At least 1,117 records · Page 62Linked to original sources

Managing bruxism and temporomandibular disorders using a centric relation occlusal device.

This article discusses the rationale, indications, and fabrication of the centric relation occlusal (CRO) device in the management of bruxism and temporomandibular disorders. Five methods of fabricating occlusal devices are briefly discussed. Two methods, preferred by the authors, are discussed in detail, including the laboratory phase. One method uses heat-cured acrylic resin, and the other method uses a heat-vacuum machine, thermoplastic splint resin material, and autopolymerizing clear acrylic resin. The use of the CRO device in the successful management of bruxism and temporomandibular disorders has been previously documented in the literature. Some patients may not successfully adjust to the wearing of occlusal devices (splints), which are not well-defined in terms of occlusal morphology, anterior guidance, and their relativity to centric relation. This problem usually is overcome when the dentist uses precise skill in the fabrication and delivery of a CRO device with mutually protected articulation.

Acrylic Resins↗

In vitro mechanical property comparison of four resins used for fabrication of provisional fixed restorations.

PURPOSE: This study recorded and compared the flexural elastic moduli and moduli of rupture of four materials (Provipont DC resin, Triad provisional restorative material, Jet acrylic resin, and a 50:50 mixture of Jet acrylic resin and orthodontic resin) used to make provisional restorations. MATERIAL AND METHODS: Thirty-nine identical 63 x 10 x 3 mm specimens were made from each of the four materials. After 24 hours, 30 days, and 60 days of water storage at 37 degrees C (13 specimens each), standard three-point bend tests were conducted on an Instron universal testing machine at a crosshead speed of 0.5 cm/minute. Stress strain curves were generated, and values for the flexural elastic moduli and moduli of rupture were calculated. Data were subjected to two-way and one-way analyses of variance (alpha = 0.05). RESULTS: Provipont DC resin exhibited significantly higher flexural elastic moduli and moduli of rupture values at the 24-hour test time. However, Provipont DC resin exhibited the greatest decrease in these values over time.

Acrylic Resins↗

Wetting the repair surface with methyl methacrylate affects the transverse strength of repaired heat-polymerized resin.

This study investigated the transverse strength of repaired test specimens of heat-cured acrylic resin. The repair surfaces of the specimens were wetted with methyl methacrylate for various amounts of time before the autopolymerizing acrylic resin was applied to the joint space. A three-point loading test was used to determine the transverse strength of the test specimens, and the morphologic changes in the methyl methacrylate-wetted repair surface was analyzed by scanning electron microscopy. Visual inspection was used to determine whether the failures were adhesive or cohesive. The results revealed that repaired test specimens were weaker than those unrepaired (p < 0.001). The strength of the test specimens increased as the duration of methyl methacrylate wetting of the repair surfaces increased (p < 0.001). Furthermore, the number of adhesive failures was small if the repair surfaces were adequately wetted with methyl methacrylate. Scanning electron micrographs revealed that after 60- and 180-second wetting periods, the poly(methyl methacrylate) was noted to be dissolved with a smooth surface texture. This study suggests that proper wetting of the repair surface makes an important contribution to the strength of repaired acrylic resin.

Acrylic Resins↗

An investigation of the variables which may affect the bond between plastic teeth and denture base resin.

OBJECTIVES: The failure of the bond between acrylic resin denture base material and resin teeth remains a significant problem. This study evaluated the tensile bond strength of specimens produced by commonly employed tooth preparation and processing methods as used in dental laboratories. METHODS: Twenty-two experimental groups, each consisting of 36 specimens, were investigated by subjecting the tooth-resin bond to tensile loading. The groups were allocated to one of five experimental sets to investigate: (a) effect of resin dough time, (b) effect of tooth surface condition, (c) effect of processing variables, (d) effect of monomer cementing, and (e) effect of acrylic resin cement. The results were analysed statistically using a one factor ANOVA and a Student t test. RESULTS: A significantly stronger bond was obtained when the resin was packed late in the dough stage, and a superior bond, in all cases, when high-impact resin was used. Tooth surface modification by grinding or grooving made no significant difference when compared with unmodified surfaces. Wax-contaminated surfaces produced highly significant weaker bonds. Time of introduction and duration of water-bath processing had no significant effect on bond strength. Monomer cementing of the tooth surface, especially with high-impact monomer. significantly improved the bond strength. The application of resin cements was found to produce the most significant increase in denture tooth bond strength. CONCLUSIONS: The important steps in obtaining a consistently high value denture tooth bond are thorough dewaxing of the tooth surface followed by the application of a suitable resin cement.

Acrylic Resins↗

Technique for making a template for temporary restorations.

A fast, accurate, and simple technique for fabricating custom templates used to construct customized acrylic resin temporary crowns and fixed partial dentures has been presented. Acrylic resins are used directly on the diagnostic cast to restore single tooth contours, secure pontics to the cast, and to contour edentulous areas. Duplicate casts and impressions are not needed. Acrylic resins prove superior to wax and other materials for constructing custom templates because they will not distort or melt under the heat and pressure of the thermal vacuum machine. Thus, the template is accurate and free of melted residue on the inner template surface.

Acrylic Resins↗

[Allergies to cosmetics].

The protean clinical delayed hypersensitivity reactions or the less common immediate hypersensitivity reactions can raise major diagnostic challenges, particularly as sensitisation can occur directly, indirectly or from a distance, with the allergen being handborne, airborne, or transmitted vicariously. Identification of the offending allergen among the vast array of potential candidates requires an exhaustive evaluation. The most common offenders are fragrances, which are ubiquitous, being found in a host of known or occult sources preservatives, hair dyes, excipient component, formaldehyde resins, and acrylic resins.

Cosmetics↗

Relining dentures with metal bases.

Metal bases are common in both complete and removable partial dentures. Before the introduction of adhesive denture base material, relining of these bases was almost impossible. This article presents a case on the technique of relining a partial denture metal base, using a 4-META resin (Acrylic Solder). With this technique, metal base can be relined easily in the dental office.

Acrylic Resins↗

Studies on mechanical properties of denture base material laminated with organic fiber reinforced plastics. Part I. Basic consideration of hybrid construction.

Acrylic resin is widely used as a denture base material, but the upper complete denture fails often during use. Therefore, the denture base made from acrylic resin should be reinforced in some way. Therefore, as a new method of reinforcement on the denture base, the authors devised a method to improve the strength and rigidity by laminating the palatal surface of the denture base with an organic fiber reinforced plastic, the so-called canapé construction. In this paper, as the basic experiment, the flexural strength, fatigue strength and the modulus of elasticity in bending of reinforced acrylic resin by the canapé construction were investigated. As the results, the flexural and fatigue strength are improved respectively 160% and 130% compared to the denture base acrylic resin. And the modulus of elasticity in bending is improved 80%. Therefore, it is considered that this new combination of materials using the canapé construction might be sufficiently applied to the denture base.

Acrylic Resins↗

Direct bonding to typodont teeth.

Three methods of bonding orthodontic brackets to acrylic teeth were investigated for use with a typodont. One-hundred-and-twenty Dentaurum 0.018 x 0.025 inch standard Edgewise brackets were bonded to Crylopax cross-linked acrylic teeth using three cements: Concise composite, Concise with acrylic primer, and GAC acrylic cement on a previously roughened tooth surface. Half the specimens in each group was immersed in a thermostatically controlled water bath for 15 min on 20 occasions over a 5-day period, to simulate the conditions of a typodont, prior to measuring tensile bond strength on an Instron machine. Under dry conditions Concise composite was significantly stronger than either Concise with acrylic primer or GAC cold cure acrylic resin. Under wet conditions, however, the mean bond strength of the acrylic resin increased significantly compared to the other cements. The bond strength of both Concise and Concise composite with primer deteriorated following water immersion. It is suggested that when setting up typodont teeth with brackets bonded with GAC acrylic resin, immersion of the bonded teeth in hot water prior to positioning of the teeth in the typodont may greatly reduce the risk of subsequent bracket loss.

Acrylic Resins↗

Influence of bone quality on the stress distribution. An in vitro experiment.

Adequate bone quality and stress distribution to the bone are of decisive importance for implant success. The purpose of this in vitro study was to investigate the influence of bone quality on the stress distribution using 2 implant-bone mimicking models, simulating compact and cancellous bone quality. The resin model was made of an acrylic resin only simulating compact bone quality. The hybrid model was made of 2 kinds of materials, acrylic resin covered with a 1-mm layer of urethane to simulate cancellous bone quality. An implant was embedded in each model, and the abutment and suprastructures were connected to the implant. A strain gauge was placed perpendicular to the implant on the surface of the model and a small accelerometer was attached to the abutment. When an impact load was applied to the suprastructure, both strain and acceleration were measured. Both abutment acceleration and surface strain in the hybrid model decreased rapidly as time progressed when compared to the resin model. Abutment accelerations in the resin model were significantly lower than those in the hybrid model. In the hybrid model, the strain increased as the loading site was moved closer to the strain gauge. The influence of loading sites on strain in the resin model was greater than in the hybrid model. Therefore, the occlusal stress was distributed more widely in the hybrid model than in the resin model. This may indicate that occlusal stress in compact bone may have a tendency to concentrate in particular regions.

Acrylic Resins↗

Effect of microwave disinfection on the hardness and adhesion of two resilient liners.

STATEMENT OF PROBLEM: Microwave irradiation has been suggested for denture disinfection. However, the effect of this procedure on the hardness and bond strength between resilient liners and denture base acrylic resin is not known. PURPOSE: This study evaluated the effect of water storage time and microwave disinfection on the hardness and peel bond strength of 2 silicone resilient lining materials to a heat-polymerized acrylic resin. MATERIAL AND METHODS: Acrylic resin (Lucitone 199) specimens (75 x 10 x 3 mm) were stored in water at 37 degrees C (2 or 30 days) before bonding (n = 160). The resilient lining materials (GC Reline Extra Soft and Dentusil) were bonded to the denture base and divided into the following 4 groups (n = 10): Tests performed immediately after bonding (control); specimens immersed in water (200 mL) and irradiated twice, with 650 W for 6 minutes; specimens irradiated daily for 7 total cycles of disinfection; specimens immersed in water (37 degrees C) for 7 days. Specimens were submitted to a 180-degree peel test (at a crosshead speed of 10 mm/min) and the failure values (MPa) and mode of failure were recorded. Pretreatment and posttreatment hardness measurements (Shore A) of the resilient materials were also performed. Three-way analysis of variance, followed by the Tukey HSD test, was performed (alpha = .05). RESULTS: The analysis revealed that, for all conditions, the mean failure strengths of GC Reline Extra Soft (0.95-1.19 MPa) were significantly higher ( P < .001) than those of Dentusil (0.45-0.50 MPa). The adhesion of the liners was not adversely affected by water storage time of Lucitone 199 or microwave disinfection. All peel test failures were cohesive. There was a small but significant difference ( P < .001) between the pretreatment (34.33 Shore A) and posttreatment (38.69 Shore A) hardness measurements. CONCLUSION: Microwave disinfection did not compromise the hardness of either resilient liners or their adhesion to the denture base resin Lucitone 199.

Acrylic Resins↗

Bonding of resin teeth to the polymethyl methacrylate denture base material.

The objective of this study was to compare bonding of acrylic resin teeth treated in various ways to the polymethyl methacrylate (PMMA) denture base material. The joint surface of each acrylic tooth cured to heat-cured or autopolymerizing PMMA was either untreated, ground, or adjusted with mechanical retention. The bond to the PMMA was tested with a three-point loading test. To determine whether the bond failure was adhesive or cohesive, the fracture surfaces were analyzed visually and by scanning electron microscopy. The highest bond strength to both the heat-cured and the autopolymerizing PMMA was obtained by grinding grooves on the joint surface of an acrylic resin tooth before it was cured to the PMMA (p < 0.001). Heat-cured PMMA did not adhere to the acrylic resin tooth better than the autopolymerizing PMMA did (p > 0.05).

Acrylic Resins↗

Influence of prosthesis material on the loading of implants that support a fixed partial prosthesis: in vivo study.

BACKGROUND: Since loading is increasingly believed to be a determining factor in the treatment outcome with oral implants, there is a need to expand the knowledge related to the biomechanics of oral implants and its influencing factors. PURPOSE: The aim of this study was to investigate the influence of prosthesis material on the distribution and magnitude of load on oral implants carrying a fixed partial prosthesis by in vivo quantification and qualification of this load. METHODS: Eight patients with in total nine three-unit fixed partial prostheses on three implants and three patients with in total four two-unit fixed partial prostheses on two implants were selected. Both metal and acrylic resin prostheses were made. Strain gauged abutments were used to measure the load on the supporting implants during controlled load application of 50 N on several positions along the occlusal surface of the prostheses and during maximal biting in maximal occlusion. Additional tests were conducted when the three-unit prostheses were supported only by two implants, thereby creating an extension pontic. RESULTS: A significantly better distribution of bending moments with the metal prostheses in comparison to the acrylic resin prostheses was observed in the case of the three-unit prostheses on two implants. No other difference in load or load distribution with the different prosthesis materials was noted. CONCLUSION: The clinical significance of the study reveals an increased risk for bending overload of the implants that are closest to the point of load application only in the case of acrylic resin long span prostheses or acrylic resin prostheses with extensions.

Acrylic Resins↗

Shear bond strength between composite resin and denture teeth: effect of tooth type and surface treatments.

PURPOSE: The purpose of this study was to investigate the strength of the composite resin-denture tooth bond as affected by different tooth surface treatments. MATERIALS AND METHODS: Spectrum TPH was condensed on 112 mandibular first molar acrylic resin and composite resin denture teeth, which received seven different treatments: Four groups were treated with Prime & Bond NT adhesive, and three groups were treated with One Step adhesive. Four groups (two of each adhesive category) were treated with Composite Activator and air abrasion. In one group, AeliteFlo was used just before the condensation of Spectrum TPH. Bond strength was evaluated with a shear test device on a Monsanto testing machine. The results were evaluated statistically with two-way ANOVA and the Scheffé method. RESULTS: There was a significant interaction between denture tooth type and surface treatments. Bond strength of composite resin was greater to composite than to acrylic resin teeth when the bond was mediated only with adhesives. One Step adhesive and AeliteFlo resulted in a higher bond of composite resin to both types of teeth. Wetting tooth surfaces with Composite Activator did not increase the bond. CONCLUSION: When repairing denture teeth with composite resin and adhesives, the bond strength was higher with composite than with acrylic resin teeth, and there were differences between the adhesives used.

Acid Etching, Dental↗

A one-appointment procedure for cast post and core restorations.

An accelerated method of using a light-cured acrylic resin and rapid burnout for casting a direct-pattern post and core restoration is presented. Light-cured acrylic resins are an alternative to chemically cured acrylic resins or indirect patterns formed from an elastomeric impression. The procedure can eliminate an appointment for the patient in the fabrication of the post and core restoration and can be completed in most dental offices with minimal laboratory facilities. Chair-side time is saved because of the elimination of one provisional restoration when two are usually required. Laboratory time is also saved because of the decrease in investment setting and burnout time.

Acrylic Resins↗