Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Reference Standards”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Improved performance of hip DXA using a novel region of interest in the upper part of the femoral neck: in vitro study using bone strength as a standard of reference.

We tested the hypothesis that bone mineral density (BMD) and bone mineral content (BMC) in proximal human femur specimens in the upper neck region of interest (ROI) and femoral neck axis length (FNAL) provide a significantly better prediction of femoral bone strength than standard ROIs in vitro. BMD and BMC were measured in 110 proximal femur specimens using a standard dual-energy X-ray absorptiometry (DXA) scanner. The analysis included a new ROI in the upper neck as well as the standard ROIs. FNAL was obtained from the scan images. The specimens' failure-load was measured in a mechanical loading device, simulating a fall on the greater trochanter. For the standard ROIs, correlations between failure-load and BMD ranged from R2 = 0.64 (shaft ROI) to R2 = 0.70, p < 0.001 (femoral neck). Prediction of strength by BMD did not significantly differ from those of BMC (R2 ranging from 0.65 to 0.75, p < 0.001). In the upper neck ROI, for both BMD and BMC correlations with failure-load were higher (R2 = 0.76 and 0.81, respectively; p < 0.001). A lower, yet still significant, correlation was found between FNAL and bone strength (R2 = 0.23, p < 0.001). Normalization of failure-load with respect to FNAL did not significantly increase the correlations with densitometric measures. This study provides in vitro evidence indicating that among the ROIs of the proximal femur the newly defined upper neck ROI provides the best prediction of bone strength. Only a weak association was observed between failure load and FNAL.

Absorptiometry, Photon↗

Precision of DNA flow cytometry in inter-institutional analyses.

A Bladder Cancer Flow Cytometry Network study has been carried out to further identify and quantify sources of inter- and intra-laboratory variability. Replicate samples containing four mixtures of peripheral blood lymphocytes and aneuploid cell lines were distributed together with reference standards to six laboratories. The samples were stained for DNA using propidium iodide, with each laboratory using its own staining protocol. Two of each of the four sample types and a reference standard were analyzed by each laboratory on 3 separate days to obtain cellular DNA distributions. DNA index (DI) and hyperdiploid fraction (HDF) were calculated for each histogram using an automated technique. The results showed significant inter- and intra-laboratory differences. Results were evaluated by a two-way analysis of variance to estimate components of the overall variation attributable to individual sources. Error variation was found to be the major component of random variation. Specimen means were also compared for each laboratory. No significant differences were noted in mean DI for similar specimens; however, agreement in HDF between similar specimens was lacking in most laboratories. Prediction intervals were computed to estimate the range of values expected for a single specimen based on the analysis of the previous six. Prediction intervals for DI were quite good while those for HDF were troublesome due to wide variation. The results of these studies indicate that intra- and inter-laboratory variability are high enough that results for a single sample may not be sufficiently precise to allow comparison to results obtained in other laboratories.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

Diagnosis of iron deficiency anemia in renal failure patients during the post-erythropoietin era.

The purpose of this study was to evaluate the sensitivity and specificity of laboratory methods in the diagnosis of posterythropoietin-era, iron-deficient, chronic renal failure patients. The patient population comprised 25 anemic (hemoglobin < 11 g/dL) patients with creatinine greater than 3 mg/dL; 20 were dialysis patients, two were transplant patients, and three patients had renal failure from other causes. Criteria for study inclusion were as follows: bone marrow iron was the reference standard and was graded 0 to +4, ranging from absent to diffuse homogeneous iron staining; serum ferritin concentration and serum transferrin saturation were tested in terms of sensitivity and specificity. The reference standard indicated that iron deficiency existed in 40% of patients. Neither serum ferritin nor transferrin saturation were completely adequate diagnostic tools. Serum ferritin levels less than 200 ng/dL were 100% specific for the diagnosis but only 41% sensitive. Transferrin saturation of less than 20% was 88% sensitive, but only 63% specific. By excluding patients with hypoproteinemia (transferrin values of < 150 mg/dL), the sensitivity of the test increased to 100% and the specificity to 80%. We conclude that transferrin saturation is an adequate screening tool in anemic chronic renal failure patients, provided that hypoproteinemia is not present. By determining both the serum ferritin concentration and the transferrin saturation, a high sensitivity and specificity can be achieved, even in patients with hypoproteinemia. Furthermore, we believe that on this basis, iron therapy in patients with renal insufficiency can be improved.

Adult↗

Synthesis and gastric antisecretory properties of 15-deoxy-16-hydroxyprostaglandin E analogues.

The preparation and gastric antisecretory activity of a series of 15-deoxy-16-hydroxyprostaglandin analogues are described. The compounds were tested intravenously in histamine-stimulated Heidenhain pouch dogs in relation to the reference standards PGE1 and PGE1 methyl ester (PGE1ME). The parent compound of this seris, (+/-)-15-deoxy-16alpha,beta-hydroxyprostaglandin E1 methyl ester (3), was found to be equipotent to the reference standard PGE1ME. Methylation at C-16 of 3 produced 8 which was found to be some 40 times more potent than PGE1. In sharp contrast, addition of two methyl groups to 3 at C15 or C17 markedly reduced the antisecretory action. The 16-ethyl analogue of 3 also showed reduced potency. Removal or epimerization of the C-11 hydroxy group of 8 reduced the activity. Likewise, hydrogenation or changing the stereochemistry of the 13,14 double bond from trans to cis decreased the activity. On the other hand, omega-homologation of 8 or the introduction of a cis-5,6 double bond did not affect the potency. From these studies, it appears that 8, 16, and 17 possess optimum gastric antisecretory effects in this series.

Animals↗

Interobserver variation in the evaluation of radiologic changes of rheumatoid arthritis.

The variation between four radiologists in the evaluation of hand, wrist, and foot radiographs of rheumatoid arthritis was examined. The recognition of individual radiologic changes varied considerably as judged by the findings of the different observers. Erosion and joint space narrowing were interpreted more uniformly than soft tissue swelling and osteoporosis. When the radiographs were graded from 0 to 5 using standard reference radiographs, more than 90% of them were graded uniformly or with a difference of only one grade. The investigation has shown that when applying grading of rheumatoid arthritis according to standard reference radiographs, the interobserver variation is considerably less than when pure individual radiological changes of rheumatoid arhtritis are considered.

Adult↗

Synthesis, cytotoxic and antiviral activity of uracils containing 5-(1-hydroxy-2-haloethyl)- and 5-(1-methoxy-2-haloethyl) substituents.

5-(1-Hydroxy-2-haloethyl)- (4), 5-(1-methoxy-2-haloethyl)- (5) and 5-(1-hydroxy-2-methoxyethyl)uracils (6) (see Figure 2 for structures) were synthesized to investigate the effect of the C-5 substituents on cytotoxic and antiviral activity. The bromo compounds (4b and 5b) exhibited greater cytotoxic activity than the chloro or iodo analogues in the in vitro L1210 assay. Replacement of the hydroxyl substituent of 4b (bromo) and 4c (iodo) by a methoxyl substituent (5b-c), or substitution of their halogen substituents by methoxyl (providing 6) increased the potency. However, the cytotoxic activity of all the compounds was weak, the most active (6) producing a 45% decrease in cell survival at a concentration of 50 micrograms/ml, as compared with a 97% decrease when the reference standard (melphalan) was tested at 1 microgram/ml. They were inactive antiviral agents against herpes simplex virus type 1 (HSV-1) infected Vero cells at 10 micrograms/ml; in the same test, the reference standard (acyclovir) exhibited an ID50 of 0.01 micrograms/ml.

Animals↗

Pharmacokinetics and tissue distribution of rifametane, a new 3-azinomethyl-rifamycin derivative, in several animal species.

Single and repeated dose experiments in mice, rats, dogs and monkeys are reported in this study to assess the pharmacokinetics and tissue distribution of rifametane, a new semi-synthetic rifamycin with the chemical formula 3-[(1-diethylaminoethylidene)azinomethyl]rifamycin SV (CAS 94168-98-6, SPA-S-565). All the kinetic tests were carried out in comparison with known rifamycin derivatives, as rifampicin (CAS 13292-46-1) or rifamycin SV (CAS 6998-60-3). Mice received single i.v. and oral administration of 10 mg/kg of rifametane or of rifampicin and serum samples were obtained up to 96 h after dosing. The two antibiotics showed similar peak of serum concentrations, but rifametane showed a longer half-life and higher AUC values. In an additional experiment, the tissue/serum ratio after the 10 mg/kg oral dose was lower than unity for lungs and kidneys, while the liver/serum ratio exceeded the unity at all sampling times. After 4 weeks of once weekly administration measurable serum and tissue concentrations were observed, and after twice weekly administration for the same time period some blood and tissue accumulation was seen. Rats were treated with a single intravenous injection of 20 mg/kg of rifametane or rifampicin and with single oral or i.m. administration of 60 mg/kg of rifametane or reference standards (rifampicin and rifamycin SV resp.), in two separate trials. The serum half-life of the test antibiotic after i.v. dose was 6 times longer than that of rifampicin and the serum concentrations of rifametane after oral and i.m. doses were higher and longer-lasting than those of the reference compounds. Repeated daily administrations of rifametane at three dose levels (3, 10, 30 mg/kg p.o.) for 4 weeks induced very high serum and liver concentrations. Dogs received a single oral dose of 1.25 mg/kg of rifametane or 2.5 mg/kg of rifampicin. The serum half-life of rifametane resulted 3 times longer than that of rifampicin. Remarkable serum and tissue concentrations were observed after 3-4 weeks of daily oral administration of rifametane at 3, 10, 30 mg/kg dose. Monkeys were given single oral or i.m. administration of 30 mg/kg of rifametane or reference standards (oral rifampicin and i.m. rifamycin SV). The serum concentrations after rifametane were higher and more sustained than those of reference compounds and the half-lives of the test antibiotic were about 2.5 (p.o.) to 6 times (i.m.) longer. The urine excretion of rifametane after a single intravenous dose in rats and a single oral dose in dogs was very low, while rifampicin had a little higher urine concentrations.

Administration, Oral↗

Stool antigen testing for the diagnosis and confirmation of eradication of Helicobacter pylori infection: a prospective blinded trial.

BACKGROUND AND AIMS: Helicobacter pylori is an established pathogen for a wide spectrum of gastroduodenal diseases. We investigated the usefulness of H. pylori stool antigen test (HpSA) before and after eradication therapy on patients referred for gastroscopy. METHODS: Over a 12-month period, 127 adult patients (47% males) underwent HpSA and gastroscopy with dual biopsies from the antrum and proximal body of the stomach for urease and histology. The positive patients (histology, urease or combined positive) received triple therapy consisting of clarithromycin 500 mg, amoxycillin 1 g and omeprazole 20 mg, each given twice daily for 7 days. Six weeks post-therapy, eradication was verified with the 13C-urea breath test (UBT) and the HpSA results compared on a second stool sample. RESULTS: Pre-therapy, 23/113 patients were positive by urease test, 22/112 by histology and 22/112 were combined positive. For the HpSA, compared to combined urease and histology as the reference standards, the sensitivity and specificity were 79 and 92% while the positive and negative predictive values (PPV and NPV) were 68 and 96%, respectively. Post-therapy, UBT was adopted as the reference standard and 18 paired samples were available for analysis: three were positive and 15 were negative. Sensitivity and specificity were 67 and 100% while the PPV and NPV were 100 and 94%, respectively. CONCLUSIONS: In this prospective study, HpSA was found to be a reasonably useful diagnostic test for H. pylori infection. Post-eradication, it was highly specific and similar to UBT in terms of PPV and NPV. The test is non-invasive and cheaper than the urease test or the UBT, making it a candidate in the investigation of dyspepsia.

Adolescent↗

Longitudinal fetal biometry of normal pregnant Melanesian Papua New Guineans to construct standards of reference for Papua New Guinea.

In a longitudinal study at the Port Moresby General Hospital Antenatal Clinic between May 1990 and December 1991, 1514 biparietal diameter (BPD), 1294 femur length (FL) and 1229 abdominal circumference (AC) measurements were made on 425 fetuses during normal pregnancy. Weekly mean values with 2 standard deviations were calculated for BPD, FL and AC between 12 and 42 weeks. Growth curves were also constructed. Ethnic origin, height, parity, weight gain per week and socioeconomic status made no difference to these measurements. The mean values for BPD were compared with those obtained from studies in Africa and Europe. No differences were found.

Abdomen↗

Early diagnostic markers for neonatal sepsis: comparing C-reactive protein, interleukin-6, soluble tumour necrosis factor receptors and soluble adhesion molecules.

We compared six inflammatory mediators (C-reactive protein (CRP), interleukin-6 (IL-6), soluble tumour necrosis factor receptors (p55 and p75) and soluble adhesion molecules (ICAM-1, E-selectin)) as early diagnostic tests for neonatal sepsis, and studied the possible benefit of combining parameters. Blood samples were obtained from 166 consecutively admitted neonates, who were suspected to suffer from infection within the first week of life. Neonates were retrospectively classified as infected (sepsis, clinical sepsis or pneumonia), possibly infected, or non-infected. Twenty-four infected neonates had higher serum levels of all six mediators (all P < 0.05), and 18 possibly infected neonates had higher levels of CRP, IL-6, ICAM-1 and E-selectin (all P < 0.05), than neonates without infection (n = 124). Receiver operator characteristic plots showed that CRP was the single best diagnostic test. Multiple logistic regression modelling, including various combinations of two to six mediators, consistently showed that IL-6, in addition to CRP, predicted sepsis. With infected and possibly infected neonates as the reference standard, a combined test of CRP > or = 10 mg/l and/or IL-6 > or = 20 pg/ml had a sensitivity of 85%, specificity of 62%, and negative likelihood ratio of 0.24. Using infected neonates as reference standard alone, and including possibly infected as controls, sensitivity increased to 96%, whereas specificity decreased to 58%; a negative test result (CRP < 10 mg/l and IL-6 < 20 pg/ml) ruled out sepsis with high certainty (likelihood ratio = 0.07). CRP performed best as a diagnostic test for neonatal sepsis. Diagnostic accuracy was further improved by combining CRP and IL-6, whereas the other parameters (p55, p75, ICAM-1 and E-selectin) added no further diagnostic information.

Biomarkers↗

The clinical diagnosis of acute purulent sinusitis in general practice--a review.

Acute sinusitis is a common illness in primary care. Studies have demonstrated the difficulty of making the differential diagnosis of acute purulent sinusitis based on clinical evaluations alone. This leads to a significant overuse of antibiotics, which in turn may contribute to increased bacterial resistance. In most cases, GPs have to base their differential diagnosis of sinusitis on clinical signs and symptoms and examination of the patient. The aim of this review is to assess which clinical signs and symptoms can predict an acute purulent sinusitis, compared with accepted reference standards. A review of the literature was performed by looking at articles related to the diagnoses of acute sinusitis in general practice. The following search criteria were used: unselected general practice population; objective reference standard; and logistic regression to evaluate symptoms and signs independently associated with the diagnosis. Four studies were identified for further analysis. The following symptoms and signs were associated with acute purulent sinusitis: purulent secretion as a symptom experienced by the patient or as a sign demonstrated in the nasal cavity by the doctor; pain in the teeth; pain at bending forward, and two phases in the illness history. An elevated erythrocyte sedimentation rate and increased C-reactive protein also contributed to the diagnosis. By use of the specified signs and symptoms the GP can increase the probability of correctly diagnosing an acute purulent sinusitis and reserve antibiotic prescription for these patients.

Acute Disease↗

[Clinical laboratory data and reference intervals standardized in Fukuoka].

In Fukuoka whose population is approximately five million inhabitants, surveys on the accuracy of laboratory data have been performed by the Fukuoka Prefecture Medical Association for the last 30 years. We have been attempting to evaluate the data for routine use since 1988, and it has become possible to share laboratory data between all institutions in Fukuoka prefectures. As a result, reference intervals for 23 clinical chemistry analytes were established in 1995, to which were added in 1996 five serum protein constituents that have been utilized for clinical examinations. Methods for documentations and monitorings the data obtained in the prefecture were also established, standardization of the above analytes extended to 97% of the institutions in the prefecture. Results for 14 of the 23 clinical chemistry analytes have become highly reliable and clinically useful as differences between institutions in terms of results have narrowed. Standardization of other analytes is now in progress.

Aged↗

Quality of reporting of test accuracy studies in reproductive medicine: impact of the Standards for Reporting of Diagnostic Accuracy (STARD) initiative.

OBJECTIVE: To evaluate the extent to which test accuracy studies published in two leading reproductive medicine journals in the years 1999 and 2004 adhered to the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters, and to explore whether the introduction of the STARD statement has led to an improved quality of reporting. DESIGN: Structured literature search. Articles that reported on the diagnostic performance of a test in comparison with a reference standard were eligible for inclusion. For each article we scored how well the 25 items of the STARD checklist were reported. These items deal with the study question, study participants, study design, test methods, reference standard, statistical methods, reporting of results, and conclusions. We calculated the total number of reported STARD items per article, summary scores for each STARD item, and the average number of reported STARD items per publication year. SETTING: Not applicable. PATIENT(S): Not applicable. INTERVENTION(S): Not applicable. MAIN OUTCOME MEASURE(S): Quality of reporting. RESULT(S): We found 24 studies reporting on test accuracy in reproductive medicine in 1999 and 27 studies in 2004. The mean number of reported STARD items for articles published in 1999 was 12.1 +/- 3.3 (range 6.5-20) and 12.4 +/- 3.2 (range 7-17.5) in 2004, after publication of the STARD statement. Overall, less than half of the studies reported adequately on 50% or more of the STARD items. The reporting of individual items showed a wide variation. There was no significant improvement in mean number of reported items for the articles published after the introduction of the STARD statement. CONCLUSION(S): Authors of test accuracy studies in the two leading fertility journals poorly report the design, conduct, methodology, and statistical analysis of their study. Strict adherence to the STARD guidelines should be encouraged.

Clinical Trials as Topic↗

Comparison between a new 13C-urea breath test, using a film-coated tablet, and the conventional 13C-urea breath test for the detection of Helicobacter pylori infection.

BACKGROUND: In Japan, urea breath-testing includes mouth rinsing with water immediately after the ingestion of (13)C-urea solution, to prevent false-positive results that are caused by oral bacteria with urease activity. Our objective was to evaluate the diagnostic performance of a urea breath test using a film-coated (13)C-urea tablet and omitting mouth rinsing. METHODS: The study was a multicenter trial comparing the solution- and tablet-based urea breath tests (UBTs). Helicobacter pylori status was determined by histology, culture, and rapid urease testing. RESULTS: Of the 255 subjects who completed the study, evaluation of the tablet-based UBT was possible in 254, and comparison of the tablet-based UBT and the solution-based UBT was possible in 250 patients. When the assessment achieved by a combination of biopsy-based methods was used as a reference standard, the sensitivity, specificity, and accuracy of the tablet-based method were determined to be 97.7%, 98.4%, and 98.0%, respectively. When the results of the solution-based UBT were used as a reference standard, the sensitivity, specificity, and accuracy of the tablet-based UBT were determined to be 96.9%, 97.6%, and 97.2%, respectively. CONCLUSIONS: The (13)C-urea tablet-based method proved to be a simple and accurate test for the diagnosis of H. Pylori infection. Mouth rinsing was not required.

Adult↗

Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis: determination of volatile and semi-volatile organophosphate esters.

A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with methanol, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust, SRM 1649a).

Air Pollutants↗

Procedural skills in spinal manipulation: do prerequisites matter?

BACKGROUND CONTEXT: Spinal manipulation has undergone a resurgence of interest. Developing evidence suggests a relationship between safety, skill and clinical outcome. Training programs are variable and range from extensive formalized curricula to weekend seminars and individual demonstrations. Systematic study of a relationship between prerequisites and skill development has not been conducted. PURPOSE: This project evaluated programmatic differences in prerequisites of students during their training for spinal manipulation with respect to quantitative biomechanical evidence of procedural control and skill of performance of a novel task. STUDY DESIGN/SETTING: The research used an experimental design comparing two cohorts involved in separate training programs at different institutions that had distinguishing characteristics in methods of prerequisites to manipulation training. METHODS: A common manipulation procedure (L4 mamillary push [L4MP]) was chosen as a standard test maneuver. Performance of the procedure on initial effort by two cohorts of students (n=38 vs n=39) entering into training for lumbar spine procedures was measured. Comparisons were made based on quantitative biomechanical parameters to assess control and skill. Results were compared with a cohort of experts as a reference standard. RESULTS: Significant differences were observed between the performance measures of the two cohorts. The more skilled performance group was more similar to the expert reference standard than was the lesser skilled group. CONCLUSIONS: The duration, extent and content of prerequisites for learning the dynamic and complex manual skills for spinal manipulation can significantly influence the level of skill attainment even early in the course of training.

Adult↗

Glucagon and insulin from lean rats and genetically obese fatty rats: studies by radioimmunoassay, radioreceptorassay and bioassay.

Insulin, proinsulin and glucagon extracted from lean rat pancreases were studied in radioimmunoassay, radioreceptorassay and bioassay systems. Extracted insulin behaved identically to a rat insulin used as a reference standard in radioimmunoassay. On the basis of its immunoreactivity, extracted insulin was slightly less potent (about 70%) than the rat standard insulin in competing with the binding of 125I-insulin to rat liver membranes (radioreceptorassay) and in stimulating glucose oxidation by rat fat cells (bioassay). Extracted glucagon and a pork glucagon used as a reference standard were indistinguishable in two radioimmunoassay systems for glucagon, in competing with the binding of 125I-glucagon to rat liver membranes (radioreceptorassay) and in stimulating adenylate cyclase in rat liver membranes (bioassay). Genetically obese rats (Zucker, "fatty") were compared to their lean littermates with respect to insulin, proinsulin and glucagon extracted from their pancreases. Proinsulin represented the same proportion of total immunoreactive insulin in both types of rats. In the radioimmunoassays, the radioreceptorassays and the bioassays, insulin, proinsulin and glucagon from obese rats were indistinguishable from insulin, proinsulin and glucagon from lean rats. It is concluded that the pancreatic hormones of obese ("fatty") rats possess the same immunoreactivity and biological potency as those of nonobese rats. This excludes the possibility that some alteration in the biological properties of pancreas insulin and/or glucagon of fatty rats could explain the metabolic abnormalities observed in this type of obesity.

Adenylyl Cyclases↗

STaT: a three-question screen for intimate partner violence.

OBJECTIVE: To develop a simple, sensitive screening tool for lifetime intimate partner violence (IPV) in women. METHODS: In the emergency department (ED) of an urban teaching hospital, 75 English-speaking women between 18 and 64 years old were tested. The sensitivity and specificity of 43 dichotomous response-option, IPV screening questions were compared. The reference standard was lifetime IPV, determined by a semistructured interview, using preset criteria of specific violence acts or emotional control or both by an intimate partner. Questions with high sensitivity (>70%) were tested together against the reference standard. Answering yes to any question scored 1 point. Content area and the area under receiver-operator curve (AUROC) of the screening questions determined the final tool. RESULTS: Sixty-three percent of women reported lifetime IPV. Eight of the 43 screening questions had a sensitivity of >70%. After testing possible combinations, the final three-question screen, STaT had the highest AUROC. The STaT questions are: "Have you ever been in a relationship where your partner has pushed or Slapped you?" "Have you ever been in a relationship where your partner Threatened you with violence?" and "Have you ever been in a relationship where your partner has thrown, broken or punched Things?" The sensitivity (95% confidence intervals [95% CI]) of STaT for lifetime IPV is 96% (90%, 100%), 89% (81%, 98%), and 64% (50%, 78%) for a score of >/=1, >/=2, and 3, respectively. The corresponding specificity is 75% (59%-91%), 100%, and 100%. CONCLUSIONS: Three simple questions when used together can effectively identify lifetime IPV and will aid clinicians' efforts to identify abuse in women.

Adult↗