular-evoked electromyographic responses in soleus: a comparison between click and galvanic stimulation.

The aim of this study was to demonstrate, if possible, vestibulospinal reflex responses in soleus using a stimulus known to be capable of exciting vestibular afferents, namely 100-dB (NHL) clicks. We were able to show short-latency electromyographic (EMG) responses after clicks in five of eight normal subjects, and then we compared these responses with those after transmastoid galvanic stimulation (12 normal subjects). Stimulation of the side towards which the head was rotated (i.e. the side facing backwards) with either clicks or the cathode (anode applied to the opposite side) gave an initial excitatory response in soleus, while click or cathodal stimulation of the opposite side (i.e. the side facing forwards) gave an initial inhibitory response. Onset latencies and modulation with changes in postural task were identical for both click- and galvanic-evoked responses. In addition, there was a significant correlation between the amplitudes of the responses in soleus after click and galvanic stimulation (R2=0.72). These similarities suggest that the earliest reflex responses in soleus after clicks and galvanic stimulation may be mediated by a common central pathway. In contrast, there was no correlation between the amplitudes of responses evoked by 100-dB clicks in soleus and those evoked by the same stimulus in the sternocleidomastoid. We conclude that vestibular activation by clicks can evoke reflex responses in lower-limb muscles and these responses have similar characteristics to the earliest responses evoked by galvanic vestibular stimulation.

Acoustic Stimulation↗

Maintained ocular torsion produced by bilateral and unilateral galvanic (DC) vestibular stimulation in humans.

This study was designed to measure ocular movements evoked by galvanic (DC) stimulation using computerised video-oculography. Long duration (>30 s) galvanic vestibular stimulation at currents of up to 5 mA through large-area surface electrodes over the mastoid processes causes maintained changes in the ocular torsional position of both eyes in healthy human subjects. With the subject seated and the head held firmly, torsion was measured by a computer-based image-processing system (VTM). Torsion was recorded in darkness, with or without a single fixation point. With bilateral stimulation, the upper poles of both eyes always torted away from the side of cathode placement and toward the anode. For unilateral stimulation, torsion was directed away from the cathode or toward the anode. The magnitude of ocular torsion was dependent on current strength: with bilateral stimulation the peak torsion was on average 2.88 degrees for 5-mA current intensity compared with 1.58 degrees for 3 mA. A smaller amplitude of torsion was obtained for unilateral stimulation. The average peak torsion was the same for both eyes for all forms of stimulation. Our findings indicate that low-intensity galvanic stimulation evokes ocular torsion in normal subjects, an effect which is consistent with an action on otolith afferents.

Adult↗

Sustained generation of electricity by the spore-forming, Gram-positive, Desulfitobacterium hafniense strain DCB2.

Desulfitobacterium hafniense strain DCB2 generates electricity in microbial fuel cells (MFCs) when humic acids or the humate analog anthraquinone-2,6-disulfonate (AQDS) is added as an electron-carrying mediator. When utilizing formate as fuel, the Gram-positive, spore-forming bacterium generated up to 400 mW/m2 of cathode surface area in a single-chamber MFC with a platinum-containing air-fed cathode. Hydrogen, lactate, pyruvate, and ethanol supported electricity generation, but acetate, propionate, and butyrate did not. Scanning electron microscopy indicated that strain DCB2 colonized the surface of a current-generating anode but not of an unconnected electrode. The electricity was recovered fully within minutes after the exchange of the medium in the anode chamber and within a week after an exposure of a colonized anode to 90 degrees C for 20 min. Of the six strains of Desulfitobacteria tested, all of which would reduce AQDS, only D. hafniense strain DCB2 continued to reduce AQDS and generate electricity for more than 24 h, indicating that reduction of the humate analog alone is insufficient to sustain electrode reduction.

Anthraquinones↗

Intrarenal oxygen tension measured by a modified clark electrode at normal and low blood pressure and after injection of x-ray contrast media.

The oxygen tension (pO2) in the rat kidney was studied using a Clark microelectrode with a guard cathode behind the sensing cathode. The mean (+/- SEM) outer tip diameter of the electrodes used was 5.5 +/- 1.9 microm. The zero-pO2 current amounted to 12.5 +/- 0.9 pA at 37 degrees C; at air saturation it was 252 +/- 22.9 pA. Rats with a systolic blood pressure (BP) above 80 mmHg (where 1 mmHg = 133 Pa) showed an average pO2 in the cortex of 45 +/- 2 mmHg and in the outer medulla of 31 +/-1 mmHg. In rats with a BP below 80 mmHg a paradoxically high outer medullary pO2 of 40 +/- 4 mmHg was found, while the pO2 in the cortex was 27 +/- 4 mmHg. Changes in pO2 were also noted in the renal cortex and outer medulla after intravenous injections of the x-ray contrast medium diatrizoate (370 mg iodine/ml). In rats with normal BP, injection of diatrizoate caused a slight fall in pO2 in the renal cortex, from 42 +/- 4 to 38 +/-4 mmHg. In the medulla pO2 decreased significantly from 34 +/- 6 to 20 +/-4 mmHg. Ringer's solution did not induce any changes.

Animals↗