Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Particle Size”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Measurement of particle sizes by elastic and quasi-elastic light scattering.

A method of measuring an average particle radius in a highly polydisperse dispersion using the wavelength dependence of turbidity is described. For particles which are no larger than 0.3 of the wavelength of light used, a polynomial representation of the scattering cross-section can be used. For larger particles, more extensive numerical calculations are required. The use of the method is illustrated by determining the average particle radius of casein micelles by both elastic and quasi-elastic light scattering techniques. A polydisperse homogeneous sphere model is found to be a reasonably accurate representation of casein micelles. Several modifications of the model which would improve the agreement between the two techniques are mentioned briefly.

Animals↗

Treatment of obesity with diet/exercise versus pioglitazone has distinct effects on lipoprotein particle size.

OBJECTIVE: We compared the effects of diet/exercise induce weight loss versus pioglitazone on lipoprotein particle characteristics in non-diabetic, insulin resistant adults to determine whether the responses and potential mechanisms for improvement are similar between these two insulin sensitizing regimens. METHODS AND RESULTS: Thirty-seven obese, insulin resistant volunteers were randomized to 19 weeks of either pioglitazone or diet/exercise treatment. Insulin sensitivity (Si) by IVGTT and lipoprotein subclass particle profiles by NMR was measured. Only diet/exercise lowered TG (-40+/-11 mg/dL), total (-29+/-4 mg/dL) and LDL cholesterol (-20+/-4 mg/dL; all p<0.01). Both diet/exercise and pioglitazone improved Si (p<0.05), decreased total LDL particles (-227+/-40 and -149+/-21 nmol/L, respectively, both p<0.001) and small LDL particles (-242+/-58 and -226+/-36, respectively, both p<0.001). Large LDL particle concentrations increased with both treatments. LDL particle subclasses changes correlated with changes in Si only in the diet/exercise group. CONCLUSION: In obese, insulin resistant non-diabetic adults, pioglitazone improved LDL particle characteristics in a manner similar to diet/exercise without changing TG, diabetic control, total or LDL cholesterol. This effect could have implications for atherosclerotic risk.

Adult↗

Particle size determinants in the human immunodeficiency virus type 1 Gag protein.

The retroviral Gag protein plays the central role in the assembly process and can form membrane-enclosed, virus-like particles in the absence of any other viral products. These particles are similar to authentic virions in density and size. Three small domains of the human immunodeficiency virus type 1 (HIV-1) Gag protein have been previously identified as being important for budding. Regions that lie outside these domains can be deleted without any effect on particle release or density. However, the regions of Gag that control the size of HIV-1 particles are less well understood. In the case of Rous sarcoma virus (RSV), the size determinant maps to the CA (capsid) and adjacent spacer sequences within Gag, but systematic mapping of the HIV Gag protein has not been reported. To locate the size determinants of HIV-1, we analyzed a large collection of Gag mutants. To our surprise, all mutants with defects in the MA (matrix), CA, and the N-terminal part of NC (nucleocapsid) sequences produced dense particles of normal size, suggesting that oncoviruses (RSV) and lentiviruses (HIV-1) have different size-controlling elements. The most important region found to be critical for determining HIV-1 particle size is the p6 sequence. Particles lacking all or small parts of p6 were uniform in size distribution but very large as measured by rate zonal gradients. Further evidence for this novel function of p6 was obtained by placing this sequence at the C terminus of RSV CA mutants that produce heterogeneously sized particles. We found that the RSV-p6 chimeras produced normally sized particles. Thus, we present evidence that the entire p6 sequence plays a role in determining the size of a retroviral particle.

HIV Core Protein p24↗

Multiple-instrument analyses of single micron-size particles.

Physical, chemical, and isotopic analyses of individual radioactive and other particles in the micron-size range, key tools in environmental research and in nuclear forensics, require the ability to precisely relocate particles of interest (POIs) in the secondary ion mass spectrometer (SIMS) or in another instrument, after having been located, identified, and characterized in the scanning electron microscope (SEM). This article describes the implementation, testing, and evaluation of the triangulation POIs re-location method, based on microscopic reference marks imprinted on or attached to the sample holder, serving as an inherent coordinate system. In SEM-to-SEM and SEM-to-SIMS experiments re-location precision better than 10 microm and 20 microm, respectively, is readily attainable for instruments using standard specimen stages. The method is fast, easy to apply, and facilitates repeated analyses of individual particles in different instruments and laboratories.

Journal Article↗

Iodinated E. coli 70S ribosomes as a radiocolloid of uniform particle size for lymph-node and liver scanning.

As an example of the use of biologic particles as carriers for radioactive tracers, E. coli 70S ribosomes were labeled with I-125 using chloramine-T. The labeled ribosomes, after treatment with glutaraldehyde, were injected into rabbits either subcutaneously (through the dorsum of the foot) or intravenously (through the ear). After subcutaneous injection, 40% of the activity accumulated in the lymph nodes during the first 5 hr, and the 70S ribosomal particles were shown to remain within the lymphatic system for at least 8 hr. After intravenous injection, 71% of the activity was detected in the liver within minutes by scintigraphic techniques. The effective half-time of the label in the liver from glutaraldehyde-treated I-125-tagged 70S ribosomal colloidal particles is 4-5 hr. No pyrogenic response was observed. Barring any deleterious side effects, the results indicate that biologic cell components of definite dimensions (in this case E. coli 70S ribosomes about 20 nm in diam) could be considered as radiocolloids for lymph-node and liver imaging.

Animals↗

LDL particle size in familial combined hyperlipidemia: effects of serum lipids, lipoprotein-modifying enzymes, and lipid transfer proteins.

Small, dense LDL particles are typical for FCHL. Intravascular lipid exchange and net transfer among HDL, LDL, and triglyceride-rich lipoproteins as well as lipolysis in the VLDL-IDL-LDL cascade regulate properties of LDL. We investigated postheparin plasma activities of hepatic lipase (HL) and LPL, and plasma activities of CETP and phospholipid transfer protein (PLTP) in 191 individuals from 37 Finnish FCHL families. LDL peak particle diameter (LDL size) was measured with 2-10% gradient polyacrylamide gel electrophoresis. LDL size was significantly smaller in affected FCHL family members (n = 68) as compared with nonaffected FCHL family members (n = 78) or spouses (n = 45) (25.3 +/- 1.5 nm, 26.8 +/- 1.2 nm, and 26.6 +/- 1.2 nm, respectively, P < 0.001 for both). In affected FCHL family members, serum triglycerides were the strongest correlate for LDL size (r = -0.71, P < 0.001). In univariate correlation analysis LDL size was not associated with HL, LPL, CETP, and PLTP activities. In multivariate stepwise regression analysis, however, serum triglycerides, CETP activity, HL activity, and HDL cholesterol were significant predictors of LDL size in affected FCHL subjects (adjusted r (2) = 0.642). We conclude that serum triglyceride concentration is strongly correlated with LDL size in affected FCHL subjects. After adjustment for serum triglycerides, HL and CETP activities are associated with LDL size in FCHL.

Adult↗

Analysis of particle size generated during plaque ablation with a flashlamp pumped pulsed dye laser.

PURPOSE: To examine debris size generated during in vitro plaque ablation by laser energy and estimate the risk of peripheral embolization following laser angioplasty. METHODS: A flashlamp pumped pulsed dye laser of 480-nm wavelength was used to ablate calcified arteriosclerotic plaque, fibrous fatty plaque, and normal aortic wall on samples of human cadaver aortas. Each tissue sample was immersed in saline solution and treated with the same amounts of laser energy transmitted by a 320 microns-diameter glass fiber in direct tissue contact. The debris generated during plaque ablation was then separated from the supernatant and the particles were counted and analyzed for size. RESULTS: Depending on the underlying type of tissue and the setting of laser energy, a wide range of particles with sizes between 5.3 mm2 and 64 microns 2 was found in samples. The largest particles were found after ablation of calcified atherosclerotic plaque, whereas fibrous, fatty plaque and normal aortic wall showed smaller particles and a lesser amount of debris. CONCLUSION: Our study demonstrates that a considerable amount of debris is generated during laser angioplasty at 480 nm and that particle size is sufficient to cause potentially symptomatic embolic occlusions of mid- and small-sized peripheral arteries.

Angioplasty, Laser↗

Estimation of average particle size from vertical projections.

A new stereological relationship is derived for the estimation of average size (average width) of a collection of convex particles in a 3D microstructure. The average size is estimated from measurements performed on projected images of the microstructure generated by total vertical projections. The stereological relationship is as follows: D = IC/(2N0beta). D is the average width, ;IC is the average absolute number of intersections between the specifically oriented and regularly spaced cycloid shape test lines and particle boundaries observed in the total vertical projections, N0 is the total number of particles observed in the total vertical projection and the parameter beta is a characteristic of the measurement grid; it has units of reciprocal of length. The result is applicable to any arbitrary collection of convex particles; the particle orientations need not be isotropic. Only 'intersection counts' are required; it is not necessary to measure sizes of the particles in the projected images.

Journal Article↗