Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Determination of 3-trifluoromethyl-4-nitrophenol and 3-trifluoromethyl-4-nitrophenol glucuronide in edible fillet tissue of rainbow trout and channel catfish by solid-phase extraction and liquid chromatography.

3-Trifluoromethyl-4-nitrophenol (TFM) is a pesticide used for the selective control of sea lampreys (Petromyzon marinus) in stream and river tributaries of the Great Lakes. To determine concentrations of TFM and TFM glucuronide in the edible fillet tissue of fish during sea lamprey control treatments, an analytical method was developed to determine the concentrations of these residues in rainbow trout (Oncorhynchus mykiss; RBT) and channel catfish (Ictalurus punctatis; CCF). Homogenized fillets were extracted with methanol-water (80 + 20). TFM and TFM glucuronide were isolated from coextractives by C18 solid-phase extraction. TFM glucuronide was hydrolyzed to TFM by the addition of beta-glucuronidase to the TFM glucuronide extract. The extracts were analyzed separately by liquid chromatography with UV-visible detection. Recoveries from TFM-fortified CCF and RBT tissues were 84.1 and 96.1%, respectively. The method detection limits (MDLs) are 2.4 ng/g for TFM-fortified tissues of CCF and 3 ng/g for those of RBT. Recoveries were 78.8 and 77% from TFM glucuronide-fortified CCF and RBT tissues, respectively. The MDLs for TFM glucuronide-fortified tissues are 3.5 and 6.9 ng/g for CCF and RBT, respectively.

Animals↗

Sensitive triple-quadrupole mass spectrometric assay for the determination of BMS-181885, a 5-HT1 agonist, in human plasma following solid phase extraction.

A sensitive, selective, accurate, precise and reproducible triple-quadrupole liquid chromatographic-mass spectrometric assay was developed and validated for BMS-181885 (I), a 5HT1 agonist, in human plasma using BMS-181101 as the internal standard (IS). The method involved solid phase extraction of plasma containing I and the IS using Isoelute CN cartridges. The supernatant was then evaporated to dryness at 40 degrees C. The residue was dissolved in 100 microL of the injecting solvent. The HPLC column was ODS-3, 2 x 100 mm. The mobile phase comprised 10 mM ammonium formate (pH = 4) and acetonitrile, 55:45 v/v, used in an isocratic condition. The mass spectrometer was programmed to admit the protonated molecules at m/z 461 (I) and m/z 370 (IS) via the first quadrupole filter and to select reaction monitoring of ions at m/z 152 for I and IS for the quantification. Standard curves were fitted to a weighted quadratic function over the concentration range 0.2-200 ng/mL. The lowest standard concentration (0.2 ng/mL) was experimentally established as the lower limit of quantitation of the assay. The mean predicted quality control concentrations deviated within +/- 11% of the corresponding nominal values; the intra-assay and inter-assay precisions were within 7.0% relative standard deviation. I was stable in the injection solvent at 4 degrees C for at least 24 h and for at least three freeze-thaw cycles. Freezer stability of I in plasma was demonstrated for at least 3 months. The extraction recovery of I was established as 97%. The validated assay was applied to a pharmacokinetic study of I in humans.

Analysis of Variance↗

Determination of fluorescent whitening agents in environmental waters by solid-phase extraction and ion pair liquid chromatography-tandem mass spectrometry.

A comprehensive method for the trace determination of four stilbene-type disulfonate and one distyrylbiphenyl-type fluorescent whitening agents (FWAs) in environmental water samples was developed and validated. Various solid-phase extraction (SPE) cartridges were investigated. The newly developed Oasis WAX (weak mixed-mode anion exchange and reversed-phase sorbent) SPE cartridge provides the optimal sample extraction results. The analytes were then identified and quantitated by liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS-MS) in negative ionization mode, applying di-n-hexylammonium acetate (DHAA) as the ion-pairing reagent in mobile phase. Limits of quantitation (LOQs) were established between 4 and 18 ng/l in 50 ml of water samples. Intrabatch and interbatch precision with their accuracy at two concentration levels were also investigated. Precision for these five FWAs, as indicated by RSD, proved to be less than 13 and 11%, respectively, for intra- and interbatch. Accuracy, expressed as the mean recovery, was between 68 and 97%. The method was finally applied to environmental water samples, showing the occurrence of five FWAs in both river water and wastewater treatment plant (WWTP) effluent samples.

Chromatography, High Pressure Liquid↗

Solid-phase extraction and sample stacking-capillary electrophoresis for the determination of quaternary ammonium herbicides in drinking water.

Conditions for the simultaneous determination of paraquat, diquat and difenzoquat by capillary zone electrophoresis were established by combining two preconcentration procedures. Off-line solid-phase extraction was used for the isolation and preconcentration of quats in drinking water. Quats were then analysed by capillary electrophoresis using sample stacking with matrix removal as on-column preconcentration procedure. Two different porous graphitic carbon cartridges were compared. The breakthrough volumes of the three herbicides were calculated and the loading capacity of the sorbents was compared. Recoveries higher than 80% for difenzoquat and around 40% for paraquat and diquat were obtained when a sample volume of 250 ml was percolated. For the stacking-capillary electrophoresis analysis of quats, 50 mM acetic acid-ammonium acetate (pH 4.0), 0.8 mM cetyltrimethylammonium bromide with 5% (v/v) methanol as carrier electrolyte was used. Detection limits, based on a signal-to-noise ratio of 3:1, were lower than 0.3 microg l(-1) for standards in Milli-Q water, and lower than 2.2 microg l(-1) for drinking water samples. Run-to-run and day-to-day precision of the method were established. The two preconcentration procedures used together was successfully applied to the analysis of the three herbicides in spiked drinking water at concentrations below the maximum admissible US Environmental Protection Agency levels.

Electrophoresis, Capillary↗

Determination of palladium in human urine by high-performance liquid chromatography and ultraviolet detection after ultraviolet photolysis and selective solid-phase extraction.

The high-performance liquid chromatographic method with UV detection described below permits the selective determination of traces of palladium in human urine. After UV photolysis, during which the complete organic matrix was destroyed, the palladium was selectively enriched by solid-phase extraction (SPE). The reversed-phase C18 SPE column material was loaded with the ligand N,N-diethyl-N'-benzoylthiourea (DEBT) which shows an excellent complexing capacity for palladium in acidic solutions and at room temperature. The Pd(DEBT)2 complex was eluted with ethanol. After isocratic separation on the analytical column (MeOH/H2O 98:2 (v/v)), the complex was detected at 274 nm. The detection limit was 10 ng Pd/l. The relative standard deviations (RSD) of the within-series imprecision were in the range between 11% (75 ng Pd/l) and 7% (180 ng Pd/l). The between-day imprecision was 11% (75 ng Pd/l) and 5% (180 ng Pd/l). The recovery rates ranged between 94 and 96%. Using this method, urine samples of 44 persons from the general population were analysed. Only in one urine sample could palladium be detected. For comparison, 10 persons with occupational palladium exposure were examined. The urinary concentrations ranged from <10 to 2,538 ng/l.

Calibration↗

Determination of nifedipine in human plasma by solid-phase extraction and high-performance liquid chromatography: validation and application to pharmacokinetic studies.

Nifedipine, a dihydropyridine calcium channel antagonist, is widely used in the treatment of hypertension and other cardiovascular disorders. A simple, rapid, sensitive, precise and accurate HPLC method, using solid-phase extraction, for the quantitation of nifedipine in human plasma was developed and validated. The calibration graphs were linear in the 5-400 ng/ml concentration range (r>0.999). Recovery for nifedipine was greater than 93.9% and for internal standard nitrendipine was 96.1%. Intra-day and inter-day precision ranged from 1.4 to 4.2 and 3.9 to 5.6%, respectively. Intra-day and inter-day accuracy was ranged from 94.5 to 98.0 and 93.1 to 98.0%, respectively. The method was not interfered with by other plasma components and was applied for the determination of nifedipine in pharmacokinetic study after single oral administration of 10 mg nifedipine to 18 healthy male subjects.

Adult↗

Analysis of multiple endocrine disruptors in environmental waters via wide-spectrum solid-phase extraction and dual-polarity ionization LC-ion trap-MS/MS.

An analytical method for the determination of 35 endocrine disrupting chemicals (EDCs) present in the aquatic environment was developed and validated. The procedure includes an off-line solid-phase extraction of 500-mL water samples using wide-spectrum polymer packing material combined with two LC-ESI-MS/MS runs, in negative and positive ionization modes. Limits of quantitation were established between 0.1 and 20.0 ng/L. Satisfactory recoveries were obtained ranging from 80.1 to 110.2%. Calibration, using deuterated internal standardization, was performed by linear regression analysis. Linearity (R(2) > 0.99) was demonstrated over individually specified ranges using seven calibration points for each analyte. Intrabatch and interbatch precision, as well as accuracy (n = 5), were investigated at low, medium, and high concentrations. Precision for all compounds, expressed as the RSD, proved to be less than 17.8 and 20.0%, respectively, for intra- and interbatch. Accuracy, expressed as the mean recovery, was between 83.1 and 108.4% at all concentrations. Stability experiments showed no significant loss or deterioration for any of the analytes. Finally, the method was applied on real samples.

Animals↗

Determination of mercapturic acids in urine by solid-phase extraction followed by liquid chromatography-electrospray ionization mass spectrometry.

A novel method for the determination of five kinds of mercapturic acids, found in urine as metabolites of alkylbenzenes, based on liquid chromatography-electrospray ionization mass spectrometry is described. A solid-phase extraction procedure was used for the extraction of the mercapturic acids from urine and the separation was performed on a reversed-phase C30 column. The detection limits were in the range 2.4-3.2 ng ml-1.

Acetylcysteine↗

Simultaneous quantitation of opioids in blood by GC-EI-MS analysis following deproteination, detautomerization of keto analytes, solid-phase extraction, and trimethylsilyl derivatization.

Seven opioid analytes including codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone, and oxymorphone were detected in postmortem blood (n > 1000). Two milliliters of specimen was deproteinated with approximately 2.5 mL of methanol and derivatized with hydroxylamine before solid-phase extraction and derivatization with BSTFA + 1% TMCS. Extracts were assayed by gas chromatography-electron impact-mass spectrometry utilizing selected ion mode. One-microliter aliquots were injected onto an HP-1MS capillary column (30 m x 0.25-mm i.d., 0.25 microm) with a helium linear velocity of 62 cm/s. Temperature programming began at 160 degrees C (hold 0 min), then increased at rates of 35 degrees C/min to 195 degrees C, 5 degrees C/min to 240 degrees C, and 30 degrees C/min to 300 degrees C (hold 2 min) resulting in a total run time of 14-min. Quantitative determinations were based on the ratios of the analyte peak areas to the corresponding deuterated analogues. Calibration curves were linear for the following concentrations: 10-500 ng/mL (6-AM), 100-2000 ng/mL (oxycodone), and 50-1000 ng/mL (all other opioids). LOQs ranged from 5 ng/mL (6-AM) to 20 ng/mL (oxycodone). Between-run precision yielded CVs ranging from 2.79% to 5.34% (n = 12). These data suggest that methanolic deproteination and dual derivatization improve separation and simultaneous quantitation of seven opioid analytes in difficult matrices.

Forensic Medicine↗

Determination of phenoxyalkanoic acids and other herbicides at the ng/ml level in water by solid-phase extraction with poly(divinylbenzene-co-N-vinylpyrrolidone) sorbent and high-performance liquid chromatography--diode-array detection.

A method for the determination of phenoxyalkanoic acids and other polar compounds in environmental water samples without pH adjustment before extraction has been developed. Recoveries were calculated from 500 ml of milliQ water spiked at the level of 0.5 ng/ml using solid-phase extraction (SPE) and HPLC-DAD. Different SPE materials (RP-C18, ENV+, ENV+-C8, SAX and Oasis HLB) were tested. After method optimization, 15 of the 16 compounds studied could be extracted with recoveries better than 70% on the most suitable copolymeric poly(divinylbenzene-co-N-vinylpyrrolidone) material (Oasis HLB cartridges).

Chromatography, High Pressure Liquid↗

Quantification of sifuvirtide in monkey plasma by an on-line solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry.

A simple, automated and rapid method has been developed for the determination of a novel antiviral peptide sifuvirtide in monkey plasma. Raw plasma samples were directly loaded onto an on-line solid-phase extraction (SPE) column, which removes the time-consuming and laborious sample pretreatment. Following a timed valve-switching event, the analyte was eluted on-line to a reversed-phase high-performance liquid chromatography (RP-HPLC) column and subsequently introduced into a linear ion trap mass spectrometer, LTQ-MS, via an electrospray ionization (ESI) interface. The multiply charged peptides were specified and quantitatively analyzed using selective reaction monitoring (SRM). A highly pure four iodine-sifuvirtide was synthesized using an optimized iodogen method and proved to be a suitable internal standard (IS). A single analysis run takes about 18 min. Validation of the method demonstrated that the linear calibration curves covered the range of 4.88-5000 ng/mL, and the correlation coefficients were above 0.9923. The limit of detection (LOD) with the signal-to-noise (S/N) ratio higher than 12 was calculated as 1.22 ng/mL. The intra- and inter-batch precisions were less than 12.7% and 9.1%, and the mean accuracy ranged from -5.2% to 3.6%, respectively. Any carry-over effect from the system was negligible. In a pharmacokinetic (PK) study of sifuvirtide after a single intravenous or subcutaneous dose in monkeys, the on-line SPE-LC/MS/MS system was successfully utilized to determine hundreds of samples with only one extraction column, which indicated the feasibility and the reliability of this method for application in preclinical and clinical PK studies of peptide drugs.

Amino Acid Sequence↗

Simultaneous determination of carisoprodol and meprobamate in human hair using solid-phase extraction and gas chromatography/mass spectrometry of the trimethylsilyl derivatives.

Carisoprodol (CSP) is a musculoskeletal relaxant whose active metabolite is meprobamate (MPB). This drug has recently been noticed to be abused as an inexpensive alternative to illicit drugs in Korea. A method using solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) was developed for the determination of CSP and MPB in human hair. Hair samples (30 mg) were washed with distilled water and acetone, cut into small fragments (<1 mm), incubated in 1.0 M HCl overnight at 50 degrees C, and then adjusted to pH 6.5. The drugs were extracted from the resulting hydrolyzed solutions using a SPE column. The eluents were evaporated to dryness, then derivatized using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) at 120 degrees C for 30 min. The derivatized extract (1 microL) was injected into the GC/MS system. Recoveries were in the range of 91.5-93.1% for CSP and 85.5-93.0% for MPB. The linear ranges were 0.5-10.0 ng/mg for both CSP and MPB with good correlation coefficients (r(2) = 0.995). The intra-day precision and accuracy ranged from 1.5 to 9.3% and -17.5 to 3.6%, respectively, and the inter-day precision and accuracy ranged from 3.9 to 6.2% and -15.0 to -3.9%, respectively. The limits of detection for CSP and MPB were 0.13 and 0.12 ng/mg, respectively. The applicability of the method was proven by analyzing a hair sample from an authentic abuser.

Adult↗

High precision procedure for determination of selected herbicides and their degradation products in drinking water by solid-phase extraction and gas chromatography-mass spectrometry.

For target monitoring of selected herbicides in groundwater transport studies, a precise and accurate method for the determination of atrazine (ATR), desethylatrazine (DEAT) and 2,6-dichlorobenzamide (BAM) was developed. The method is based on solid-phase extraction and GC-MS analysis. Deuterated standards are used as surrogates for calibration by the overall procedure. For legal requirements the method described was validated and is regularly subject to external quality control. Typical limits of detection are 2 ng/l. Uncertainty contributions were evaluated using the GUM workbench modelling software. At the concentration level of interest (100 ng/l), an expanded uncertainty of no more than 10% was estimated. Accurate data on the distribution of ATR, DEAT and BAM in affected well fields enabled operational changes to be implemented to control the drinking water supply according to legal requirements.

Chromatography, Liquid↗

Sample preparation on polymeric solid phase extraction sorbents for liquid chromatographic-tandem mass spectrometric analysis of human whole blood--a study on a number of beta-agonists and beta-antagonists.

Alternative strategies for sample preparation of human blood samples were evaluated including protein precipitation (PP) and solid phase extraction (SPE) on Waters Oasis polymeric columns. Gradient chromatography within 15 min was performed on a Hypersil Polar-RP column combined with a Sciex API 2000 triple quadrupol instrument equipped with an electro-spray interface. Beta-agonists and beta-antagonists available on the Swedish market were included in the study. A combination of zinc sulphate and ethanol was found effective for PP. A clear supernatant was achieved that either could be injected directly on the LC-MS-MS system for analysis or transferred to a SPE column for further extraction and analyte concentration. Retention on the hydrophilic-lipophilic balanced sorbent HLB as well as the mixed mode cationic MCX and anionic MAX sorbents were investigated. On HBL the relative lipophilicity of the target analytes was investigated. At a high pH when the amino alcohols are deprotonised the more non-polar analytes (e.g., carvediol, betaxolol, bisoprolol and propranolol) were well retained on the sorbent and for the majority methanol content higher than 50% in water (v/v) was needed for elution. Some analytes though, with additional weak acidic functionalities (fenoterol, salbutamol, sotalol, and terbutaline) were poorly retained. On MAX the retention of these weak acids was improved when loaded under basic conditions but under neutral conditions analyte recoveries was comparable with HLB. On MCX all the analytes were well retained allowing a wash step of 100% methanol at neutral and low pH. By applying the supernatant from PP in combination with an additional portion of aqueous formic acid (2%) the analytes could be loaded and retained. High extraction recoveries were found for most analytes but for a few, significant losses were seen during PP (e.g., formoterol) and/or evaporation (e.g., fenoterol, formoterol, labetalol and terbutaline). The effectiveness of the sample preparation was evaluated by ESI ion-suppression studies by post column infusion of the target analyte. An ethanol zinc sulphate aq mixture was found to be more effective than acetonitrile, methanol or ethanol for PP of human whole blood samples. Beside suppression by salts in the front peak, only limited suppression from other artefacts such as more lipophilic compounds was found late in the chromatograms. Some tendency though to concentrate more lipophilic artefacts on the Oasis sorbents was seen. These findings show that the Oasis MCX sorbent is well suited for sample preparation of beta-agonists and beta-antagonists from human whole blood if the objective is to cover a great number of the analytes in the same assay.

Adrenergic beta-Agonists↗

Determination of apovincaminic acid in human plasma by high-performance liquid chromatography using solid-phase extraction and ultraviolet detection.

A new, simple and rapid high-performance liquid chromatography (HPLC) method with UV detection has been developed for the determination of apovincaminic acid in human plasma. Apovincaminic acid and internal standard were isolated from plasma samples by solid-phase extraction with OASIS HLB cartridges. The chromatographic separation was accomplished on a reversed-phase C(18) column and UV detection was set at 311 nm. The calibration curves were linear in the concentration range of 2.4-240.0 ng/ml, and the limits of quantification was 2.4 ng/ml. The precision and accuracy ranged from 0.84 to 8.54% and 91.5 to 108.3%, respectively. The developed method was subsequently applied to study the pharmacokinetics of apovincaminic acid in a group of 20 human subjects at a single oral dose of 10mg of vinpocetine tablet.

Calibration↗

Molecularly imprinted polymer microspheres for solid-phase extraction of chloramphenicol residues in foods.

Preparation of molecularly imprinted polymer microspheres (MIPMs) for chloramphenicol (CAP) by aqueous suspension polymerization is reported for the first time in this study. The resulting MIPMs had the ability to specifically adsorb CAP, and the molecularly imprinted solid phase extraction (MISPE) based on the MIPMs was shown to be applicable for clean-up and preconcentration of trace CAP in milk and shrimp samples with high recoveries of 92.7% and 84.9%, respectively. Combined with MISPE, the conventional HPLC-UV analysis sensitivity for CAP in foods could be significantly increased.

Adsorption↗

Determination of rice herbicides, their transformation products and clofibric acid using on-line solid-phase extraction followed by liquid chromatography with diode array and atmospheric pressure chemical ionization mass spectrometric detection.

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 ml of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination. For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the 3-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples.

Atmospheric Pressure↗

Selective solid-phase extraction sorbent for caffeine made by molecular imprinting.

A molecularly imprinted polymer (MIP) was prepared with caffeine as the template molecule. Thermal polymerisation (60 degrees C) was optimised, varying ratios of monomer, cross linker and template. The polymer was used as a solid-phase extraction (SPE) sorbent, for selective trapping and pre-concentration of caffeine. Caffeine was loaded on the MIP-SPE cartridge using different loading conditions (solvents, pH value). Washing and elution of the caffeine bound to the MIP was studied utilising different protocols. The extraction protocol was successfully applied to the direct extraction of caffeine from beverages and spiked human plasma.

Beverages↗