Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radionuclide Generators”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

An in vitro gallium-67 lung index for the evaluation of sarcoidosis.

In the evaluation of the active alveolitis of pulmonary sarcoidosis, both the proportional lymphocyte count obtained by bronchoalveolar lavage and state of activation of the alveolar macrophage by gallium scanning are required. We injected 6 mCi (200 MBq) of 67Ga intravenously on 24 occasions in 13 patients with biopsy-proved sarcoidosis. Forty-eight hours later, patients were scanned with a rectilinear scanner and the generated scintigrams were evaluated using the NIH index. Seventy-two hours after injection, bronchoalveolar lavage was performed, and venous blood was sampled. The harvested lavage fluid was analyzed for absolute and proportional cell counts, and radioactivity was measured in blood and BAL fluid. An in vitro 67Ga index was generated and expressed as counts/100,000 alveolar macrophages/ml blood (mean, 0.0146 +/- 0.0087 SD). There was a significant relationship between the in vitro index and proportional lymphocyte BAL counts (r = 0.79; p less than 0.002) that was comparable to that obtained using the NIH index (r = 0.74; p less than 0.005). These data suggest that the in vitro index might offer a more objective assessment of 67Ga uptake by the lung, but this would require validation against clinical parameters in a prospective study.

Adult↗

The 15O steady-state method: correction for variation in arterial concentration.

One of the factors limiting the accuracy of the 15O steady-state method for the measurement of regional cerebral blood flow and oxygen metabolism is the requirement that a constant arterial blood concentration be maintained over long periods. A new method has been developed to correct for the variation of the arterial concentration in the C15O2 and 15O2 steady-state inhalation technique. The time course of the arterial activity is obtained by multiple sampling over the study period. The same 15O model as is used in the steady-state method is employed but is solved without assuming equilibrium. Look-up tables are generated to relate flow and oxygen extraction fraction to tissue activity, and from them the regional parameters are estimated. Theory and simulation studies suggest that substantial improvement in accuracy can be obtained with no increase in statistical error. The validity of the method was checked experimentally by making repeated measurements in the same subject after perturbing the gas delivery. The conventional steady-state method showed significantly larger deviations in repeat measurement than did the new method. Thus, it is concluded that the proposed method is superior.

Adult↗

Blue versus hot: learning the techniques with dye and isotopes.

Intraoperative lymphatic mapping and sentinel node (SN) biopsy has generated a tremendous amount of interest in the field of surgical oncology since its introduction for patients with early-stage melanoma. The SN concept has been applied recently to many solid tumors, including melanoma, breast cancer, thyroid cancer, gynecological malignancies, and colorectal cancers. Although the concept of intraoperative lymphatic mapping and SN biopsy has been validated in multiple single-institution studies as well as multicenter trials, there is still much discussion as to which mapping technique is easier to learn. This article focuses on the technical aspects of SN mapping in breast cancer and reviews the most recent data to try to determine which technique is superior.

Breast Neoplasms↗

Technetium 99m pertechnetate measurement of renal blood flow distribution.

The accuracy of measuring anatomical blood flow using the rising slopes of first-pass time-activity curves were studied in six isolated dog kidneys. In each case, the canine kidney was placed on an open-circuit in vitro perfusion apparatus, which included an in-line flow meter and an in-line variable resistance for adjusting the flow rate. Time-activity curves from images acquired at 2-second intervals were generated for each kidney following injection of 4 mCi of 99mTc pertechnetate into the perfusate solution for each flow rate condition studied. The flow rate was calculated from the average slope of the ascending segment, initial rise to peak, of the time-activity curves. Excellent agreement was found between the radioactive tracer and established flow meter measurements (r = 0.995). With the availability of mobile gamma camera/computer systems, this technique could easily be utilized in evaluating perfusion function of transplant kidneys prior to surgery. Also, this technique can be useful in monitoring the renal anatomical distribution of blood flow in postsurgical patients.

Animals↗

Regional time-based functional imaging of hepatocyte function.

Hepatocyte function was analyzed following the injection of 5 mCi of Tc-99m disofenin by the computer generation of three kinds of functional images designed to portray regional rates of hepatic uptake. Nineteen patients were analyzed, of whom eight had no overt liver disease, five had active hepatitis, five had cirrhosis, and one had acute cholecystitis. Functional images were graded according to lack of regional homogeneity of accumulation. Uptake kinetics were found to be significantly more homogeneous in normal subjects, becoming increasingly heterogeneous in hepatitis and cirrhosis patients, respectively. Thus functional imaging may provide a tool for the quantitative analysis of parenchymal disruption in liver disease.

Adult↗

[The scintigraphic effect of extracorporeal lithotripsy: prospective series of 25 cases].

25 patients with non complicated renal stones were treated by extracorporeal shockwave lithotripsy (ESWL) using Sonolith 3000 an electrohydraulic generator type. They were evaluated before, 15 days and 3 months after ESWL by renal scintigraphy, using for 15 of them technetium -99m dimer captosuccinic acid and technetium -99m-diethylene-triamine acetate for the last 10. This follow up scintigraphic study shows no reduction of glomerular filtration rate after ESWL but some focal parenchymal lesions. Very few of these lesions persist at 3 months. These parenchymal damages seem to be less frequent and less persistent than with piezo-electric lithotripter.

Adult↗

Fatty acid myocardial imaging using 123I-beta-methyl-iodophenyl pentadecanoic acid (BMIPP): comparison of myocardial perfusion and fatty acid utilization in canine myocardial infarction (occlusion and reperfusion model).

To evaluate the relationship between myocardial perfusion and fatty acid metabolism in canine myocardial infarction, 16 dogs were studied using thallium and 123I-beta-methyl-iodophenyl pentadecanoic acid (BMIPP). Eight dogs (group A) had left anterior coronary arterial occlusion (6 h ligation), 6 dogs (group B) had reperfusion (3 h ligation and 1 h reperfusion) and 2 dogs served as the normal control. Myocardial imaging with BMIPP was excellent, owing to its higher uptake and longer retention in myocardium and rapid blood disappearance in addition to diminished liver and lung uptake. The mean half time value which was generated from the BMIPP myocardial washout curve, was significantly larger in the reperfused myocardium. The gamma camera imaging showed uncoupling of BMIPP and thallium (BMIPP uptake greater than thallium uptake) in five dogs in group B. On the other hand, all dogs in group A had a persistent defect in BMIPP and thallium uptake. Our findings indicate that the combination of BMIPP and thallium for myocardial imaging supply different information about the zone of infarction and ischemia, which may be useful for the assessment of myocardial viability.

Animals↗

Prediction of therapy response to interferon-alpha in chronic viral hepatitis-B by liver and hepatobiliary scintigraphy.

Interferon (IFN) provides effective treatment in some patients with chronic hepatitis. The clarification of factors predictive of therapy response would be helpful in identifying patients who would benefit from treatment. In this study, we evaluated the potential utility of Tc-99m sulfur colloid liver/spleen and Tc-99m-disofenin hepatobiliary scintigraphy to predict therapy response to IFN in patientswith chronic active hepatitis. The study group consisted of ten patients with chronic viral hepatitis B who were treated with 4.5 units of interferon alpha for 12 months. Prior to the start of the therapy, sulfur colloid scintigraphy was obtained by which the liver/spleen ratios were derived. Hepatobiliary scintigraphy was performed on a separate day and time-activity curves were generated from regions of interest drawn over the liver, heart and gall-bladder. The index of blood and liver clearance time was calculated. Histological grading and laboratory values were obtained for clinical correlation. Responders (n = 6) to IFN were defined as those who improved clinically with normalized transaminase levels and had HBeAg seroconversion. On SC scintigraphy, the liver/spleen ratio of non-responders was significantly lower than responders (median values: 0.69 vs. 1.16, p = 0.01) but on hepatobiliary scintigraphy no statistically significant parameters were found to predict response to interferon therapy.

Adult↗

[Computed tomography following extracorporeal shockwave lithotripsy of the kidneys. III. A prospective CT study of 105 patients and a 3-year follow-up of 23 patients using CT and 99mTc-MAG3 clearance].

In 105 patients CT studies were done prospectively after renal ESWL with a second generation lithotripter. 33 (31%) of the patients had renal oedema (n = 8), renal (n = 20) or extrarenal (n = 31) bleeding. Three of the 23 patients who had a three year follow-up had chronic renal changes, 10 had renal stones. As blunt renal trauma can be the cause of renal hypertension a longterm follow-up is necessary in ESWL patients, particularly if there was renal bleeding after treatment. Further studies are needed to determine the exact risk of renal hypertension after ESWL.

Adult↗

Sedimentation rates measurements in former channels of the upper Rhône river using Chernobyl 137Cs and 134Cs as tracers.

Former river channels are aquatic ecosystems with a different geomorphology generated by fluvial dynamics more or less linked to the main channel. They present different ecological successions to become terrestrial ecosystems and are thus supposed to have different sedimentation rates. The aim of this paper is to assess this sedimentation rate using radioactive tracer methodology commonly used in lake studies. Chernobyl impacts, expressed in 137Cs concentration and 137Cs/134Cs ratio, were determined in sediment cores. Sites (21) were sampled in the alluvial plain of the Upper Rhône River from 1989 to 1994. The contamination presented a high spatial heterogeneity. The maximum values encountered by site ranged between 34 and 541 Bq/kg of dry matter. The method generally gave good core profiles. Sedimentation rate ranged between 0.14 and 0.70 cm/year for the former meanders and between 0.14 and 2.86 cm/year for the braided channels. The sediment accumulation rates ranged from 0.03 to 0.25 g/cm2 per year and 0.03 to 2.26 g/cm2 per year, respectively. These values are similar to those found for Lake Geneva. The importance of the former channels in relation to the main channel is enhanced by the higher contamination and radionuclides retention. The sediment accumulation rate is related to the organic carbon content in the sediment. A comparison between two former channels with different productivity showed that the the allogenous driven system presents a high organic sediment accumulation rate with a low organic content in the sediment and inversely, a low organic sediment accumulation rate with a high organic carbon content was found for the autogenous drive system.

Carbon↗

Optimum timing for image-based dose evaluation of 125I and 103PD prostate seed implants.

PURPOSE/OBJECTIVE: Image-based dose evaluation of permanent brachytherapy implants for prostate cancer is important for optimal patient management after implantation. Because of edema caused by the surgical procedure in the implantation, if the dose evaluation is based on the images obtained too early after implantation, dose coverage will usually be underestimated. Conversely, if the images are obtained too late, the dose coverage will be overestimated. This study uses a biomathematical model to simulate edema and its resolution on 29 patients, so that the optimum time to obtain image scans and perform dose evaluation can be investigated and estimated. METHODS AND MATERIALS: Edema of a prostate and its resolution has been shown to follow an exponential function V(t) = V(0)(1 + deltaV[e-0.693t/Te - 1]) where deltaV is the initial relative increase in the prostate volume due to edema (and is related to edema magnitude), and Te (edema half-life) is the time for the edema to decrease by half in volume. In this study, edema was simulated by increasing the volume of preimplant prostate (obtained from ultrasound volume study) to a given magnitude of edema. Similarly, the locations of planned seeds were changed to their corresponding locations in the edematous prostate proportionally. The edema was then allowed to resolve according to the exponential function. The correct dose distribution was calculated by taking into account the dynamic variations of the prostate volume, seed locations, and source strengths with respect to time. Dose volume histograms (DVHs) were then generated from this dose distribution. The conventional postimplant DVHs, which assume the prostate volume and seed locations are as in the image scans and constant in time, were also calculated based on the simulated image scans for various days postimplantation. The conventional DVHs of prostate on various days after implantation were compared to the DVH calculated assuming dynamic conditions. The optimum timing for conventional postimplant dose evaluation was identified as the time at which a minimum difference between the conventional DVH and the dynamic model DVH was achieved. The analysis was done on 29 prostate seed implant patients for both 125I and 103Pd. The edema magnitude was assumed to be 30%, 40%, 50%, 75%, and 100% of original prostate volume, and the half-life of edema was assumed to be 4, 7, 10, 15, 20, and 25 days. In this study, the original volume of prostate varied from 17 cm3 to 91 cm3, and number of seeds in the implants varied from 57 to 119. RESULTS: The optimum timing was mainly dependent on the half-lives of edema and radionuclides, and varied slightly with edema magnitude, prostate volume, and number of seeds. It can be expressed as a function of edema half-life in the form of C0 + C1exp(-C2Te). However, if the dose evaluation was performed based on the image scans taken too early or too late, the error became larger, as the edema magnitude was larger. By averaging all 29 patients and various edemas, it was found that for 125I seed implants, if the postimplant dose evaluation is performed based on image scans taken between 5 and 9 weeks, the average error will be less than 5%, with a maximum possible error less than 10% in 80% coverage dose; for 103Pd seed implants, if the postimplant dose evaluation is performed based on image scans taken between 2 and 4 weeks, the average error will be less than 5%, with a maximum error less than 15% in 80% coverage dose. Because of edema, a conventional preimplant plan also overestimates dose coverage of prostate. On the average, a standard preimplant planning overestimates dose coverage by about 6% for 125I implants and 14% for 103Pd implants in our study. CONCLUSION: Based on the dynamic model, the optimum timing of image scans for postimplant dose evaluation of prostate seed implantation is 7 weeks postimplantation for 125I implants and about 3 weeks for 103Pd implants. (ABSTRACT TRUNCATED)

Brachytherapy↗

Generation of a microaerosol suitable for deposition in the peripheral airways.

A method is described for the production of a dry submicronic aerosol. A wet aerosol is first produced in a common jet aerosol apparatus, modified to retain particles larger than 2 micrometers. The aerosol is then dried by heating to 70 degrees C in an evaporation tube. The dry particles are mainly smaller than 0.5 micrometer. At inhalation the temperature drops below 40 degrees C and the dew point is reached so that water vapour condenses on the particles. About 95% of the particles were deposited past the large bronchi and about 87% were retained in the alveoli. The new technique renders very satisfactory ventilation scintigraphies as proven by experience from more than 200 subjects. It may also prove useful for depositing drug aerosols in the peripheral airways.

Aerosols↗

[Dose estimation of Tc-99m-DTPA-galactosyl-human serum albumin (Tc-99m-GSA) in the blood with nonlinear regression method].

Tc-99m-DTPA-galactosyl-human serum albumin (Tc-99m-GSA) was applied as an agent for receptor-binding hepatic scintigraphy. A single dose of 3-10 mg/185 MBq (5 mCi) Tc-99m-GSA per body was administered in four healthy volunteers and three patients. Time-activity curves for 60 (40) min after injection were obtained from the regions-of-interest over the heart and lung (back-ground). Exponential regression curve was generated from the heart curve during 2-60 (40) min after background subtraction with nonlinear least squares method. Regression curve was well fitted to the heart curve and a significant correlation coefficient of 0.997 +/- 0.003 was obtained between these two curves. Absolute dose of GSA in the blood was decided on the assumption that extrapolated value of regression curve at time 0 represented the total injected dose. The absolute dose differences between sample blood and regression curve were 1.4-4.3% (mean). Nonlinear regression analysis is useful for estimating quantitative dose of GSA in blood without any blood samples.

Adult↗

The metabolism of 15-p-[123I]-iodophenylpentadecanoic acid in a surgically induced canine model of regional ischemia.

The purpose of this study was to examine the longitudinal effect of gradual coronary occlusion on regional myocardial metabolism of 15-p-123I-iodophenylpentadecanoic acid [( 123I]IPPA). Adult dogs were imaged using [123I]IPPA and planar gamma imaging. A thoracotomy was performed and an ameroid constrictor of appropriate size permanently positioned on the left anterior descending coronary artery. The dogs were imaged after injection of 3-5 mCi [123I]IPPA at various times over a 2-week period. With imaging on days 7 and 14, the dogs were paced at a rate of 185. Time-activity curves were generated and t1/2 values calculated using monoexponential curve fitting. Results indicate a significant increase in t1/2 between control and 14 days after surgery in the apical wall (29 +/- 7 to 53 +/- 18 min; P less than 0.05). Although there was also an increased t1/2 in the lateral wall, this was not significant (27 +/- 8 to 78 +/- 99 min; P greater than 0.05). There was no significant change in t1/2 in the septal wall (27 +/- 9 to 33 +/- 8 min; P greater than 0.05). We conclude that [123I]IPPA is a useful indicator of developing myocardial ischemia.

Animals↗

Computerized study with 201T1 of the cold thyroid node.

Because of its physical and potassium-metabolic characteristics 201T1 is more suitable than 131Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behavior for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 microCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201T1 uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201T1 kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular disappearance-index.

Adenocarcinoma↗

Count-rate variations with orientation of camera detector.

Variations of count rate with orientation of the detector were investigated. Scaled difference images (SDI) were generated from pairs of arrays acquired at different detector orientations. The hypothesis tested was that any variations could be totally explained by random disintegration noise. We accepted or rejected this hypothesis according to the statistical significance of the difference between the measured and theoretical means and variances of the SDIs. When two images acquired at the same angle were compared, no significant differences were noted. Differences were significant between most pairs of images obtained at different angular orientations. Cameras with inadequate magnetic shielding were more sensitive to orientation effects than those with proper magnetic shielding. The mode of variation strongly suggests an interaction with a magnetic field.

Magnetics↗

Experimental biodistribution studies of 99mTc-recombinant human serum albumin (rHSA): a new generation of radiopharmaceutical.

Recombinant human serum albumin (rHSA) produced by cultured fermentation has been prepared in the form of microcapsules nominally 3-5 microns in diameter and radiolabelled with technetium-99m following reduction with stannous chloride. Radiochemical purity was assessed by chromatography on instant thin-layer chromatography and found to be greater than 90%. No evidence of aggregation was seen by microscopic examination. Imaging biodistribution studies in New Zealand white rabbits demonstrated targeting to the liver or lung, respectively, depending upon the size and surfactant properties of the microcapsules. This communication is the first to show scintigraphic studies using 99mTc-labelled rHSA with the potential for lung, liver and cardiovascular imaging and demonstrates that recombinant DNA technology offers an important new source of materials suitable for use as radiopharmaceuticals without the need for pooled human blood products.

Animals↗

Radioaerosol mucociliary clearance of tracheobronchial tree in normal subjects and in patients with respiratory diseases.

The rate of mucociliary clearance in the tracheobronchial tree was studied both in patients and controls using radioisotopic techniques. The radioisotope is deposited in the larger airways and its rate of movement is measured as it is being transported up the trachea due to mucociliary activity. The BARC aerosol generation system was modified and used for this purpose. One hour study was acquired on a computerised gamma camera in each case. The rate of movement of the bolus of radioactivity was calculated by measuring the distance travelled in a known period of time. The mean velocity of transport was 9.0mm/min in normal subjects. In patients variable speed of transportation was obtained ranging from absolutely no movement to near normal speeds. Different patterns of transport were observed including linear, spiral, static and regurgitative. It was concluded that this simple non-invasive technique can be used for in vivo monitoring of mucociliary tracheal activity.

Adult↗