Cerenkov radiation as a UV and visible light source for time-resolved fluorescence.

We demonstrate the first use of Cerenkov radiation for the measurement of fluorescence lifetimes. Relativistic beta particles from the nuclear decay of 90 Sr and 90Y generate a spectral continuum in a quartz waveguide. Light flashes of < 100-ps duration are delivered simultaneously to a sample cell and a reference photomultiplier. A simple, digitally based cross-correlation signal processor allows extraction of the sample fluorescence decay kinetics without distortions which can result from the random excitation pulse sequence. We characterize both the pulse duration and the pulse intensity of the light that is emitted from the waveguide. Although the excitation intensity is very weak, we demonstrate that accurate lifetime measurements are possible with only a few hundred seconds of integration time. Tests on a variety of compounds illustrate the utility of the light source throughout the UV and blue regions of the spectrum. We also discuss future design improvements and potential applications of this new approach to time-resolved fluorescence.

Fluorescence↗

Three-dimensional phase-encoded chemical shift MRI in the presence of inhomogeneous fields.

A pulse sequence consisting of an excitation pulse and two adiabatic full-passage pulses with scaled relative peak amplitudes is combined with phase encoding to recover chemical shift information within 3D images in a 1D inhomogeneous static magnetic field with a matched rf field gradient. The results are discussed in the context of ex situ magnetic resonance and imaging. The future directions of our research in implementing the ex situ technique in a real one-sided system are also discussed.

Journal Article↗

Hepatic lesion detection after superparamagnetic iron oxide enhancement: comparison of five T2-weighted sequences at 1.0 T by using alternative-free response receiver operating characteristic analysis.

PURPOSE: To compare the accuracy of five T2-weighted sequences in the detection of liver lesion at magnetic resonance (MR) imaging after superparamagnetic iron oxide (SPIO) enhancement. MATERIALS AND METHODS: Forty-nine candidates for hepatic resection with known coloretal metastases were examined. Before SPIO enhancement, fast spin-echo (SE) images were obtained. After enhancement, the same fast SE sequence and long; TR/short TE, short TE, long TR/TE, and T2-weighted fast low-angle shot (FLASH) sequences were used. All images were viewed independently by four observers who were blinded to the results of the other imaging sequences, the results of the other observers, and the findings at surgery and histopathologic examination. Four weeks after the initial reading, the combined long TR/short TE and long TR/TE dual-echo images were also viewed as an additional set. The alternative free response receiver operating characteristic (ROC) method was used to analyze the results, which were correlated with findings at surgery, intraoperative ultrasonography, and histopathologic examination. RESULTS: Irrespective of lesion size, the accuracy of all sequences after enhancement was significantly greater than that of the nonenhanced fast SE sequence (P < .01). Dual-echo and FLASH sequences were significantly more accurate than the enhanced fast SE sequence (P < .03 or P < .02, respectively). For all lesions, lesions smaller than 1 cm, and lesions 1 cm or larger, mean accuracies were as follows: dual-echo, 0.75, 0.54, and 0.93; FLASH, 0.75, 0.54, and 0.95; and enhanced fast SE, 0.72, 0.49, and 0.92. CONCLUSION: At 1.0 T, dual-echo and FLASH sequences are the most accurate pulse sequences after SPIO enhancement.

Aged↗

The detection of bone marrow involvement by lymphoma using magnetic resonance imaging.

We used magnetic resonance (MR) to image the bone marrow of 31 patients with lymphoma. Images were obtained of the femoral, pelvic, and vertebral marrow with a 0.15 tesla imaging system using a T1-weighted spin echo sequence (TR600/TE 40). With this pulse sequence, normal marrow produces a high intensity signal that reflects the presence of marrow fat (short T1 relaxation time). We previously reported MR imaging of patients with leukemia in relapse and found a diffusely and symmetrically decreased marrow signal intensity due to the replacement of normal marrow fat by cellular material with a long T1. Unlike leukemia, patients with lymphomatous marrow involvement often had patchy, often discrete, areas of low signal intensity, representing focal marrow infiltration. Five of six patients in this study with lymphoma detected by histologic examination also had marrow lesions seen on MR. An additional four patients had marrow lesions detected by MR that were not detected on initial marrow biopsies; two of these had marrow involvement proven on subsequent biopsies, one had disease isolated to the vertebrae that was never pathologically documented, and one had progression of disease in the marrow documented by MR without biopsy confirmation. These results indicate that marrow involvement with lymphoma can be detected by MR imaging and that MR can complement bone marrow biopsy.

Adult↗

Comparison of MR sequences in quantifying in vitro cartilage degeneration in osteoarthritis of the knee.

Magnetic resonance imaging of amputated human knees was performed to determine optimal sequences for depicting articular cartilage. 24 knees were examined with eight different sequences in a 1.0 T imager. Each cartilage lesion was graded from 1 to 4 (Outerbridge staging system). The results of each sequence were compared with the macroscopic findings and statistically tested against each other. The FLASH sequence (TR = 50 ms) with combination of flip angle of 40 degrees and echo time of 10 ms and the FISP sequence (TR = 40 ms) with combination of flip angle of 40 degrees and echo time of 11 ms were best for depicting cartilage structure and internal detail. There was no significant difference between fat-saturated three-dimensional FLASH (FS-3D-FLASH) and FS-3D-FISP (p = 0.05). These FS-3D sequences were significantly better than sequences without fat saturation (p = 0.05). There was no significant difference between magnetization transfer (MT) 3D-FLASH, MT-3D-FISP and 3D-FISP. All 3D sequences showed significantly (p = 0.05) better results than spin echo or fast spin echo sequences. The T1 weighted SE pulse sequence was significantly (p = 0.005) better than the T2 weighted TSE sequence. Fast T2 weighted spin echo was not suitable for early and accurate detection of cartilage lesions.

Aged↗

[Diagnostic evaluation of magnetic resonance urography in urinary tract dilatation and obstruction].

OBJECTIVE: To evaluate the diagnostic value of magnetic resonance urography (MRU). METHODS: Two hundred and one patients were examined, 92 patients with urinary tract dilatation using a modified, heavily T2-weighted fast spin-echo pulse sequence and fat-suppression pulse aid. Postprocedure processing was performed with a maximum-intensity-projection (MIP) algorithm. RESULTS: In the 92 patients with urinary tract dilatation, 86 had obstructive urinary tract dilatation 6 non-obstructive urinary tract dilatation. In the 86 patients, 14 had ureteral carcinoma, 19 calculus, and 13 benign stricture, 23 congenital ureteral stricture/or with anomalies, 7 ureteral obstructive caused by extrinsic pelvis disease, and 10 bladder carcinoma involved ureter. In the 6 patients, 5 had nervous bladder. MR urography provided the high-resolution image of the urinary tract and determined the presence of obstruction. CONCLUSION: MR urography is a reliable noninvasive method for depicting the urinary tract.

Adolescent↗

[MR urography: technique and clinical application in patients with kidney transplantation].

OBJECTIVE: To assess the value of magnetic resonance urography (MRU) for the noninvasive postoperative evaluation of renal transplants. METHODS: 28 cases of renal transplantation were examined with a modified, heavily T2-weighted fast apin-echo pulse sequence and fat-suppression pulse aid. Post-procedure processing was performed with a maximal-projection (MIP) algorithm. RESULTS: 28 patients were studied. MRU revealed abnormal finding in 9 patients: mild dilatation of the renal pelvis without any urodynamic relevant obstruction (2), moderate dilatation of the renal pelvis (3), acute rejection (3), and ATN (1). Ureteral stenosis was diagnosed in 1 patients and treated surgically. CONCLUSIONS: MRU is an alternative to conventional urinary tract images techniques. It requires no radiation or iodinated contrast material. It is reliable and noninvasive in depicting the urinary tract. MRU can be used as a noninvasive technique for assessment of renal transplantation in cases suspicious of complication in the excretory system.

Adult↗

Detection of hepatocellular carcinoma: comparison of dynamic MR imaging with dynamic double arterial phase helical CT.

OBJECTIVE: Three-dimensional (3D) Fourier transformation-enhanced fast gradient-echo sequences with a special spectral inversion recovery pulse and fat suppression developed for abdominal imaging, including MR angiography, can show enhanced areas clearly. The purpose of this study was to evaluate the efficacy of dynamic MR imaging with the pulse sequences for the detection of hypervascular hepatocellular carcinoma by comparing it with that of dynamic helical CT with double arterial phase imaging. SUBJECTS AND METHODS: Fifty-three patients with 103 hypervascular hepatocellular carcinoma nodules who underwent both dynamic MR imaging with 3D Fourier transformation-enhanced fast gradient-echo sequences with a special spectral inversion recovery pulse and dynamic helical CT with double arterial phase imaging were enrolled in the study. For dynamic MR imaging, unenhanced, arterial, portal venous, and equilibrium phase images were obtained before and approximately 19, 60, and 120 sec, respectively, after injection of gadopentetate dimeglumine. Three observers independently interpreted the images obtained with each technique in a blinded manner and in random order. RESULTS: Mean sensitivity and positive predictive values of CT for hypervascular hepatocellular carcinoma (66% and 97%, respectively) were higher than those of MR imaging (63% and 96%, respectively), but there was no significant difference in detecting sensitivity among the observers (p < 0.05). CT and MR imaging were complementary, with some tumors undetected by CT but revealed on MR imaging. There was also no significant difference in A(z) values between CT (0.74) and MR imaging (0.71) (p < 0.05). CONCLUSION: Dynamic MR imaging with 3D Fourier transformation-enhanced fast gradient-echo sequences with a special spectral inversion recovery pulse is recommended to improve the detection of hypervascular hepatocellular carcinoma nodules in addition to the use of dynamic helical CT with double arterial phase imaging.

Aged↗

Preliminary evaluation: magnetic resonance of urography using a saturation inversion projection spin-echo sequence.

A saturation inversion projection (SIP) spin-echo technique is reported which allows a reliable direct visualization of the urogenital system as well as its functional performance in magnetic resonance imaging. We used an imaging sequence with a 90 degree saturation pulse and two 180 degree inversion pulses followed by a short spin-echo (SE) pulse sequence. The three time intervals in the 90 degree-180 degree-180 degree-SE pulse train were adjusted to suppress the signals of soft tissues and fat. After intravenous injection of the contrast agent Gd-DTPA, a shortening of the kidney T1 and the T1 of the urogenital system is obtained below the T1 values of fat and soft tissues, and these remaining ultra-short T1 tissues were imaged with the SIP sequence. Using a sequential measuring technique a quantitative evaluation of the glomerular filtration rate seems to be possible with a time resolution of 18 sec per image. In addition, magnetic resonance urography using the SIP sequence provided a good visualization of the urogenital system and may show several clinical utilities in further clinical studies.

Contrast Media↗

Improved convection compensating pulsed field gradient spin-echo and stimulated-echo methods.

The need for convection compensating methods in NMR has been manifested through an increasing number of publications related to the subject over the past few years (J. Magn. Reson. 125, 372 (1997); 132, 13 (1998); 131, 126 (1998); 118, 50 (1996); 133, 379 (1998)). When performing measurements at elevated temperature, small convection currents may give rise to erroneous values of the diffusion coefficient. In work with high resolution NMR spectroscopy, the application of magnetic field gradients also introduces an eddy-current magnetic field which may result in errors in phase and baseline in the FFT-spectra. The eddy current field has been greatly suppressed by the application of bipolar magnetic field gradients. However, when introducing bipolar magnetic field gradients, the pulse sequence is lengthened significantly. This has recently been pointed out as a major drawback because of the loss of coherence and of NMR-signal due to transverse relaxation processes. Here we present modified convection compensating pulsed field gradient double spin echo and double stimulated echo sequences which suppress the eddy-current magnetic field without increasing the duration of the pulse sequences.

Magnetic Resonance Spectroscopy↗

Measurements of restricted diffusion using an oscillating gradient spin-echo sequence.

An oscillating gradient spin-echo (OGSE) pulse sequence was used to measure the apparent diffusion coefficient (D(app)) of water in the short diffusion time regime in the presence of restrictions. The diffusion coefficients of water in a simple water sample and a water and oil mixture were measured to be the same for different periods of the gradient oscillation, as expected when there are no restriction effects. The D(app) of water in the spaces between closely packed beads was also measured as a function of the gradient oscillation periods in the range 11 to 80 ms. The D(app) of water in restricted systems varies with the period of the gradient oscillation and the dispersion depends on the scale of the restriction. For a sample of packed beads of diameter 9.1 +/- 0.7 microm, the pore surface-to-volume ratio was estimated experimentally by this method to be 1.3 +/- 0.1 microm(-1), corresponding to a mean pore diameter of 6.4 +/- 0.7 microm. A Monte Carlo computer simulation of the NMR OGSE signal from the spins diffusing in a system of compartments was also implemented and the D(app) demonstrated similar behavior with gradient oscillation periods.

Computer Simulation↗

Detection of choledocholithiasis with MR cholangiography: comparison of three-dimensional fast spin-echo and single- and multisection half-Fourier rapid acquisition with relaxation enhancement sequences.

PURPOSE: To compare the performance of three pulse sequences commonly used at magnetic resonance (MR) cholangiography in the diagnosis of choledocholithiasis. MATERIALS AND METHODS: MR cholangiography was performed in 57 patients who were suspected of having choledocholithiasis and referred for endoscopic retrograde cholangiography. Non-breath-hold three-dimensional fast spin-echo, breath-hold single-section half-Fourier rapid acquisition with relaxation enhancement (RARE), and breath-hold multisection half-Fourier RARE sequences were compared. Two radiologists independently interpreted the MR cholangiograms. Evaluated diagnostic performance parameters included sensitivity, specificity, receiver operating characteristic (ROC) curves, and interobserver agreement (kappa statistics). Endoscopic retrograde cholangiography was the standard of reference. RESULTS: Eight patients were excluded because of incomplete MR examinations (n = 4) or failure in the cannulation of the bile duct at retrograde cholangiography (n = 4). In 49 patients, the three MR cholangiographic sequences were completed successfully. In 24 (49%) of these patients, retrograde cholangiography demonstrated stones. Sensitivity and specificity of MR cholangiography exceeded 90%, and the area under the ROC curve was greater than 0.95 for both radiologists and for the three sequences. Interobserver agreement for presence of bile duct stones was at least 0.80 (very good) for the three sequences. CONCLUSION: The three MR cholangiographic sequences had similarly high sensitivities and specificities for the detection of choledocholithiasis.

Adolescent↗

"Black blood" T2-weighted inversion-recovery MR imaging of the heart.

PURPOSE: To develop a short-inversion-time inversion-recovery (STIR) magnetic resonance imaging pulse sequence for evaluating the myocardium that is relatively free of flow and motion artifact. MATERIALS AND METHODS: The authors implemented a breath-hold, cardiac-triggered STIR sequence with preparatory radio-frequency pulses to eliminate signal from flowing blood. A segmented rapid acquisition with relaxation enhancement (turbo spin echo) readout was used, with the inversion-recovery delay adjusted to null fat. The sequence was implemented at 1.0 and 1.5 T and tested in phantoms, five healthy volunteers, and three patients. RESULTS: Phantom studies confirmed the expected behavior of the sequence. In the volunteers, fat-suppressed images of the heart with STIR contrast were generated in a breath-hold period. Blood in the heart chambers was uniformly nulled, and motion artifacts were effectively suppressed. Focal high signal intensity consistent with edema was seen in two patients with acute myocardial infarction; in a third patient, a paracardiac mass was visualized and sharply demarcated relative to normal myocardium. CONCLUSION: Fast STIR imaging of the heart with effective suppression of flow and motion artifacts was implemented. The approach has much potential for high-contrast imaging in a variety of diseases affecting the heart and mediastinum.

Adult↗

Signal loss induced by superparamagnetic iron oxide particles in NMR spin-echo images: the role of diffusion.

MR contrast agents are used to improve the detectability of pathologic conditions. In this study we clarify the mechanism of action of a newly developed superparamagnetic agent (AMI-25, Advanced Magnetics Inc., Cambridge, MA). Transverse relaxation rates were measured from segments of rat brain, heart, and liver using a CPMG pulse sequence. Relaxation rates varied with the time interval between the refocusing pulses in the sequence (tau). The diffusion effect on signal intensity was quantitated from the variation of T2 with tau. We find that diffusion in the presence of microscopic field gradients reduces T2, and that this effect differs in magnitude among tissues. Superparamagnetic iron oxide particles enhance this T2 reduction. The dependence of T2 upon tau suggests a model of restricted diffusion. Tissue image contrast induced by superparamagnetic iron oxide in spin-echo NMR studies is the result of a combination of diffusion-dependent and diffusion-independent differences in transverse relaxation.

Animals↗

Imaging of shifted stimulated echoes and multiple spin echoes.

It is shown that a repetitive pulse sequence consisting of two 90 degrees pulses and gradients in a 1:2 ratio around the second 90 degrees pulse generates interscan shifted stimulated echoes (SSTEs) and intrascan multiple spin echoes (MSEs). Separation of these two types of signals is accomplished using specific gradient crusher schemes. The intensity of the SSTEs is an order of magnitude larger than that of the MSEs and determines the signal contrast if both effects are selected simultaneously. The SSTE sequence generates improved contrast between gray and white matter, even at high field, which is explained in terms of increased inverse T1-weighting for the interscan echo. The MSE image has low signal to noise and no detectable contrast. The effect of interscan diffusion weighting is also discussed.

Animals↗

Determination of heteronuclear three-bond J-coupling constants in peptides by a simple heteronuclear relayed E.COSY experiment.

A simple heteronuclear relayed E.COSY pulse sequence with a minimum number of pulses is proposed for the quantitative determination of heteronuclear three-bond J-coupling constants in uniformly 13C-enriched polypeptide samples. Numerous heteronuclear three-bond coupling constants, including 3JHNC, 3JHNC beta, 3JH beta C, and 3JH alpha C gamma, can be determined for each residue from a single heteronuclear relayed E.COSY spectrum. Couplings relevant for stereospecific assignments as well as for the determination of dihedral angles in the amino acid backbone and in side chains are obtained. The method is demonstrated on the uniformly 13C-enriched decapeptide antamanide (-Val1-Pro2-Pro3-Ala4-Phe5-Phe6-Pro7-Pro8-Phe9-Phe1 0-).

Amino Acid Sequence↗

T 1 rho-relaxation mapping of human femoral-tibial cartilage in vivo.

PURPOSE: To demonstrate the in vivo feasibility of measuring spin-lattice relaxation time in the rotating frame (T(1rho)); and T(1rho)-dispersion in human femoral cartilage. Furthermore, we aimed to compute the baseline T(1rho)-relaxation times and spin-lock contrast (SLC) maps on healthy volunteers, and compare relaxation times and signal-to-noise ratio (SNR) with corresponding T(2)-weighted images. MATERIALS AND METHODS: All MR imaging experiments were performed on a 1.5 T GE Signa scanner (GEMS, Milwaukee, WI) using a custom built 15-cm transmit-receive quadrature birdcage radio-frequency (RF) coil. The T(1rho)-prepared magnetization was imaged with a single-slice two-dimensional fast spin-echo (FSE) pulse sequence preencoded with a three-pulse cluster consisting of two hard 90 degrees pulses and a low power spin-lock pulse. T(1rho)-dispersion imaging was performed by varying the spin-lock frequency from 100 to 500 Hz in five steps in addition to varying the length of the spin-lock pulse. RESULTS: The average T(1rho)-relaxation times in the weight-bearing (WB) and nonweight-bearing (NWB) regions of the femoral condyle were 42.2 +/- 3.6 msec and 55.7 +/- 2.3 msec (mean +/- SD, N = 5, P < 0.0001), respectively. In the same regions, the corresponding T(2)-relaxation times were 31.8 +/- 1.5 msec and 37.6 +/- 3.6 msec (mean +/- SD, N = 5, P < 0.0099). T(1rho)-weighted images have approximately 20%-30% higher SNR than the corresponding T(2)-weighted images for similar echo time. The average SLC in the WB region of femoral cartilage was 30 +/-4.0%. Furthermore, SLC maps provide better contrast between fluid and articular surface of femoral-tibial joint than T(1rho)-maps. The T(1rho)-relaxation times varied from 32 msec to 42 msec ( approximately 31%) in the WB and 37 msec to 56 msec ( approximately 51%) in NWB regions of femoral condyle, respectively, in the frequency range 0-500 Hz (T(1rho)-dispersion). CONCLUSION: The feasibility of performing in vivo T(1rho) relaxation mapping in femoral cartilage at 1.5T clinical scanner without exceeding Food and Drug Administration (FDA) limits on specific absorption rate (SAR) of RF energy was demonstrated.

Adult↗

Dynamic range compression in MRI by means of a nonlinear gradient pulse.

In current magnetic resonance imaging (MRI), valuable information must often be discarded because the NMR signal has greater dynamic range than the analog-to-digital converter (ADC) hardware. Typically, a small set of high-intensity data points near the center of the spin echo is responsible for most of the MRI data dynamic range. We predict that it is possible to reduce the dynamic range of the MRI spin echo by incorporating an identical nonlinear gradient pulse into each repetition of the imaging pulse sequence, prior to data sampling. This pulse converts the phase distribution of the subject, ordinarily a linear function of image coordinates, into a nonlinear function. A nonlinear phase distribution can have a negligible impact on image magnitude and yet a profound impact on spin-echo magnitude. Given a nonlinear phase distribution, there will no longer be a single data point at which all of the protons have an identical phase (the echo center). Instead, the protons become phase coherent on a piecemeal basis, the echo peak is smoothed out, and its maximum amplitude and dynamic range are greatly diminished. Using gradient pulses of quadratic spatial variation, we estimate that maximum echo amplitude and dynamic range can be reduced in most cases by an order of magnitude.

Analog-Digital Conversion↗