Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

T-pins in a direct pattern technique for posts and cores.

A practical direct technique for making post and core impressions with a T-pin and self-curing acrylic resin was described. Emphasis was placed on the function of the T-shaped plastic pin in fabricating the pattern. Clinical procedures for each step were described in detail. The unique characteristic of the T-pin of softening and becoming very sticky when exposed to direct contact with acrylic resin monomer allows soft acrylic resin to adhere to it, resulting in an accurate direct impression of the canal.

Acrylic Resins↗

Treatment prostheses in TMJ dysfunction-pain syndrome.

Various types of acrylic resin therapeutic prostheses commonly used in the treatment of TMJ dysfunction-pain syndrome were described. Each design was related to recent data concerning optimum condylar positions in the fossae, the physiologic condylar suspension system, and individual treatment objectives for repositioning the mandibular condyles. For example, alteration of the vertical dimension of occlusion is a popular treatment procedure that is empirical in nature and is usually used without TMJ radiographs or a differential diagnosis. It can violate the physiologic requirements of the interocclusal distance or the speaking space and does not necessarily move the condyles forward as has been commonly thought. The dangers of empirical treatment procedures for a multicausal dysfunction syndrome have been pointed out. An example was cited where the mandible was moved forward for a long period of time with a repositioning prosthesis; this produced pathologic TMJ remodeling and continued pain. It was recommended that specific mandibular repositioning be based on the type of condylar displacement observed on the radiographs. Sometimes the condyles should be retruded, and other times they should be repositioned anteriorly or occasionally inferiorly on one side. Long-standing use of any acrylic resin repositioning prosthesis is contraindicated, particularly without close supervision. Acrylic resin anterior bite plates (with a minimum opening of 1 mm) were recommended for the relief of acute trismus or intractable pain. Usually the prosthesis is used in conjunction with heat and drug therapy. This type of prothesis can also be utilized to deprogram the muscles when a strong habit of eccentric occlusion develops as a result of missing teeth. (This should be confirmed by TMJ radiographs.) Occasionally atypical pain is present and a differential diagnosis can be established between TMJ dysfunction or neurologic etiology by the physiologic response to bite plate therapy. When it is necessary to reposition the mandibular condyles anteriorly the occlusion is adjusted to provide the planned anterior movement without increasing the vertical dimension of occlusion. A temporary acrylic resin prosthesis is used to retrain the muscle programming to the anterior therapeutic mandibular position. When the symptoms are relieved and the corrective condylar position is confirmed with TMJ radiographs, a more permanent repositioning prosthesis is made. The treatment of TMJ dysfunction-pain syndrome should be based on documented data including the pain history, TMJ radiographs, condylar position in the fossae, electromyographic evidence, and occlusal analysis. This information will help determine if the patient's centric relation is functional or dysfunctional and will indicate the recommended treatment procedures.

Acrylic Resins↗

Trial base adapted with sealed temporary soft liner.

Autopolymerizing acrylic resin is combined with temporary soft reline material to make a record base. Rigid acrylic resin is formed over a wax spacer. The wax is removed and the loose-fitting base is relined on the master cast with soft reline material. The soft material is cured in a pressure pot and sealed with a mono-poly mixture. Visible light-curing material can be used instead of autopolymerizing acrylic resin.

Acrylic Resins↗

Mechanical properties of a light-polymerizing provisional restorative material with and without reinforcement fibers.

Interim restorations are vulnerable to inadvertent fracture during mastication. Autopolymerizing acrylic resins have traditionally been selected for fabrication of provisional restorations. Triad light-polymerizing tooth-colored acrylic resin was recently introduced as an alternative material for this procedure. This material does not contain methyl methacrylate monomer and permits an increased working time. Heavy occlusal forces may initiate cracks within these restorations, and propagation of these cracks may ultimately lead to failure. Various forms of reinforcement fibers are available and are marketed for strengthening dental resins used for provisional restorations. Investigators have demonstrated that the mechanical properties of acrylic resins may be improved with the incorporation of reinforcing fibers, but a published evaluation of fiber-reinforced light-polymerizing provisional restorative materials is lacking. This investigation recorded and compared two mechanical properties of one light-polymerizing provisional restorative material with and without incorporation of vertically and horizontally oriented woven, matted, polyethylene fibers. No significant difference in modulus of rupture was recorded between groups with and without fibers. The mean flexural elastic modulus of the group with the horizontally oriented fibers was significantly greater than the mean flexural elastic modulus of the specimens without incorporated fibers.

Acrylic Resins↗

The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns.

STATEMENT OF PROBLEM: In immediate implant loading, it is important to keep provisional restorations in place during early-phase healing. Current luting agents for provisional restorations may provide inadequate retention, creating a clinical challenge. PURPOSE: This study compared the retention of provisional autopolymerizing acrylic resin implant-supported single restorations with combinations of different implant abutment surface conditions and provisional luting agents. MATERIAL AND METHODS: Thirty solid titanium implant abutments (ITI), 4 mm high, were divided into 3 groups. Ten abutments were unaltered, 10 were airborne-particle abraded with 50-microm aluminum oxide, and 10 were roughened with a medium-roughness diamond rotary cutting instrument. Thirty implant analogs (ITI) were mounted in autopolymerizing acrylic resin blocks. A solid titanium implant abutment was placed in each implant analog and torqued to 35 N.cm. After fabrication of 4 provisional acrylic resin crowns for each abutment, provisional luting agents TempBond, TempBond NE, Life, and Zone were used to secure the provisional crowns to the respective abutments. All specimens were luted with one of the provisional luting agents for a given test. After ultrasonic cleaning of the abutments, another provisional crown was luted with another luting agent. All specimens were stored in 100% humidity environment for 1 day at 37 degrees C prior to testing. Each provisional acrylic resin crown was pulled from the abutment with a 500-kg load cell in a universal testing machine at a crosshead speed of 0.5 cm/minute, and tensile strength was recorded (N). Data were analyzed using analysis of variance (ANOVA) and the Scheffe test (alpha=.05). RESULTS: Tensile strength was significantly higher for Life and TempBond NE than for TempBond and Zone, regardless of the surface conditions (P=.0001). The result of the 2-way ANOVA indicated that a significant interaction existed between the provisional luting agents and surface conditions (P=.0039). TempBond NE showed significantly higher tensile strength when combined with airborne-particle-abraded surfaces compared to other combinations (P=.011). However, no difference was found in tensile strength of Life and Zone between different combinations. The tensile strength of TempBond was lower when used with the unaltered surface compared to other combinations (P=.001). CONCLUSION: Surface modification of an implant abutment by airborne-particle abrasion or diamond rotary cutting instrument did not improve retention of a provisional acrylic crown when Life or Zone was used as the luting agent. Airborne-particle abrasion may be an effective method to increase retention of a provisional acrylic crown when TempBond NE is used.

Acrylic Resins↗

An investigation of debonding between heat-cured PMMA and titanium alloy (Ti-6A1-4V).

OBJECTIVES: The bonding of acrylic resin to dental prostheses constructed from metal has been the subject of extensive research in recent years, much of it between base-metal alloys such as Ni-Cr alloys and dental composite. The development of techniques for the manufacture of dental appliances from titanium and titanium alloys has opened new avenues for investigation of the metal/acrylic resin bond. METHODS: In this study, a bond strength comparison between two PMMA products, Trevalon and Metadent, and discs of titanium alloy, Ti-6A1-4V, was investigated using a four-point bend test configuration. Trevalon is a standard, commercially available, heat-cured acrylic resin, while Metadent is an acrylic resin incorporating a chemical bonding agent, 4-META. A comparison was made between two processes that are routinely used to enhance the bond between metal and acrylic, namely sandblasting of the metal surface and using the Silicoater system following sandblasting. Each of the samples was paired, thus allowing a further comparison to be made between samples that had undergone thermocycling in a water bath, with those that had been held at a constant temperature. RESULTS: The study revealed that a superior metal/acrylic bond was achieved by the use of the silicoating system when either Trevalon or Metadent was used both before and after thermocycling. Reduced debonding loads were recorded for all samples that had undergone thermocycling. CONCLUSIONS: Highest bond strengths were recorded for Trevalon or Metadent processed against a silicoated Ti-alloy surface.

Acrylic Resins↗

Dimensional accuracy of duplicate dentures prepared by different methods.

The production of a duplicate denture demands a high degree of perfection to maintain dimensional accuracy of the duplicate denture. Duplicate dentures were made by four methods in order to investigate the dimensional accuracy in relation to a master denture. Replicas made from modeling wax (all-wax replica or acrylic resin base-wax teeth replica) demonstrated better dimensional accuracy compared with the all-acrylic resin replicas. It is well known that modeling wax used alone as a temporary denture base is an unsatisfactory material. The inherent shortcomings of the material may be overcome if dentists and patients make their assessment of the duplicate as quickly as possible in the mouth. The other alternative may be the production of a duplicate denture with an acrylic resin base and modeling wax teeth.

Acrylic Resins↗

Dimensional and occlusal changes in fluid resin dentures.

This study evaluated complete dentures processed with fluid acrylic resins. The dentures were constructed with the aid of a new flask and modified spruing procedures, with the teeth immobilized in the hydrocolloid mold, and with slight mechanical vibration provided during the pouring of the resin. The fluid resin dentures were compared with the dentures constructed by the compression-molding technique and processed with heat-curing acrylic resin. The results indicate that the fluid resin dentures underwent more processing shrinkage (0.617%) than the conventionally processed dentures (0.377%). However, the fluid resin dentures seemed to function as well as the heat-cured dentures. The excessive reduction in the vertical dimension of the occlusion usually observed with fluid resin dentures was minimized; the average cusp height reduction was -0.089 mm. Individual tooth movement, voids, visible porosity, and other surface deficiencies were eliminated.

Acrylic Resins↗

Perceived side effects of biomaterials in prosthetic dentistry.

The present questionnaire survey of side effects of biomaterials in prosthodontics had a response rate of 64%. There were occupational health problems associated with a variety of dental materials, especially acrylic resins, eugenol-containing materials, and elastomer impression materials. Most reactions were mild to moderate dematoses of the fingers or hands, but one prosthodontist had to cease practice due to a severe allergic reaction to acrylic resin materials. Of the respondents, 8% had experienced reactions to latex gloves. Nondermatologic reactions seemed to be transient, affecting the eyes, respiratory pathways, or occasionally causing generalized symptoms. These reactions were mainly attributed to vapors from acrylic resin monomers or cyanoacrylates. Adverse reactions in patients, tentatively estimated to be one out of 300, were observed by 40% of the prosthodontists, mostly as intraoral reactions. Acrylic resins, eugenol-containing cements, base metal alloys, mercury, gold, polyether/epimine based materials, and tissue conditioners were cited as causes. Skin contact with the dentists' latex gloves elicited extraoral reactions in some patients.

Biocompatible Materials↗

An evaluation of impression techniques for multiple internal connection implant prostheses.

STATEMENT OF PROBLEM: Movement of impression copings inside the impression material using an open-tray impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the definitive cast. Consequently the restoration may require corrective procedures. PURPOSE: This in vitro study evaluated the accuracy of 3 different impression techniques using polyether impression material to obtain a precise definitive cast for a multi-unit implant restoration with multiple internal connection implants. MATERIAL AND METHODS: A reference acrylic resin model with 4 internal connection implants (3i Implant Innovations) was fabricated. Forty-five medium-consistency polyether impressions (Impregum Penta) of this model were made with square impression copings using an open-tray technique. Three groups of 15 specimens each were made with different impression techniques: in the first group, nonmodified square impression copings were used (NM group); in the second group, square impression copings were used and joined together with autopolymerizing acrylic resin before the impression procedure (R [resin] group); and in the third group, square impression copings previously airborne-particle abraded and coated with the manufacturer-recommended impression adhesive were used (M [modified] group). Matching implant replicas were screwed into the square impression copings in the impressions. Impressions were poured with ADA type IV stone (New Fujirock). A single calibrated examiner blinded to the nature of the impression technique used examined all definitive casts to evaluate the positional accuracy (mum) of the implant replica heads using a profile projector (at original magnification x10). These measurements were compared to the measurements calculated on the reference resin model which served as control. Data were analyzed with a 1-way analysis of variance at alpha=.05, followed by the Student Newman-Keuls test (alpha=.05). RESULTS: The data obtained with the profile projector revealed significant differences within the 3 impression techniques ( P <.001). The Student Newman-Keuls procedure disclosed significant differences between the groups, with group R casts being significantly more accurate than group NM and group M casts ( P =.05). The mean distance (+/-SD) between the posterior implants compared to the reference acrylic resin model was 18.17 mum (+/- 6.4) greater for group R casts, 41.27 mum (+/- 8.4) greater for group M casts, and 46.21 mum (+/- 8.9) greater for group NM casts. Distances between the anterior implants were also greater than those recorded on the reference model. The distance was 15.23 mum (+/- 5.9) greater on group R casts, 38.17 mum (+/- 8.3) greater on group M casts, and 43.23 mum (+/- 8.7) greater on group NM casts. CONCLUSION: Within the limitations of this study, improved accuracy of the definitive cast was achieved when the square impression copings joined together with autopolymerizing acrylic resin were used to make an impression of multiple internal connection implants.

Acrylic Resins↗

Laboratory procedures for the maintenance of a removable partial overdenture.

Laboratory procedures in support of maintenance therapy for a typical patient with a removable partial overdenture were described. These procedures consisted of the fabrication of a gold metal coping and the reline of the prosthesis with autopolymerizing acrylic resin. In designing the coping contours, the technician must consider the path of insertion of the prosthesis and the space requirement for the overlying resin tooth. Reproduction of the dowel preparation is facilitated by using a plastic dowel as part of the coping wax pattern. The removable partial overdenture was relined with autopolymerizing acrylic resin in a reline jig. Tooth-colored acrylic resin was used in the concavity formed by the overdenture abutment to enhance esthetics. The requirement of a coordinated effort between the dentist and the dental laboratory technician is critical to the successful treatment of the removable partial overdenture patient.

Acrylic Resins↗

[Reinforcement for overdentures on abutment teeth].

PURPOSE: This study investigated the effect of the position of reinforcement wires, differences in artificial teeth, and framework designs on the breaking strength of overdentures. METHODS: The basal surfaces of composite resin teeth and acrylic resin teeth were removed using a carbide bur. A reinforcement wire or a wrought palatal bar was embedded near the occlusal surface or basal surface. Four types of framework structures were designed : conventional skeleton (skeleton), housing with skeleton (housing), housing plus short metal backing (metal backing), and housing plus long metal backing (double structure). After the wires, bars, and frameworks were sand-blasted with 50 microm Al(2)O(3) powder, they were primed with a metal primer and embedded in a heat-polymerized denture base resin. The breaking strengths (N) and maximum stiffness (N/mm) of two-week aged (37 degrees C) specimens were measured using a bending test (n=8). All data obtained at a crosshead speed of 2.0 mm/min were analyzed by ANOVA/Tukey's test (alpha=0.01). RESULTS: There were no statistical differences between the two kinds of artificial teeth (p>0.01). The wrought palatal bar had significantly higher strength than the reinforcement wire (p<0.01). Greater strengths were found for specimens with frameworks than those without frameworks (p<0.01). The breaking strength of the wrought palatal bar embedded near the occlusal surface was higher than that on the basal surface (p>0.01). The breaking strength and maximum stiffness of the double structure framework were significantly greater (p<0.01) than those of the conventional frameworks. CONCLUSION: The breaking strengths of overdentures were influenced by the size and position of the reinforcement wires. Double structure frameworks are recommended for overdentures to promote a long-term prognosis without denture breakage.

Acrylic Resins↗

Esthetic potential of single-implant provisional restorations: selection criteria of available alternatives.

UNLABELLED: Provisional implant restorations are essential tools used to optimize the esthetic outcomes for single-tooth implant restorations. This article describes three groups of available alternatives and the specific options within each group including removable prostheses (interim removable partial denture, vacuum-formed appliance), tooth-supported prostheses (bonded extracted or denture teeth, cast metal or fiber-reinforced resin-bonded fixed partial denture [FPD], wire-retained resin-bonded FPD, acrylic resin provisional FPD), and implant-supported fixed prostheses (implant-retained provisional restoration). Advantages and disadvantages as well as fabrication guidelines for each option are provided. The author proposes that the restorative dentist consider eight criteria in selecting the most appropriate type of provisional prosthesis for a specific patient situation including the esthetic potential, patient comfort, treatment time, laboratory cost, occlusal clearance, ease of removal, durability, and ease of modification. The patient's esthetic expectations are critical in determining the most suitable type of provisional restoration. Esthetically pleasing provisional restorations are part of the evolving implant continuum, making implant dentistry more appealing to practicing dentists and potential patients. CLINICAL SIGNIFICANCE: Provisional restorations for single implants have evolved from temporary expedients during osseous and soft tissue integration to critical therapeutic tools used to assess patient expectations, communicate with the laboratory, and optimize definitive implant treatment. The selection of the type of provisional restoration may significantly influence esthetics during the period of implant integration and soft tissue healing. However, it is unlikely that there is a direct correlation between the type of provisional restoration used and the esthetic outcome of the definitive prosthesis.

Acrylic Resins↗

[Quantitative changes of microflora on stress-bearing areas relating to bases of removable partial dentures].

OBJECTIVE: This study was designed to find out the changes in microflora on the stress-bearing areas after insertion of removable partial dentures, and in turn to explore the difference between such changes caused by metal bases and acrylic resin bases respectively. METHODS: Sixteen patients who were ready to accept removable partial dentures were selected and divided into two groups. Eight patients used metal bases while the other eight patients used acrylic resin bases. Then at the following three points: before dentures were inserted, one month after wearing and three months after wearing, the total cultivable flora were counted and the proportions of bacteria detected on the stress-bearing areas were calculated. RESULTS: No matter what type of bases was selected, the wearing of removable partial denture enhanced the accumulation of microflora on stress-bearing areas. The percentages of Candida albicans and Lactobacilli detected on stress-bearing areas also increased significantly (P < 0.05). When such changes were compared, the authors found that the increment of Candida albicans caused by acrylic resin bases was higher than that caused by metal bases (P < 0.05). CONCLUSION: The wearing of removable partial dentures forms new retention areas between the bases and the stress-bearing areas, as a result enhances the deposit of microbe and facilitate the growth of Candida albicans and Lactobacilli. Compared with increment of Candida albicans caused by metal bases, the increment relating to acrylic resin bases is more evident.

Aged↗

Cement-retained superstructure for a metal-resin fixed complete denture.

This article describes a method of fabricating a metal-resin fixed complete denture using a cemented acrylic resin superstructure over a metal bar that is screw-retained. The primary advantage of this design over traditional designs is that there are no screw access openings in the acrylic resin or denture teeth. Advantages include improved esthetics, ease of fabrication and tooth arrangement, simplification of procedures, and the opportunity to easily replace worn teeth when necessary.

Acrylic Resins↗

Accuracy of implant impression techniques.

Three impression techniques were assessed for accuracy in a laboratory cast that simulated clinical practice. The first technique used autopolymerizing acrylic resin to splint the transfer copings. The second involved splinting of the transfer copings directly to an acrylic resin custom tray. In the third, only impression material was used to orient the transfer copings. The accuracy of stone casts with implant analogs was measured against a master framework. The fit of the framework on the casts was tested using strain gauges. The technique using acrylic resin to splint transfer copings in the impression material was significantly more accurate than the two other techniques. Stresses observed in the framework are described and discussed with suggestions to improve clinical and laboratory techniques.

Acrylic Resins↗

The use of lipiodol in spiral tomography for dental implant imaging.

Preoperative radiographic assessment is mandatory for the meticulous treatment planning and successful placement of implants. The precise topographical evaluation of selected implant sites, apart from the most straightforward cases, requires tomographic examination with the use of diagnostic radiographic templates. The incorporation of various radiopaque materials such as barium sulphate and lead foil as radiographic markers had not been entirely satisfactory. A new contrast medium, Lipiodol ethiodized oil (Laboratoire Guerbet, Paris, France), can easily be mixed with the monomer of autopolymerizing acrylic resin. The resultant acrylic template has several advantages. The tomographic images (Scanora; Soredex Orion Corporation, Helsinki, Finland) are radiographically homogenous and show the contour of the future prosthesis, the angulation of the planned implant, and the thickness of the soft tissue. In addition, the radiopaque template is optically transparent (with a slight yellow tint), which facilitates good visibility of surgical sites when the template is modified to become the surgical guide for implant placement. This transparent template can be further modified for implant position registration at the time of surgery. Because this multipurpose template is simple to construct and inexpensive, it can be recommended for routine use in implant dentistry.

Acrylic Resins↗