Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radionuclide Generators”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Quantitative assessment of blood flow in pediatric recipients of renal transplants.

We applied a renal blood flow (RBF) quantification technique to pediatric data, which depends minimally on bolus shape, uses a conventional radiopharmaceutical 99mTc-DTPA, and generates a value for RBF as a percentage of cardiac output (RBF/CO). Mean RBF was 16.9% (+/- 4.8) for normal transplants, 13.1% (+/- 2.9) for transplants undergoing mild-to-moderate chronic rejection, 7.9% (+/- 1.3) for those with mild acute rejection and 3.3% (+/- 1.4) for those with moderate-to-severe acute rejection. Very low blood flow values within 24 hr following transplantation may have prognostic significance. Patients who required transplant-nephrectomy had significantly lower RBF/CO values than children who retained their allograft.

Adolescent↗

Effect of chemical and radiochemical impurities from eluants on 99mTc-labeling efficiency.

Occasionally, radiopharmaceuticals prepared from the eluates of 99Mo-99mTc generators that have not been eluted for several days contain large amounts of free pertechnetate, as tested by radiochromatography and biologically by administration to patients. We fing the most probable causes of poor 99mTc-labeling in these cases to be: a) the presence of a large concentration of 99TcO4-in eluants; b) insufficient stannous ions available for the complete reduction of Tc due to spontaneous oxidation of Sn in the vial and also due to oxidation of stannous ions by the presence of larger than expected concentrations of H2O2 and HO2 radicals in the eluant.

Brain↗

The stability in liver homogenates of indium-111 and yttrium-90 attached to antibody via two popular chelators.

To investigate the influence of chelator on the stability in liver homogenates of 111In and 90Y-labeled antibodies, the C110 antibody was conjugated with the cyclic anhydride of DTPA (cDTPA) and with isocyanatobenzyl-DTPA (SCN-Bz-DTPA) and labeled with both radionuclides. After incubation in fresh liver homogenates at 37 degrees C for 1-2 days, the soluble fraction was analyzed by filtration, HPLC and TLC to determine the nature and extent of transchelation of the label and catabolism of the antibody. The loss of activity from antibody, as shown by passage through a low molecular weight (10 kDa cut-off) filter, was 3-5 times more pronounced for 90Y (51 and 68% at 1 and 2 days) than 111In (11 and 29%, respectively). No significant difference was observed between chelators. Furthermore, analysis of these low molecular weight species showed that even at 1 day, 90Y in contrast to 111In was present as one or more weak complexes and therefore no longer chelated to either DTPA or Bz-DTPA. Little evidence was observed for instability in liver of the thiourea bond whereby SCN-Bz-DTPA is attached to the antibody. By contrast the identification of 111In-DTPA in the homogenates demonstrates the instability of the amide bond generated by cDTPA conjugation. In conclusion, as expected, 90Y was shown to form less stable chelates than 111In, however, in this investigation the greater denticity of Bz-DTPA over DTPA did not improve stability with either radiolabel.

Animals↗

New calculations of the atmospheric cosmic radiation field--results for neutron spectra.

The propagation of primary cosmic rays through the Earth's atmosphere and the energy spectra of the resulting secondary particles have been calculated using the Monte Carlo transport code FLUKA with several novel auxiliary methods. Solar-modulated primary cosmic ray spectra were determined through an analysis of simultaneous proton and helium measurements made on spacecraft or high-altitude balloon flights. Primary protons and helium ions are generated within the rigidity range of 0.5 GV-20 TV, uniform in cos2theta. For a given location, primaries above the effective angle-dependent geomagnetic cut-off rigidity, and re-entrant albedo protons, are transported through the atmosphere. Helium ions are initially transported using a separate transport code called HEAVY to simulate fragmentation. HEAVY interfaces with FLUKA to provide interaction starting points for each nucleon originating from a helium nucleus. Calculated cosmic ray neutron spectra and consequent dosimetric quantities for locations with a wide range of altitude (atmospheric depth) and geomagnetic cut-off are presented and compared with measurements made on a high-altitude aeroplane. Helium ion propagation using HEAVY and inclusion of re-entrant albedo protons with the incident primary spectra significantly improved the agreement of the calculated cosmic ray neutron spectra with measured spectra. These cosmic ray propagation calculations provide the basis for a new atmospheric ionising radiation (AIR) model for air-crew dosimetry, calculation of effects on microelectronics, production of cosmogenic radionuclides and other uses.

Algorithms↗

A potential copper radiopharmaceutical for imaging the heart and brain: copper-labeled pyruvaldehyde bis(N4-methylthiosemicarbazone).

An investigation of the biodistribution of lipophilic copper-64 (half-life = 12.7 h) compounds has been initiated in order to screen potential tracers that could be used to measure regional cerebral and/or myocardial blood flow when labeled with generator-produced 62Cu. The 64Cu complex of pyruvaldehyde bis(N4-methylthiosemicarbazone), [64Cu]Cu-PTSM, was prepared and found to be lipophlic (octanol/saline partition coefficient, log p = 1.97 +/- 0.03). Biodistribution studies following i.v. injection of [64Cu]Cu-PTSM into rats show tracer uptake by the brain and heart. At 1, 5, and 15 min post-injection 3.3, 3.0 and 2.7% of the injected dose was found in the brain. Corresponding brain to blood ratios (per gram) were 3.2, 3.6 and 4.0 respectively. Heart to blood ratios of 7.6, 7.6 and 7.3 were observed at these same time points.

Animals↗

Assessing lung deposition of inhaled medications. Consensus statement from a workshop of the British Association for Lung Research, held at the Institute of Biology, London, U.K. on 17 April 1998.

In vitro measurements of aerosol fine particle fraction (FPF) using particle-sizing apparatus (e.g. the twin impinger, multi-stage liquid impingers, cascade impactors) have a key role to play in the development of new pharmaceutical products and in quality control. However, use of in vitro methodology to attempt to predict lung deposition in vivo is of limited value due, in part, to the inability of current apparatus to mimic upper and lower airway anatomy satisfactorily. Estimates of FPF based on cut-off points ranging from 5-7 microns generally overestimate lung deposition as measured in vivo by gamma scintigraphy. We recommend that: 1. multistage apparatus (minimum five stages) be used to characterize particle size distribution adequately, over the range 0.5-5.0 microns; 2. where possible, measurements should be made at a range of rates and profiles of flow reflecting those likely to be generated using the inhalation device in clinical practice (including use by young and elderly patients with varying degrees of airflow obstruction); 3. encouragement should be given to the further development, standardization, and validation of apparatus with a 'throat' which more closely resembles the human oropharynx and larynx. Pharmacokinetic methods can give a good estimate of total, but not regional, lung deposition, with drugs which are either not absorbed via the gastrointestinal tract, or whose absorption can be blocked by co-administration of charcoal, thus avoiding confounding by absorption of drug substance deposited in the oropharynx and subsequently swallowed. Techniques which rely on evaluation of a timed fractional output of drug substance in the urine are susceptible to the inherent variability of rate of absorption across the respiratory epithelium. We recommend that consideration should be given to the further refinement and validation of PK methods which would more clearly identify the fractional dose deposited in the lung. Lung-imaging methodology, e.g. gamma scintigraphy, employing formulations radiolabelled with gamma-ray-emitting radionuclides such as 99mTc, can measure total lung deposition and oropharyngeal deposition, provided that the radiolabelling process is appropriately validated and suitable corrections are made for attenuation of gamma rays by body tissues. An estimate of regional lung deposition can be made by drawing 'regions of interest' on the scintigraphic image; the precision of this measure is limited by the two-dimensional (2-D) nature of most images which mean that there is an overlay of structures of interest (alveoli, small and large airways), which is most marked centrally. Three-dimensional (3-D) imaging techniques (e.g. single photon emission computed tomography, SPECT, and positron emission tomography, PET) have the potential to give more detailed data on regional lung deposition, but are currently more expensive, employ higher radiation doses, and are less well validated than 2-D (planar) imaging. We consider that, of the available imaging modalities, planar gamma scintigraphy represents current best practice for the assessment of lung deposition from inhaler devices where regional differences may be important. The methodology should be optimized by the adoption of generally accepted standards for radiolabelling, imaging, attenuation correction, and interpretation. It is important that deposition in all sites (device, oropharynx, lungs, stomach) should be quantified. Consideration should be given to refining the concept of regions of interest to coincide more closely with anatomical lung structures. Statistical methods to compare the size distributions of drug and radiolabel in validation experiments should be developed. In the longer term it is envisaged that three-dimensional imaging may play a more important part in evaluating lung deposition; an optimal three-dimensional anatomical model of lung zones of interest needs to be developed.

Administration, Inhalation↗

The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema.

Condensed image processing (CIP), a computerized technique of scintiscans that generates a vertical distribution of activity as a function of time in a single image, was applied to isotopic lymphoscintigrams of four patients with leg lymphedema. By "condensing" information gained from multiple images into a single image, CIP better evaluates ascending progression of radiolabeled colloid in peripheral lymph and better localizes stagnant areas. In "high lymph flow failure," CIP also depicts radioactive "bursts" suggestive of increased lymphatic truncal contractility. This data processing method improves interpretation of dynamic scintiscan recordings and seems ideally suited for evaluation of peripheral lymph kinetics.

Adolescent↗

The role of 99mTc-bound phosphates and grey scale echography in the differentiation of pelvic tumors.

99mTc-pyrophosphate and 99mTc-diphosphonate have successfully been employed in the diagnosis of neoplastic pelvic disease in women. In our ongoing study, 48 women with pelvic masses, underwent dynamic pelvic scintigraphy, correlative ultrasonography and exploratory laparotomy. Dynamic scintigraphy and region of interest time/activity curves generated from computerized data acquisition have proven effective in the differential diagnosis of uterine leiomyomas from ovarian cysts. In a group of 24 women whose scintigraphic data were consistent with our criteria for uterine leiomyoma, 21 were confirmed histologically. Of 30 women, 29 were accurately diagnosed on scintigraphy as having an ovarian cyst and two patients with coexisting ovarian cysts and uterine fibroids were both correctly diagnosed prior to surgery. Detected lesions ranged from 6--22 cm in diameter. Our findings support the use of dynamic pelvic scintigraphy for differentiating uterine leiomyomas from ovarian cysts.

Adolescent↗

Angular deformity of the lower extremity: evaluation with quantitative bone scintigraphy. Work in progress.

A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 34 children (23 healthy, 11 with angular deformity). Normal ratios were 0.74-0.98 for femurs and 0.98-1.20 for tibias. An above-normal ratio correlated with the presence of valgus deformity and a below-normal ratio with varus deformity. This technique may provide a means of monitoring growth after trauma or infection.

Adolescent↗

Interpretation of multigated Fourier functional images.

First-harmonic Fourier analysis is currently used to aid in the interpretation of multigated cardiac studies. Its intrinsic inaccuracies are not generally appreciated. This study investigates the characteristics and magnitudes of the errors of this technique. The study analyzes computer-generated phantoms that isolate the various motions of the ventricles (contraction, translation, and rotation) with the first-harmonic approach. The first-harmonic output is compared with a more accurate fitting scheme using multiple terms of the Fourier expansion. Significant artifacts of the inaccuracy of the first harmonic appear in the phantom studies and are observed in patient examples. We conclude that caution is needed in interpreting first-harmonic phase and amplitude images, and particularly in associating them with parameters like the onset of contraction and the stroke volume.

Computers↗

Antifibrinolytic activity of apolipoprotein(a) in vivo: human apolipoprotein(a) transgenic mice are resistant to tissue plasminogen activator-mediated thrombolysis.

The extensive homology between apolipoprotein(a) and plasminogen has led to the hypothesis that the increased risk for atherosclerosis, cardiac disease and stroke associated with elevated levels of apolipoprotein(a) may reflect modulation of fibrinolysis. We have investigated the role of apolipoprotein(a) on clot lysis in transgenic mice expressing the human apolipoprotein(a) gene. These mice develop fatty streak lesions resembling early lesions of human atherosclerosis. Pulmonary emboli were generated in mice by injection, through the right jugular vein, of a human platelet-rich plasma clot radiolabelled with technetium-99m-labelled antifibrin antibodies. Tissue plasminogen activator was introduced continuously via the right jugular vein. Clot lysis, determined by ex vivo imaging, was depressed in mice carrying the apolipoprotein(a) transgene relative to their sex-matched normal littermates. These results directly demonstrate an in vivo effect of apolipoprotein(a) on fibrinolysis, an effect that may contribute to the pathology associated with elevated levels of this protein.

Animals↗

Neural network analysis of the volumetric capnogram to detect pulmonary embolism.

BACKGROUND: Pulmonary embolism (PE) produces ventilation/perfusion mismatch that may be manifested in various variables of the volume-based capnogram (VBC). We hypothesized that a neural network (NN) system could detect changes in VBC variables that reflect the presence of a PE. METHODS: A commercial VBC system was used to record multiple respiratory variables from consecutive expiratory breaths. Data from 12 subjects (n = 6 PE+ and n = 6 PE-) were used as input to a fully connected back-propagating NN for model development. The derived model was tested in a prospective, observational study at an urban teaching hospital. Volumetric capnograms were then collected on 53 test subjects: 30 subjects with PE confirmed by pulmonary angiography or diagnostic scintillation lung scan, and 23 subjects without PE based on pulmonary angiography. The derived NN model was applied to VBC data from the test population. RESULTS: Seventeen VBC variables were used by the derived NN model to generate a numeric probability of PE. When the derived NN model was applied to VBC data from the 53 test subjects, PE was detected with a sensitivity of 100% (95% CI = 89% to 100%) and a specificity of 48% (95% CI = 27% to 69%). The likelihood ratio positive [LR(+)] for the VBC-NN test was 1.82 and the LR (-) was 0.1. CONCLUSION: This study demonstrates the feasibility of developing a rapid, noninvasive breath test for diagnosing PE using volumetric capnography and NN analysis.

Angiography↗

Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

The use of on-resonance 121 binomial composite pulses in two- or three-dimensional magnetization-prepared gradient-recalled echo magnetic resonance imaging experiments generates rotary echoes, leading to an increase in contrast range that is, in part, determined by the ratio of T2 to T1. In comparison with other fast gradient-recalled echo imaging techniques designed for enhanced T2 contrast, this method is more robust with respect to radiofrequency field inhomogeneity and less sensitive with respect to motion artifacts. Three-dimensional parametric images may be calculated using least-squares fitting based on a simple model for steady-state longitudinal magnetization during the imaging sequences.

Brain↗

Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography.

To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP (12.8+/-1.4 degrees vs. 14.6+/-2.2 degrees, p < 0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9+/-23.7% whereas that in VAP patients was -9.1+/-17.3% (p < 0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients.

Adult↗

Labelling of leukocytes with 99mTc-HMPAO for scintigraphy of inflammatory lesions and abscesses.

A simplified and efficient procedure for 99mTc-HMPAO-labelling of leukocytes is described. For this purpose, the pH and concentration of the 99mTc-HMPAO preparation was modified. Leukocytes were isolated from a 20 mL mixture of patient blood, 5 mL ACD and 0.8 mL methylcellulose after 1 h sedimentation of erythrocytes and centrifugation (at 400 g) of the obtained plasma layer. Simultaneously, 99mTc-HMPAO was prepared (one single-dose kit for two patients) by adding 2.2 mL 99mTc-generator eluate and, after 10 min, 0.3 mL of phosphate buffer to lower the pH to 7. The isolated WBCs were then labelled by the addition of 1-1.2 mL of 99mTc-HMPAO solution and incubated for 20 min. The unbound tracer was then discarded, the labelled WBC washed and finally resuspended in autologous cell-free plasma. Leukocytes labelled by this procedure were used for scintigraphic localization of inflammatory lesions and abscesses in the gastro-intestinal tract. The labelling efficiency was 60 +/- 9%, with a separation yield of 55 +/- 11%.

Abscess↗

Scintigraphic methods to detect beta2-microglobulin associated amyloidosis (Abeta2-microglobulin amyloidosis).

beta2-Microglobulin-derived amyloidosis (Abeta2m) represents a major cause or morbidity in patients with end-stage renal disease. Symptoms of Abeta2m amyloid are mainly related to (peri-) articular amyloid deposition. Conventional non-invasive diagnostic techniques, i.e. clinical evaluation, joint ultrasonography or X-ray, computed tomography or magnetic resonance imaging findings, as well as conventional bone scans, suffer from relative non-specificity and/or low sensitivity. Two recent methods, namely scintigraphy with radiolabelled serum amyloid P component (SAP) or with the radiolabelled Abeta2m-precursor protein, beta2-microglobulin (beta2m), yield more specific information. Using (123)I-labelled SAP, Abeta2m deposits have been visualized in several long-term haemodialysis (HD) patients. However, this scan did not show tracer accumulation in other frequently involved sites, such as hips or shoulders, but did frequently label the spleen, which is usually spared from Abeta2m deposits. Scanning with (131)I-labelled beta2m, in contrast, yielded tracer accumulations corresponding to the typical distribution pattern of Abeta2m. Specificity of this method was shown by several methods, and the sensitivity was found to markedly exceed that of combined clinical and radiological investigations. Recently, both the radiation exposure and the optical resolution of this latter scan have been further refined by substituting (131)I with (111)In. In a final step we generated recombinant human beta2m (rhbeta2m). (111)In-rhbeta2m again failed to show significant tracer accumulation over joint regions in patients on short-term HD without evidence of Abeta2m amyloidosis. In contrast, local tracer accumulations similar to those observed with natural, (111)In-labelled beta2m could be demonstrated in long-term HD patients with evidence of Abeta2m amyloidosis. In conclusion, scintigraphy for Abeta2m with (111)In-labelled rhbeta2m provides a homogenous and safe recombinant protein source, and allows for the sensitive and specific non-invasive detection of Abeta2m-amyloid deposits in dialysis patients.

Amyloidosis↗

Effects of extracorporeal shock wave lithotripsy on tiered therapy implantable cardioverter defibrillators.

The effects of extracorporeal shock wave lithotripsy (ESWL) were tested on four advanced generation implantable cardioverter-defibrillators (ICDs) in vitro and in vivo in two patients. During in vitro testing, advancement of nonsustained episode counters occurred in one device, and a set screw and power source cell loosened in another, which was connected to an external power source. No arrhythmias occurred during in vivo procedures, but programmed parameters were reset and elective replacement indicated after one procedure. ESWL can be performed safely in selected patients with ICDs, but testing should be performed afterwards to confirm satisfactory function and component continuity.

Defibrillators, Implantable↗

Effect of nisoldipine on exercise performance in heart failure following myocardial infarction.

The effects of the second generation calcium channel blocking drug nisoldipine on subjective and objective measurements of exercise performance were studied in 19 patients with moderate to severe heart failure (9 New York Heart Association functional class 2, 9 class 3 and 1 class 4) due to fixed ventricular dysfunction following myocardial infarction. Nisoldipine (10 mg 3 times daily) or placebo were administered for 8 weeks in a double-blind parallel study, assessing exercise performance by symptom-limited treadmill exercise testing using a modified Naughton protocol. Nisoldipine was well-tolerated and produced a small increase in peak estimated workload performed (6.2 +/- 2.9 to 8.2 +/- 3.0 METs, p = 0.06). The rate of perceived exertion (Borg scale) increased from 17.5 +/- 2.2 to 18.8 +/- 1.2 (p less than 0.02). The higher workload was performed at a lower peak systolic blood pressure (p = 0.03), higher peak heart rate (p = 0.06) and identical double product (NS). There was no change in resting and peak heart rate and blood pressure or in exercise performance in patients receiving placebo. Resting left ventricular ejection fraction, measured by radionuclide ventriculography, was unchanged after 8 weeks both in the placebo (21 +/- 9 to 20 +/- 9%) and nisoldipine (34 +/- 17 to 36 +/- 19%) groups.

Aged↗