Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Photometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Transfer and tunneling of Ca2+ from sarcoplasmic reticulum to mitochondria in skeletal muscle.

The role of mitochondrial Ca2+ transport in regulating intracellular Ca2+ signaling and mitochondrial enzymes involved in energy metabolism is widely recognized in many tissues. However, the ability of skeletal muscle mitochondria to sequester Ca2+ released from the sarcoplasmic reticulum (SR) during the muscle contraction-relaxation cycle is still disputed. To assess the functional cross-talk of Ca2+ between SR and mitochondria, we examined the mutual relationship connecting cytosolic and mitochondrial Ca2+ dynamics in permeabilized skeletal muscle fibers. Cytosolic and mitochondrial Ca2+ transients were recorded with digital photometry and confocal microscopy using fura-2 and mag-rhod-2, respectively. In the presence of 0.5 mM slow Ca2+ buffer (EGTA (ethylene glycolbis(2-aminoethylether)-N,N,N',N'-tetraacetic acid)), application of caffeine induced a synchronized increase in both cytosolic and mitochondrial [Ca2+]. 5 mM fast Ca2+ buffer (BAPTA (1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid)) nearly eliminated caffeine-induced increases in [Ca2+]c but only partially decreased the amplitude of mitochondrial Ca2+ transients. Confocal imaging revealed that in EGTA, almost all mitochondria picked up Ca2+ released from the SR by caffeine, whereas only about 70% of mitochondria did so in BAPTA. Taken together, these results indicated that a subpopulation of mitochondria is in close functional and presumably structural proximity to the SR, giving rise to subcellular microdomains in which Ca2+ has preferential access to the juxtaposed organelles.

Animals↗

A portable instrument for measuring macular pigment with central fixation.

PURPOSE: To evaluate the reliability and validity of a portable instrument for measuring macular pigment optical density. METHODS: The instrument is small, uses light emitting diodes as light sources and the principles of heterochromatic flicker photometry of comparing foveal and extra-foveal minimum flicker matches. It uses central fixation for the extra-foveal matches, which subjects found easier than eccentric fixation. Subjects with healthy eyes used the instrument to measure their pigment density in a number of eye clinics. RESULTS: The mean pigment density in 124 eyes in 124 individuals was 0.41 +/- 0.16 (mean +/- SD), there was no significant change with age but the density was less in females, those with light irides, smokers, subjects on diets low in precursor carotenoids and in those exposed to several hours of daylight every day or who used sun beds. CONCLUSIONS: The portable instrument gave valid and reliable data that confirmed published values for macular pigment. It was convenient to use in the clinic and has potential as a screening tool.

Adolescent↗

Ocular and central nervous system lymphoma: clinical features and diagnosis.

PURPOSE: To evaluate the clinical, angiographic, and cytopathologic features of ocular and central nervous system (CNS) lymphoma. PATIENTS AND METHODS: Retrospective study of 44 patients over a 10-year period. RESULTS: A total of 36 women and six men, mean age 54 years (range: 36-90 years), were included. The mean time interval between onset of ocular symptoms and diagnosis was 40 months (range: 1-144 months). Ocular involvement was bilateral in 84% of the cases. Laser flare photometry readings averaged 9.6 photons/ms (2.9-78.3 photons/ms). Vitritis was constant. Funduscopy revealed RPE abnormalities in 60.49% of the cases and punctuate retinal infiltrates in 33.5%. The most common findings with fluorescein angiography were window defects and hypofluorescent round lesions. Patients had CNS involvement in 66% of the cases. Cytologic examination of the vitreous samples showed high-grade B lymphoma in 86% of the cases. Interleukin-10 dosage, when performed, showed elevated levels averaging 2352 pg/ml in all vitreous samples. Molecular biology based on PCR confirmed the diagnosis in 12 patients. Treatment included systemic chemotherapy alone or associated with radiotherapy in various regimens. Fourteen patients died during follow-up. Only 12 patients were in complete remission. CONCLUSION: The prognosis of the disease remains poor. However, the new diagnostic tools and therapeutic strategies may improve the diagnostic delay and the survival outcome.

Adult↗

Efficacy of interferon alfa-2a in severe and refractory uveitis associated with Behçet's disease.

PURPOSE: To evaluate the efficacy of interferon alfa-2a (IFN alfa) in severe uveitis associated with Behçet's disease, that is refractory to steroids and conventional immunosuppressive agents. PATIENTS AND METHODS: Patients with Behçet's disease (according to the International Study Group criteria), who relapsed despite steroids and immunosuppressive agents, were included in this retrospective study. Ophthalmological examination, laser flare photometry, and fluorescein angiography associated with laboratory tests were performed at regular intervals. IFN alfa (3 millions units thrice a week) was injected subcutaneously. RESULTS: Eight patients (sex ratio: 1) were included between May 1995 and January 1999. The mean age was 29.1 years (14-54 years) and the disease was present between 11 and 167 months before the administration of IFN alfa. IFN alfa was efficient in all cases with a mean follow-up of 22 months (10-55 months). Steroids were tapered from a mean dosage of 47 mg/d to a mean dosage of 8.5 mg/d. Ocular inflammation was controlled and visual acuity improved in all cases. Treatment was generally well tolerated despite a constant but transient flu-like syndrome. IFN alfa was tapered in three patients and stopped in one case without any relapse after five months. CONCLUSIONS: Within the limitations of this retrospective study, low-dose IFN alfa seems to be well tolerated, promising in the management of refractory forms of uveitis due to Behçet's disease, and effective in allowing a reduction of steroid dosage. A prospective controlled study is necessary to confirm these preliminary results.

Adolescent↗

Effects of a high sucrose diet and intragastric sucrose feeding on the dentinogenesis, dental caries, and mineral excretion of the young rat.

Previous studies show that a high sucrose diet reduces the rate of primary dentinogenesis and increases dental caries, although their cause-effect relationship is still obscure. The purpose of this study was to explore whether the effect of sucrose load on the dentinogenesis and dental caries of young rat molars is mediated by systemic (intragastric) or by systemic and local (dietary) factors. At weaning (19 days), animals were randomized into the control, intragastric sucrose, and dietary sucrose groups for 4 weeks. The areas of dentin appositions and dentinal caries lesions were measured planimetrically. Caries was also determined with Shiffs staining and the width of predentin by histology. Urinary Ca, K, and Na levels were measured by flame photometry, urinary P levels using an UV method, and serum insulin levels using radioimmunoassay. Systemic and local sucrose load reduced dentin appositions and intragastric sucrose increased urinary Ca excretion. No differences in the width of predentin were noticed. Only dietary sucrose enhanced the occurrence and progression of caries. The present findings show that sucrose load reduces dentinogenesis by impairing the synthesis of dentin matrix, but also point out the crucial importance of the local sucrose challenge in the initiation of dental caries.

Analysis of Variance↗

Drug effects on calcium homeostasis in mouse CA1 hippocampal neurons.

Voltage-dependent Ca2+ channels (VDCC) are important in control of neuronal excitability, synaptic transmission, and many other cellular process. Even the slightest alteration in Ca2+ currents can have a considerable impact on the neuronal function. However, it is still unknown whether Ca2+ currents are affected by neurotoxic drugs such as lead, cobalt, zinc, cadmium, thallium, lanthanum, and aluminum. We have characterized the effects of neurotoxic drugs on Ca2+ homeostasis in CA1 hippocampal C57BL mice. Fura 2-AM fluorescence photometry was used to measure intracellular Ca2+ concentration ([Ca2+]i) in the presence and absence of neurotoxic drugs (10 microM) in response to KCl application. The peak [Ca2+]i due to KCl application was reduced in the presence of lead (60%), cobalt (35%), zinc (62%), cadmium (71%), thallium (27%), and lanthanum (66%). By contrast, in the presence of aluminum the peak [Ca2+]i was either increased (46%) or it was not affected. These results indicate that neurotoxic drugs could block the entry of calcium into CA1 neurons via VDCC.

Aluminum↗

Increased calcium influx through acetylcholine receptors in dunce neurons.

Calcium homeostasis was studied in dunce, a Drosophila mutant that is defective in learning and memory. Fura 2-AM fluorescence photometry was used to measure the intracellular calcium concentration in wild type and dunce cleavage-arrested neurons under resting conditions and in response to neurotransmitters. After acetylcholine application, the peak [Ca2+]i was greater in dunce (693 +/- 125 nM) than in wild type neurons (464 +/- 154 nM), but half decay time was shorter in dunce (66 +/- 15 s) than in wild type neurons (104 +/- 40 s). In contrast, the application of glutamate, NMDA, dopamine, and serotonin had no effect on [Ca2+]i. These results indicate that calcium influx through acetylcholine receptors is increased in dunce, compared to wild type neurons. The results also suggest that calcium extrusion to the outside and/or calcium buffering are enhanced in dunce, compared to wild type neurons. This disturbance in the homeostasis of cytosolic calcium concentration in dunce may be implicated in defective associative learning in Drosophila, and may play a role in acute and chronic neurodegenerative disorders in the mammalian brain.

Acetylcholine↗

Calculation of single-ion activities in solutions simulating blood plasma.

While, in principle, flame photometry of sodium and potassium measures substance concentration, and ion-selective electrodes (ISEs) measure ion activity, the situation regarding the comparison of results from the two techniques when applied to blood plasma is complex. The problem can be approached experimentally from the point of view of calibration of ISEs with concentration standards, and similar procedures are adopted for commercial ISE-based clinical analysers. Nevertheless, there is interest in the evaluation of single ion activities in blood plasma and solutions simulating its ionic composition. The theory of mixed electrolyte solutions developed by Pitzer has been applied to some solutions currently proposed for calibrating ISEs, and the results compared with the Stokes-Robinson-Bates hydration approach. It is recommended that the values from the Pitzer treatment be adopted, because, although this has some empirical features, it has a sounder theoretical basis than the Stokes-Robinson-Bates hydration approach.

Calibration↗

A review of 23Na nuclear magnetic resonance spectroscopy for the in vitro study of cellular sodium metabolism.

Changes in intracellular sodium have been associated with a number of different diseases. Consequently, various methods have been used to quantify the level of intracellular sodium concentrations. Traditional methods like flame photometry and ion-selective electrodes are destructive or invasive, thereby potentially altering the intracellular sodium levels. There has been an increasing interest in evaluating the method of 23Na nuclear magnetic resonance in recent years, since this method allows for non-invasive continuous monitoring of intracellular sodium in cell suspensions and tissues. A phenomenological approach to basic theory, review of methodology, applications to the in vitro study of cellular sodium metabolism, and difficulties of interpretation of this analytical modality is presented.

Erythrocytes↗

Ion effects in measurement of sodium and ionized calcium in direct potentiometry.

In some instruments that measure sodium directly in whole blood, plasma, or serum using ion selective electrodes (direct potentiometry), the higher the ionic strength of the solution, the lower is the sodium recovery in serum, as predicted by theory. The same could be expected for ionized calcium. When measuring the recovery of serum sodium on indirect potentiometric instrument and by flame photometry, which determine concentration in prediluted samples, and on direct potentiometric instruments, we observed that two out of the three direct potentiometry instruments showed a decreased recovery of sodium, as the ionic strength was increased, while on all the other instruments the recovery was complete. No effect of increased ionic strength was noted on the ionized calcium measurements in serum on all the instruments tested. Analysing pure aqueous solutions of sodium and calcium chloride with increased ionic strength on the same instruments, the sodium recovery was always complete or positive, and the same was true for ionized calcium. We postulate some effect of ionic strength on the salt bridge of the measuring systems, which is different when analysing serum or pure aqueous solutions.

Calcium↗

Do vesical and voided urine have identical compositions?

OBJECTIVE: In view of the concept that the urothelium is a functioning epithelium, we investigated the hypothesis that the composition of urine is modified as it passes through the urethra from the urinary bladder to the exterior. MATERIAL AND METHODS: The study was performed in 22 healthy volunteers (13 males, 9 females; mean age 44.6+/-6.2 years). Vesical and voided urine were collected separately; pH was determined using a pH electrode, osmolality by means of micro-osmometry and electrolytes (Na, K) using flame photometry. RESULTS: Voided urine showed significant increases in pH, osmolality and Na and K concentrations compared to urine contained in the bladder (p < 0.05 for each). Gender and age differences were not significant. CONCLUSIONS: Vesical urine undergoes changes in some of its components during its passage through the urethra. These findings presumably indicate that the urethral urothelium is a functioning epithelium and also that voided and vesical urine are not identical. The study raises the question to what extent is the analysis of voided urine representative of that of vesical urine?

Adult↗

Bread as a source of salt: an international comparison.

OBJECTIVE: The salt (NaCl) content of bread, obtained from Belgium and 25 other regions or countries worldwide, was analyzed to evaluate the importance of bread as a source of dietary salt in a population. METHODS: A total of 1166 dried bread samples were analyzed using a hot HCl extraction technique followed by flame photometry and performed by the same laboratory technician in Leuven (Belgium); 534 samples from Leuven were analyzed over 10 time periods from 1967-73 to 1992 together with 562 samples from 11 other European countries, 44 from the United States and Peru, and 26 from Asia. RESULTS: The average mean salt content of fresh bread (= dried bread times 0.6) in European countries was 12.4 +/- 1.7 g/kg for white and 13 +/- 1.0 g/kg for brown bread. In Japan and Korea it was about 8.5 g/kg and in Pakistan, Thailand, Nepal, and Laos about 5 g/kg. The mean sodium/potassium ratio with Na and K in mmol was 8.0 for white and 4.5 for brown bread, much higher than the recommended value of 1.0. Bread with a very low salt content was found in certain areas of Peru, Spain, and Italy. CONCLUSION: The overall salt content of bread in Western countries is excessive, and a gradual reduction is highly desirable.

Asia↗

Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.

AIM: Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. METHODS: Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. RESULTS: Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method (GD = glucose difference between study analyser and reference method) However, the venous samples analysed by EML 105 estimated plasma glucose significantly better than capillary samples using the same method of analysis (GD = 0.24, 95% CI. [0.09,0.38], p < 0.01). The relationship between haematocrit and the resultant glucose differences was non-linear with correlation coefficients of r = -0.057 (EML 105 capillary), r = 0.145 (EML 105 venous), r = -0.127 (Advantage capillary) and r = -0.275 (Advantage venous). There was no significant difference in the effect of haematocrit on the performance of EML 105 versus Advantage, regardless of the sample route. CONCLUSION: Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.

Blood Chemical Analysis↗

Comparison of two strip test methods of whole blood glucose measurement in the neonatal period.

UNLABELLED: The aim of this study was to compare the performance and accuracy of the BM Strip test used in conjunction with Reflectance photometry, and the new non-wipe strip test (Advantage) against a reference plasma glucose method. In total, 114 newborns consecutively admitted to the Neonatal Unit over a 6 mo period were enrolled into the study. Each newborn had their venous blood glucose measured by the BM Strip test and Advantage glucometer and the venous haematocrit was also determined. Plasma glucose was measured in the laboratory by the hexokinase method. The mean difference between the BM Strip test and plasma glucose was significantly less than the corresponding value for the Advantage glucometer (0.312, 95% confidence interval (CI) 0.11-0.51 vs 0.766, 95% CI 0.57-0.95], although the limits of agreement between both methods and plasma glucose were wide. Haematocrit did not influence significantly the accuracy of either test. CONCLUSION: The new Advantage glucose meter does not offer any advantage over the BM Strip test. Owing to the wide limits of agreement of both methods compared with plasma glucose, their clinical value is limited in the neonatal period.

Blood Chemical Analysis↗

Deleterious effect of zinc in a pig model of acute endotoxemia.

By antiapoptotic effects and the induction of the heat-shock response, zinc is supposed to be a promising means of therapy during sepsis. As zinc also stimulates the expression of proinflammatory cytokines, its administration during the proinflammatory stage of septic shock might have adverse effects. Therefore, this study analyzes the influence of zinc during the acute phase of endotoxemia. In a pig model of acute endotoxemia, animals were divided into two groups: group I (n = 5) with saline treatment and group II (n = 5) with zinc treatment in close succession to lipopolysaccharide (LPS) (1.0 mu g/kg Escherichia coli endotoxin WO 111:B4). Hemodynamic and pulmonary monitoring was followed by combined reflection photometry, pulse oxymetry, blood gas samples, and temperature measurement. Plasma concentrations of tumor necrosis factor (TNF)alpha and interleukin (IL)-6 were analyzed by enzyme-linked immunosorbent assay (ELISA). Morphology included the weight of the lungs, the width of the alveolar septae, and the paracentral necrosis rate of the liver. After LPS infusion, group II (zinc) showed an impressive and significant deterioration of all pulmonary and most of the hemodynamical parameters compared to group I (saline). Levels of TNFalpha and IL-6 measured were significantly higher after zinc treatment. In accordance, we found significant more morphologic damages in group II (zinc). The almost simultaneous infusion of zinc and LPS complementary induced proinflammatory effects with a deleterious outcome. The same potentials characterizing zinc as a promising tool of prophylactic therapy in sepsis seem to ban its use during the acute phase.

Acute Disease↗

Exposure of human lung cells to inhalable substances: a novel test strategy involving clean air exposure periods using whole diluted cigarette mainstream smoke.

An experimental approach was established for the validation of an in vitro test system for complex environmental test atmospheres consisting of both gaseous substances and particulates. Smoke from two different cigarette types (generated by an automatic cigarette-smoking machine) was employed to assess both the sensitivity and the specificity of the system. The smoke was diluted with synthetic air and used to expose human lung cells grown on microporous membranes. Cells were exposed alternately to diluted cigarette smoke and pure synthetic air. The effect of diluted smoke was assessed without humidification, addition of CO2, or any other physical or chemical modification of the smoke. The experimental setup included online monitoring of the gas phase (by analysis of CO concentration) and particulate phase (by light-scattering photometry). Replicate experiments confirmed a reproducible generation and dilution of the smoke and a smoke age of about 7 s at the time it came into contact with the cells. Experiments using human lung cells revealed that smoke from the two different cigarette types induced different levels of dose-dependent toxicity. A cell exposure of 6 min using 6 alternating smoke and synthetic air periods was sufficient to cause different effects as measured by intracellular glutathione content. The fact that the system could differentiate between two different types of cigarette smoke demonstrated its high sensitivity and specificity. The system offers new ways to test native complex gaseous and aerosol mixtures in vitro using short exposure times and very small amounts of test substances.

Aerosols↗

Effect of race on fine particle deposition for oral and nasal breathing.

Nasal efficiency for removing fine particles from inhaled air may be affected by variations in nasal structure associated with race. In 11 African American and 11 Caucasian adults (age 18-31 yr) we measured the fractional deposition (DF) of fine particles (1 and 2 mum mass median aerodynamic diameter) (MMAD) for oral and nasal breathing using individual breathing patterns previously measured by respiratory inductance plethysmography during a graded exercise protocol. DF for both nasal and mouth breathing was measured separately by laser photometry at the same tidal volume and breathing rate for resting and light exercise (20% of maximum work load) conditions. From these DF measures, nasal deposition efficiency (NDE) was calculated for each condition. For light exercise conditions, NDE for both 1- and 2-microm particles was less in African Americans versus Caucasians, 0.15 +/- 0.07 (SD) versus 0.24 +/- 0.11 for 1-microm particles (p = .03), and 0.29 +/- 0.13 versus 0.44 +/- 0.11 for 2-microm particles (p = .006). The racial differences in NDE were associated with racial differences in nasal resistance and nostril shape. These race-dependent nasal efficiencies are dosimetric factors that should be considered in modeling and assessing particulate dose from human exposure to air pollutants.

Adolescent↗

Development of a continuous monitoring system for PM10 and components of PM2.5.

While particulate matter with aerodynamic diameters below 10 and 2.5 microns (PM10 and PM2.5) correlate with excess mortality and morbidity, there is evidence for still closer epidemiological associations with sulfate ion, and experimental exposure-response studies suggest that the hydrogen ion and ultrafine (PM0.15) concentrations may be important risk factors. Also, there are measurement artifacts in current methods used to measure ambient PM10 and PM2.5, including negative artifacts because of losses of sampled semivolatile components (ammonium nitrate and some organics) and positive artifacts due to particle-bound water. To study such issues, we are developing a semi-continuous monitoring system for PM10, PM2.5, semivolatiles (organic compounds and NH4NO3), particle-bound water, and other PM2.5 constituents that may be causal factors. PM10 is aerodynamically sorted into three size-fractions: (1) coarse (PM10-PM2.5); (2) accumulation mode (PM2.5-PM0.15); and (3) ultrafine (PM0.15). The mass concentration of each fraction is measured in terms of the linear relation between accumulated mass and pressure drop on polycarbonate pore filters. The PM0.15 mass, being highly correlated with the ultrafine number concentration, provides a good index of the total number concentration in ambient air. For the accumulation mode (PM2.5-PM0.15), which contains nearly all of the semivolatiles and particle-bound water by mass, aliquots of the aerosol stream flow into system components that continuously monitor sulfur (by flame photometry), ammonium and nitrate (by chemiluminescence following catalytic transformations to NO), organics (by thermal-optical analysis) and particle-bound water (by electrolytic hygrometer after vacuum evaporation of sampled particles). The concentration of H+ can be calculated (by ion balance using the monitoring data on NO3-, NH4+, and SO4=).

Air Pollution, Indoor↗