Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Automation, Laboratory”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

[Automated management of information in the microbiology department of a hospital analysis laboratory. Practical evaluations and operational proposals].

The computer has now an important role in analysis laboratory. Particularly the microbiological sector may receive a considerable support by the computer. In fact it's possible to form an effective epidemiologic hospital observatory, by making a systematic and continuous control of bacterial ecology in hospital wards, through the statistical results elaborated by computer. This is the object of the microbiological sector in the hospital's laboratory in Pistoia Town.

Electronic Data Processing↗

[50 years of clinical chemistry, first hand experience].

Approximately since 1945, progress in the field of photometric analysis also found its way into the laboratories of clinical chemistry. These techniques almost completely replaced the then prevailing gravimetric and titrimetric methods. At the same epoch, many of the biochemical reagents which up to then had to be prepared by the clinical laboratories themselves with great expenditure of work became commercially available. The increasing number of analytical orders could only be mastered thanks to the newly developed analyzers. Novel microliter techniques made it possible to diminish drastically the volumes of samples and reagents necessary. The radioimmunoassay opened up new analytical dimensions, the limits of detection and of quantification were expanded downwards to the picomol range. Soon afterwards, enzymes and/or fluorochromes were used as markers in immunoassays. The development of monoclonal antibodies constituted further important progress in this field. The latest revolutionary invention is doubtlessly the polymerase chain reaction (PCR), and related techniques. These methods are bound to bring about fundamental change not only in clinical chemistry but in the medical laboratory diagnostics in general.

Antibodies, Monoclonal↗

Comparison of a commercial enzymic kit for urinary oxalate analysis with a high performance liquid chromatographic method.

A new commercial enzymic kit for urinary oxalate determination has been adapted for use on a centrifugal analyser. It has been evaluated and compared with an established high performance liquid chromatographic (HPLC) procedure developed in our laboratory. Mean recovery of oxalate from urine samples augmented with oxalic acid exceeded 97% by both methods. The precision of the HPLC method was superior to that of the enzymic kit but both methods gave between batch precision values better than CV 12% at low (less than 100 mumol/L) oxalate concentrations and better than CV 7% at higher concentrations (greater than 270 mumol/L). Urinary oxalate values obtained with the new enzymic procedure correlated more closely with HPLC values (r = 0.84) than did values previously obtained using the forerunner of the kit (r = 0.62) which was known to be susceptible to ascorbate interference. No significant interference from ascorbic acid or from high urinary calcium concentrations could be demonstrated using either the improved kit or the HPLC procedure. Its easy adaptation to automated analysers available in most laboratories, coupled to its acceptable analytical performance render the enzymic kit a reasonable alternative to HPLC or other more complex procedures for urinary oxalate analysis.

Chromatography, High Pressure Liquid↗

Automation and validation of a fast method for the assessment of in vivo oxidative stress levels.

BACKGROUND: The d-ROMs test for the evaluation of serum hydroperoxides (HP) is simple, reliable, and cheap. Furthermore, it can easily be adapted to automated analyzers. Changing from the manual to an automated procedure allows the simultaneous processing of a large number of samples in a greatly reduced time, avoiding manual handling of samples and reagents and reducing variability sources. METHODS: This study was performed to adjust the manual procedure to a routine automated method in the clinical laboratory. We carried out the d-ROMs test in sera from 90 subjects of both sexes (34 men and 56 women) with age ranging from 20 to 80 years (mean 51+/-14 years). All subjects were free from acute or chronic inflammatory disease, immunological disease and history or evidence of malignancy. Subjects were not on vitamin and/or antioxidant therapies. RESULTS: The detection limit of the assay was 40 AU. Linearity was observed up to 475 AU. The recovery ranged between 97% and 105%. Within- and between-run imprecision was <5%. The mean HP value was 304+/-8 AU, with no significant difference between men (291+/-10 AU) and women (311+/-11 AU). A significant positive correlation was observed between age and HP in the whole population (r=0.4, p=0.0002). CONCLUSIONS: The automated test for the estimation of serum hydroperoxides represents a reliable and feasible procedure for increasing efficiency and reducing costs compared to the manual method, and is particularly suitable for evaluating oxidative stress in a variety of clinical conditions.

Adult↗

[Biological diagnosis of malaria: dangers of the automated blood differential count].

Automated differential counting systems deprive laboratories of blood smear study and so malaria risks not to be diagnosed if plasmodium search is not prescribed by the physician. Some abnormalities (atypical lymphocytes called LUC and thrombopenia) can induce a blood smear. But a study of 96 patients shows that, during the first analysis, these abnormalities can miss for nearly a third of one's case. So it is very important to prescribe malaria search on blood smears when there is the least clinical symptom.

Adult↗

Automated Speech-recognition Anatomic Pathology (ASAP) reporting.

Artificial intelligence speech-recognizers integrated with Laboratory information and Telefaxcommunication Systems have allowed for totally automated surgical pathology reporting. Automated Speech-Recognition Anatomic Pathology (ASAP) reporting improves the speed, text accuracy, comprehensiveness, and workflow management of diagnostic reports while eliminating support personnel. Healthcare reform goals of increased productivity and economy are furthered. Reports are rendered "as soon as possible" (ASAP) expediting appropriate clinical management and decreased length of stay and hospital costs.

Artificial Intelligence↗

The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

Cell Line↗

Computer-aided characterization of mammographic masses: accuracy of mass segmentation and its effects on characterization.

Mass segmentation is used as the first step in many computer-aided diagnosis (CAD) systems for classification of breast masses as malignant or benign. The goal of this paper was to study the accuracy of an automated mass segmentation method developed in our laboratory, and to investigate the effect of the segmentation stage on the overall classification accuracy. The automated segmentation method was quantitatively compared with manual segmentation by two expert radiologists (R1 and R2) using three similarity or distance measures on a data set of 100 masses. The area overlap measures between R1 and R2, the computer and R1, and the computer and R2 were 0.76 +/- 0.13, 0.74 +/- 0.11, and 0.74 +/- 0.13, respectively. The interobserver difference in these measures between the two radiologists was compared with the corresponding differences between the computer and the radiologists. Using three similarity measures and data from two radiologists, a total of six statistical tests were performed. The difference between the computer and the radiologist segmentation was significantly larger than the interobserver variability in only one test. Two sets of texture, morphological, and spiculation features, one based on the computer segmentation, and the other based on radiologist segmentation, were extracted from a data set of 249 films from 102 patients. A classifier based on stepwise feature selection and linear discriminant analysis was trained and tested using the two feature sets. The leave-one-case-out method was used for data sampling. For case-based classification, the area Az under the receiver operating characteristic (ROC) curve was 0.89 and 0.88 for the feature sets based on the radiologist segmentation and computer segmentation, respectively. The difference between the two ROC curves was not statistically significant.

Algorithms↗

[Traditional and innovative diagnostic tools: when and why they should be applied].

The development of new technological methods surely improves the quality of the Diagnostic Services in Parasitology offered to the National Sanitary Service, however, cost and simplicity have not to be neglected, even when the prime consideration is efficiency. Moreover, the mere fact that something can be done by one of these new approaches does not mean that it should be done that way or that it is most cost-effective to do it that way. A review of diagnostic tools in Parasitology is proposed, to evaluate when and why each of them should be applied. Traditional procedures for the diagnosis of parasitosis are only based on the "direct" recovery and recognition of the parasite, with the microscope as main tool and few other instruments as co-operator. The innovative procedures, recently adjusted on the basis of new scientific knowledge and made possible by the development of the laboratory instrument weapons, can evidence the parasites both directly and indirectly. If it is obvious that the direct identification of a pathogen is more reliable than that indirect, is not so evident what is the most useful direct method, and when it would be better to use indirect diagnostic tools. Advantages and disadvantages of each procedure, cost as well as the purpose of the test (diagnosis, post-treatment, research), and the general condition in which the test have to been applied must be taken into account when we are choosing. In general, we can say that the rationale for their use can be summarised as follows: 1) The macroscopic/microscopic analysis of samples is always recommended (with the exception of samples coming from tissues that need surgery). This "old" procedure allows the identification in 20 minutes of all the parasites present in mixed infections, and the evaluation of the parasite load. It is a cost-effective method which relies ultimately on the skill of the observer to detect and identify parasite stages; 2) Parasite antigen detection is an innovative and expensive immunological diagnostic, which can suffer of sensitivity and specificity. It could be useful to directly diagnose "occult" infections; 3) Parasite DNA/RNA direct detection is an innovative, sensitive and specific procedure, which can also identify sibling species. It is expensive, therefore its use is restricted to reference laboratories; 4) Host antibody detection is an innovative indirect tool to evaluate the presence of a parasite by means the evaluation of the host response to infection. It can suffer of sensitivity and specificity, and the interpretation of the test results may be difficult. It could be applied as first step to evaluate the presence of tissue parasites, whose direct diagnosis would require surgery. Some tests can be performed in well-equipped laboratories; other tests are available through research laboratories. The specimens, appropriately collected and preserved, have always to be processed in security for potential risk of infection hazard, and submitted to tests appropriate to the laboratory's goals, where, therefore, field and research diagnostic tools shouldn't be applied. The test selected for routine use has to be chosen taking into account value and limitations of each method. Reduction in excessive and often unnecessary testing is mandatory, and therefore it is critical for the clinical Parasitology to perform relevant testing while maintaining appropriate quality. To date, the microscopic analysis of samples is the only direct method that allows all identifications in short times, at a reduced cost, independently from geographical origin and peculiar status of the patient. It has to be regarded as the first step in diagnostic procedures for all laboratories. Some molecular techniques have greater sensitivity than traditional methods, but at least at the present time, their costs may well preclude their routine use. It is difficult to know, exactly, where diagnostic Parasitology will be moving in the next few years, although many soothsayers feel very strongly that the area of molecular diagnostics will replace more traditional means. It is also possible that immunological or perhaps cytometric procedures will replace our more standard diagnostic approach; nevertheless they will continue to remain oddities on the outside of the general practice and be confined to a few reference laboratories. As far as semi-automated or automated instruments and robotics-based techniques, they are useful when large numbers of the same test are performed. Supposing that they will enter in our laboratory, that will happen in central facility rather than in each local facility. So, the great interest in using new technological methods to solve old problems probably will have to be seen in the right perspective.

Animals↗

Biological rhythms of biochemical serum parameters in a Brazilian population: a three-year study.

A marked decrease in analytical and post-analytical variability has been achieved in clinical laboratories by the use of automated analytical systems. Current studies are now focused on the origin of pre-analytical variability, such as that due to intra-individual differences and biological rhythms. The objective of this work was to evaluate the occurrence of biological rhythms in several biochemical serum parameters in a Brazilian population. A retrospective study (1996 to 1998) was carried out to collect the test results within the reference intervals of adults, from 21 to 50 yr of age (average age of 36 yr) attending the outpatient clinics of the Teaching Hospital at the University of Campinas, São Paulo, Brazil. The reference sample was 52.9% male and 47.1% female and encompassed 15,036 calcium, 7,478 phosphorus, 53,641 urea, 58,315 creatinine and 6,433 uric acid determinations (140,903 in total). Significant annual rhythms were detected in serum calcium (p<or=0.001), with maximum and minimum values in fall and spring, and in serum creatinine (p<or=0.002), with maximum and minimum values in summer and winter. The other parameters did not present significant annual rhythmicity. The seasonal rhythms present in the serum concentrations of calcium and creatinine observed in this large population study, although of small amplitude, should be considered a component of the pre-analytical variation of these clinical laboratory tests.

Adult↗

A rapid assay for ristocetin cofactor activity using an automated coagulometer (ACL 9000).

We have set up a rapid assay for measuring the activity of the von Willebrand factor ristocetin cofactor (VWF : RCo) using an automated coagulometer (ACL 9000; Instrumentation Laboratory, Lexington, Massachusetts, USA) and commercially available lyophilized platelet reagents (Dade-Behring, Marburg, Germany). Since VWF : RCo tested with the coagulometer (ACL-VWF : RCo) did not require loading, calculation of von Willebrand factor (VWF) activity or pretreatment of samples (calibration standard and tested plasmas), we thought it might be useful for rapid, automatic screening of VWF activity. To assess the precision and the potency of this ACL-VWF : RCo, we tested the assay in this laboratory's internal normal and abnormal controls, in a group of 67 healthy individuals and in 28 patients with different types of von Willebrand disease (VWD). We compared the ACL-VWF : RCo findings with those of the standard agglutination test (Agg-VWF : RCo), normalizing both assays against VWF antigen (VWF : Ag) measured by 'automatic' and standard enzyme-linked immunosorbent assay 'in-house' methods, to calculate the VWF : RCo/VWF Ag ratios. The within-assay and between-assay repeatability of the automatic ACL-VWF : RCo gave coefficients of variation < 5%, and reproducibility in normal and abnormal laboratory controls gave coefficients of variation of 7.9 and 9.3%, respectively. In VWD patients the results were equivalent to those of the standard Agg-VWF : RCo assay but, because of the good sensitivity, the ACL-VWF : RCo was more accurate in evaluating the VWF : RCo and establishing the VWF : RCo/VWF : Ag ratios in VWD patients with low VWF levels. Moreover, this ACL-VWF : RCo is faster than Agg-VWF : RCo, providing results of calibration curves and of 10 patient samples within 15 min. We can conclude that this automatic ACL-VWF : RCo gives a reliable and useful measure of VWF activity and can be proposed as a screening test for rapid diagnosis of VWD even in patients with low VWF levels in plasma.

Antigens↗

Flow cytometric immunodetection of human immunodeficiency virus type 1 proviral DNA by heminested PCR and digoxigenin-labeled probes.

PCR is the most sensitive and direct method for detecting blood-borne viruses, as well as an efficient means for producing vector-free probes. However, the application of PCR, especially in the laboratory diagnosis of human immunodeficiency virus (HIV) infection, is impeded by the current use of radiolabeled oligonucleotide probes. Therefore, we have developed a nonisotopic PCR immunoreactive bead (PCR-IRB) assay to detect HIV type 1 proviral DNA from peripheral blood mononuclear cells (PBMC). We used a biotinylated primer in a set of three oligonucleotides selected from the HIV long terminal repeat region for heminested PCR amplification. An internal probe was synthesized by PCR with incorporation of digoxigenin-labeled dUTP. After solution hybridization of the probe with PCR-amplified products (amplicons), the hybridized DNA was captured with streptavidin-coated magnetic beads. For the detection of hybrids, flow cytometric analyses were carried out by two procedures: (i) direct detection with fluorescein isothiocyanate (FITC)-labeled antidigoxigenin immunoglobulin G (IgG) antibody and (ii) indirect detection with antidigoxigenin sheep IgG antibody followed by FITC-labeled anti-sheep IgG antibody. Both procedures in the PCR-IRB assay detected two to three copies of HIV proviral DNA sequences, a sensitivity that is comparable with that of the conventional radioactive detection of amplicons following probe hybridization and electrophoresis. To compare the PCR-IRB assay with the conventional method, we tested 53 pedigreed PBMC specimens from blood donors and newborns; the results obtained were identical. This nonisotopic PCR-IRB assay can also be automated for potential application in laboratory diagnosis of HIV infection, blood bank screening, and therapeutic monitoring of viremia and perinatal transmission.

Base Sequence↗

Advanced oxidation protein products (AOPP) for monitoring oxidative stress in critically ill patients: a simple, fast and inexpensive automated technique.

Oxidative stress is known to be involved in many human pathological processes. Although there are numerous methods available for the assessment of oxidative stress, most of them are still not easily applicable in a routine clinical laboratory due to the complex methodology and/or lack of automation. In research into human oxidative stress, the simplification and automation of techniques represent a key issue from a laboratory point of view at present. In 1996 a novel oxidative stress biomarker, referred to as advanced oxidation protein products (AOPP), was detected in the plasma of chronic uremic patients. Here we describe in detail an automated version of the originally published microplate-based technique that we adapted for a Cobas Mira Plus clinical chemistry analyzer. AOPP reference values were measured in plasma samples from 266 apparently healthy volunteers (university students; 81 male and 185 female subjects) with a mean age of 21.3 years (range 18-33). Over a period of 18 months we determined AOPP concentrations in more than 300 patients in our department. Our experiences appear to demonstrate that this technique is especially suitable for monitoring oxidative stress in critically ill patients (sepsis, reperfusion injury, heart failure) even at daily intervals, since AOPP exhibited rapid responses in both directions. We believe that the well-established relationship between AOPP response and induced damage makes this simple, fast and inexpensive automated technique applicable in daily routine laboratory practice for assessing and monitoring oxidative stress in critically ill or other patients.

Adolescent↗

Implications of mass automated instruments on medical practice.

The clinical laboratory is in a stage of change which has been the direct result of an influx of technology and the current demand for lower costs and increased productivity. There is no significant trend anticipated in the future which would forestall this particular process. The practicing physician can anticipate a fairly marked reduction in the cost of individual tests and, likewise, a marked increase in the amount of available information. There will be a larger clerical function involved in the review of such information along with a series of relevant problems related to the actual size of the new data base. One of the most significant problems related to this increase in numerical reporting will be the statistical problem of the "abnormal-normal." Statistical misclassification must be considered with each abnormal test and a specific approach must be taken to these tests to minimize the inconvenience to the patient. It is recommended that any unsuspected abnormal test(s) that is discovered be repeated as a single test(s) through a reference method. Reordering of the test battery or screen will only offer another possibility for statistical misinterpretation. If the test on isolated evaluation does appear abnormal, then this should call for the routine evaluation of this particular condition. Multivariate statistical analysis could eliminate this probability dilemma, yet is presently experimental and is not in routine use within any clinical setting. We can look forward to the evolution of such a process through the mechanism of a hospital and laboratory communication system which will allow the physician to work with an evaluation process capable of handling these large volumes of numbers (22). Such programs are on the horizon and should be anticipated within the next five years in some of the larger centers that have this new instrumentation.

Analysis of Variance↗

Performance characteristics of an automated high-sensitivity C-reactive protein assay on the Dimension RXL analyzer.

BACKGROUND: C-reactive protein (CRP) is a nonspecific marker of inflammation that can be used as a marker for atherosclerotic risk. This application requires increased precision at low CRP concentrations compared to traditional assays. METHODS: The Dimension RXL is an automated chemistry analyzer for central laboratory use. The limit of detection, limit of quantification, linearity and imprecision of a high-sensitivity CRP assay developed for it were assessed. Method comparison studies were performed using samples both inside and outside the reference interval. The presence of a prozone effect was also evaluated. RESULTS: The limit of detection was 0.7 mg/l. The method was linear from 2 to 60 mg/l and from 1 to 60 mg/l using systematic error limits of 10% and 20%, respectively. The total imprecision was <10% for CRP concentrations above 1.5 mg/l. No prozone effect was seen at a CRP concentration of 450 mg/l, the highest concentration tested. Using samples from 212 apparently healthy adults, the Dimension RXL method demonstrated good concordance with the BN II high-sensitivity CRP method for samples in the highest quartile. It also compared well using samples with elevated CRP concentrations. CONCLUSIONS: The Dimension RXL high-sensitivity CRP method may be adequate for atherosclerotic risk prediction in clinical practice if accurate and precise measurement is only required for the highest quartile. However, the total error of this method for CRP concentrations <3 mg/l appears too large for accurate assignment to lower risk groups.

Adult↗

The cost of laboratory technology: a framework for cost management.

Laboratory costs at Vancouver General Hospital have been increasing over the past decade. Of the numerous explanations that have been offered for these increases, one contributing factor is the impact of automation and technology. An aggregate measure of laboratory technology was constructed and the net contribution to cost per acute care admission was estimated. Technology has two counteracting effects: It stimulates demand for tests, thus increasing cost per acute care admission, and it increases productivity, thus reducing costs. Effective management may be able to achieve the cost reductions without incurring an increased demand.

Automation↗

Detection of Chlamydia trachomatis in genitourinary tract specimens using an automated enzyme-linked fluorescent immunoassay.

BACKGROUND AND GOAL: The VIDAS Enzyme Linked Fluorescent Assay is a fully automated assay for the detection of Chlamydia trachomatis in clinical specimens. Because there is an increasing demand for automated assays for large volume laboratories and there is little performance data available, the authors evaluated the performance of the VIDAS enzyme linked fluorescent assay by comparing it with Chlamydiazyme and polymerase chain reaction. STUDY DESIGN: Endocervical swabs from 330 women attending a hospital based obstetrics/gynecology clinic and 100 first void urine specimens from males attending a sexually transmitted disease clinic were tested by enzyme linked fluorescent assay, Chlamydiazyme, and polymerase chain reaction. RESULTS: Fourteen of 330 endocervical specimens and 14 of 100 first void urine specimens were positive by Chlamydiazyme. Enzyme linked fluorescent assay detected 12 of 14 endocervical and 11 of 14 first void urine specimens. Compared with Chlamydiazyme, enzyme linked fluorescent assay had a sensitivity of 85.7% (12 of 14) for endocervical swabs and 76.9% (11 of 14) for first void urine specimens. Polymerase chain reaction detected an additional five endocervical and two first void urine specimens that had negative results by both enzyme linked fluorescent assay and Chlamydiazyme. All 7 were confirmed positive by polymerase chain reaction using a second primer set. Using an expanded gold standard of blocked Chlamydiazyme and confirmed polymerase chain reaction, enzyme linked fluorescent assay had a sensitivity of 63.2% (12 of 19) for endocervical swabs and 68.8% (11 of 16) for first void urine specimens compared with 73.7% (14 of 19) and 87.5% (14 of 16) for Chlamydiazyme. Polymerase chain reaction had a sensitivity of 100% (19 of 19) and 93.8% (15 of 16) for endocervical swabs and first void urine specimens, respectively. The specificity of enzyme linked fluorescent assay and Chlamydiazyme was 100%. CONCLUSIONS: The VIDAS enzyme linked fluorescent assay for the detection of Chlamydia trachomatis in genitourinary specimens is highly specific but is not sufficiently sensitive for use as a routine diagnostic test.

Automation↗