Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Intestinal absorption of salicylamide and effect of atropine on it.

The effect of atropine (ATR), a parasynpatholytic agent, on the intestinal absorption of salicylamide (SAM) was studied using the absorption kinetic model proposed by Winne et al. The disappearance of SAM from perfusate and the appearance in intestinal blood were determined using perfused intestinal loop of the rat in vivo. The results showed that the absorption of SAM was simulated by the four compartment model consisting of luminal, interstitial, blood and serosal compartments. The model was assumed to have three rate determining factors, namely mucosal membrane permeability, clearance by blood flow and serosal membrane permeability. ATR decreased the absorption of SAM by decreasing the clearance factor relating to intestinal blood flow and increased the fraction of the transported amount of SAM from interstitial space to serosal compartment.

Animals↗

Investigation of applicability of a mid-infrared spectroscopic method using an attenuated total reflection accessory and a new near-infrared transmission method for determination of faecal fat.

In many laboratories, the titrimetric method of Van de Kamer is used for the analysis of faecal fat content of patients suspected of steatorrhoea. We investigated the applicability of a mid-infrared (MIR) spectroscopic method, using an attenuated total reflection (ATR) accessory, and a new near-infrared (NIR) spectroscopic method. For the NIR method, sealed plastic bags containing the stool samples were used as transmission cells. Standardization was obtained using a previously described MIR method, with a NaCl flow-cell, as reference method. Partial least-squares regression was used for the calibration of each method. Full cross-validation of the calibration set was used for the internal validation of each method. Fifteen per cent of the stool samples could not be estimated with the ATR method within reasonable accuracy limits compared with the reference. The standard error of prediction of the NIR method was 1.1 g/dL. We conclude that the new NIR method is a promising technique for routine use. However, further experiments need to be done with triplicate measurements of each sample and the use of an external validation set.

Calibration↗

Rapid measurement of phytate in raw soymilk by mid-infrared spectroscopy.

The phytate content in soymilk is known to affect tofu curdling. A rapid measurement of phytate from a water extract of soybean (raw soymilk) in an early stage of tofu processing was investigated using mid-infrared spectroscopy (IR) with an ATR accessory. IR absorption of phytate was observed from 1200 cm-1 to 900 cm-1, and saccharide and protein in the extract also had IR absorption in the same region. In order to separate phytate from other components, the phytate was precipitated completely by the addition of calcium under alkaline condition (pH 11.5). The precipitate was dissolved in citrate buffer (pH 6.0) and then used for IR measurement. The absorbance at 1070 cm-1 correlated well with the phytate content of the soymilk. The measurement of phytate in raw soymilk can be done rapidly by FT-IR measurement with an ATR accessory and gives reproducible values, which can be used for the measurement of phytate content in various soybeans for tofu making.

Food Analysis↗

Selective angiotensin receptor antagonism with valsartan decreases arterial stiffness independently of blood pressure lowering in hypertensive patients.

Angiotensin II plays a key role in the development of vascular disease. We examined the long-term effects of selective angiotensin II receptor (ATR) blockade with valsartan on arterial wall stiffness. Brachial to ankle pulse wave velocity (baPWV) was measured in 28 women and 25 men with hypertension (mean age: 62+/-2 years). The measurements were repeated after 24 weeks of treatment with valsartan, 40 to 160 mg/day, with (n=10) or without (n=36) concomitant statin therapy. By multiple regression analysis, baseline baPWV was correlated with age (p<0.001), systolic blood pressure (SBP, p<0.0001), body mass index (p=0.018), and pulse pressure (p=0.005), but not with total cholesterol (p=0.446). Valsartan lowered mean SBP and diastolic blood pressure (DBP) from 155+/-3 to 140+/-3 mmHg and from 90+/-2 to 82+/-2 mmHg, respectively, and mean baPWV from 1,853+/-49 to 1,682+/-52 cm/s. Lowering of baPWV was not influenced by statin therapy. An overlap analysis was performed to separate the effect of angiotensin II receptor blockade from that of blood pressure (BP) lowering. The decrease in the baPWV value of 1,794+/-46 cm/s before valsartan (n=39) vs. 1,663+/-45 cm/s during valsartan (p=0.048, n=31) at a similar mean SBP level (149+/-2 vs. 146+/-3 mmHg, p=0.304) confirmed that ATR blockade had a beneficial effect independent of BP lowering. SBP strongly influences baPWV. However, the decrease in baPWV with valsartan was independent of BP lowering. Statins had no synergistic effect on baPWV. Lowering of baPWV may account for the therapeutic benefit conferred by valsartan independent of its BP-lowering effect.

Angiotensin II Type 1 Receptor Blockers↗

Nonlinear and bistable reflection minima at lambda = 10.6 microm in an attenuated total reflection configuration with a highly doped n-GaAs film.

n-GaAs can be so highly doped that its plasma frequency is larger than the associated frequency of a CO2 laser emission line, leading to a negative real part of the dielectric permittivity. We studied linear and nonlinear reflection properties of structures composed of such thin highly doped n-GaAs film in an attenuated total reflection (ATR) configuration. We show that deep reflection minima coincide with the excitation of Brewster-type modes of the multilayer structure. These minima feature strong nonlinear and bistable behavior and are sensitive to geometrical and material parameters. The proposed ATR configuration can be used to determine doping concentrations with an accuracy of better than 1 partper thousand and different deformation potentials of the higher-conduction bands in n-GaAs.

Journal Article↗

Angular-interrogation attenuated total reflection metrology system for plasmonic sensors.

We develop an angular-interrogation attenuated total reflection (ATR) metrology system for three different plasmonic sensors, namely, a conventional surface plasmon resonance (SPR) device, a coupled-waveguide SPR device, and a nanoparticle-enhanced SPR device. The proposed metrology system is capable of measuring the reflectivity spectra of the transverse magnetic mode and the transverse electric mode simultaneously. Through the optimal control of the fabrication process and use of sophisticated system instrumentation, the experimental results confirm that the developed ATR system is capable of measuring the resonant angle with an angular accuracy of 10(-4) deg.

Journal Article↗

Structural change of water with solutes and temperature up to 100 degrees C in aqueous solutions as revealed by attenuated total reflectance infrared spectroscopy.

The attenuated total reflectance infrared (ATR-IR) spectra of several aqueous solutions have been measured by using a newly developed heatable rod-type ATR cell. The OH stretching bands showed systematic change with increasing solute concentrations and these changes can be explained by four different OH components based on curve-fitting results. NaCl solutions show longer H-bond distance character, while carbonate solutions present shorter ones. The Na2CO3 1 M solution conserves this shorter H-bond nature up to 100 degrees C. On the other hand, the loose nature of NaCl solutions becomes less pronounced at higher temperatures because of the dissociation of pure water clusters. These in situ observations of water structures are generally in agreement with the expected nature of fluids within the earth.

Carbonates↗

Application of mid-infrared spectroscopy: measuring hydrogen peroxide concentrations in bleaching baths.

The presented work applies mid-infrared attenuated total reflection (ATR) spectroscopy to the measurment of hydrogen peroxide in aqueous matrices. The performance of different ATR crystals mounted in flow cells was investigated in the presence of aqueous hydrogen peroxide solutions. Quantitative determination has been achieved by evaluation of specific OH stretching and deformation vibrations with linear correlation between peak areas or peak heights and hydrogen peroxide concentration in the range of 1-10% (weight in water). Important aspects such as chemical stability of the waveguide material and influences of pH and ionic strength on the performance are discussed. Feasibility for the investigation of real world samples is demonstrated by measuring industrial bleaching solutions with known concentrations of hydrogen peroxide fitting well with calibration graphs established with neat hydrogen peroxide solutions. The presented sensor system is capable of determining hydrogen peroxide within complex matrices and clearly corroborates the potential of providing an in situ measurement concept for on-line hydrogen peroxide detection.

Hydrogen Peroxide↗

Limitations of using Raman microscopy for the analysis of high-content-carbon-filled ethylene propylene diene monomer rubber.

The effects of laser irradiation on changes to the surface chemistry and structure of a commercially available ethylene propylene diene monomer (EPDM) rubber sample after Raman microscopy analysis was investigated. The Raman measurements were carried out with different levels of laser power on the sample, ranging from 4.55 mW to 0.09 mW. The surface of the EPDM was analyzed before and after laser exposure using X-ray photoelectron spectroscopy (XPS) and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy. The techniques have surface probe depths of approximately < or = 10 nm and 1 microm, respectively. Both sets of analysis show that ingredients of the blended EPDM rubber "bloom" to the surface as a result of local heating that takes place due to the absorption of laser by carbon black during the Raman analysis. Scanning electron microscopy (SEM) analysis was also performed on the Raman analyzed areas to visually illustrate the effects created due to laser light exposure (i.e., burning marks). The change in surface chemistry also occurs in regions a few millimeters from the exposed sites, indicating that the effect is quite long range. However, this phenomenon has no major influence, as far as XPS or ATR-FTIR results disclose, on the backbone structure of the rubber sample. The results indicate that precautions should be taken when analyzing complex blended polymer samples using Raman spectroscopy.

Journal Article↗

Glucose quantification in dried-down nanoliter samples using mid-infrared attenuated total reflection spectroscopy.

The aim of this study was to determine the feasibility of minimally invasive glucose concentration measurement of a body fluid within the physiologically important range below 100 nL with a number of samples such as interstitial fluid, plasma, or whole blood using mid-infrared spectroscopy, but starting with preliminary measurements on samples of simple aqueous glucose solutions. The Fourier transform infrared spectrometer was equipped with a Golden Gate single reflection diamond attenuated total reflection (ATR) accessory and a room-temperature pyroelectric detector. As the necessary detection limits can be achieved only for dried samples within the spectrometric conditions realized by a commercial instrument, the work focused on the optimization of such ATR measurements. We achieved quantification of samples with volumes as low as 7 nL between 10 and 600 mg/dL. The standard error of prediction (SEP) for the concentration range 10-100 mg/dL is 3.2 mg/dL with full interval data between 1180 and 940 cm(-1). The performance of the prediction is given by a coefficient of variation of prediction (CV(pred) ) of 6.2%. When all samples within the whole concentration range are included, the SEP increases to 20.2 mg/dL, and hence the CV(pred) to 10.6% due to a nonlinear signal dependence on glucose concentration. A detection limit for glucose of 0.7 ng with a signal-to-noise ratio of 10 was obtained.

Glucose↗

Fourier transform infrared attenuated total reflection analysis of human hair: comparison of hair from breast cancer patients with hair from healthy subjects.

A comparative study of Fourier transform infrared attenuated total reflection (FTIR-ATR) spectra of 32 scalp and pubic hair samples from individuals diagnosed with breast cancer and those who were negative for breast cancer showed increases in the beta-sheet/disorder structures (relative to alpha-helix structures) and C-H lipid content of hair from breast cancer patients. Thus, the presence of breast cancer appears to alter the hair growth process, resulting in changes in the composition and conformation of cell membrane and matrix materials of hair fiber. These appear to be consistent with the changes observed in X-ray diffraction patterns for hair from breast cancer patients. A blind study of 12 additional hair samples using these FTIR-ATR spectral differences as markers correctly identified all four hair samples from cancer patients (100%). Two of these samples were from breast cancer patients. Of the remaining two samples analyzing positive for cancer, one was from a prostate cancer patient and one from a lung cancer patient. Thus, it appears that the mechanism that alters hair fiber synthesis in the three types of cancer may be similar. The blind study incorrectly identified as positive for cancer three hair samples from two apparently healthy individuals and one patient considered cured from prostate cancer.

Adolescent↗

Two-dimensional correlation study of uniaxially drawn poly(ethylene terephthalate) films by using attenuated total reflection based dynamic compression modulation step-scan fourier transform infrared in combination with spectral simulation analysis by density functional theory.

Attenuated total reflection (ATR) based dynamic compression modulation two-dimensional (2D) correlation studies of uniaxially drawn poly(ethylene terephthalate) (PET) films have been performed in combination with spectral simulation analysis by density functional theory (DFT). The dynamic 2D infrared (IR) correlation spectra in the region of the CCO stretching mode vibrations show four distinct correlation peaks located around 1290, 1265, 1248, and 1234 cm(-1). These bands can be clearly assigned to the combination bands or coupling modes of the CH in-plane bend of the benzene ring or the CH(2) deformation of the ethylene glycol unit, as well as CCO stretching vibrations, which are gauche conformer's characteristic bands, by DFT analysis. The sequential analysis of 2D correlation data shows that, upon applying the dynamic compression, the response of the side chain regions (ester groups) occurs first, followed by that of the backbone regions (benzene rings). The ATR based dynamic compression modulation 2D correlation spectroscopy in combination with DFT analysis can be a powerful tool for various polymer characterizations.

Algorithms↗

Differentiation of selected Salmonella enterica serovars by Fourier transform mid-infrared spectroscopy.

Salmonella enterica serovars include pathogens responsible for high numbers of foodborne salmonellosis. Fourier transform infrared (FT-IR) spectroscopy can be used to rapidly and accurately identify microorganisms based on unique spectra of bacterial cell components. The objectives of this study were to discriminate closely related Salmonella enterica serovars by using FT-IR spectroscopy and multivariate analysis and to compare the performance of three techniques for differentiating among Salmonella serovars. Selected serovars of S. enterica were streaked onto plate count agar and incubated (37 degrees C, 24 h). Isolated colonies were suspended in phosphate buffer or 50% ethanol (10 microL). Suspensions were placed on (1) ZnSe crystals for transmission, (2) disposable polyethylene membranes (DPM) for transmission, and (3) diamond crystal plate for attenuated total reflectance (ATR) analyses; all samples were dried under vacuum. Classification models, soft independent modeling of class analogy (SIMCA), from derivatized infrared spectra (1300-900 cm(-1)), discriminated among Salmonella serovars presumably attributed to cell's lipopolysaccharides (1000-980 cm(-1)). Samples on DPM required high cell density for reliable spectra. High-quality spectra were obtained when a single colony was suspended in ethanol or buffer and mounted on ZnSe crystals for transmission or diamond plate for ATR analysis. Prediction of unknowns, representative of serovars used to construct classification models, showed that all techniques were suitable for the rapid and accurate differentiation of Salmonella serovars.

Algorithms↗

Quantitative analyses of absorption-sensitive surface plasmon resonance near-infrared spectra.

Surface plasmon resonance near-infrared (SPR-NIR) spectroscopy provides 10-100 times absorption enhancement compared with the absorption in the corresponding attenuated total reflection (ATR) NIR spectra. However, analysis of the enhanced SPR-NIR spectra is not straightforward because of the substantial contribution from SPR. This paper proposes two analysis methods for concentration-dependent changes of SPR-NIR spectra from a viewpoint of change in absorption intensity. One is based on rapid scans of the SPR-NIR spectra with a fixed incident angle, and the other is based on multi-angle sequential scans. A concentration of methanol in water has successfully been determined by both methods. From the measurement of the light intensity within an absorption band of water (5230-5120 cm(-1)) at a fixed incident angle, the concentration was calibrated to an accuracy of 0.02 wt. %. In the latter multi-angle method, it has been proved that computed bottom ridges of the envelope curve of the SPR-NIR spectra are not only enhanced 30 times compared with the corresponding ATR-NIR spectra, but are also equivalent to the conventional transmittance NIR spectra in quality. The bottom ridges allow us to analyze SPR-NIR spectra in the same manner as conventional spectral analyses based on Beer's law.

Journal Article↗

The brass light pipe: an easy way to obtain infrared spectra of liquid films and monolayers.

We describe a brass light pipe (LP) mounted in a cylindrical optical accessory for attenuated total reflection (ATR) that can be used to readily obtain the infrared spectra of liquids and monolayers. As examples, we show the LP spectra of isooctane, decane, dimethyl malonate, dodecanol, dodecanethiol, and acetic acid and compare them to those obtained by transmission as well as by ATR. In addition, we utilize a dodecanethiol monolayer spectrum to illustrate the sensitivity of the LP scheme.

Journal Article↗

Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector.

The number of techniques and instruments available for Fourier transform infrared (FT-IR) microspectroscopic imaging has grown significantly over the past few years. Attenuated total internal reflectance (ATR) FT-IR microspectroscopy reduces sample preparation time and has simplified the analysis of many difficult samples. FT-IR imaging has become a powerful analytical tool using either a focal plane array or a linear array detector, especially when coupled with a chemometric analysis package. The field of view of the ATR-IR microspectroscopic imaging area can be greatly increased from 300 x 300 microm to 2500 x 2500 microm using a larger internal reflection element of 12.5 mm radius instead of the typical 1.5 mm radius. This gives an area increase of 70x before aberrant effects become too great. Parameters evaluated include the change in penetration depth as a function of beam displacement, measurements of the active area, magnification factor, and change in spatial resolution over the imaging area. Drawbacks such as large file size will also be discussed. This technique has been successfully applied to the FT-IR imaging of polydimethylsiloxane foam cross-sections, latent human fingerprints, and a model inorganic mixture, which demonstrates the usefulness of the method for pharmaceuticals.

Dermatoglyphics↗

HIV-1 Vpr-induced apoptosis is cell cycle dependent and requires Bax but not ANT.

The HIV-1 accessory protein viral protein R (Vpr) causes G2 arrest and apoptosis in infected cells. We previously identified the DNA damage-signaling protein ATR as the cellular factor that mediates Vpr-induced G2 arrest and apoptosis. Here, we examine the mechanism of induction of apoptosis by Vpr and how it relates to induction of G2 arrest. We find that entry into G2 is a requirement for Vpr to induce apoptosis. We investigated the role of the mitochondrial permeability transition pore by knockdown of its essential component, the adenine nucleotide translocator. We found that Vpr-induced apoptosis was unaffected by knockdown of ANT. Instead, apoptosis is triggered through a different mitochondrial pore protein, Bax. In support of the idea that checkpoint activation and apoptosis induction are functionally linked, we show that Bax activation by Vpr was ablated when ATR or GADD45alpha was knocked down. Certain mutants of Vpr, such as R77Q and I74A, identified in long-term nonprogressors, have been proposed to inefficiently induce apoptosis while activating the G2 checkpoint in a normal manner. We tested the in vitro phenotypes of these mutants and found that their abilities to induce apoptosis and G2 arrest are indistinguishable from those of HIV-1NL4-3 vpr, providing additional support to the idea that G2 arrest and apoptosis induction are mechanistically linked.

Adenine Nucleotide Translocator 1↗

Fourier transform infrared quantitative analysis of sugars and lignin in pretreated softwood solid residues.

Hydrolysates were obtained from dilute sulfuric acid pretreatment of whole-tree softwood forest thinnings and softwood sawdust. Mid-infrared (IR) spectra were obtained on sample sets of wet washed hydrolysates, and 45 degrees C vacuum-dried washed hydrolysates, using a Fourier transform infrared (FTIR) spectrophotometer equipped with a diamond-composite attenuated total reflectance (ATR) cell. Partial least squares (PLS) analysis of spectra from each sample set was performed. Regression analyses for sugar components and lignin were generated using results obtained from standard wet chemical and high-performance liquid chromatography methods. The correlation coefficients of the predicted and measured values were >0.9. The root mean square standard error of the estimate for each component in the residues was generally within 2 wt% of the measured value except where reported in the tables. The PLS regression analysis of the wet washed solids was similar to the PLS regression analysis on the 45 degrees C vacuum-dried sample set. The FTIR-ATR technique allows mid-IR spectra to be obtained in a few minutes from wet washed or dried washed pretreated biomass solids. The prediction of the solids composition of an unknown washed pretreated solid is very rapid once the PLS method has been calibrated with known standard solid residues.

Biomass↗