Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Mandibular Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Survival of various implant-supported prosthesis designs following 36 months of clinical function.

BACKGROUND: The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. METHODS: Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. RESULTS: Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. CONCLUSIONS: The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

Alloys↗

[Restoration of oral functions following a (partial) mandibulectomy due to an oral carcinoma].

For patients diagnosed with malignant oral lesions invading the mandible, a partial or complete mandibulectomy is unavoidable. In predicting the invasion of the lesion, preoperative imaging techniques are used, such as an orthopantomogram, computed tomography, and magnetic resonance imaging. A mandibular discontinuity can be restored using a stainless steel or titanium reconstruction plate, or using autogenous non-vascularized or vascularized bone grafts. In achieving the goal of complete rehabilitation endosseous permucosal implants can be inserted in order to support a prosthesis. There is a tendency of a higher implant loss frequency among bone-grafted patients who have had implants after irradiation when compared with non-irradiated patients. After a (partial) mandibulectomy, oromandibular reconstruction by non-vascularized or vascularized bone grafts and endosseous implants provides a unique opportunity to restore some oral functions.

Bone Transplantation↗

Permanent Proplast temporomandibular joint implants: MR imaging of destructive complications.

We studied the radiologic and pathologic changes in 30 patients (34 joints) in which there were locally destructive bone and soft-tissue complications associated with previously inserted permanent temporomandibular joint (TMJ) Proplast-Teflon implants. The cases were selected as representative examples of patients with failed Proplast interpositional arthroplasty, in whom images of the TMJ were obtained with conventional radiography, tomography, and MR, and in whom both surgical and histologic findings were available. Clinical indications for imaging included joint pain, restricted joint motion, crepitus, preauricular swelling, regional lymphadenopathy, malocclusion either acquired or changed since implant surgery, and facial deformity. Surgery was then performed for the purposes of implant retrieval and joint debridement because of destructive soft-tissue and osseous changes observed from the imaging analysis in conjunction with significant clinical signs and symptoms. The pathologic changes, observed 4-54 months after implant surgery, included a destructive foreign-body-type granuloma and avascular necrosis of the mandibular condyle and condylar neck. Our findings suggest that MR is useful in the detection and evaluation of destructive complications that may accompany failed Proplast-Teflon implants in the TMJ. MR is superior to conventional radiography and tomography in detecting soft-tissue lesions and avascular necrosis of bone. Tomography more accurately delineates soft-tissue calcifications and cortical margins of osseous structures.

Adult↗

Evaluation of temporomandibular joint prostheses: review of the literature from 1946 to 1994 and implications for future prosthesis designs.

PURPOSE: This article describes the useful elements of applied temporomandibular joint (TMJ) prostheses and discusses the factors necessary to be addressed in an appropriate TMJ prostheses design. MATERIALS AND METHODS: Information about TMJ prostheses was gathered by a literature search. Only designs with the primary intention of true joint replacement were selected. The designs were divided in fossa-eminence, condylar, and total joint replacements, which are reviewed separately. RESULTS: A fossa-eminence prosthesis can be fixed by a metal plate screwed to the root of the zygomatic arch. A condylar prosthesis can be fixed by a metal plate screwed to the mandibular ramus and fitted by bending the plate or using different sizes. All reviewed designs resulted in a loss of translational movements of the mandible, especially in an anterior direction. Although the recent designs use the same materials as are used in hip and knee joint prostheses, the wear properties of the existing TMJ prostheses are still unknown. CONCLUSIONS: A future prosthesis must imitate the anterior movement of the mandible when the mouth is opened and also allow some mediolateral movement. The fitting to the skull is still a major problem, as is the combination of the required motions and low wear rates. To confirm good clinical performance of a new TMJ prosthesis, long-term follow-up studies are necessary.

Evaluation Studies as Topic↗

The use of a rotational-path design for a mandibular removable partial denture.

The lack of display of anterior metal clasps is a primary advantage of the A-P rotational-path mandibular RPD design. A disadvantage of this design is that it relies on rigidmetal guiding plates for anterior retention and stability. Loss of retention may require procedures much more involved than the simple adjustment of conventional RPD clasps. Proper adherence to design, survey, fabrication, and adjustment procedures described by the authors should result in an esthetically pleasing and well-retained tooth-supported removable prosthesis. This article recommends the A-P rotational-path mandibular RPD as a treatment the clinician can use to restore multiple missing anterior teeth and satisfy a patient's financial, esthetic, and functional requirements.

Dental Clasps↗

Groningen temporomandibular joint prosthesis. Development and first clinical application.

Patients with a severely degenerated temporomandibular joint (TMJ) may benefit from an alloplastic TMJ replacement. The aim of the study was to develop a safe and properly functioning TMJ prosthesis. The design was based on imitation of anterior condylar translation by an inferiorly located centre of rotation, unrestricted mandibular movements by a double articulation, correct fit to the skull by a self-adjusting skull part consisting of two connected parts, and stable fixation by bone screws that are rigidly connected to the prosthesis parts. The prosthesis consists of a titanium skull part with ceramic inlay, a titanium mandibular part with a ceramic spherical head, and an intervening polyethylene disc. Titanium-alloy bone screws are used for fixation. All parts are available in a number of different shapes. In vitro laboratory and in vivo animal tests showed a low wear rate, the possibility of a close fit to the skull, a stable fixation, sufficient mechanical strength, appropriate choice of materials and proper functioning. Thereafter the step to first patient application was made. First patient application was carried out without adverse events. In conclusion, the presented TMJ prosthesis passed the pre-clinical tests and has progressed to clinical application. The fit to the skull, the expected lifetime of the device and the reliability of the implantation procedure require further evaluation in well-designed clinical trials.

Adult↗

Treatment of sleep apnea in congestive heart failure with a dental device: the effect on brain natriuretic peptide and quality of life.

The aim of the present study was to investigate the effect of a mandibular advancement device (MAD) for the treatment of sleep apnea (SA) on plasma brain natriuretic peptide (BNP), left ventricular ejection fraction (LVEF), and health-related qualify of life (HRQL) in patients with mild to moderate stable congestive heart failure (CHF). Seventeen male patients aged 68.4+/-5.5 with an apnea-hypopnea index (AHI) >or=10 were equipped with an individually fitted MAD. SA was evaluated using a portable respiratory multirecording system before and after the initiation of treatment. Eleven patients completed follow-up and were evaluated after 6 months of treatment. The AHI reduced from 25.4+/-10.3 to 16.5+/-10.0 (p=0.033) compared to baseline and mean plasma BNP levels decreased from 195.8+/-180.5 pg/ml to 148.1+/-139.9pg/ml (p=0.035). SA-related symptoms, e.g., excessive daytime sleepiness, were also reduced (p=0.003). LVEF and HRQL were unchanged. We conclude that SA treatment with a MAD on patients with mild to moderate stable CHF appears to result in the reduction of plasma BNP levels. Further studies to investigate if the observed reduction in BNP concentrations also result in improved prognosis are warranted.

Aged↗

Role of the general dentist in maxillofacial prosthetics.

Care of oral cancer patients requires the opinions and coordinated efforts of various consultants or therapists functioning as a multidisciplinary team to treat individual patients' physical, social, and economic problems. The modern medical concept of total treatment of the patient must include dentistry. Every dentist with interest and training in the basic principles of maxillofacial prosthetics can offer invaluable assistance in the treatment of maxillofacial patients.

Dentures↗

Massive osteolysis of the maxillofacial bones. Report of two cases.

Two cases of massive osteolysis were encountered, one affecting the mandible and the other the maxilla and mandible. Only 13 cases have been reported so far in the existing literature for massive osteolysis of the mandible. It is indeed a rare disease. Our two cases were surgically treated and were clinically and histopathologically assessed.

Aged↗

Hemophilic pseudotumor of the mandible. Report of a case.

Hemophilic pseudotumor of bone is a rarely encountered lesion associated with hemophilia. To date, only eight cases in the mandible have been reported in the literature. A rare case occurring in the mandible of a 2 1/2-year-old child required the fabrication of a customized wound obturator for postoperative wound care after surgical curettage. The literature is reviewed and the obturator described.

Child, Preschool↗

Evaluation of stability of titanium and hydroxyapatite-coated osseointegrated dental implants: a pilot study.

An endosseous implant is described as osseointegrated when it is immobile in function. Objective measures of stability testing have been described. The Periotest is a commercially available device that is used for this purpose. This study was designed to measure stability of endosseous implants placed in the mandible. Implants were placed in the mandibular canine or first premolar area to support an overdenture prosthesis. Stability was evaluated through the use of a Periotest device at the time of implant placement and following one year of functional loading. Implant designs were either a screw-shaped titanium alloy or a hydroxyapatite-coated cylinder. A total of 54 implants were placed, 37 were titanium screw-shaped implants, while the remaining 17 were hydroxyapatite cylinders. Initial measurements of stability showed no difference due to implant type. Following one year of functional loading, titanium screw-shaped implants were more stable than hydroxyapatite implants (P < 0.05). The difference in implant rigidity following a period of functional loading may be an indication of a difference in osseointegration between the two implants used in this study.

Aged↗

The role of a hospital-based dental implant center.

The role of a hospital-based implant center with dental and medical specialists working as a team is discussed. Advantages to the team include the availability of sophisticated hospital equipment and facilities. Referring dentists are encouraged to participate in and/or observe treatment performed at the implant center. Four cases treated by an implant team within a hospital environment are presented.

Adult↗