At least 1,135 records · Page 63Linked to original sources

Quantification of the neuromuscular blocking agent rocuronium and its putative metabolite 17-desacetylrocuronium in heparinized plasma by capillary gas chromatography using a nitrogen sensitive detector.

We have developed a sensitive and specific capillary GC (cGC) assay for the quantification of the quarternary aminosteroidal compound rocuronium (roc), a neuromuscular blocking agent, and its putative metabolite 17-desacetylrocuronium (17OH-roc), using 3-desacetylvecuronium (3OH-vec) as an internal standard (I.S.). This novel method has been applied to a pharmacokinetic study with roc, monitoring sixty patients who were classified according to four different body mass index (BMI) groups. The isolation of these drugs from plasma was carried out using a dichloromethane liquid-liquid extraction after ion-pairing of the positively charged ammonium compounds with iodide. To achieve thermal stability, tert.-butyldimethylsilyl-ethers were formed at the 3OH- and 17OH-steroidal positions by reaction with N-methyl-N-(tert.-butyldimethylsilyl)-trifluoroacetamide at 70 degrees C overnight. An automated cGC system fitted with a nitrogen sensitive detector with a specially prepared glass phase bead and a computer controlled data handling system was used to analyze and quantify the compounds, which were separated on a DB1 capillary column with helium as the carrier gas and a temperature program ranging from 120 to 300 degrees C. The method is linear for 50-6400 ng/ml for roc and 80-6400 ng/ml for 17OH-roc. The detection limits were 10 ng/ml for roc and 50 ng/ml for 17OH-roc. The lower limit of quantification was 50 ng/ml for roc and 80 ng/ml for 17OH-roc. Intra-assay coefficients of variation (C.V.s) were 10% and 15% and the inter-assay C.V.s 8-18% and 16-21% for roc and 17OH-roc, respectively.

Androstanols↗

Rapid and simple micromethod for the quantification of fluindione in human plasma using high-performance liquid chromatography.

A new high-performance liquid chromatographic (HPLC) assay without any extraction procedure was developed for the quantification of fluindione in plasma using a 100-microl sample volume and coumarin as the internal standard. A deproteinization procedure was coupled with a reversed-phase HPLC separation using a 250x4.6 mm I.D. C18 column and a UV detector set at 280 nm. Peak height ratios were linear over the range 0.05 to 10 microg/ml (correlation coefficient >0.998). The method was found to be highly reproducible, as indicated by the low value obtained for the coefficient of variation: C.V. < or = 6.1% (n = 10). The limit of quantification, estimated under the described conditions at a signal-to-noise ratio of three and with a C.V. lower than 20% for precision and accuracy, was 0.025 microg/ml. The total turnaround time was 25 min. After storage of blood samples at concentrations of 0.1, 0.5 and 2.5 microg/ml at room temperature and exposition to light for 120 h, no degradation of fluindione occurred. This micromethod is simple (no extraction step), fast and currently is being used for drug monitoring.

Anticoagulants↗

Quantification of penicillin-G and procaine in equine urine and plasma using high-performance liquid chromatography.

A rapid and sensitive method for the extraction and quantification of penicillin-G and procaine in horse urine and plasma samples has been successfully developed. The method involves the use of solid-phase extraction (SPE) for penicillin-G, liquid-liquid extraction (LLE) for procaine, and high-performance liquid chromatography (HPLC) for the quantification of penicillin-G and procaine. The new method described here has been successfully applied in the pharmacokinetic studies of procaine, penicillin-G and procaine-penicillin-G administrations in the horse.

Animals↗

Application of cloud-point extraction-reversed-phase high-performance liquid chromatography. A preliminary study of the extraction and quantification of vitamins A and E in human serum and whole blood.

Methods available for quantification of vitamins A and E in serum or blood requires preconcentration and clean-up by liquid-liquid extraction, evaporation of the extract, and reconstitution of the extract in a solvent of choice before analysis. This process not only involves the use of toxic organic solvents but also requires a long sample preparation time. The lipids and other non-polar coextractants often require additional steps for sample clean-up and evaporation, which may cause sample losses. The use of cloud-point extraction eliminates most of these sample clean-up problems. We recently demonstrated that cloud-point extraction (CPE) can be used for extraction and quantification of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated dibenzo-p-dioxins (PCDDs) from human serum. We now demonstrate how CPE can be used with human serum and blood, at volumes as low as 50 microl, and report a methodology for extracting and quantifying two clinically important vitamins, (A and E) from human serum and blood. Vitamins A and E were extracted from human serum and blood by using Genapol X-80 as the cloud-point extractant under salting out conditions. Serum and blood samples were diluted in organic-free water to get sufficiently large sample volumes for CPE. The surfactant-rich phases were separated by centrifugation, and the samples were analyzed by HPLC-UV after deleterious coextractants were removed by precipitating them with acetonitrile. The recoveries of spiked vitamins A and E were found to be 85.6+/-0.4% and 82.6+/-5.2%, respectively. The average concentration of vitamins A and E in a serum pool after correction for recoveries were found to be 43.4+/-1.8 microg/dl (1.5+/-0.1 micromol/l) and 564.3+/-65.3 microg/dl (13.1+/-1.5 micromol/l), respectively. Vitamin A and E concentrations in whole blood were found to be 26.3+/-0.4 microg/dl (0.92+/-0.01 micromol/l) and 457.5+/-15.6 microg/dl (10.6+/-0.4 micromol/l), respectively. These values are comparable with those obtained by the reference method used at the Centers for Disease Control and Prevention. The success of the preliminary study will lead to a comprehensive validation of this method for vitamins A and E in serum and blood.

Acetonitriles↗

High-performance liquid chromatography-mass spectrometry for the quantification of nortriptyline and 10-hydroxynortriptyline in plasma.

A highly sensitive and selective method for the quantification of nortriptyline and its major 10-hydroxy metabolite in plasma is described. The method is based on liquid-liquid extraction in combination with acid dehydration of the 10-hydroxy metabolite to the less polar 10,11-dehydronortriptyline. Deuterium labelled internal standards ([2H4]NT and [2H3]10-OH-NT) were used and the compounds were separated by reversed-phase HPLC and detected using atmospheric pressure chemical ionisation and mass spectrometry. The limit of quantification was 0.8 ng/ml for both compounds. A 1-ml volume of plasma was used for analysis in the concentration range 0.8-32 ng/ml. The within- and between-day coefficients of variation were 11% in the low, 1.6 ng/ml range, and 7% at 8 ng ml/ml. Using this method it was possible to quantify plasma concentrations for 168 h following a single oral dose of 25 mg of nortriptyline with good accuracy and precision.

Chromatography, High Pressure Liquid↗

Extraction and quantification of nicardipine in human plasma.

A novel simple method of extraction, separation, identification and quantification of nicardipine in human plasma samples was completely studied. The human plasma samples were initially purified by solid-phase extraction (SPE) using a C18 cartridge. The extracted samples were separated and nicardipine present in the samples was quantified by high-performance liquid chromatography (HPLC) on a reversed-phase C18 column employing a mobile phase consisting of 60% (v/v) acetonitrile in 0.02 M NaH2PO4 with pH of 6.3 and a variable wavelength UV detector set at 254 nm. The recovery of nicardipine from plasma samples using selective SPE was 91+/-6.0% and had less interfering compounds in the HPLC analysis compared to the use of liquid-liquid (L/L) extraction. In the HPLC analysis, examining the effect of pH values of the mobile phase on the capacity factor (k') of nicardipine revealed a method for selecting a critical k' value of nicardipine to eliminate interfering peaks near the peak specific to the analyte. This method for quantification of nicardipine in human plasma samples was suitable for studying the pharmacokinetic profile of nicardipine administered as an intravenous bolus to cardiac surgical patients.

Antihypertensive Agents↗

Rapid quantification of indinavir in human plasma by high-performance liquid chromatography with ultraviolet detection.

A rapid, sensitive and specific high-performance liquid chromatography (HPLC) procedure for the quantification of indinavir, a potent human immunodeficiency virus (HIV) protease inhibitor, in human plasma is described. Following C18 solid-phase extraction, indinavir was chromatographed on a reversed-phase C8 column using a simple binary mobile phase of phosphate buffer-acetonitrile (60:40, v/v). UV detection at 210 nm led to an adequate sensitivity without interference from endogenous matrix components. The limit of quantification was 25 ng/ml with a 0.1 ml plasma sample. The standard curve was linear across the range from 25 to 2500 ng/ml with an average recovery of 91.4%. The mean relative standard deviations for concentrations within the standard curve ranged between 1.4 and 9.7%. Quality control standards gave satisfactory intra- and inter-assay precision (R.S.D. from 3.5 to 15.8%) and accuracy within 15% of the nominal concentration. Sample handling experiments, including HIV heat inactivation, demonstrated analyte stability under expected handling processes. The assay is suitable for the analysis of samples from adult and pediatric patients infected with HIV.

Adult↗

High-performance liquid chromatographic assay with a simple extraction procedure for sensitive quantification of mycophenolic acid in rat and human plasma.

We describe a novel sensitive and simplified gradient HPLC assay for quantification of the immunosuppressant mycophenolic acid (MPA) in rat and human plasma. In contrast to previously reported MPA assays, our method used a single step extraction comprising addition of acetonitrile, which contained phenolphthalein glucoronic acid as internal standard, for protein precipitation. Linearity: 0.1-100 microg/ml (r2>0.999), mean recoveries: MPA 98.0%, internal standard 105.2%, mean intra-day precision: 4.3%, mean day-to-day precision: 4.3%, mean day-to-day accuracy: -1.5%. Sensitivity was sufficient to allow for quantification of mycophenolic acid in as little as 50 microl plasma.

Animals↗

High-speed spectroscopic imaging for cancellous bone marrow R(2)* mapping and lipid quantification.

In this work an interleaved multiple-gradient-echo chemical shift imaging (IMGE-CSI) technique was designed, implemented and evaluated at 1.5 and 4T for high-resolution lipid quantification and R(2)* measurement in-vivo. The method is analogous to echo planar CSI but utilizes conventional gradient echoes, exploiting the principle of spectroscopic bandwidth extension by interleaving temporally offset gradient-echo trains. It is shown that IMGE-CSI is able to measure true fat volume fraction in oil/water mixtures with high accuracy, not possible with Dixon-type methods which approximate the spectrum as consisting of only two spectral components. Correlation of the CSI- derived volume fractions with volumetry afforded r(2) > 0.99 with a slope of 0.98. The method is shown to be able to quantify regional variations in bone marrow composition in vivo with a spatial resolution of 2.5 x 2.5 x 5 mm(3.) R(2)* was obtained by multi-line spectral curve fitting. For the measurement of R(2)* in cancellous bone marrow the method is shown to agree well with time-domain fitting techniques but is superior in instances where the marrow has both hematopoietic and fatty constituents. Finally, excellent inter-scan reproducibility (1% coefficient of variation for global means and medians) was achieved, yielding r(2) = 0.98 of the test-retest correlation for three scans in four test subjects. In conclusion, IMGE-CSI is found to enable highly accurate lipid quantification and measurement of cancellous bone marrow R(2)* at spatial resolutions and scan times typical of standard clinical protocols.

Bone Marrow↗

The effect of orientation on quantification of muscle creatine by 1H MR spectroscopy.

Creatine is a central energy metabolite whose N-CH3 group can be detected with 1H MR spectroscopy (1H MRS) with relatively high sensitivity. Prior studies suggest that muscle fiber orientation can influence the appearance of other resonances attributed to total creatine (CR). Our purpose was to determine whether muscle fiber orientation affects muscle CR concentration quantification by 1H MRS with the commonly used N-CH3 resonance at 3.0 ppm. Skeletal muscle CR was quantified with water-referenced 1H MRS in normal subjects with different forearm muscle orientations relative to the static magnetic field at 1.5T. There were no significant differences in mean total [CR] in two different series of experiments separately including two orthogonal orientations and four orientations (0 degrees, 30 degrees, 60 degrees, 90 degrees) of the forearm relative to the static field using either short (TE = 15 ms) or long (TE = 100 ms) echo times for voxels containing or centered on the same tissues. Subtle differences in CR line-width and T2 correction factors were observed with orientation. These observations are consistent with the primary hypothesis that careful water-referenced [CR] quantification, accounting for T2 effects and using the N-CH3 peak at 3.0ppm, is not affected by muscle orientation.

Creatine↗

Adaptive total linear least square method for quantification of mean transit time in brain perfusion MRI.

Absolute quantification of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) are of great relevance for clinical applications. One of the widely used methods for quantification of these parameters is gamma-variate fitting. Traditional nonlinear regression methods for gamma-variate fitting are inaccurate and computationally demanding. In this study, we developed an adaptive total least square method (ATSSL) to fit a gamma-variate function to the delayed concentration-time course. For each concentration-time curve, the beginning and ending time point of the curve are adaptively determined online. After the curves were fitted, a robust method for automatically determination of arterial input function (AIF) from whole and region of interest (ROI) was developed. Using the obtained AIF and fitted gamma-variate concentration-time curve, the MTT, CBV, and CBF were calculated by utilizing singular value decomposition algorithm. Computer simulations show that the suggested method is adaptive, reliable, and insensitive to noise. Comparison with the traditional nonlinear regression method indicated that the presented method is more accurate and faster to determine the CBV, CBF and MTT.

Brain↗

Absolute metabolite quantification by in vivo NMR spectroscopy: I. Introduction, objectives and activities of a concerted action in biomedical research.

By utilizing achievements and results of two previous concerted research projects on magnetic resonance imaging and spectroscopy (MRS), the EU BIOMED 1 Concerted Action on "Cancer and brain disease characterization and therapy assessment by quantitative MRS" was specifically aimed at: 1) developing at a multicentre level harmonized methodologies and protocols for quantitative and reproducible MRS measurements, as a basis for validating these procedures in well controlled clinical and experimental conditions; and 2) providing multicentre critical reviews on the present understanding of the significance of MRS parameters as possible new markers of diagnosis, prognosis and response to therapy. The programme comprised the following main areas of collaborative research and multicentre evaluation: a) development of methods and protocols for quality assessment, calibration and absolute metabolite quantification in in vivo localized, volume-selective MRS; b) design and validation of a new method for assessing localization performance in spectroscopic imaging (MRSI); c) interlaboratory comparison of different methods of signal processing and data analysis, for improving signal quantification in vivo and in vitro MRS spectra; d) quality assessment of high resolution MRS analyses of biological fluids; e) protocol for assembling a pilot data base of MR spectra of tumour extracts for pattern recognition analysis; f) multicentre review on evaluation of the significance of MRS parameters in monitoring lipid metabolism and function in cancer; and g) multicentre review on evaluation of drug pharmacokinetics and metabolism using MRS. The main results and conclusions of four multi-centre trials on items (a), (b) and (c), which involved 24 teams, are reported in the accompanying papers of this series.

Brain↗

Scan optimization of gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries with multiple bolus injections and in vitro validation of stenosis quantification.

In this study, a T1-weighted three-dimensional (3D) spoiled gradient-echo scanning protocol was developed to image the complete arterial system of the pelvis and both legs along their entire length in patients with peripheral arterial disease. Three adjacent stations were to be acquired consecutively, with some overlap, to image the entire area of interest; per station one gadolinium (Gd) contrast bolus would be administered. In an in vitro phantom study, the scanning protocol was optimized. The optimal flip angle was found to be 50 degrees. Also, the optimal scan delay was chosen to be equal to the arrival time of the contrast bolus, thereby minimizing artifacts. Three contrast bolus injections showed sufficient enhancement of the vessels after image subtraction. Finally, stenosis quantification by manual caliper was performed by five observers in the magnetic resonance angiography (MRA) images and correlated with the percent diameter reduction determined by quantitative angiography from corresponding X-ray images. The MRA measurements were reproducible, and intra- and interobserver variabilities were statistically non-significant (p=0.54 and p=0.12, respectively). Stenosis quantification performed by four observers showed a good correlation with the X-ray-derived values (rp > 0.90, p < 0.02); the results from one observer were not significantly correlated. Five patients with proven peripheral disease were investigated with this new MRA scanning protocol, using standard hardware and software. The images were of good quality, which allowed adequate clinical evaluation; the original diagnoses obtained from X-ray examinations, were confirmed with MRA. In conclusion, peripheral arterial disease can be evaluated adequately with this magnetic resonance scanning protocol.

Adult↗

Rapid quantification of iodopropynyl butylcarbamate as the preservative in cosmetic formulations using high-performance liquid chromatography-electrospray mass spectrometry.

A simple, rapid and reproducible method for identification and quantification of iodopropynyl butylcarbamate (IPBC) in different cosmetic formulations is presented. The determination was carried out using a high-performance liquid chromatography (HPLC) procedure on a reversed phase column coupled to a single quadrupole mass spectrometer (MS) via an electrospray ionization (ESI) interface. Detection was performed in the positive selected ion-monitoring mode. In methanol/water extracts from different cosmetic formulations a detection limit between 50 and 100 ng/g could be achieved. A routine analytical procedure could be set up with good quantification reliability (relative standard deviation between 0.9 and 2.9%).

Anti-Infective Agents↗

Quantification of the anti-leukemia drug STI571 (Gleevec) and its metabolite (CGP 74588) in monkey plasma using a semi-automated solid phase extraction procedure and liquid chromatography-tandem mass spectrometry.

Signal Transduction Inhibitor 571 (STI571, formerly known as CGP 57148B) or Gleevec received fast track approval by the US Food and Drug Administration (FDA) for treatment of chronic myeloid leukemia (CML). STI571 (Gleevec) is a revolutionary and promising new oral therapy for CML, which functions at the molecular level with high specificity. The dramatic improvement in efficacy compared with existing treatments prompted an equally profound increase in the pace of development of Gleevec. The duration from first dose in man to completion of the New Drug Application (NDA) filing was less than 3 years. In addition, recently, FDA approved Gleevec for the treatment of gastrointestinal stromal tumor (GIST). In order to support all toxicokinetic (TK) studies with sufficient speed to meet various target dates, a semi-automated procedure using solid phase extraction (SPE) was developed and validated. A Packard Multi-Probe I and a SPE step in a 96-well plate format were utilized. A 3M Empore octyl (C(8))-standard density 96-well plate was used for plasma sample extraction. A Sciex API 3000 triple quadrupole mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface operated in positive ion mode was used for detection. Lower limits of quantification of 1.00 and 2.00 ng/ml were attained for STI571 and its metabolite, CGP 74588, respectively. The method proved to be rugged and allowed the simultaneous quantification of STI571 and CGP 74588 in monkey plasma. Herein, assay development, validation, and representative concentration-time profiles obtained from TK studies are presented.

Administration, Oral↗

A sensitive method for the quantification of fluticasone propionate in human plasma by high-performance liquid chromatography/atmospheric pressure chemical ionisation mass spectrometry.

A highly sensitive and selective method has been developed for the quantification of fluticasone propionate (FP) in human plasma. The drug was isolated from human plasma using C18 solid-phase extraction cartridges. The analysis was based on high-performance liquid chromatography/atmospheric pressure chemical ionisation mass spectrometry (HPLC/APCI/MS), using the 22R epimer of budesonide (BUD) acetate, synthesised using acetic anhydride, as internal standard. The mass spectrometer was operated in APCI mode with selected ions at tune masses of 473.2 and 501.2 m/z, corresponding to the MH+ of acetylated (22R)BUD and FP, respectively. The mobile phase used was a mixture of 50% ethanol in water with a flow rate of 0.45 ml min-1. The system was optimised by tuning the capillary and tube lens with a concentrated solution of FP. The recovery of FP from human plasma was 86.3%. Linearity of response was obtained over the concentration range 0.2-4.0 ng ml-1. The intra-assay and inter-assay variability were 6.3 and 2.9%, respectively. The lower limit of quantification was 0.2 ng ml-1 when a solid-phase extraction preceded the HPLC/APCI/MS.

Androstadienes↗

Validation of an LC-MS assay for the quantification of the enantiomers of Org 4428 in human plasma.

A sensitive and selective liquid chromatographic mass spectrometric assay has been validated for the quantification of Org 4428 enantiomers in human plasma. The assay employs n-hexane extraction from alkalinized plasma, separation on a narrow-bore enantioselective normal phase Chiralpak AD column and APCI MS-MS detection. The lower limit of quantification is 0.5 ng ml-1 plasma for the individual enantiomers.

Adrenergic Uptake Inhibitors↗

Noninvasive quantification of stenotic semilunar valve areas by Doppler echocardiography.

Fourteen patients, aged 1 month to 13 years, with congenital semilunar valve stenosis (11 pulmonary and 3 aortic) were studied for orifice area quantification calculated from a Doppler echocardiographic equation: Area = SV/0.88 X V2 X VET, where SV = stroke volume, V2 = maximal velocity and VET = ventricular ejection time. Results from individual measurements used in this formula and derived area were compared with individual results from cardiac catheterization and valve area derived from the Gorlin formula. Ventricular ejection time by cardiac catheterization ranged from 0.17 to 0.44 second (mean +/- standard deviation [SD] 0.27 +/- 0.09), and by Doppler study from 0.20 to 0.41 second (mean +/- SD 0.29 +/- 0.06) (r = 0.65, standard error of the estimate [SEE] = 0.03, y = 0.149 + 0.528x). Pressure gradient by catheterization ranged from 30 to 125 mm Hg (mean +/- SD 56.6 +/- 33.1), and by Doppler study from 17.6 to 100 mm Hg (mean +/- SD 46.8 +/- 27.9) (r = 0.91, SEE = 8.8, y = 1.23 + 0.904x). Stroke volume was measured by Doppler study simultaneously with cardiac catheterization in nine patients; results at cardiac catheterization with thermodilution measurements (cardiac output/heart rate) ranged from 5.5 to 53.4 cc (mean +/- SD 24.7 +/- 20), and by Doppler study from 5.8 to 46.9 cc (mean +/- SD 23 +/- 18) (r = 0.96, SEE = 3.5). Area quantification was performed in two ways. In Group 1, heart rate-matched stroke volumes from cardiac catheterization were used in the derived equation for Doppler study (all patients). In Group 2, the stroke volume used was that obtained by Doppler study, which was performed simultaneously with cardiac catheterization (nine patients).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗