Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Neuromuscular function of the latissimus dorsi muscle in goats after dynamic cardiomyoplasty.

Skeletal muscle deterioration is emerging as a limitation to long-term cardiac assist by dynamic cardiomyoplasty. Chronic electrical stimulation of in situ skeletal muscle showed that ischemia, decreased muscle preload, muscle overuse, and chronic electrical stimulation are factors for muscle deterioration. Transposition around the heart has been associated with signs of muscle denervation after chronic electrical stimulation. To evaluate latissimus dorsi muscle neuromuscular function after longterm dynamic cardiomyoplasty, we performed neuromuscular functional analysis and histology on the latissimus dorsi muscle and thoracodorsal nerve of six normal goats and six goats after 6 months of dynamic cardiomyoplasty. Electromyographic analysis showed positive sharp waves and fibrillation potentials in the latissimus dorsi of three goats from the dynamic cardiomyoplasty group. Conduction velocity of the thoracodorsal nerve of goats from the dynamic cardiomyoplasty group (58.32+/-9.80 m/s) was reduced compared to the goats from the control group (71.48+/-5.71 m/s, P = 0.02). Histologic changes in skeletal muscle were compatible with denervation. Loss of myelin sheaths, collapse of endoneurial connective tissue, and solitary foci of axonophagia and myelinophagia further documented severe injury to the thoracodorsal nerve in goats from the dynamic cardiomyoplasty group. The latissimus dorsi muscle wrap was denervated after long-term dynamic cardiomyoplasty. Traction on the neurovascular pedicle at each contraction of the transposed muscle may induce afferent axonal injury of the thoracodorsal nerve resulting in diminished muscular function.

Animals↗

Effect of felodipine on the myogenic response to dynamic stretch in vascular smooth muscle.

In the present experiments we examined the effect of felodipine, a vasoselective dihydropyridine calcium antagonist, on contractile responses to dynamic and static stretch of the isolated portal vein of the rat. Dynamic stretch was applied to the vascular smooth muscle at graded rates (from 0.5-1.5% muscle length s-1). Earlier observations (Johansson & Mellander 1975) of a rate-dependent excitation of the vascular smooth muscle by dynamic stretch were confirmed. Addition of felodipine, 3 nM, reduced the spontaneous activity at static lengths to about 50% but resulted in much stronger inhibition of the dynamic stretch responses. Particularly the rate-dependent increase in active force was no longer evident since the response at high rates of passive lengthening was most clearly reduced by felodipine. By contrast, lowering of the extracellular Ca2+ concentration resulted in a comparable attenuation of the spontaneous contractile activity and of the dynamic stretch responses which still showed the typical rate dependence. Therefore, the pronounced inhibition by felodipine of the dynamic myogenic reactivity of the rat portal vein appeared to be a specific effect and not simply related to the overall reduction in contractile activity. We suggest that felodipine, in addition to its inhibition of action potentials and excitation-contraction coupling may exert a special negative influence on the mechano-electrical coupling, i.e. the process that couples dynamic stretch of the vascular smooth muscle to membrane excitation.

Action Potentials↗

The effects of suxamethonium and acetylcholine on the behaviour of cat muscle spindles during dynamics stretching, and during fusimotor stimulation.

1. The responses of primary and secondary afferent fibres from muscle spindles in cat soleus were studied during constant velocity stretching.2. Intravenous Suxamethonium (SCh) caused a large increase in the response of the primary afferents to the dynamic phase of stretching, and a smaller increase in their response to static extension. The effects of SCh were similar to the effects of dynamic fusimotor stimulation.3. Increasing doses of SCh increased the response of primary afferents to dynamic stretching up to a point, but a peak discharge frequency was encountered beyond which the afferent fibre could not be induced to discharge.4. Suxamethonium increased the response of the secondary afferent fibres by a smaller amount than the primaries, and in particular caused a smaller increase in the response to dynamic extension.5. Acetylcholine given by close arterial injection had an effect similar to the effect of SCh.6. The effects of static and dynamic fusimotor stimulation on the response of primary afferents summed with the effects of small doses of SCh. When large amounts of SCh were used fusimotor stimulation sometimes had no further effect on the afferent discharge. It was not possible to say whether the fusimotor activity was then inhibited, or submerged in the SCh activity.7. The actions of SCh and of acetylcholine emphasized the differences in response of primary and secondary afferent endings to dynamic stretching. The use of these drugs enabled us to classify fibres of intermediate conduction velocity.8. Suxamethonium is known to activate slow muscle fibre systems with distributed nerve endings. The similarity between dynamic fusimotor activity and the effect of SCh suggests that the dyanimic fusimotor fibres act on slow intrafusal muscle fibres through multiple distributed endings.

Acetylcholine↗

Generalized five-dimensional dynamic and spectral factor analysis.

We have generalized the spectral factor analysis and the factor analysis of dynamic sequences (FADS) in SPECT imaging to a five-dimensional general factor analysis model (5D-GFA), where the five dimensions are the three spatial dimensions, photon energy, and time. The generalized model yields a significant advantage in terms of the ratio of the number of equations to that of unknowns in the factor analysis problem in dynamic SPECT studies. We solved the 5D model using a least-squares approach. In addition to the traditional non-negativity constraints, we constrained the solution using a priori knowledge of both time and energy, assuming that primary factors (spectra) are Gaussian-shaped with full-width at half-maximum equal to gamma camera energy resolution. 5D-GFA was validated in a simultaneous pre-/post-synaptic dual isotope dynamic phantom study where 99mTc and 123I activities were used to model early Parkinson disease studies. 5D-GFA was also applied to simultaneous perfusion/dopamine transporter (DAT) dynamic SPECT in rhesus monkeys. In the striatal phantom, 5D-GFA yielded significantly more accurate and precise estimates of both primary 99mTc (bias=6.4 % +/- 4.3 %) and 1231 (-1.7% +/- 6.9%) time activity curves (TAC) compared to conventional FADS (biases = 15.5% +/- 10.6% in 99mTc and 8.3% +/- 12.7% in 123I, p < 0.05). Our technique was also validated in two primate dynamic dual isotope perfusion/DAT transporter studies. Biases of 99mTc-HMPAO and 123I-DAT activity estimates with respect to estimates obtained in the presence of only one radionuclide (sequential imaging) were significantly lower with 5D-GFA (9.4% +/- 4.3% for 99mTc-HMPAO and 8.7% +/-4.1% for 123I-DAT) compared to biases greater than 15% for volumes of interest (VOI) over the reconstructed volumes (p < 0.05). 5D-GFA is a novel and promising approach in dynamic SPECT imaging that can also be used in other modalities. It allows accurate and precise dynamic analysis while compensating for Compton scatter and cross-talk.

Algorithms↗

Dose uncertainty due to aperture effects in dynamic fields.

Dosimetry of intensity modulated radiation therapy requires accurate modeling of the beamlets that comprise each treatment segment. Planning systems such as Varian Eclipse and Philips Pinnacle recommend measuring dose distributions and output factors for fields as small as possible, generally down to at least 2 x 2 cm2. Conventionally, we perform these measurements for regular fields, defined by the secondary collimators. In practice, it is the multileaf collimation system (MLC) that defines the intensity map and provides dynamic dose modulation in either a moving window or segmented step-and-shoot mode. For this review we have only considered the latter delivery mode. Using this method, we have studied aperture motion effects on the dynamic collimator scatter (S(c)), total scatter (S(c,p)), and phantom scatter (S(p)) factors for various combinations of collimator settings (4 x 4-14 x 40 cm2) and dynamically stepped leaf gaps (0.1 to 1.0 cm) in comparison with those for static field factors. For two different Varian linear accelerators, we found similar results in a systematic dependence of collimator scatter on gap width and collimator setting. As the gap increases from 0.1 to 1.0 cm the dynamic collimator scatter factors converge from a maximum difference of about 30% toward the static field values. At the same time, there is no measurable difference between dynamic field phantom scatter factors and those conventionally obtained for static fields. Second, we evaluated the two planning systems as to how well they account for collimator scatter by attempting to mimic the dynamic apertures used above by planning and measuring dose distributions to several small, cylindrical targets for a similar range of fixed collimator settings. We found that the ratio of measured-to-planned doses as a function of target size were similar to the measured, dynamic S(c) data for the Varian Eclipse planning system, indicating underestimation of dose for targets smaller than 1 cm diameter, but were close to unity for the Philips Pinnacle system, suggestive of the underlying differences in the dose calculation algorithms. We discuss the measurements and results and potential impact on the dosimetry of small clinical targets.

Air↗

Verification and implementation of dynamic wedge calculations in a treatment planning system based on a dose-to-energy-fluence formalism.

The use of dynamic movements on linear accelerators during irradiation has found a revised interest lately due to the integration of computers to control the accelerator. In this paper, dynamic wedge fields that are produced by moving one of the collimator blocks during irradiation are studied. Since these wedge fields differ from those of mechanical wedges, certain requirements are to be met on the treatment planning system. A pencil-beam-based treatment planning system that uses the resultant energy fluence distribution from the dynamic collimator movement has been extensively reviewed. In calculations, the system treats the dynamic collimated field as a single, modulated field that yields calculation times close to those for open beams. Details are given on the theoretical model used for the calculation of dynamically generated dose distributions. Measurements of depth doses, profiles, and output factors in dynamic wedge fields indicate that calculations accurately predict the outcome from dynamic wedges without any additional measurements other than those used for characterization of static open beams.

Biophysical Phenomena↗

High-rate conditioning pulse trains in cochlear implants: dynamic range measures with sinusoidal stimuli.

The addition of a continuous, unmodulated, high-rate pulse train to the electrical signals of cochlear implant recipients results in statistically significant increases in psychophysical dynamic range (41 out of 46 electrode pairs tested). The observed increases in dynamic range are thought to result from nerve conditioning by appropriate levels of high-rate pulse train. Five dynamic range profiles are characterized, defining the different responses of dynamic range observed with increasing levels of the conditioner. Four of the five profiles demonstrate increases in dynamic range, with three showing behavior consistent with stochastic resonance. One profile depicts evidence of adaptation in response to higher levels of the conditioner, with a recovery period lasting throughout the duration (on the scale of tens of minutes) of experimentation. Dynamic range profiles are shown to be similar across sinusoidal frequencies (202, 515, and 1031 Hz) but potentially different across electrode pairs (electrodes 1-2, 7-8, and 15-16). Correlation analysis does not reveal any predictors of optimal conditioner level or amount of dynamic range increase with the conditioner.

Adult↗

Effect of speaking rate and contrastive stress on formant dynamics and vowel perception.

Vowel formants play an important role in speech theories and applications; however, the same formant values measured for the steady-state part of a vowel can correspond to different vowel categories. Experimental evidence indicates that dynamic information can also contribute to vowel characterization. Hence, dynamically modeling formant transitions may lead to quantitatively testable predictions in vowel categorization. Because the articulatory strategy used to manage different speaking rates and contrastive stress may depend on speaker and situation, the parameter values of a dynamic formant model may vary with speaking rate and stress. In most experiments speaking rate is rarely controlled, only two or three rates are tested, and most corpora contain just a few repetitions of each item. As a consequence, the dependence of dynamic models on those factors is difficult to gauge. This article presents a study of 2300 [iai] or [i epsilon i] stimuli produced by two speakers at nine or ten speaking rates in a carrier sentence for two contrastive stress patterns. The corpus was perceptually evaluated by naive listeners. Formant frequencies were measured during the steady-state parts of the stimuli, and the formant transitions were dynamically and kinematically modeled. The results indicate that (1) the corpus was characterized by a contextual assimilation instead of a centralization effect; (2) dynamic or kinematic modeling was equivalent as far as the analysis of the model parameters was concerned; (3) the dependence of the model parameter estimates on speaking rate and stress suggests that the formant transitions were sharper for high speaking rate, but no consistent trend was found for contrastive stress; (4) the formant frequencies measured in the steady-state parts of the vowels were sufficient to explain the perceptual results while the dynamic parameters of the models were not.

Humans↗

Neural network based dynamic controllers for industrial robots.

The industrial robot's dynamic performance is frequently measured by positioning accuracy at high speeds and a good dynamic controller is essential that can accurately compute robot dynamics at a servo rate high enough to ensure system stability. A real-time dynamic controller for an industrial robot is developed here using neural networks. First, an efficient time-selectable hidden layer architecture has been developed based on system dynamics localized in time, which lends itself to real-time learning and control along with enhanced mapping accuracy. Second, the neural network architecture has also been specially tuned to accommodate servo dynamics. This not only facilitates the system design through reduced sensing requirements for the controller but also enhances the control performance over the control architecture neglecting servo dynamics. Experimental results demonstrate the controller's excellent learning and control performances compared with a conventional controller and thus has good potential for practical use in industrial robots.

Algorithms↗

Tracheobronchomalacia: comparison between end-expiratory and dynamic expiratory CT for evaluation of central airway collapse.

PURPOSE: To compare dynamic expiratory and end-expiratory computed tomography (CT) for depicting central airway collapse in patients with acquired tracheobronchomalacia (TBM). MATERIALS AND METHODS: Institutional review board approval was obtained, and informed consent was not needed. Retrospective review was performed of all patients with a CT diagnosis of TBM in a 10-month period (n = 34) who underwent evaluation of airway disease by means of three different sequences at multi-detector row CT: end inspiration, dynamic expiration, and end expiration (the latter was performed only at the levels of the aortic arch, carina, and bronchus intermedius). Fourteen patients (11 men, three women; age range, 19-79 years) who had comparable images obtained with all three sequences at any of these three levels were included in the study. The degree of airway collapse was measured by two thoracic radiologists in consensus by calculating the percentage change in the area of the airway between inspiratory and expiratory scanning. Statistical analysis was performed by using the paired t test. RESULTS: Dynamic expiratory CT elicited a significantly greater degree of airway collapse than end-expiratory CT at all three levels (P < .005). The mean percentages of airway collapse at each of the three levels were as follows: aortic arch, 53.9% with dynamic expiration versus 35.7% with end expiration (P = .0046); carina, 53.6% with dynamic expiration versus 30.9% with end expiration (P < .0001); and bronchus intermedius, 57.5% with dynamic expiration versus 28.6% with end expiration (P = .0022). CONCLUSION: Dynamic expiratory CT elicits a significantly greater degree of airway collapse than standard end-expiratory CT in patients with TBM.

Adult↗

Staging prostate cancer with dynamic contrast-enhanced endorectal MR imaging prior to radical prostatectomy: experienced versus less experienced readers.

PURPOSE: To prospectively determine the accuracy of experienced and less experienced readers in the interpretation of combined T2-weighted fast spin-echo (SE) magnetic resonance (MR) images and dynamic contrast material-enhanced MR images compared with T2-weighted fast SE alone, with respect to differentiation of stage T2 versus stage T3 prostate carcinoma, with histologic analysis serving as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained, and 124 consecutive men (age range, 42-74 years; median age, 63 years) with biopsy-proved prostate cancer underwent MR imaging and were candidates for radical prostatectomy. T2-weighted fast SE MR images and multisection dynamic contrast-enhanced MR images with a 2-second time resolution for the whole prostate were obtained. The T2-weighted and fused color-coded parametric dynamic contrast-enhanced MR images with T2-weighted images were evaluated prospectively and scored with regard to local extent by one experienced reader and evaluated retrospectively by two less experienced readers working in consensus by using a five-point scale; images with a score greater than or equal to four were considered indicative of T3 disease. Results were correlated with whole-mount section histopathologic findings, and receiver operating characteristics analysis was performed. RESULTS: Twenty-five patients were excluded because of positive findings in the lymph nodes (n = 16), preoperative biopsy-proved seminal vesicle invasion (n = 5), and an absent dynamic dataset (n = 4). Ninety-nine patients were included in this study. The overall sensitivity, specificity, and accuracy of MR staging performance in prostate cancer with dynamic contrast-enhanced MR imaging was 69% (24 of 35 patients), 97% (62 of 64 patients), and 87% (86 of 99 patients), respectively, for the experienced reader. This difference was not significant (P = .48) when results were compared with results from the T2-weighted images. Staging performance for the less experienced readers with parametric dynamic contrast-enhanced MR imaging, however, resulted in significant improvement of the area under the receiver operating characteristics curve (A(z)) compared with T2-weighted MR imaging alone (A(z) = .66 and .82, respectively; P = .01). CONCLUSION: The use of multisection dynamic contrast-enhanced MR imaging in staging prostate cancer showed significant improvement in staging performance for the less experienced readers but had no benefit for the experienced reader.

Adult↗

Carcinoma of the cervix: dynamic MR imaging.

Dynamic magnetic resonance (MR) imaging was performed to evaluate eight normal uteri and 29 cervical carcinomas. After rapid injection of gadopentetate dimeglumine, dynamic images were obtained every 30 seconds with the spin-echo (SE) technique in the sagittal plane or the fast low-angle shot (FLASH) technique in the axial plane. In the normal uterus, initial slight enhancement of the junction between endometrium and myometrium was followed by enhancement of the uterine myometrium. Cervical carcinoma was readily distinguished from the cervical stroma and myometrium in the early dynamic phase (30-60 seconds). Tumor-cervix contrast in the early dynamic phase was significantly more marked with the dynamic SE technique than with T2-weighted or contrast material-enhanced T1-weighted imaging (P less than .01). For the evaluation of parametrial invasion, the dynamic FLASH study showed better contrast than did T2-weighted images. Among 18 patients who underwent surgery, accurate assessment of the degree of stromal invasion and tumor size was possible with dynamic MR images in 14 patients (78%), T2-weighted images in 11 (61%), and postcontrast T1-weighted images in seven (39%).

Carcinoma, Squamous Cell↗

Pancreatic ductal adenocarcinoma: preoperative assessment with helical CT versus dynamic MR imaging.

PURPOSE: To compare helical computed tomography (CT) and dynamic, magnetic resonance (MR) imaging in the evaluation of pancreatic ductal adenocarcinoma. MATERIALS AND METHODS: Dynamic MR images obtained with breath holding, 256 phase- and 512 frequency-encoding steps, 5-mm section thickness, phased-array multicoil, and double-dose gadolinium were available from 21 patients. Dynamic MR images were retrospectively compared with helical CT images in the evaluation of tumor detection, local tumor extension, and vascular involvement. RESULTS: Tumors were detected on dynamic MR images of 19 of 21 (90%) patients and on helical CT scans of 16 (76%) patients. Dynamic MR imaging had equal or better sensitivity, accuracy, and agreement of tumor grade than did helical CT in the comparison of imaging findings and histopathologic findings. Dynamic MR imaging also had equal or better specificity than had helical CT in determination of local tumor extension and vascular involvement, except in the factors of duodenal invasion and portal venous system involvement. However, there was no statistically significant difference among any of these measurements. CONCLUSION: Dynamic MR imaging may be better than helical CT in the preoperative detection and evaluation of local tumor extension and of vascular involvement of pancreatic ductal adenocarcinomas.

Adult↗

Skeletal muscle blood flow and flow heterogeneity during dynamic and isometric exercise in humans.

The effects of dynamic and intermittent isometric knee extension exercises on skeletal muscle blood flow and flow heterogeneity were studied in seven healthy endurance-trained men. Regional muscle blood flow was measured using positron emission tomography (PET) and an [(15)O]H(2)O tracer, and electromyographic (EMG) activity was recorded in the quadriceps femoris (QF) muscle during submaximal intermittent isometric and dynamic exercises. QF blood flow was 61% (P = 0.002) higher during dynamic exercise. Interestingly, flow heterogeneity was 13% (P = 0.024) lower during dynamic compared with intermittent isometric exercise. EMG activity was significantly higher (P < 0.001) during dynamic exercise, and the change in EMG activity from isometric to dynamic exercise was tightly related to the change in blood flow in the vastus lateralis muscle (r = 0.98, P < 0.001) but not in the rectus femoris muscle (r = -0.09, P = 0.942). In conclusion, dynamic exercise causes higher and less heterogeneous blood flow than intermittent isometric exercise at the same exercise intensity. These responses are, at least partly, related to the increased EMG activity.

Adult↗

Complex AV nodal dynamics during ventricular-triggered atrial pacing in humans.

In vitro experiments have shown that the complexity of atrioventricular nodal (AVN) conduction dynamics increases with heart rate. Although complex AVN dynamics (e.g., alternans) have been observed clinically, human AVN dynamics during rapid pacing have not been systematically investigated. We studied such dynamics during ventricular-triggered atrial pacing in 37 patients with normal AVN function (18 patients with dual AVN pathway physiology and 19 patients without). Alternans, which always resulted from single pathway conduction, occurred in 18 patients. In 16 patients (3 of whom also had alternans), quasisinusoidal AVN conduction oscillations occurred (mean frequency 0.02 Hz); such oscillations have not been previously reported. There were no significant differences in the dynamics for patients with or without dual AVN pathways. To illuminate the governing dynamic mechanism, a second atrial pacing trial was performed on 12 patients after autonomic blockade. Blockade facilitated alternans but inhibited oscillations. This study suggests that rapid AVN excitation in vivo can lead to autonomically mediated AVN conduction oscillations or single pathway alternans that are a function of inherent nonlinear dynamic AVN tissue properties.

Atrioventricular Node↗

Effects of calcium channel blockers on "dynamic" and "steady-state step" renal autoregulation.

Renal autoregulation (AR) mechanisms provide the primary protection against transmission of systemic pressures and hypertensive renal damage. However, the relative merits of the "step" change vs. "dynamic" methods for the assessment of AR capacity remain controversial. The effects of 48-72 h of orally administered amlodipine (L-type) and mibefradil (T-type) calcium channel blockers (CCBs) on step and dynamic AR in Sprague-Dawley rats were compared. Both CCBs significantly impaired "steady-state step" AR (autoregulatory indexes = approximately 0.5 vs. approximately 0.1 in controls, P < 0.05; n = 9-10/group). By contrast, dynamic AR compensation in separate conscious rats (n = 12) was not significantly altered by either amlodipine (n = 10) or mibefradil (n = 6; fractional gain in admittance approximately 0.4-0.5 in all groups at frequencies in the range of 0.0025-0.025 Hz). However, both CCBs tended to attenuate the myogenic resonance peak along with shifting it to a significantly slower frequency (P < 0.001) during dynamic AR, but no consistent effects were observed on the tubuloglomerular feedback resonance peak. While the reasons for the insensitivity of dynamic vs. steady-state step AR capacity estimates to CCBs remain to be established, the present data indicate that dynamic AR methods may have a limited utility for assessing AR capacity but may provide potentially important insights into the operational characteristics of AR control mechanisms. A strong correlation was also observed between the average conductance and the admittance gain at the heart beat frequency (r = 0.77, P < 0.001), suggesting that such parameters may provide additional and possibly more meaningful indexes of BP transmission in conscious animals during dynamic AR.

Amlodipine↗

Influence of body CO2 stores on ventilatory dynamics during exercise.

Pulmonary CO2 flow (the product of cardiac output and mixed venous CO2 content) is purported to be an important determinant of ventilatory dynamics in moderate exercise. Depletion of body CO2 stores prior to exercise should thus slow these dynamics. We investigated, therefore, the effects of reducing the CO2 stores by controlled volitional hyperventilation on cardiorespiratory and gas exchange response dynamics to 100 W cycling in six healthy adults. The control responses of ventilation (VE), CO2 output (VCO2), O2 uptake (VO2), and heart rate were comprised of an abrupt increase at exercise onset, followed by a slower rise to the new steady state (t1/2 = 48, 43, 31, and 33 s, respectively). Following volitional hyperventilation (9 min, PETCO2 = 25 Torr), the steady-state exercise responses were unchanged. However, VE and VCO2 dynamics were slowed considerably (t1/2 = 76, 71 s) as PETCO2 rose to achieve the control exercise value. VO2 dynamics were slowed only slightly (t1/2 = 39 s), and heart rate dynamics were unaffected. We conclude that pulmonary CO2 flow provides a significant stimulus to the dynamics of the exercise hyperpnea in man.

Carbon Dioxide↗

Central representation of dynamics when manipulating handheld objects.

To explore the neural mechanisms related to representation of the manipulation dynamics of objects, we performed whole-brain fMRI while subjects balanced an object in stable and highly unstable states and while they balanced a rigid object and a flexible object in the same unstable state, in all cases without vision. In this way, we varied the extent to which an internal model of the manipulation dynamics was required in the moment-to-moment control of the object's orientation. We hypothesized that activity in primary motor cortex would reflect the amount of muscle activation under each condition. In contrast, we hypothesized that cerebellar activity would be more strongly related to the stability and complexity of the manipulation dynamics because the cerebellum has been implicated in internal model-based control. As hypothesized, the dynamics-related activation of the cerebellum was quite different from that of the primary motor cortex. Changes in cerebellar activity were much greater than would have been predicted from differences in muscle activation when the stability and complexity of the manipulation dynamics were contrasted. On the other hand, the activity of the primary motor cortex more closely resembled the mean motor output necessary to execute the task. We also discovered a small region near the anterior edge of the ipsilateral (right) inferior parietal lobule where activity was modulated with the complexity of the manipulation dynamics. We suggest that this is related to imagining the location and motion of an object with complex manipulation dynamics.

Brain Mapping↗