Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Beta Particles”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Thin layer alpha-Al2O3:C beta dosemeters for the assessment of current dose rate in teeth due to 90Sr intake, and comparison with electron paramagnetic resonance dosimetry.

The use of thin-layer alpha-Al2O3:C thermoluminescent detectors (TLDs) for the assessment of current beta dose rate in human teeth due to 90Sr intake is investigated. The teeth used in this study were collected from members of the Techa river population who were exposed to radiation as a result of releases of the Mayak plutonium production facilities (Southern Urals-Russia) between 1949 and 1956. The beta dose rates from different parts of the tooth (enamel, crown dentine, and root) were determined by storing the detectors over the samples in a shielded environment. The cumulative dose measured by electron paramagnetic resonance (EPR) in different dental tissues is found to be proportional to current dose rate obtained from alpha-Al2O3:C thermoluminescence dosemeters. The retention of 90Sr in various parts of the teeth is discussed.

Aluminum Oxide↗

Design of a finger ring extremity dosemeter based on OSL readout of alpha-Al2O3:C.

A finger-ring dosemeter and reader has been designed that uses OSL readout of alpha-Al2O3:C (aluminium oxide). The use of aluminium oxide is important because it allows the sensitive element of the dosemeter to be a very thin layer that reduces the beta and gamma energy dependence to acceptable levels without compromising the required sensitivity for dose measurement. OSL readout allows the ring dosemeter to be interrogated with minimal disassembly. The ring dosemeter consists of three components: aluminium oxide powder for measurement of dose, an aluminium substrate that gives structure to the ring, and an aluminised Mylar cover to prevent the aluminium oxide from exposure to light. The thicknesses of the three components have been optimised for beta response using the Monte Carlo computer code FLUKA. A reader was also designed and developed that allows the dosemeter to be read after removing the Mylar. Future efforts are discussed.

Aluminum Oxide↗

Energy and directional response for the Harshaw dosemeter holders 8814 and 8891, and its effect on the appropriate radiation qualities for absolute calibration.

The personal dosimetry laboratory at the Norwegian radiation protection authority utilises a two-element dosemeter card for measuring Hp(10) and Hp(0.07), in a Harshaw dosemeter holder type 8814. Energy and directional responses for photons and betas for this holder have been assessed, as well as for the new Harshaw holder type 8891. The energy response characteristics for the 12-1250 keV photon energy range, in terms of TL output per unit Hp(10) and Hp(0.07) have been evaluated. The maximum over-response to under-response ratio for the Hp(10) element was found to be 1.46 for the new type 8891 holder, as compared to 1.55 for the older type 8814. The new holder also displays a more favourable directional response for this element. For the Hp(0.07) element, no significant differences with regard to energy or directional responses were found. Selecting radiation energy for absolute calibration of the Hp(10) and Hp(0.07) elements are discussed.

Beta Particles↗

Monte Carlo determination of age-dependent steady-state dose to red bone marrow and bone from 14C exposure.

Monte Carlo simulations were carried out to calculate the age-dependent dose from the beta decay of 14C to marrow and bone on the basis of a steady-state specific-activity model. A model of the trabecular cavity containing spherical fat cells in a square lattice surrounded by haemopoietic tissue was employed. The age-dependent 14C dose to haemopoietic (red) marrow was estimated taking account of the change in the fat cell size with fat fraction. Allowances were made for the change in the percentage cellularity and distribution of active marrow in the whole skeleton as a function of age. Age-dependent changes in trabecular cavity size and bone composition were found to have only a small effect on dose. Dose rates were estimated under steady-state conditions, for food ingested with a 14C specific activity of 1 Bq g(-1) of C. The equivalent dose rate to the haemopoietic tissue of a 20 year-old adult is 77 microSv a(-1), and 39 microSv a(-1) for a 3-month-old infant. Similarly, the equivalent dose rate to the bone surfaces of an adult is 48 microSv a(-1), and 38 microSv a(-1) for an infant. Therefore, the equivalent dose rate to marrow and bone stem cells increases with age under steady state conditions.

Adipocytes↗

Structure of a physiologically based biokinetic model for use in 14C and organically bound tritium dosimetry.

Physiologically based biokinetic (PBBK) dosimetry models for beta emitters such as 3H and 14C must include rapid turnover compartments which, while they may be minor in terms of dose commitment, can dominate bioassay measurements at early times after intake. In this paper, a consistent PBBK model structure will be described for use in dose assessments for organic 14C and organically bound tritium (OBT), and also for 14CO2, based on the literature of human carbon metabolism, and on direct measurements of human excretion. CO3/HCO3- is a central compartment in carbon metabolism. The 14CO2 biokinetic model described in ICRP Publication 80 for the calculation of dose coefficients was found to omit early components of excretion necessary for the accurate interpretation of bioassay results. Recommendations on the requirements on dosimetry models for intakes of 14C and OBT are made.

Air Pollutants, Radioactive↗

EURADOS trial performance test for personal dosemeters for external beta radiation.

On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU was accomplished. This paper deals with the part of the performance test concerned with exposure to beta radiation. Fifteen dosimetric services participated with whole-body dosemeters intended to measure beta doses (Hp(0.07)) of which 13 used thermoluminescent (TL) detectors and two used photographic films. Eight services participated with extremity dosemeters which all used TL detectors. A description is given of the irradiation set-up, the characteristics of the irradiation fields, the calibration quantity applied and the performance criteria used for the evaluation of the results. The paper discusses in detail the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test.

Beta Particles↗

Direct ion storage dosimetry systems for photon, beta and neutron radiation with instant readout capabilities.

The direct ion storage (DIS) dosemeter is a new type of electronic dosemeter from which the dose information for both Hp(10) and Hp(0.07) can be obtained instantly at the workplace by using an electronic reader unit. The number of readouts is unlimited and the stored information is not affected by the readout procedure. The accumulated dose can also be electronically reset by authorised personnel. The DIS dosemeter represents a potential alternative for replacing the existing film and thermoluminescence dosemeters (TLDs) used in occupational monitoring due to its ease of use and low operating costs. The standard version for normal photon and beta dosimetry, as well as a developmental version for neutron dosimetry, have been characterised in several field studies. Two new small size variations are also introduced, including a contactless readout device and a militarised version optimised for field use.

Air Pollutants, Radioactive↗

Estimation of doses to personnel and patients during endovascular brachytherapy applications.

In the last few years coronary endovascular brachytherapy using gamma- and beta-emitting radionuclides has been established as a standard treatment procedure to prevent restenosis after percutaneous coronary interventions. Direct measurements and calculations were made to determine personnel doses and organ doses of patients due to gamma rays of 192Ir and beta rays of 90Sr/90Y and 32P sources. In general, our results show that the dose levels are low compared with the X-ray exposure from angiography. The dose rate from bremsstrahlung at 1 m distance from a device containing a 90Sr/90Y source of 2.3 GBq is 4 micro Sv h(-1). The skin dose from beta rays during source transfer into and from the patient was estimated with the directional dose equivalent H'(0.07) of 10 micro Sv at 1 m distance from the catheter. By maintaining safe distances, the dose levels can be kept well within annual dose limits.

Beta Particles↗

Angular dependence of the TL reading of thin alpha-Al2O3:C dosemeters exposed to different beta spectra.

The angular dependence of the thermoluminescent (TL) signal of thin alpha-Al2O3:C dosemeters was investigated for a series of beta-emitting radionuclides commonly employed in nuclear medicine and characterised by different mean energies (99Tc, 177Lu, 90Sr/90Y and 90Y). Irradiations were performed in a controlled geometry, using a properly designed irradiator intended to realistically reproduce the situation of exposure of hospital personnel to beta-emitting pharmaceuticals. Under the conditions of extended source and short source to detector distance, the TL signal of thin alpha-Al2O3:C layers per unit irradiation time was observed to be independent on the angle of incidence within acceptable limits, particularly for those radionuclides with maximum energy >500 keV. This property may be easily explained by using simple physical considerations, such as the limited thickness of the dosemeters. The results confirm that these detectors are suitable for beta-ray extremity dose measurements, when the photon contribution is negligible, as in the case considered.

Aluminum↗

Thermoluminescence dosimetric characteristics of beta irradiated salt.

The thermoluminescence (TL) characteristics of sodium chloride (NaCl), known as common salt, used for cooking purposes (iodised salt), have been studied in the present paper considering its usage as an 'accidental dosemeter' in the case of a nuclear fallout. TL characteristics of common salt have been examined under excitation with a beta dose of 20 Gy from a 90Sr beta source. The salt specimens are used in the form of discs. The average salt grain that sticks to the disc is measured to be approximately 1 mg. The TL of the beta irradiated salt is recorded in the conventional TL apparatus. Initially three peaks were observed at 133, 205 and 238 degrees C. All three peaks are well resolved, having maximum intensity at 238 degrees C. The material under investigation, i.e. 'common salt' possesses many good dosimetric properties and therefore this can be considered as an 'accidental dosemeter'.

Beta Particles↗

Compact fluorescent lamp phosphors in accidental radiation monitoring.

The application of lamp phosphors for accidental dosimetry is a new concept. Since the materials used in fluorescent lamps are good photo luminescent materials, if one can either use the inherent defects present in the phosphor or add suitable modifiers to induce thermoluminescence (TL) in these phosphors, then the device (fluorescent lamp) can be used as an accidental dosemeter. In continuation of our search for a suitable phosphor material, which can serve both as an efficient lamp phosphor and as a good radiation monitoring device, detailed examination has been carried out on cerium and terbium-doped lanthanum phosphate material. A (90)Sr beta source with 50 mCi strength (1.85 GBq) was used as the irradiation source for TL studies. The TL response as a function of dose received was examined for all phosphors used and it was observed that the intensity of the TL peak vs. dose received was a linear function in the dose range 0.1-200 Gy in each case. Incidentally LaPO(4): Ce,Tb is a component of the compact fluorescent lamp marketed recently as an energy bright light source. Besides having very good luminescence efficiency, good dosimetric properties of these phosphors render them useful for their use in accidental dosimetry also.

Beta Particles↗

Thermoluminescence response of new KCl(X)Br(1-X):EuCl3 sintered phosphors exposed to beta and gamma radiation.

Alkali halides crystals have been the subject of intense research for an understanding of their radiation-induced defects and luminescence properties. They exhibit noteworthy thermoluminescence (TL) properties when exposed to ionising radiation. Currently, these materials are grown employing expensive and rather complicated techniques. In this work, the results on the TL properties of new alkali halides phosphors fabricated by a simple and inexpensive procedure are presented. The samples were made by mixing KCl, KBr and EuCl3 salts, and compressing them at a pressure of 3.2 x 10(7) Pa during 3 min, followed by sintering at 700 degrees C during 24 h under air atmosphere. The dosimetric response of the samples showed an increase with radiation dose in the 1.5-20.0 Gy dose range for beta and gamma radiation. The TL glow curves in sintered samples presented significant differences in their peak structures compared with monocrystalline samples, indicating that the nature of the trapping states and the recombination mechanisms may be different.

Beta Particles↗

Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5 mg cm(-2) PVC ring holder. Dosimetric performance was analysed according to the ISO 12794 standard and compared with 240 mg cm(-2) TLD-100 measurements. In particular, the energy response was obtained for ISO narrow X-ray spectra, (137)Cs, (60)Co, (204)Tl and (90)Sr/(90)Y. From these measurements a mean calibration factor was calculated to estimate H(p)(0.07). Subsequently, the performance of the dosemeters was checked for a set of 10 different mixed photon and beta-photon fields. The study shows that the proposed dosemeters can estimate H(p)(0.07) in a wide range of mixed beta-photon fields with a maximum deviation from the given dose of 30% and an overall uncertainty of the order of 25% (k = 1). However, the results also highlight a large variability among the different thin detectors and, thus, the standard TLD-100 material is recommended whenever the workplace does not include low-energy beta radiation.

Beta Particles↗

Experimental determination of the dose deposition profile of a 90Sr beta source.

Three different methods for characterising the dose deposition profile of a (90)Sr/(90)Y radioactive source are described: GAFChromic film dosimetry, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL). For the film measurements, GAFChromic film samples were stacked at different depths between polyethylene terephthalate (PET) foils. For TL, the thickness of a TLD-500 dosemeter was gradually reduced by polishing and the TL from chips of different thickness was used in conjunction with a mathematical model based on the exponential attenuation of dose inside the crystal to determine the decay constant for the dose-depth profile. Finally, an OSL reader with confocal stimulation / detection capabilities was used to map the two-dimensional dose distribution in TLD-500 dosemeters as a function of depth. The shapes of the dose deposition profiles obtained from all the investigated methods are in good agreement.

Beta Particles↗

Optically stimulated luminescence dosimetry performance of natural Brazilian topaz exposed to beta radiation.

Optically stimulated luminescence (OSL) has become the technique of choice in many areas of dosimetry. Natural materials like topaz are available in large quantities in Brazil and other countries. They have been studied to investigate the possibility of use its thermoluminescence (TL) properties for dosimetric applications. In this work, we investigate the possibility of utilising the OSL properties of natural Brazilian topaz in dosimetry. Bulk topaz samples were exposed to doses up to 100 Gy of beta radiation and the integrated OSL as a function of the dose showed linear behaviour. The fading occurs in the first 20 min after irradiation but it is <6% of the integrated OSL measured shortly after exposure. We conclude that natural colourless topaz is a very suitable phosphor for OSL dosimetry.

Beta Particles↗

Preliminary dosimetric characterisation of thermoluminescent materials for beta radiation monitoring at nuclear medicine services.

Beta emitters are widely used in nuclear medicine for diagnostic and therapeutic purposes. The critical groups exposed to a radioactive patient include the staff, other patients and members of the public accompanying the patient. The aim of this work is to characterise thermoluminescent (TL) materials for the staff monitoring of nuclear medicine services that manipulate beta radiation solutions of (153)Sm. This study was performed using CaSO(4):Dy + Teflon pellets, produced at IPEN, with different dimensions. For the dosimetric characterisation, these TL dosemeters were exposed to gamma source ((60)Co) and to beta sealed sources ((90)Sr + (90)Y, (204)Tl and (147)Pm) and to a non-sealed source ((153)Sm). Results were obtained related to reproducibility, lower detection limits, calibration curves, angle and energy dependence of response. All tested materials show usefulness for monitoring of workers exposed to beta radiation.

Beta Particles↗

Beta radiation exposure of medical staff and implications for extremity dose monitoring.

Sealed and unsealed beta radiation sources come into use to a greater extent in radiation therapy, e.g. for treating inflammatory joint diseases by radiosynoviorthesis (RSO), by injecting 90Y, 186Re or 169Er-solutions. Sealed 90Sr/90Y and 32P-sources or 188Re-liquid-filled balloon catheter are applied in vascular brachytherapy. Recently, 90Y-labelled antibodies are being successfully used in radioimmunotherapy (RIT) of malign lymphoma. Such practices require handling of high activities at small distances to the skin. Thus, the medical staff may be exposed to high beta doses. Investigations of the extremity exposure were performed at several workplaces, in particular during RSO treatments. The local skin dose (LSD), Hp(0,07), was measured with thin-layer TLD (LiF:Mg,P,Cu) fixed to the fingers (TLD-tapes). The findings indicate that the exposure of the staff can exceed the annual dose limit of 500 mSv when working at low protection standard. Routine monitoring of the extremity exposures with ring dosemeters appropriate to beta radiation and provided by the approved German dosimetry services was found to be needed. But even monitoring with these official 'beta-dosemeters' does mostly not give suitable results to demonstrate compliance with the dose limit. A study was conducted at RSO-workplaces in order reveal a correlation between doses measured with ring dosemeters and the maximum LSD obtained from the TLD-tapes. The results are discussed and conclusions for routine monitoring are drawn.

Beta Particles↗

Does metabolic radiolabeling stimulate the stress response? Gene expression profiling reveals differential cellular responses to internal beta vs. external gamma radiation.

DNA microarray analyses were used to investigate the effect of cell-incorporated 35S-methionine on human colorectal carcinoma cells. This beta-radiation-induced gene expression profile was compared with that induced by external gamma-radiation. The extent of DNA fragmentation was used as a biomarker to determine the external gamma dose that was bioequivalent to that received by cells incubated in medium containing 35S-methionine. Studies showed that 35S-methionine at 100 microCi/mL induced a much more robust transcriptional response than gamma-radiation (2000 cGy) when evaluated 2 h after the labeling or irradiation period. The cellular response to internal beta-radiation was greater not only with respect to the number of genes induced, but also with respect to the level of gene induction. Not surprisingly, the induced genes overlapped with the set of gamma-responsive genes. However, a distinct beta-gene induction profile that included a large number of cell adhesion proteins was also observed. Taken together, these studies demonstrate that metabolic incorporation of a low energy beta-emitter, such as 35S-methionine, can globally influence a diverse set of cellular activities that can, in turn, affect the outcome of many experiments by altering the cell cycle, metabolic, signaling, or redox status (set point) of the cell. Additional studies of the mechanism of beta-induced proliferation arrest and cell death and of the significance of its differential gene induction/repression profile in comparison to pulsed gamma-irradiation may lead to new insights into the ways in which ionizing radiation can interact with cells.

Beta Particles↗