Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications. I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry.

A new technique for sample preparation on-line with LC and GC-MS assays was developed. Microextraction in a packed syringe (MEPS) is a new miniaturised, solid-phase extraction technique that can be connected on-line to GC or LC without any modifications. In MEPS approximately 1mg of the solid packing material is inserted into a syringe (100-250 microl) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising. It is very easy to use, fully automated, of low cost and rapid in comparison with previously used methods. This paper presents the development and validation of a method for microextraction in packed syringe MEPS on-line with GC-MS. Local anaesthetics in plasma samples were used as model substances. The method was validated and the standard curves were evaluated by the means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 5-2000 nM. The applied polymer could be used more than 100 times before the syringe was discarded. The extraction recovery was between 60 and 90%. The results showed close correlation coefficients (R>0.99) for all analytes in the calibration range studied. The accuracy of MEPS-GC-MS was between 99 and 115% and the inter-day precision (n=3 days), expressed as the relative standard deviation (R.S.D.%), was 3-10%.

Anesthetics, Local↗

Validated semiquantitative/quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection.

A comprehensively validated procedure is presented for simultaneous semiquantitative/quantitative screening of 51 drugs of abuse or drugs potentially hazardous for traffic safety in serum, plasma or whole blood. Benzodiazepines (12), cannabinoids (3), opioids (8), cocaine, antidepressants (13), antipsychotics (5) and antiepileptics (2) as well as zolpidem, zaleplon, zopiclone, meprobamate, carisoprodol, tizanidine and orphenadrine and internal standard flurazepam, were isolated by high-yield liquid-liquid extraction (LLE). The dried extracts were derivatized by two-step silylation and analyzed by the combination of two different gas chromatographic (GC) separations with both electron capture detection (ECD) and mass spectrometry (MS) operating in a selected ion-monitoring (SIM) mode. Quantitative or semiquantitative results were obtained for each substance based on four-point calibration. In the validation tests, accuracy, reproducibility, linearity, limit of detection (LOD) and limit of quantitation (LOQ), selectivity, as well as extraction efficiency and stability of standard stock solutions were tested, and derivatization was optimized in detail. Intra- and inter-day precisions were within 2.5-21.8 and 6.0-22.5%, and square of correlation coefficients of linearity ranged from 0.9896 to 0.9999. The limit of quantitation (LOQ) varied from 2 to 2000 ng/ml due to a variety of the relevant concentrations of the analyzed substances in blood. The method is feasible for highly sensitive, reliable and possibly routinely performed clinical and forensic toxicological analyses.

Gas Chromatography-Mass Spectrometry↗

Improved methods for the extraction and analysis of isoflavones from soy-containing foods and nutritional supplements by reversed-phase high-performance liquid chromatography and liquid chromatography-mass spectrometry.

An improved method for extraction and analysis of isoflavones from soy protein, soy foods and nutritional supplements is presented. The method uses acetonitrile extraction without acidification, with apigenin as internal standard. Samples extracted in acetonitrile-water are diluted to 50% acetonitrile and directly injected for gradient HPLC separation on a C18 reversed-phase column. This method saves significant time during sample preparation and improves accuracy and precision. Conventional and rapid HPLC analysis methods compatible with the extraction scheme were developed. During development of the methods, unexpected minor forms of malonyl and acetyl isoflavones were discovered in extracts of soy proteins and in pure isoflavone standard preparations. By LC-triple MS, these peaks have identical composition to the respective 6''-O-malonyl- and 6''-O-acetyl-isoflavones from which they form. These minor forms are believed to be malonyl and acetyl isoflavones where the site of attachment is a hydroxyl other than the 6'-OH of the glucose. These compounds can represent significant minor isoflavone components of foods, which contain high concentrations of malonyl or acetyl isoflavones.

Chromatography, High Pressure Liquid↗

Some applications of near-ultraviolet laser-induced fluorescence detection in nanomolar- and subnanomolar-range high-performance liquid chromatography or micro-high-performance liquid chromatography.

In this work we present some applications of near-UV laser-induced fluorescence (LIF) with micro-HPLC (microHPLC) and HPLC. To test the sensitivity of the detection, we used pyrene and aflatoxins, because both of these molecules exhibit native fluorescence. Then we studied catecholamines derivatized with 1,2-diphenylethylenediamine. The results show that we were able to reach better sensitivity levels than previously described in LIF studies. For catecholamines, a 50-fold increase in sensitivity compared to conventional fluorescence was obtained. These results indicate that LIF detection associated with HPLC or microHPLC can be used to detect very low concentrations of substances that can be excited in the near-UV range after labeling at nanomolar concentrations.

Aflatoxins↗

Use of silylating agents for the identification of hydroxylated steroids by gas chromatography and gas chromatography-mass spectrometry. Discrimination between phenolic and alcoholic hydroxyl groups.

A phenolic trimethylsilyl (TMS) group was selectively exchanged for a dimethylalkylsilyl (DMAS) group on a gas chromatographic column by use of sandwich injection technique with DMAS-imidazole, and a TMS ether derivative of a phenolic steroid was converted into a DMAS ether or a mixed TMS and DMAS ether derivative with over 95% recovery. The selective exchange reaction seemed to be caused by the difference in lability between the ethereal TMS linkages to phenolic and alcoholic hydroxyl groups. This selectivity was found to be useful for discriminating gas chromatographically between the phenolic and alcoholic hydroxyl groups in steroids.

Alcohols↗

Concentration of headspace, airborne and aqueous volatiles on Chromosorb 105 for examination by gas chromatography and gas chromatography-mass spectrometry.

Techniques are described for the collection of volatile material from headspace vapours and the atmosphere and for the direct extraction of volatiles from aqueous solution by traps containing the porous polymer Chromosorb 105. The traps are inserted through a valve into a gas chromatograph which facilitates the desorption and transfer of the volatiles to high-resolution capillary columns. Selected applications of the technique are described.

Air Pollutants↗

Studies on the analysis of food additives by high-performance liquid chromatography. V. Simultaneous determination of preservatives and saccharin in foods by ion-pair chromatography.

A high-performance liquid chromatographic method for the simultaneous determination of sorbic acid, benzoic acid, p-hydroxybenzoic acid and its methyl, ethyl, isopropyl, n-propyl, isobutyl, n-butyl esters and saccharin in foodstuffs is described. For good separations of these compounds, acetonitrile-water-0.2 M phosphate buffer pH 3.6 (7:12:1) containing 2 mM cetyltrimethylammonium bromide as an ion-pair reagent and a Nucleosil 5C18 column are required. A steam distillation method and a Sep-Pak C18 cartridge method for the sample preparation are compared. The recoveries from a coffee drink were generally better than 93.8% and the relative standard deviations were 0.85-2.15% for the Sep-Pak C18 cartridge method.

Beverages↗

High-performance liquid chromatography of amino acids, peptides and proteins. LXXXVII. Comparison of retention and bandwidth properties of proteins eluted by gradient and isocratic anion-exchange chromatography.

The high-performance ion-exchange gradient-elution behaviour of a range of globular proteins has been investigated, using a strong anion exchanger as the stationary phase and sodium chloride as the displacer salt. Deviations were observed between the Zc values obtained from isocratic experiments and from gradient experiments with varied gradient time and varied flow-rate. These results indicate that theoretical treatments which relate gradient and isocratic elution processes do not adequately describe the retention behaviour of protein solutes separated by ion-exchange methods. Furthermore, the experimentally observed bandwidths deviated significantly from values predicted on the basis of plate theory for low-molecular-weight molecules. The significance of these results is discussed in terms of the influence of experimental parameters on the ability of particular electrostatically interactive areas on the surface of protein solutes to control the thermodynamic and kinetic properties of these polyelectrolyte molecules during ion-exchange chromatographic processes.

Amino Acids↗

Agarderivatives for chromatography, electrophoresis and gel-bound enzymes. IV. Benzylated dibromopropanol cross-linked sepharose as an amphophilic gel for hydrophobic salting-out chromatography of enzymes with special emphasis on denaturing risks.

The preparation of benzylated covalently cross-linked Sepharose 2B is described. Such gel was analyzed for its degree of substitution, and gels with three different degrees of substitution were used in chromatographic experiments with dextranase, alpha-amylase, lactate dehydrogenase, alpha-chymotrypsin and trypsin. Yields and chromatographic patterns for different eluting systems were determined. It was found that gradients combining an increase in ethylene glycol concentration with a decrease in salt concentration gave better results than did pure salt gradients. No denaturation was observed for dextranase or alpha-amylase, but the other enzymes tested were partly denatured. The most severe denaturation was observed for lactate dehydrogenase desorbed from the highest substituted gels, although the enzyme was highly active in the adsorbed state. The results and the use of amphophilic gels are discussed.

Agar↗

Liquid chromatography-UV determination and liquid chromatography-atmospheric pressure chemical ionization mass spectrometric characterization of sitosterol and stigmasterol in soybean oil.

A narrow-bore HPLC-UV method was developed for the analysis of two of the more abundant naturally occurring phytosterols in vegetable oils: sitosterol and stigmasterol. The method enabled detection of the compounds at a concentration of 0.42 microg/ml and quantitation at concentrations of 0.52 and 0.54 microg/ml for sitosterol and stigmasterol, respectively. An excellent linearity was determined over two orders of concentration magnitude (r2 0.999-1.000) and verified by applying the Mandel fitting test (p>0.099) and the lack-of-fit test (p>0.057) performed at the 95% confidence level. A good intra-day precision ranging from 0.15 to 1.16% was calculated at two concentration levels (2 and 100 microg/ml). The inter-day reproducibility was verified on 3 different days by performing an homoscedasticity test and analysis of variance. A solid-phase extraction method was developed on silica cartridges for the isolation of phytosterols from soybean oil providing recovery values of 101+/-9 and 106+/-7% for sitosterol and stigmasterol, respectively. Good accuracy of the method was statistically demonstrated since no matrix effect was found for both the analytes. The developed method was applied to the quantitative assay of phytosterols in a soybean oil sample (61+/-5 mg/100 g of stigmasterol and 118+/-4 mg/100 g sitosterol). The HPLC-atmospheric pressure chemical ionization MS technique enabled the identification of stigmasterol, sitosterol and campesterol in the oil sample.

Atmospheric Pressure↗