Coupling HPLC to GC: why? How? With what instrumentation?

Coupling LC to GC alleviates sample preparation in the sense of preseparation, cleanup, or enrichment and replaces conventional methods such as column liquid chromatography, enrichment by or filtration through sample preparation tubes, preparative thin-layer chromatography, or liquid-liquid partitioning. LC is more efficient in separation power, more rapid, and allows fully automatic integration of sample preparation into GC. Advantages are discussed for selected applications. The transfer techniques, as well as some key requirements for an LC-GC instrument, are briefly summarized.

Chromatography, Gas↗

Ultra-high flow rate capillary liquid chromatography with mass spectrometric detection for the direct analysis of pharmaceuticals in plasma at sub-nanogram per millilitre concentrations.

Ultra-high flow rate liquid chromatography on large particle size stationary phases coupled with mass spectrometric detection (particularly tandem mass spectrometry, MS/MS) is gaining increasing usage for the direct determination of pharmaceuticals in biological fluids. The lack of sample preparation required prior to chromatographic and MS/MS analysis, together with the extremely high throughput of the chromatography, make the technique extremely attractive to the modern pharmaceutical bioanalyst. However, this lack of sample preparation also means that there is no potential for concentration of the sample and, as a consequence, the sensitivity of the technique has been limited. Liquid chromatography on the capillary scale offers sensitivity benefits compared with conventional liquid chromatography as the volume in which the analyte peaks are eluted is greatly reduced. In this paper, we present the use of ultra-high flow rate liquid chromatography on the capillary scale. This enables the quantification of drugs in plasma at sub-nanogram per millilitre concentrations from a very small (2.5 micromgL) aliquot of plasma without sample preparation. We also compare the resolution obtained by ultra-high flow rate liquid chromatography with that achieved on short columns packed with conventional size packing materials operated in an isocratic manner.

Animals↗

Determination of biologically active low-molecular-mass thiols in human blood. III. Highly sensitive narrow-bore isocratic reversed-phase high-performance liquid chromatography with fluorescence detection.

The fast isocratic narrow-bore reversed-phase high-performance liquid chromatographic method employing fluorescence detection is described for the precise reproducible simultaneous measurement of total homocysteine, cysteine and glutathione in human blood. Sample preparation involves conversion of disulfides to free thiols with triphenylphosphine, precipitation of proteins with sulfosalicylic acid, and conjugation of thiols with monobromobimane. Optimized sample preparation conditions as well as chromatographic conditions allowed to obtain reliable quantitative results within the concentration range corresponding to the levels of these thiols in human blood in norm and pathology. The detection limit was approximately 70 amol for all labeled aminothiols. The proposed method for these compounds analysis includes simple sample preparation, high selectivity, good linearity (r2>0.998), high reproducibility (within-run precision for derivatized aminothiol peaks area RSD<1.8% for three times consequently injected sample); high reliability and the small sample volume (1 microl) required for analysis make it suitable for clinical studies.

Chromatography, High Pressure Liquid↗

Modification of reagents in the EnviroAmp kit to increase recovery of Legionella organisms in water.

Organisms of the bacterial genus Legionella, commonly found in aqueous reservoirs, have been associated with Legionnaires' disease (legionella pneumonia, caused by Legionella pneumophila) and Pontiac fever (nonpneumonic legionellosis). EnviroAmp Legionella sample preparation, polymerase chain reaction amplification, and detection kits (Perkin-Elmer Corp.) were developed for rapid detection of DNA from organisms of the genus Legionella and the species L. pneumophila from environmental water samples. The kits are based on molecular techniques incorporating polymerase chain reaction amplification and detection by reverse dot blot hybridization to particular genus and species probes. The manufacturer states that the EnviroAmp Legionella sample preparation, polymerase chain reaction amplification, and detection kits can detect approximately 100 Legionella organisms/mL (10,000 organisms/100 mL) in the original water sample. The sensitivity of the kits was increased to 0.1 colony-forming units/mL (10 colony-forming units/100 mL), at least for cultured organisms, by modifying the EnviroAmp Legionella sample preparation kit protocol. Data obtained in this study indicated that sample volume could be increased from 100 to 1000 mL (in the absence of interfering substances such as humic acid) and DNA extraction volume could be decreased from 2 to 0.5 mL to increase the ability of the kit to detect lower numbers of Legionella spp. or L. pneumophila per volume.

DNA, Bacterial↗

Stable isotope dilution high-performance liquid chromatography-electrospray ionization mass spectrometry method for endogenous 2- and 4-hydroxyestrones in human urine.

A sensitive, precise and accurate stable isotope dilution high-performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for measuring endogenous 2- and 4-hydroxyestrones, the main catechol estrogens in human urine. Compared to the published methods using gas chromatography-mass spectrometry, this approach simplifies sample preparation and increases the throughput of analysis. The unique part of our method is the use of a simple and rapid derivatization step that forms a hydrazone at the C-17 carbonyl group of catechol estrogens. This derivatization step has greatly enhanced method sensitivity as well as HPLC separability of 2- and 4-hydroxyestrones. Standard curves were linear over a 100-fold calibration range with correlation coefficients for the linear regression curves typically greater than 0.996. The lower limit of quantitation for each catechol estrogen is 1 ng per 10-ml urine sample, with an accuracy of 97-99% and overall precision, including the hydrolysis, extraction and derivatization steps, of 1-3% for samples prepared concurrently and 2-11% for samples prepared in several batches. This method is adequate for measuring the low endogenous levels of catechol estrogens in urine from postmenopausal women.

Adult↗

On-line coupling of miniaturized solid-phase extraction and microcolumn liquid-phase separations.

On-line coupling of miniaturized solid-phase extraction methods and microcolumn separation techniques are reviewed. A conventional solid-phase micro-extraction device and fiber-in-tube solid-phase extraction was employed as the sample preparation method. In the fiber-in-tube technique, a novel fibrous polymeric material was introduced as the extraction medium for the microscale sample preparation step which could be directly coupled with microcolumn liquid-phase separation systems, such as microcolumn liquid chromatography, capillary electrophoresis, and capillary electrochromatography. The applications of these hyphenated systems, consisting of the sample preparation and separation processes, are also reviewed.

Capillary Action↗

Determination of urapidil and its metabolites in human serum and urine: comparison of liquid-liquid and fully automated liquid-solid extraction.

Direct injection of biological fluids into an automated pre-column system for high-performance liquid chromatographic quantitation of urapidil and its metabolites was compared with sample preparation by liquid-liquid extraction. On-line sample purification and enrichment proved to be a superior method for quantitation of the parent compound and its metabolites in serum, plasma, and urine. The automatic procedure circumvents the disadvantages of conventional sample work-up by extraction, such as time-consuming and complicated sample preparation, the need for large samples, poor recovery, and formation of artefacts. Injection of 100 microliters of serum into the automated pre-column system, followed by high-performance liquid chromatography with electrochemical detection, gave a detection limit for urapidil and metabolites in serum of 5 ng/ml. For urine samples with injection of 50 microliters the detection limit for the same compounds was 100 ng/ml using UV detection, which is adequate for evaluating renal excretion. Accuracy as well as precision of the analyses were better than 10% for concentrations above 100 ng/ml. In contrast to the direct injection method, liquid-liquid extraction requires 1-2 ml of serum, plasma, or urine for clean-up. Moreover, the extraction yield for the main human metabolite is significantly lower, and its stability after extraction is inadequate for using an autosampler. The direct injection method was applied in studying the pharmacokinetics and metabolism of urapidil in healthy volunteers and patients. So far, ca. 15 000 urapidil samples (both serum or plasma and urine) have been analysed by this technique.

Antihypertensive Agents↗

Influence of drying procedure on the mesoporosity and surface fractal dimensions of silica xerogels prepared with different agitation methods.

Silica xerogels were prepared by thermal drying wet gels in an electric oven (70 degrees C) after certain duration of ambient drying, and the relevant effect is investigated on the mesopore structures and surface fractal dimensions of the resultant xerogels. The silica gels were derived from a hydrochloric acid-catalyzed TEOS (tetraethylorthaosilicate) system, and both magnetic stirring and ultrasonic vibration were adopted during sol preparation. The percentage mesoporosity and surface fractal dimensions are evaluated using image analysis methods, based on FE-SEM (field emission gun-scanning electron microscopy) images. The results show that the mesoporosity of the resultant xerogels decreases with the duration of ambient drying for samples prepared using magnetic stirring and low-intensity ultrasonic vibration, while samples subjected to high-intensity ultrasound show a somewhat reverse trend. Samples prepared with magnetic stirring have almost constant surface fractal dimensions (nearly 3), irrespective of the ambient drying before thermal drying. The surface fractal dimensions of samples prepared using ultrasound increase with the duration of ambient drying.

Journal Article↗

Application of column-switching liquid chromatography-tandem mass spectrometry for the determination of pharmaceutical compounds in tissue samples.

Information on plasma-tissue distribution which is important for drug development may be obtained by "in silico" prediction tools. To support the validation of computer models, drug concentrations in rat plasma and tissues (brain, liver, kidney, testes, spleen, gut, lung. heart, muscle, skin and fat) had to be determined. In our work, we established analytical assays for a variety of substances including nicardipine, nitrendipine, felodipine and benzodiazepines. Sample preparation had to be simple and method development as well as analytical run time short to allow a high sample throughput and to minimize resources. Column-switching HPLC after homogenization and protein precipitation served as an efficient, easy and rapid sample preparation method, followed by selective MS-MS detection. Optimization of the trapping procedure was performed in order to reduce the influence of endogenous interferences and to obtain good recovery. Chromatographic separation was necessary to increase the selectivity. The use of small analytical column dimensions (2.1 x 10 mm) was investigated to achieve higher sample throughput without compromising the assay quality. Mass spectrometric parameters, such as ionization modes (positive vs. negative) and ion source types (TurbolonSpray vs. APCI) were screened to find suitable conditions for sensitive analysis of the compounds. Matrix suppression effects were taken into consideration. Calibration samples were prepared in plasma only, whereas quality control samples were prepared in both plasma and tissues to save animals and time. Accuracy and precision were in the range of 84.4-119.1% and 1-16.5%, respectively. Limits of quantification were in the range of 0.5-2.5 ng/ml for plasma and 2-10 ng/ml for tissues. Run times as short as 2.2 min could be achieved.

Animals↗

In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples.

Recently, the on-line sample preparation technique, intube solid-phase microextraction (SPME), was successfully implemented with a Hewlett-Packard 1100 HPLC system for analysis of carbamates in water samples. This paper describes the coupling of in-tube SPME to capillary LC and explores its utility as a sample preparation method in that format, relative to conventional LC. The Hewlett-Packard HPLC system was upgraded to a capillary LC system using commercially available accessories from LC Packings. The combination of in-tube SPME with a capillary LC system was expected to build on the merits of both in-tube SPME and the capillary LC to generate a sensitive method with an easy, effective, and efficient sample preparation. Due to the relatively large effective injection volume of the in-tube SPME technique (30-45 microL), on-column focusing was employed in order to achieve good chromatographic efficiency. Excellent sensitivity was achieved with very good method precision. For all carbamates studied, the RSD of retention time was between 0.5 and 0.8% under 4 microL/min microgradient conditions. The RSD of peak area counts was between 1.5 and 4.6%. The detection limits for all carbamates studied were less than 0.3 microg/L and, for carbaryl, just 0.02 microg/L (20 ppt). Compared with the conventional in-tube SPME/LC method, the LODs were lowered for carbaryl, propham, methiocarb, promecarb, chlorpropham, and barban, by factors of 24, 45, 42, 81, 62, and 56, respectively. The optimized method was successfully applied to the analysis of carbamates in surface water samples.

Carbamates↗

Hydrazine decomposition over Irn/Al2O3 model catalysts prepared by size-selected cluster deposition.

Hydrazine decomposition chemistry was probed over a temperature range from 100 to 800 K for a series of model catalysts prepared by mass-selected Ir(n)(+) deposition on planar Al(2)O(3)/NiAl(110). Two sets of experiments are reported. Temperature-programmed desorption (TPD) was used to study hydrazine desorption and decomposition on Al(2)O(3)/NiAl(110) and on a model catalyst prepared by deposition of Ir(+) on Al(2)O(3)/NiAl(110) at a density large enough (5 x 10(14) cm(-2)) that formation of a distribution of small Ir(n) clusters on the surface is expected. This model catalyst was found to have hydrazine decomposition properties qualitatively similar to those observed on single-crystal Ir and polycrystalline Rh. This catalyst was also studied by X-ray photoelectron spectroscopy (XPS), to probe TPD-induced changes in the samples. A substantial decrease in the Ir XPS intensity suggests that considerable sintering takes place when the samples are heated to 800 K. In addition, a significant fraction of the nitrogen contained in the hydrazine is converted to an aluminum nitride (or mixed Al(x)O(y)N(z)) compound. Continuous flow experiments were used to probe relative reactivity at 300 and 400 K of samples prepared by depositing differently sized Ir(n)(+) clusters. At 300 K, samples prepared with preformed Ir(n)(+) (n = 5, 7, 10) are about twice as active, per Ir atom, as samples prepared with Ir(+) deposition, and there is a weaker trend to higher activity with increasing cluster size. At 400 K the trends are similar, but weaker, suggesting that thermal modification of the samples is already significant.

Journal Article↗

Optimised sample DNA preparation for detection of Chlamydia trachomatis in synovial tissue by polymerase chain reaction and ligase chain reaction.

OBJECTIVE: Molecular biology techniques such as polymerase chain reaction (PCR) and ligase chain reaction (LCR) are routinely used in research for detection of C trachomatis DNA in synovial samples, and these methods are now in use in some clinical laboratories. This study aimed at determining the method best suited to molecular diagnosis of C trachomatis by examining four standard DNA preparation methods using chlamydia spiked synovial tissue and chlamydia infected monocytes. METHODS: Synovial tissue from a chlamydia negative patient with rheumatoid arthritis was spiked with defined numbers of C trachomatis elementary bodies (EB). Purified human peripheral monocytes from normal donors were infected with the organism at a multiplicity of infection 1:1 in vitro and harvested after four days. DNA was prepared from all samples by four methods: (1) QIAmp tissue kit; (2) homogenisation in 65 degrees C phenol; (3) incubation at 97 degrees C; (4) proteinase K digestion at 97 degrees C. DNA from methods 1 and 2 was subjected to PCR using two different primer sets, each targeting the C trachomatis omp1 gene. LCR was done on DNA prepared by each method. RESULTS: In synovial tissue samples spiked with EB, and in monocytes persistently infected with the organism, preparation of template using the QIAmp tissue kit (method 1) and the hot phenol extraction technique (method 2) allowed sensitive detection of C trachomatis DNA. These methods also produced template from both sample types for LCR. DNA prepared by heat denaturation (method 3) allowed only low sensitivity chlamydia detection in LCR and did not work at all for PCR. Proteinase K digestion plus heat denaturation (method 4) gave template that did not allow amplification in either PCR or LCR assays. CONCLUSIONS: The sensitivity of detection for C trachomatis DNA in synovial tissue by PCR and LCR depends strongly on the method used for preparation of the amplification template. LCR targeting the multicopy chlamydial plasmid and two nested PCR assay systems targeting the single copy omp1 gene showed roughly equivalent sensitivity. Importantly, template preparation method and the specific PCR primer system used for screening must be optimised in relation to one another for highest sensitivity.

Chlamydia Infections↗

Analytical chromatography for recovery of small amounts of staphylococcal enterotoxins from food.

Sample preparation is an important element in the detection of toxins in food samples. In this work, a simple analytical sample preparation method for recovery of small amount of staphylococcal enterotoxin B (SEB) and staphylococcal enterotoxin A (SEA) in food samples was developed. Cation exchanger carboxymethylcellulose (CM) was used for small-scale batch chromatography isolation of SEB from infant formula and from mushrooms spiked with SEB. The resulting materials were analyzed for SEB by Western immunoblotting. Nearly all of the extraneous substances in the sample were removed by this procedure with no significant loss of the toxin. Using this method, even small amounts of SE (0.75 ng/g) can be recovered and immunologically analyzed by Western blotting or by ELISA with a very low background. Because this method is effective, rapid, simple and inexpensive, it has the potential to be a general method for the preparation of samples used for analysis of SEs.

Agaricales↗

Analytical evaluation of high energy phosphate determination by high performance liquid chromatography in myocardial tissue.

High performance liquid chromatography (HPLC) is an established method for the determination of myocardial high energy phosphates (HEP). Quantification of HEP compounds in small tissue specimens obtained by endomyocardial biopsy technique requires maximal sensitivity without impairment of precision. Employing isocratic ion-pair reversed-phase HPLC, high sensitivity and precision were obtained by running analyses for adenonucleotides and creatine compounds separately at detection wavelengths of 254 and 210 nm, respectively. Further reasons for separate runs were given by the necessity for different sample preparation as remaining perchloric ion after deproteinizing and pH in the samples had various effects on adenonucleotides and creatine compounds. Mechanical homogenization for 20 s in 0.42 mol/l perchloric acid ensured a consistent myocardial HEP extraction. Sample preparation directly following biopsy sampling is preferable since HEP compounds were labile in tissue within days at -80 degrees C even though an initial metabolic inhibition in liquid nitrogen had been induced. Following extraction and neutralization, HEP compounds were stable for up to 3 months at -20 degrees C.

Biopsy↗

Enumeration of CD4(+) T-cells in the peripheral blood of HIV-infected patients: an interlaboratory study of the FACSCount system.

The aim of the present study was to assess the interlaboratory reproducibility of the FACSCount system for the enumeration of peripheral blood (PB) CD4(+) T-cells. In each of the seven participating centers, both previously stained and unstained PB samples (n = 49) were received and either analyzed or stained and then analyzed. Interlaboratory reproducibility was checked in two different groups of centers (n = 3 and n = 4) where the study was performed in parallel. In addition, both the intralaboratory precision and accuracy of this system were analyzed in comparison with results obtained with conventional flow cytometry. Accordingly, upon comparing both methods, a high degree of correlation was observed in the total number of CD3(+) T-cells (coefficient of correlation of 0.9750 +/- 0.0184, slope of the best linear fit: 0. 9214 +/- 0.0311, y-intercept of 12 +/- 47) as well as in the number of CD3(+)/CD4(+) (coefficient of correlation of 0.9794 +/- 0.1457, slope of the best linear fit: 0.9463 +/- 0.0753, y-intercept of -11 +/- 36) and CD3(+)/CD8(+) (coefficient of correlation of 0.9728 +/- 0.0192, slope of the best linear fit: 0.9682 +/- 0.0735, y-intercept of 7 +/- 95) major subsets. In addition, low coefficients of variation (CV) were obtained for replicates, indicating the method's high degree of accuracy. The present study shows that with respect to the interlaboratory reproducibility reported for most techniques used for the enumeration of PB CD4(+) T-cells, the FACSCount system results in data with much lower coefficients of variance (CVs) (mean CV of less than 10%). Upon measuring the impact on results of different variables associated with either sample preparation or data acquisition and analysis, our study clearly shows that data acquisition and analysis does not influence the results by increasing variability since the coefficients of variation obtained for samples prepared in the same laboratory under the same conditions and read in different laboratories with different instruments were identical to those obtained for the replicates of the same samples read in each individual center. In contrast, interlaboratory variability, although low, significantly increased when sample preparation was carried out in different laboratories, suggesting that pipetting still represents the major source of variability in the FACSCount system.

CD4 Lymphocyte Count↗

Effective removal of Ga residue from focused ion beam using a plasma cleaner.

Samples prepared using the focused ion beam (FIB) inevitably contain the surface damage induced by energetic Ga+ ions. An effective method of removing the surface damage is demonstrated using a plasma cleaner, a device which is widely used to minimize the surface contamination in scanning transmission electron microscopy (STEM). Surface bombardment with low-energy Ar+ ions was induced by biasing the sample immersed in the plasma source, so as to etch off the surface materials. The etch rates of SiO2, measured with a bias voltage of 100-300 V, were found to vary linearly with both the time and bias and were able to be controlled from 1.4 to 9 nm/min. The removal of the Ga residue was confirmed using energy dispersive spectroscopy (EDS) after the plasma processing of the FIB-prepared sample. When the FIB-prepared sample was processed via plasma etching for 10 min with a bias of 150 V, the surface Ga damage was completely removed.

Journal Article↗

Methods for generating protein molecular ions in ToF-SIMS.

One of the greatest challenges in mass spectrometry lies in the generation and detection of molecular ions that can be used to directly identify the protein from the molecular weight of the molecular ion. Typically, proteins are large (MW > 1000), nonvolatile, and/or thermally labile, but the vaporization process produced by many mass spectrometry techniques including time-of-flight secondary ion mass spectrometry (ToF-SIMS) is inherently limited to generating ions from smaller compounds or fragments of the parent molecule, making the identification of proteins complex. The application of specific molecules to aid in the generation of high molecular weight ions in ToF-SIMS has been recognized for some time. In this study we have developed a matrix-SAM substrate preparation technique based on the self-assembly of a matrix-like molecule, mercaptonicotinic acid (MNA), on gold. We then compare this substrate with two existing ToF-SIMS sample preparation techniques, cationized alkane thiol and matrix-enhanced SIMS (MESIMS). The results of this study illustrate that while there is a range of methods that can be used to improve the molecular ion yield of proteins in ToF-SIMS, their efficacy and reproducibility vary considerably and crucially are linked to the sample preparation and/or protein application methods used. Critically, the MNA modified substrate was able to simultaneously induce molecular ions for each protein present in a multicomponent solution, suggesting that this sample preparation technique may have future application in proteomics and DNA analysis.

Gold↗

Preparation and characterization of chemically defined oligomers of rabbit immunoglobulin G molecules for the complement binding studies.

Pure dimers, trimers, tetramers and pentamers of rabbit non-immune IgG (immunoglobulin G) or antibody IgG were prepared by polymerization in the presence of the bifunctional cross-linking reagent dithiobis (succinimidylpropionate). Oligomerization was performed either in the presence of polysaccharide antigen and specific monomeric antibody (method A) or by random cross-linking of non-immune rabbit IgG in the absence of antigen (method B). By repeated gel-filtration chromatography, samples prepared by both methods exhibited a single band in analytical sodium dodecyl sulphate/polyacrylamide-gel electrophoresis. The electrophoretic mobilities of samples prepared by method A were slightly greater than those for the corresponding samples prepared by method B. This might suggest a role played by antigen in the orientation of IgG molecules within the clusters, which may be more compact than those formed by random cross-linking. The average numbers of cross-linker molecules per oligomer varied between 3 and 6 for clusters made by method A and between 1 and 3 for clusters made by method B. Ultracentrifugal analyses of the oligomers yielded sedimentation coefficients (S20,w) of 9.6S for the dimer, 11.2S for the trimer, 13.6S for the tetramer and 16.1S for the pentamer. Comparison of the observed sedimentation coefficients with those predicted by various hydrodynamic models suggested these oligomers possessed open and linear structures. Reduction of the cross-linking molecules converted oligomers into monomeric species of IgG. C.d. spectra of some oligomers studied in the range 200-250 nm were essentially the same as that of monomeric IgG molecules, thus strongly suggesting no major conformation changes in IgG molecules within clusters. These oligomers were found to be stable for up to 2 months when stored at -70 degrees C.

Animals↗