Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

A systematic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway.

The original and modified Mallampati tests are commonly used to predict the difficult airway, but there is controversy regarding their accuracy. We searched MEDLINE and other databases for prospective studies of patients undergoing general anesthesia in which the results of a preoperative Mallampati test were compared with the subsequent rate of difficult airway (difficult laryngoscopy, difficult intubation, or difficult ventilation as reference tests). Forty-two studies enrolling 34,513 patients were included. The definitions of the reference tests varied widely. For predicting difficult laryngoscopy, both versions of the Mallampati test had good accuracy (area under the summary receiver operating characteristic (sROC) curve = 0.89 +/- 0.05 and 0.78 +/- 0.05, respectively). For predicting difficult intubation, the modified Mallampati test had good accuracy (area under the sROC curve = 0.83 +/- 0.03) whereas the original Mallampati test was poor (area under the sROC curve = 0.58 +/- 0.12). The Mallampati tests were poor at identifying difficult mask ventilation. Publication bias was not detected. Used alone, the Mallampati tests have limited accuracy for predicting the difficult airway and thus are not useful screening tests.

Anesthesia, General↗

Ranging accuracy test of the sonic microstereometric system.

We have recently introduced a new type of ultrasonic-based, three-dimensional ranging system for the localization of small handheld surgical tools to be used during operation in open stereotactic brain surgery. This targeting system has now been extensively laboratory tested during thousands of measuring cycles with a CNC-based measuring table. The typical accuracy found in a single direction was 0.4 mm and better. The accuracy vector in space was 0.897 mm (n = 2312). The test-retest accuracy was typically 0.4 mm. With the given accuracy, the system is suitable for all ranging tasks in open stereotactically guided microsurgery.

Brain Diseases↗

Accuracy of the combination of mammography and sonography in predicting tumor response in breast cancer patients after neoadjuvant chemotherapy.

BACKGROUND: Residual tumor size after neoadjuvant chemotherapy is an important consideration in surgical planning. We examined the accuracy of the combination of mammography and sonography in predicting pathologic residual tumor size. METHODS: Tumor size was evaluated by physical examination, mammography, and sonography at diagnosis and before surgery in 162 breast cancer patients who received neoadjuvant chemotherapy. Agreement between the predicted and the pathologic responses and the predicted and the pathologic tumor sizes was calculated. The effect of invasive lobular carcinoma, high nuclear grade, hormone receptor positivity, and the presence of an extensive intraductal component on the accuracy of mammography and sonography in predicting pathologic residual tumor size was analyzed. RESULTS: Forty-two patients (25.9%) had a pathologic complete response (pCR). Overall agreement between predicted and pathologic responses was 53% for physical examination, 67% for mammography plus sonography, and 63% for physical examination plus mammography and sonography. The sensitivity of mammography and sonography in predicting pCR was 78.6%, and the specificity was 92.5%; the accuracy was 88.9%. Residual tumor size determined by mammography and sonography correlated with pathologic residual tumor size (r = .662); pathologic tumor size was within .5 cm of predicted in 69.1% of patients. Multivariate analysis showed that pathologic residual tumor size was underestimated for lobular carcinoma and overestimated for poorly differentiated tumors. CONCLUSIONS: The combination of mammography and sonography has a high accuracy in predicting pCR after neoadjuvant chemotherapy. Agreement of residual tumor size in mammography and sonography with pathologic residual tumor size was moderate.

Adult↗

Accuracy of SRM and power tap power monitoring systems for bicycling.

PURPOSE: : Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. METHODS: : First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21 degrees C) and time (1 h at ~300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. RESULTS: : The mean error scores for SRM and PT factory calibration over a range of 50 - 1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however, power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. CONCLUSIONS: : When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.

Australia↗

Estimation of dietary nutritional content using an online system with ability to assess the dieticians' accuracy.

We developed an online system for estimating dietary nutritional content. It also had the function of assessing the accuracy of the participating dieticians and ranking their performance. People who wished to have their meal estimated (i.e. clients) submitted images of their meal taken by digital camera to the server via the Internet, and dieticians estimated the nutritional content (i.e. calorie and protein content). The system assessed the accuracy of the dieticians and if it was satisfactory, the results were sent to the client. Clients received details of the calorie and protein content of their meals within 24 h by email. A total of 93 dieticians (71 students and 22 licensed practitioners) used the system. A two-way analysis of variance showed that there was a significant variation (P=0.004) among dieticians in their ability to estimate both calorie and protein content. There was a significant difference in values of both calorie (P=0.02) and protein (P<0.001) estimation accuracy between student dieticians and licensed dieticians. The estimation accuracy of the licensed nutritionists was 85% (SD 10) for calorie content and 78% (SD 17) for protein content.

Dietary Proteins↗

Factors determining the diagnostic accuracy of digitized conventional intraoral radiographs.

A number of factors may determine the diagnostic accuracy of digitized intraoral radiographs. Conventional film radiographs were digitized with three different digitizers, a laser-scanner, a drum-scanner and a TV camera. Digital images, varying in pixel size, grey level and image processing, were displayed on three different video-monitors and assessed by 10 dentists. The detectability of incipient proximal surface caries was used as an index of the diagnostic accuracy and the effect of the different factors compared by means of receiver operating characteristic (ROC) analysis. Images digitized by the drum-scanner were found to have the best diagnostic accuracy. Sufficient diagnostic accuracy could be attained on the low-cost video monitor of a personal computer. Digital images with a pixel size of 100 microns and 32 grey levels were found to be acceptable for intraoral radiographs for diagnostic purposes. These results provide a practical guide for establishing a digital image acquiring system for any intraoral radiographs, reducing demands on data storage to a minimum.

Analysis of Variance↗

Accuracy of dimensional and angular measurements from panoramic and lateral oblique radiographs.

OBJECTIVES: Dimensional and angular measurements from radiographs can be used in clinical dentistry to determine the inclination of impacted teeth, the relative position of roots and restorative abutments, and for implant site assessment. This study was carried out to assess the in-vitro accuracy of such measurements obtained from three rotational panoramic systems and two standardized lateral oblique projections (45 degrees and 60 degrees) using two cephalometric systems. METHODS: Acrylic test models with wires positioned to represent the position and angulations of the teeth were used. Ten images were taken with Oralix Pan DC/1, Panelipse and Orthophos panoramic machines. Fourteen lateral oblique radiographs were also taken using two cephalometric units: an Orthophos and a Quint Sectograph. The models were repositioned between each exposure. Horizontal, vertical and angular dimensions of every tooth position on each radiograph were measured by three evaluators and compared using ANOVA at an a priori significance level of alpha = 0.05. RESULTS: Assessment of vertical dimensions was consistently more accurate on lateral oblique projections than on the panoramic radiographs. In general, the most accurate horizontal measurements could also be made with the lateral oblique projections. No differences in angular measurement accuracy were found between any of the projections. The use of statistical means and standard deviations can be misleading in ranking accuracy where a consistent conversion factor can be applied. CONCLUSIONS: While panoramic radiography is convenient for dimensional and angular assessments, lateral oblique radiographs taken with a standard cephalometric apparatus are an alternative when greater clinical accuracy is needed.

Analysis of Variance↗

Accuracy of three-dimensional measurements using cone-beam CT.

OBJECTIVES: Lesions causing intraosseous defects in the head and neck region are difficult to diagnose using two-dimensional radiography, and three-dimensional (3D) data provided by CT is useful but often difficult to obtain. Recently, cone-beam CT (CBCT) was made available, with the potential to become a practical tool in dentistry. However, there is limited evidence to prove that defect volume can be determined accurately. Therefore, this in vitro validation study aimed at establishing whether linear and 3D CBCT, using volumetric measurements, is accurate for determining osseous defect sizes. METHODS: Depth and diameter of simulated bone defects in (i) an acrylic block and (ii) a human mandible were blindly measured electronically by five examiners using CBCT. Linear measurements were compared with predetermined machined dimensions. Using software, volume extraction was performed by another examiner on the acrylic phantom and compared with known dimensions. Data were analysed using paired t-tests. RESULTS: Using the acrylic block, mean width accuracy was -0.01 mm (+/- 0.02 SE) and mean height difference was -0.03 mm (+/- 0.01 SE; P > 0.05). For the human mandible, mean width accuracy was -0.07 mm (+/- 0.02 SE) and mean height accuracy was -0.27 mm (+/- 0.02 SE; P < 0.01). Volume accuracy was -6.9 mm3 (+/- 4 SE) for automated calculations and -2.3 mm3 (+/- 2.6 SE) for the manual measurements (P < 0.001). CONCLUSIONS: CBCT has the potential to be an accurate, non-invasive, practical method to reliably determine osseous lesion size and volume. Further clinical validation will lead to a vast array of applications in oral and maxillofacial diagnosis.

Acrylic Resins↗

Comparing the accuracy of panoramic and intraoral radiography in the diagnosis of proximal caries.

OBJECTIVES: The purpose of this study was to compare the diagnostic accuracy of panoramic and intraoral radiographic surveys in the diagnosis of proximal caries according to the different dental regions (maxillary and mandibular incisor, canine, premolar and molar). METHODS: In this study, full mouth series and panoramic radiographs of 79 patients were used. The radiographs were evaluated for proximal caries by three observers. The diagnostic accuracy of radiographic surveys for each dental region was assessed by means of receiver operating characteristic (ROC) curve analysis. RESULTS: Full mouth series was the most efficient method in the diagnosis of caries for incisor and canine teeth. However, full mouth series and combination of panoramic plus bitewings had similar diagnostic accuracy for premolar and molar teeth. CONCLUSIONS: Panoramic survey alone was not sufficient for the diagnosis of proximal caries for the entire dentition. The combination of panoramic plus bitewing plus anterior periapical survey exhibited a diagnostic accuracy for proximal caries that was comparable with full mouth series.

Dental Caries↗

[Comparison of diagnostic accuracy of (18)F-FDG PET, (123)I-IMT- and (99m)Tc-MIBI SPECT: evaluation of tumour progression in irradiated low grade astrocytomas].

AIM: To evaluates the diagnostic accuracy of the SPECT-tracers 3-(123)I-alpha-methyl-L-tyrosine (IMT) and (99m)Tc(I)- hexakis(2-methoxyisobutylisonitrile) (MIBI) as well as the PET-tracer 2-(18)F-2-deoxyglucose (FDG) for detecting tumour progression in irradiated low grade astrocytomas (LGA). PATIENTS, METHODS: We examined 91 patients (56 males; 35 females; 44.7 +/- 11.5 years), initially suffering from histologically proven LGAs (mean WHO grade II) and treated by stereotactic radiotherapy (59.0 +/- 4.6 Gy). On average 21.9 +/- 11.2 months after radiotherapy, patients presented new Gd-DTPA enhancing lesions on MRI, which did not allow a differentiation between progressive tumour (PT) and non-PT (nPT) at this point of time. PET scans (n = 82) were acquired 45 min after injection of 208 +/- 32 MBq FDG. SPECT scans started 10 min after injection of 269 +/- 73 MBq IMT (n = 68) and 15 min after injection of 706 +/- 63 MBq MIBI (n = 34). Lesions were classified as PT and nPT based on prospective follow-up (clinically, MRI) for 17.2 +/- 9.9 months after PET/SPECT. Lesion-to-normal ratios (L/N) were calculated using contra lateraly mirrored reference regions for the SPECT examinations and reference regions in the contra lateral grey (GM) and white matter (WM) for FDG PET. Ratios were evaluated by Receiver Operating Characteristic (ROC) analysis. RESULTS: In the patient groups nPT and PT, L/N ratios for FDG (GS) were 0.6 +/- 0.3 vs. 1.2 +/- 0.5 (p = 0.003), for FDG (WS) 1.2 +/- 0.4 vs. 2.6 +/- 0.4 (p < 0.001), for IMT 1.1 +/- 0.1 vs. 1.8 +/- 0.4 (p < 0.001) and for MIBI 1.6 +/- 0.7 vs. 2.6 +/- 2.2 (p = 0.554). Areas under the non-parametric ROC-curves were: 0.738 +/- 0.059 for FDG (GS), 0.790 +/- 0.057 for FDG (WS), 0.937 +/- 0.037 for IMT and 0.564 +/- 0.105 for MIBI. CONCLUSION: MIBI-SPECT examinations resulted in a low accuracy and especially in a poor sensitivity even at modest specificity values. A satisfying diagnostic accuracy was reached with FDG PET. Using WM as reference region for FDG PET, a slightly higher AUC as compared to GM was calculated. IMT yielded the best ROC characteristics and the highest diagnostic accuracy for differentiating between PT and nPT in irradiated LGA.

Adult↗

Effect of clinical history on diagnostic accuracy in the cytologic interpretation of bronchial brush specimens.

There has been little study of the effect of clinical history on pathologic diagnostic accuracy. Five pathologists retrospectively examined 97 bronchial brush specimens with and without clinical historic information. Forty-nine patients had a biopsy-proven malignant lesion, and 48 had a benign lesion. Diagnostic accuracy with and without history for each pathologist was determined with likelihood ratios and receiver operating characteristic curves. The overall diagnostic accuracy with and without history was 0.84 and 0.76, respectively. The average negative predictive value of a benign diagnosis decreased from 89.2% (with history) to 74.0% (without history). Overall, the cytopathologists were more reluctant to make a definitive malignant diagnosis without history compared with history. The average positive predictive value of a malignant diagnosis with and without history was almost identical. The absence of history leads to lower diagnostic accuracy in the cytologic interpretation of bronchial brush specimens partly because pathologists underdiagnose malignant lesions.

Bronchi↗

Accuracy, clinical correlation, and patient acceptance of two handheld prothrombin time monitoring devices in the ambulatory setting.

OBJECTIVE: To evaluate the accuracy, clinical correlation, ease of use, and patient acceptance of the Coaguchek and the ProTime Microcoagulation System as compared with standard laboratory methods for prothrombin time determination. METHODS: A total of 30 prothrombin times, expressed as international normalized ratios (INRs), were determined by each handheld device for comparison with standard laboratory testing. Accuracy was evaluated by calculating the absolute difference for each pair of INR values. Clinical correlation was defined as an INR obtained by the handheld monitor that would have resulted in the same therapeutic decision as the INR obtained by the standard laboratory method. Subjects were surveyed to determine which method of INR determination they preferred and their reasons for that preference. RESULTS: Accuracy was superior with the Coaguchek monitor. The absolute difference (mean +/- SD) in the laboratory and Coaguchek INRs was 0.28+/-0.23 (p = 0.96). The absolute difference (mean +/- SD) in the laboratory and the ProTime Microcoagulation System INRs was 0.56+/-0.34 (p < 0.001). For clinical correlation, two out of 24 (8.3%) INRs with the Coaguchek were sufficiently different from the laboratory INR to have resulted in a different therapeutic decision, compared with 12 out of 24 (50%) with the ProTime Microcoagulation System (p < 0.005). Of subjects surveyed, 77.8% preferred the finger stick method. CONCLUSIONS: The Coaguchek was superior to the ProTime Microcoagulation System in accuracy, clinical correlation, and ease of use. The study also showed that patients preferred capillary blood sampling by finger puncture over venipuncture for INR monitoring.

Anticoagulants↗

Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT).

UNLABELLED: pQCT was evaluated for accuracy of phenotypic characterization of mouse bone in vivo. Bones (tibia, femur, spine) of 27 animals were measured ex vivo with pQCT, microCT, and histomorphometry and of 23 mice in vivo (pQCT). pQCT yielded satisfactory in vivo precision and accuracy in skeletal characterization. INTRODUCTION: Important aspects of modern skeletal research depend on the phenotypic characterization of genetically manipulated mice, with some approaches requiring in vivo measurement. Peripheral quantitative computed tomography (pQCT) is applicable in vivo and provides opportunities to determine a large variety of bone parameters. Here we test the ex vivo and in vivo reproducibility of pQCT, and its accuracy in comparison with histomorphometry and microcomputed tomography (microCT). MATERIALS AND METHODS: We examined the tibia, femur, and lumbar spine of 27 mice ex vivo with high-resolution pQCT, using two mouse models (wild-type and ob/ob) with known differences in bone density. Measurements were repeated three times at different days in nine animals. In a second experiment, 23 animals (10 wild-type and 13 bGH transgenic mice) were repeatedly measured in vivo at 12 and 13 weeks of age, respectively. RESULTS: Among metaphyseal sites, the ex vivo precision was highest at the distal femur (RMS CV < 1% for density and < 2% for area). The correlation between density (pQCT) and bone volume fraction (histomorphometry) was r2 = 0.79 (tibia, femur, and spine), and that with microCT was r2 = 0.94 (femur). At the diaphysis, the precision was highest at the femur (< 2% for total and cortical area), and the correlation with microCT was r2 > 0.77. The in vivo precision for bone density (distal femur) was 2.3-5.1%, and that for absolute and relative cortical area (tibia) was 3.1% and 2.2%. CONCLUSIONS: The results show that pQCT can yield satisfactory precision and accuracy in skeletal characterization of mouse bones, if properly applied. The potential advantage of pQCT is that it provides a large set of parameters on bone properties and that it can be used in vivo, extending the available methodological repertoire for genetic studies.

Animals↗

Condom use and the accuracy of AIDS knowledge in Côte d'Ivoire.

CONTEXT: Condom use remains low in Côte d'Ivoire, despite an increasing prevalence of HIV and widespread awareness of how the virus is transmitted. Information is needed about characteristics that predict condom use and about the role of AIDS knowledge and sex differences in the use of condoms. METHODS: Data from the 1994 Côte d'Ivoire Demographic and Health Survey were analyzed for respondents who had had sex in the two months before the survey. Logistic regressions were performed separately by sex to determine whether the accuracy of men's and women's knowledge about AIDS predicted condom use at their most recent sexual intercourse. RESULTS: Accuracy of knowledge about AIDS did not significantly predict condom use. For male respondents, the odds of condom use at last intercourse were significantly lower among those aged 35 or older than among those aged 15-19 (odds ratios, 0.3-0.5). The odds were also lower among married men (0.4) and those who reported friends, family or neighbors as their only source of AIDS knowledge (0.5). Compared with uneducated men, men with secondary or higher education were significantly more likely to report condom use (1.7). Among women, those aged 25 or older had significantly lower odds of condom use at last intercourse than those aged 15-19 (0.2-0.6). The odds of use were significantly reduced among women who were married (0.2) and those who had learned about AIDS from family, friends or neighbors or from television or radio (0.3-0.6); however, the odds were significantly higher for women with secondary or higher education than for uneducated women (2.2). CONCLUSION: The level of accuracy of AIDS knowledge did not predict the likelihood of recent condom use in this sample. Efforts to increase educational attainment in Côte d'Ivoire may be more effective in increasing condom use than a focus on improving the accuracy of AIDS knowledge.

Acquired Immunodeficiency Syndrome↗

Gated viewing and high-accuracy three-dimensional laser radar.

We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1-mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast technique of 3-D imaging. The system uses a picosecond Q-switched Nd:Yag laser at 532 nm with a 32-kHz pulse repetition frequency (PRF), which triggers an ultrafast camera with a highly sensitive CCD with 582 x 752 pixels. The high range accuracy is achieved with narrow laser pulse widths of approximately 200 ps, a high PRF of 32 kHz, and a high-speed camera with gate times down to 200 ps and delay steps down to 100 ps. The electronics and the software also allow for gated viewing with automatic gain control versus range, whereby foreground backscatter can be suppressed. We describe our technique for the rapid production of high-accuracy 3-D images, derive performance characteristics, and outline future improvements.

Journal Article↗

Discordance analysis characteristics as a new method to compare the diagnostic accuracy of tests: example of complexed versus total prostate-specific antigen.

BACKGROUND: ROC curve analysis is used to compare the overall diagnostic accuracy of tests, but its application to subgroups selected by a concentration range of only one marker may show severe biases. We developed a new approach, which we have named discordance analysis characteristics (DAC). METHODS: The DAC method is based on a generalization of the McNemar test so that for a given pair of cutoff values only those patients are analyzed who are categorized differently by the two tests compared. The analyses are performed for all cutoff pairs that deliver identical sensitivities for both tests. We used data for total (tPSA) and complexed prostate-specific antigen (cPSA) from a recently published multicenter study to demonstrate the DAC method. RESULTS: The example shows that ROC analyses of subgroups can give contradictory results about the diagnostic accuracy of two markers, depending on the marker used for the selection of subgroups. The DAC method avoids artifacts attributable to questionable selection of subgroups and facilitates overall and local comparisons of the diagnostic accuracy of tests. The DAC results of the analyzed data set suggest that cPSA has higher diagnostic accuracy than does tPSA. CONCLUSIONS: The DAC method is a suitable tool for comparing the clinical usefulness of laboratory markers. The DAC method could be considered as an additional tool to ROC analysis and could replace comparative ROC analyses of diagnostic tests, especially within subgroups defined by only one of the markers.

Humans↗

Impact of adjustment for quality on results of metaanalyses of diagnostic accuracy.

BACKGROUND: We examined whether and to what extent different strategies of defining and incorporating quality of included studies affect the results of metaanalyses of diagnostic accuracy. METHODS: We evaluated the methodological quality of 487 diagnostic-accuracy studies in 30 systematic reviews with the QUADAS (Quality Assessment of Diagnostic-Accuracy Studies) checklist. We applied 3 strategies that varied both in the definition of quality and in the statistical approach to incorporate the quality-assessment results into metaanalyses. We compared magnitudes of diagnostic odds ratios, widths of their confidence intervals, and changes in a hypothetical clinical decision between strategies. RESULTS: Following 2 definitions of quality, we concluded that only 70 or 72 of 487 studies were of "high quality". This small number was partly due to poor reporting of quality items. None of the strategies for accounting for differences in quality led systematically to accuracy estimates that were less optimistic than ignoring quality in metaanalyses. Limiting the review to high-quality studies considerably reduced the number of studies in all reviews, with wider confidence intervals as a result. In 18 reviews, the quality adjustment would have resulted in a different decision about the usefulness of the test. CONCLUSIONS: Although reporting the results of quality assessment of individual studies is necessary in systematic reviews, reader wariness is warranted regarding claims that differences in methodological quality have been accounted for. Obstacles for adjusting for quality in metaanalyses are poor reporting of design features and patient characteristics and the relatively low number of studies in most diagnostic reviews.

Diagnostic Techniques and Procedures↗

Cell type accuracy of bronchial biopsy specimens in primary lung cancer.

STUDY OBJECTIVES: To evaluate the diagnostic accuracy of bronchial biopsy (BB) specimens in establishing the specific cell type in primary lung cancer (LC), and to study the influence of several factors on this accuracy. SETTING: Tertiary health-care center. PATIENTS: One hundred forty-six patients with LC diagnosed by BB specimens who underwent thoracotomy (T). MEASUREMENTS: We have studied the specific LC cell type observed in the BB specimen and compared it with the T specimen (reference diagnosis). Age, location and type of bronchial lesion, number and size of the biopsy fragments, tumoral size, sample necrosis, degree of cell differentiation, tumoral stage, pathologist's experience, and the presence of other diagnostic tests with the same cell type were analyzed to assess their influence on the concordance between the two diagnoses. RESULTS: The overall concordance between BB and T histologic diagnosis was 0.70 (kappa coefficient [K]). Of the different histologic types, the worst result was obtained in large cell carcinoma (LLC) (K, 0.49). Squamous carcinoma and adenocarcinoma gave similar results (0.74 and 0.77, respectively), while small cell lung cancer (SCLC) only reached a value of 0.60. The degree of cell differentiation, the absence of necrosis, and presence of other preoperative diagnoses were the variables that most influenced the histologic accuracy of BB specimens. Therefore, the probability of BB accuracy was 2.7, 7.7, and 25 times higher in well-differentiated, than in poorly differentiated, moderately differentiated, or undifferentiated carcinomas; 5.2 times higher when there was no necrosis in the sample; and 7.43 higher when there was another preoperative diagnosis. CONCLUSIONS: The histologic results of BB must be examined carefully, especially in cellular subtypes like LLC. The absence of differentiation and presence of necrosis in BB samples were the factors that require the greatest caution in ascertaining the cell type. When they are involved and also in all cases in which identifying the specific cell type has important implications, we prefer to classify the patients as having SCLC or non-small cell lung cancer, and then reclassify them later after using a second diagnostic technique.

Adenocarcinoma↗