Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Solvent dependence of dynamic transitions in protein solutions.

A transition as a function of increasing temperature from harmonic to anharmonic dynamics has been observed in globular proteins by using spectroscopic, scattering, and computer simulation techniques. We present here results of a dynamic neutron scattering analysis of the solvent dependence of the picosecond-time scale dynamic transition behavior of solutions of a simple single-subunit enzyme, xylanase. The protein is examined in powder form, in D(2)O, and in four two-component perdeuterated single-phase cryosolvents in which it is active and stable. The scattering profiles of the mixed solvent systems in the absence of protein are also determined. The general features of the dynamic transition behavior of the protein solutions follow those of the solvents. The dynamic transition in all of the mixed cryosolvent-protein systems is much more gradual than in pure D(2)O, consistent with a distribution of energy barriers. The differences between the dynamic behaviors of the various cryosolvent protein solutions themselves are remarkably small. The results are consistent with a picture in which the picosecond-time scale atomic dynamics respond strongly to melting of pure water solvent but are relatively invariant in cryosolvents of differing compositions and melting points.

Calorimetry, Differential Scanning↗

Dynamic MR imaging of neurohypophyseal germ cell tumors for differential diagnosis of infundibular diseases.

PURPOSE: To investigate the MR dynamic patterns of neurohypophyseal germ cell tumors (GCTs) for differential diagnosis of infundibular diseases affecting young people. MATERIAL AND METHODS: Eleven patients with neurohypophyseal GCTs underwent dynamic MR studies with Tl-weighted spin-echo (SE) or turbo SE techniques. Other infundibular lesions, including adenohypophysitis (n=3), Langerhans' cell histiocytosis (LCH, n=2), and 1 hemangioblastoma from von Hippel-Lindau disease, were also evaluated. Serial images were obtained every 15 s (turbo SE) or 30 s (SE technique) for 240 s after rapid injection of contrast medium. The dynamic patterns were analyzed quantitatively with the contrast medium enhancement ratio. RESULTS: On dynamic MR images, GCTs typically showed a gradual enhancement increase with a peak between 105 s and 180 s, while two showed a relatively rapid increase. LCH and hemangioblastoma showed a dynamic pattern similar to GCTs, while adenohypophysitis demonstrated a sharp rise and a steeper wash-out with an obvious peak before 90 s. CONCLUSION: Typical dynamic pattern of GCTs was the gradual enhancement increase without wash-out. Dynamic MR imaging can distinguish GCTs from adenohypophysitis, but is not useful for differentiation from LCH.

Adolescent↗

Dynamic scintigraphy of bone and bone marrow in multiple myeloma patients with bone-marrow transplants.

PURPOSE: To determine whether dynamic registration at bone and bone-marrow scintigraphy produces additional information compared to subsequent static registrations of bone-marrow transplants in multiple myeloma patients. MATERIAL AND METHODS: In a prospective study, 8 dynamic bone and 6 dynamic bone-marrow scintigraphies were performed in 10 patients. The dynamic scintigraphies were compared with conventional radiography, MR images, and static scintigraphies of bone and bone marrow. RESULTS: No additional information was revealed by the dynamic registration method; on the contrary, 4 of the 8 known lesions were not discerned at dynamic registration. An incidental observation was that the time-activity curves of both radiopharmaceuticals had a specific pattern. CONCLUSION: Dynamic registration at bone and bone-marrow scintigraphy was not useful for detecting disease in multiple myeloma lesions.

Adult↗

NMR evidence for base dynamics at all TpA steps in DNA.

NMR evidence is presented indicating that the exceptional conformational dynamics found at TpA steps in DNA is general to all immediate sequence contexts. One easily tractable NMR parameter that is sensitive to TpA base dynamics is the resonance linewidth of the TpA adenine H2 proton. This resonance experiences a temperature-dependent broadening due to conformational dynamics. Unusual dynamics at TpA steps were originally observed in the sequence context (T)pTpTpApAp(A). We have since shown that the evidence for TpA dynamics persists when either the thymine preceding the TpA step or the adenine following the TpA step is preserved [McAteer et al., Nucleic Acids Res. 23, 3962-3966 (1995)]. Here, in order establish whether or not exceptional TpA dynamics occurs in all DNA sequence contexts, we investigated a series of DNA sequences of the form GCNaTANbNbTANaGC, where N=A,T,C,G. In this family of sequences, all 16 possible immediate sequence context environments of the form NaTANb were examined using 10 DNA sequences. Our NMR results show that the TpA adenine H2 resonance contains a temperature dependent excess linewidth indicative of dynamics in all 16 sequence context environments. By studying a complete set of sequence contexts, it was possible to recognize trends relating resonance parameters and sequence environment. For example, the magnitude of the maximum linewidth is largely determined by the identity of the nucleotide following the TpA step and the magnitude of the linewidth maximum is moderately correlated (r=0.56) with the temperature of the linewidth maximum. The physical basis for these correlations is discussed.

Adenine↗

Taxol suppresses dynamics of individual microtubules in living human tumor cells.

Microtubules are intrinsically dynamic polymers, and their dynamics play a crucial role in mitotic spindle assembly, the mitotic checkpoint, and chromosome movement. We hypothesized that, in living cells, suppression of microtubule dynamics is responsible for the ability of taxol to inhibit mitotic progression and cell proliferation. Using quantitative fluorescence video microscopy, we examined the effects of taxol (30-100 nM) on the dynamics of individual microtubules in two living human tumor cell lines: Caov-3 ovarian adenocarcinoma cells and A-498 kidney carcinoma cells. Taxol accumulated more in Caov-3 cells than in A-498 cells. At equivalent intracellular taxol concentrations, dynamic instability was inhibited similarly in the two cell lines. Microtubule shortening rates were inhibited in Caov-3 cells and in A-498 cells by 32 and 26%, growing rates were inhibited by 24 and 18%, and dynamicity was inhibited by 31 and 63%, respectively. All mitotic spindles were abnormal, and many interphase cells became multinucleate (Caov-3, 30%; A-498, 58%). Taxol blocked cell cycle progress at the metaphase/anaphase transition and inhibited cell proliferation. The results indicate that suppression of microtubule dynamics by taxol deleteriously affects the ability of cancer cells to properly assemble a mitotic spindle, pass the metaphase/anaphase checkpoint, and produce progeny.

Adenocarcinoma↗

Dynamics of microtubules from erythrocyte marginal bands.

Microtubules can adjust their length by the mechanism of dynamic instability, that is by switching between phases of growth and shrinkage. Thus far this phenomenon has been studied with microtubules that contain several components, that is, a mixture of tubulin isoforms, with or without a mixture of microtubule-associated proteins (MAPs), which can act as regulators of dynamic instability. Here we concentrate on the influence of the tubulin component. We have studied MAP-free microtubules from the marginal band of avian erythrocytes and compared them with mammalian brain microtubules. The erythrocyte system was selected because it represents a naturally stable aggregate of microtubules; second, the tubulin is largely homogeneous, in contrast to brain tubulin. Qualitatively, erythrocyte microtubules show similar features as brain microtubules, but they were found to be much less dynamic. The critical concentration of elongation, and the rates of association and dissociation of tubulin are all lower than with brain microtubules. Catastrophes are rare, rescues frequent, and shrinkage slow. This means that dynamic instability can be controlled by the tubulin isotype, independently of MAPs. Moreover, the extent of dynamic behavior is highly dependent on buffer conditions. In particular, dynamic instability is strongly enhanced in phosphate buffer, both for erythrocyte marginal band and brain microtubules. The lower stability in phosphate buffer argues against the hypothesis that a cap of tubulin.GDP.Pi subunits stabilizes microtubules. The difference in dynamics between tubulin isotypes and between the two ends of microtubules is preserved in the different buffer systems.

Animals↗

The effects of sequence context on base dynamics at TpA steps in DNA studied by NMR.

Base dynamics, heretofore observed only at TpA steps in DNA, were investigated as a function of sequence context by NMR spectroscopy. The large amplitude conformational dynamics have been previously observed in TnAn segments where n > or = 2. In order to determine whether the dynamic characteristics occur in more general sequence contexts, we examined four self-complementary DNA sequences, [d(CTTTA-NATNTAAAG)2] (where N = A, C, T, G and N = complement of N). The anomalous broadening of the TpA adenine H2 resonance which is indicative of large amplitude base motion was observed in all nine unique four nucleotide contexts. Furthermore, all the adenine H2 resonances experienced a linewidth maximum as a function of temperature, which is a characteristic of the dynamic process. Interestingly, the temperature of the linewidth maximum varied with sequence indicating that the thermodynamics of TpA base dynamics are also sequence dependent. In one example, neither a T preceding nor an A trailing the TpA step was required for base dynamics. These results show that base dynamics, heretofore observed in only a few isolated sequences, occurs at all TpA steps which are either preceded or followed by a thymine or adenine, respectively, and may be characteristic of all TpA steps in DNA notwithstanding sequence context.

Adenine↗

Relationship of tutors' group-dynamics skills to their performance ratings in problem-based learning.

PURPOSE: A tutor's performance is often investigated as a stable teacher characteristic, isolated from the context in which the tutor functions. This study investigated the influence of a tutor's group-dynamics skills in differently functioning tutorial groups on performance ratings. METHOD: Students' ratings of tutors' performances collected from 75 tutorial groups at one school over four different academic years were compared with the independent variables, groups' cohesion scores and sponging scores (the degree to which some students let others do the work), and the intervening variable, tutors' group-dynamics skills. RESULTS: Tutors with strong group-dynamics skills were assigned mean tutor's-performance scores of 7.4 (SD = 0.8) and 8.2 (SD = 0.5), respectively, by groups scoring low and high on cohesion. Tutors with low group-dynamics skills were rated 7.0 (SD = 1.1) and 7.4 (SD = 1.1) by the same groups. The same pattern held for sponging scores. Tutors who had strong group-dynamics skills received mean tutor's-performance scores of 8.1 (SD = 0.6) and 7.4 (SD = 0.8), respectively, from groups with low and high sponging scores. Tutors with weak group-dynamics skills were scored 7.6 (SD = 1.0) and 6.9 (SD = 1.1) by the same groups. CONCLUSIONS: Tutors possessing group-dynamics skills were rated higher by students than were tutors who lacked these skills, irrespective of the quality of a tutorial group's performance. A tutor who evaluates tutorial-group function on a regular basis and makes appointments with students based on these evaluations is seen as performing better than a tutor who does not.

Analysis of Variance↗

Dynamic MRI of small renal cell carcinoma.

OBJECTIVE: To evaluate the appearance of contrast-enhanced dynamic MRI of small renal cell carcinoma (RCC) (< 3 cm diameter). MATERIALS AND METHODS: Twenty-seven patients with 28 small RCCs were studied by both conventional spin echo and contrast-enhanced dynamic MRI for tumor detection and characterization. All tumors were detected by contrast-enhanced CT and confirmed by operation. Dynamic MRI was performed using a breath-hold fast low angle shot technique after rapid injection of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Characterization of a renal mass was done by the visual analysis of tumor vascularity as well as quantitative assessment of the contrast noise ratio (CNR) and degree of enhancement. RESULTS: With conventional spin echo MR and dynamic MR, 18 and 26 of 28 small RCCs were detected, respectively. In the dynamic study the tumor/renal medulla contrast was marked at 90-120 s after administration of Gd-DTPA (CNR:15.1). The tumor/renal medulla contrast in the dynamic study was more marked than that of postcontrast T1-weighted imaging (CNR, -0.25); T2-weighted imaging (CNR, 3.1); and T1-weighted imaging (CNR, -0.76). CONCLUSION: Contrast-enhanced dynamic MRI is a useful technique for the diagnosis of small RCC especially in a patient with renal insufficiency or allergy to iodinated contrast material.

Adult↗

Effects of axial dynamization on bone healing.

The effects of early dynamization (physiologic axial compression) on canine fracture healing at six weeks were studied. Bilateral transverse mid-tibial osteotomies were created and initially stabilized with a 2-mm gap using relatively rigid external fixators. Seven days after osteotomy, the telescoping mechanism of one of the fixators on each dog was released (dynamized), resulting in physiologic loading of the osteotomy, while the contralateral fixator remained locked as a rigid control. The dynamized osteotomy closed, and increased functional weight bearing resulted from 3 weeks on. Radiographically the amount of periosteal callus increased over time, but no difference in callus size was seen between the dynamized fractures and the controls. Torsional mechanical testing found the dynamized osteotomies to be significantly stiffer, and they tended to tolerate more maximum torque than the controls. Microscopic evaluation found no difference in the volume of the periosteal and endosteal calluses or in the tissues constituting them. However, a significantly greater proportion of the dynamized osteotomy gap was filled with new bone. These results suggest that dynamization in this delayed union model improved fracture healing by reducing fracture gap size and increasing weight bearing, not by altering the pathway of fracture healing.

Animals↗

The effect of dynamization on slowing the healing of femur shaft fractures after interlocking nailing.

OBJECTIVE: The aim of this retrospective study was to investigate the effect of dynamizing a static interlocking nail to promote femoral fracture healing and the adverse effect of dynamization. MATERIALS AND METHODS: Twenty-eight static femoral interlocking nails were dynamized after 4 months (median, 6 months; range, 4-12 months) because of poor fracture healing. The clinical and roentgenographic healing processes were recorded. Significant complications were treated and analyzed. RESULTS: Twenty-four patients were followed for at least one year (median, 32 months; range, 13-49 months). Fourteen patients (58%) achieved a solid union with a union period of 5.2 +/- 2.0 months after dynamization. Twenty-one percent of patients (5 of 24) had more than 2 cm of femoral shortening; all occurred in cases of nonunion (p < 0.01, Fisher's exact test). All 10 cases of nonunion were treated with cancellous bone grafting with or without lengthening and achieved satisfactory outcomes. CONCLUSIONS: Dynamization is a method that can be tried to improve fracture healing in femoral fractures that show delayed healing after interlocking nailing. In my experience, however, not all cases achieve union after dynamization. Patients must be examined regularly after dynamization to avoid significant shortening.

Adult↗

The discrepancy between 99Tcm-ECD dynamic and static SPET images in patients with ischaemic lesions corresponds to reduced vasoreactivity to acetazolamide.

We evaluated 99Tcm-N,N'-(1,2-ethylenediyl)bis-L-cysteine diethyl ester (99Tcm-ECD) dynamic and static SPET (single photon emission tomographic) images to examine 99Tcm-ECD kinetics under ischaemic cerebrovascular conditions. In 20 patients who showed arterial occlusion on magnetic resonance angiography, dynamic (0-10 min) and static (15-35 min) SPET images were acquired after the intravenous administration of 99Tcm-ECD. Thirteen of the patients had focal perfusion deficits that were more evident on the dynamic than on the static images; the other seven showed no such discrepancy. In those patients with a mismatch between the dynamic and static images, the extent corresponded to reduced vaso-reactivity to acetazolamide. Based on quantitative analysis of the ratio of tracer uptake in affected to that in unaffected areas, the patients with discrepant findings showed significantly different ratios on the dynamic and static images, whereas those with no such mismatch did not. Our results suggest that dynamic 99Tcm-ECD images provide circulatory information and that static images reflect a filling-in phenomenon of ECD metabolites in ischaemic lesions. 99Tcm-ECD dynamic and static SPET images offer an alternative method of detecting mild perfusion deficits without the need for acetazolamide challenge.

Acetazolamide↗

Dynamic 99Tcm-ECD SPET correlates well with 201Tl indices in brain tumours.

The dynamic 99Tcm-ethyl cysteinate dimer (99Tcm-ECD) single photon emission tomographic (SPET) characteristics of brain tumours were investigated and compared with 201Tl-chloride SPET indices. Thirty-five patients with histologically confirmed benign and malignant tumours were evaluated using dynamic and standard 99Tcm-ECD. Twenty-eight patients were also examined using standard 201Tl SPET. The following 201Tl indices were calculated: early uptake ratio, delayed uptake ratio, washout rate and retention index. The relationship between uptake of 99Tcm-ECD on dynamic SPET and 201Tl indices was analysed. Nine patients showed positive uptake on dynamic 99Tcm-ECD SPET, all of whom had benign tumours, including five meningothelial meningiomas, three pituitary adenomas of the chromophobe type and one chemodectoma without malignancy. The mean early uptake ratio of the tumours with positive uptake was significantly higher than that of the tumours with negative uptake (17.1 +/- 5.5 vs 9.0 +/- 5.7, P = 0.004). The mean washout rate of the tumours with positive uptake was significantly higher than that of the tumours with negative uptake (61.0 +/- 27.7 vs 0.35 +/- 30.9, P = 0.0004). The mean retention index of the tumours with positive uptake was significantly lower than that of the tumours with negative uptake (0.27 +/- 0.12 vs 0.88 +/- 0.48, P = 0.000006). Only benign tumours showed positive uptake on dynamic 99Tcm-ECD SPET. The 201Tl indices correlated well with the uptake of 99Tcm-ECD on dynamic SPET. The results suggest that dynamic 99Tcm-ECD SPET can identify the benign character of tumours of the brain.

Adult↗

Effects of rigid contact lens prism ballasting on oxygen access to the cornea under static and dynamic conditions.

The effects of rigid contact lens material [polymethyl methyacrylate (PMMA) and itabisfluorofocon A] and prism ballasting (0, 1.5, 2.25, and 3 delta) on tear pump efficiency were studied by measuring corneal oxygen uptake rates on the right eyes of six human subjects under three conditions: (1) normal open eye; (2) after 5 min of static (without blinking) wear of the contact lens; and (3) after 5 min of dynamic (with blinking once every 5 s) wear of the same lens. As expected, corneal oxygen uptake rates (i.e., demand for oxygen) measured with the itabisfluorofocon A material were significantly lower (p < 0.0001) than those measured with PMMA under both static and dynamic conditions. Under static conditions, no significant differences were found across materials among the corneal oxygen uptake rates associated with the four amounts of prism ballasting (p = 0.0514). However, under dynamic conditions, significant differences (p < 0.0001) were found across materials among corneal oxygen uptake rates associated with the four amounts of prism ballasting, with the lower amounts of prism ballasting being associated with lower corneal oxygen uptake rates. The changes in the measured corneal oxygen uptake rates from static to dynamic conditions, relative to those measured for the normal open eye, served as an index of tear pump efficiency. There were no significant differences in these changes for the prism amounts studied; however, static condition data were significantly higher than dynamic condition data for the 0 delta and 1.5 delta lenses only, whereas greater amounts of prism ballasting resulted in no reduction in oxygen uptake under dynamic conditions. In addition, significantly greater differences between static and dynamic condition data were found for the PMMA material than for itabisfluorofocon A.

Adult↗

Anal sphincter reconstruction with the gluteus maximus muscle: anatomic and physiologic considerations concerning conventional and dynamic gluteoplasty.

Myoplasties have acquired an important place in anal sphincter repair. The use of the gluteus maximus muscle for sphincterplasty was reported initially in 1902. However, in 1952, the gracilis sphincterplasty became more popular because of the accessibility of this muscle. Unfortunately, continence rates, especially after graciloplasty, remained unpredictable because of inability to maintain muscle contraction despite training programs. Training should induce a shift in muscle fiber type distribution toward a more fatigue-resistant composition, with predominance of type I fibers. In order to obtain a more pronounced adaptation in the contractile, histochemical, and metabolic properties of muscle fibers, postoperative intermittent long-term stimulation of the graciloplasty was performed. As these results and the results of dynamic cardiomyoplasty with an implantable myostimulator proved to be successful, implantable pulse generators were used after graciloplasty. Subsequently, continence rates after graciloplasties improved significantly. These data encouraged us to perform dynamic gluteoplasties for anal sphincter repair. This paper presents the results in 7 patients treated by conventional and 4 patients treated by dynamic gluteoplasty. Advantages and disadvantages of gluteoplasty were compared with those of graciloplasty. The neurovascular pedicle of the gluteoplasty underwent less traction after transposition compared with the graciloplasty based on cadaver studies. Gluteus muscle transfer far exceeded the amount of muscle tissue of a normal anal sphincter despite muscle atrophy after transposition. This guaranteed a contractile muscle cuff around the anal canal in contrast to the tendinous sling after graciloplasty. Because of the excellent vascularization of the muscle, microperforations of the rectal mucosa caused by submucosal dissection were sealed, and implantation of electrodes and a pulse generator in one surgical intervention was well tolerated. The myoplasty induced a double curvation of the anal canal in contrast to the graciloplasty, which enhanced the natural anorectal angle. Patient evaluation revealed continence for stool in 9 of the 11 patients; 7 of the 11 patients also were continent for liquids, among them all of the patients who had undergone dynamic gluteoplasties. Mean basal pressure after dynamic gluteoplasty was 49 mmHg, which is lower than the reported mean basal pressure (62 mmHg) during stimulation after dynamic graciloplasty. Squeeze pressure after gluteoplasty, with or without stimulation, proved to be similar to or higher than that obtained in dynamic graciloplasty. Comparing our results of conventional gluteoplasty with the results of graciloplasty prior to stimulation, higher pressures were obtained by the gluteoplasty, especially in squeeze pressures. In the last 5 patients intraoperative pressure measurements were used to restore the optimal resting length of the muscle after transposition. An intraluminal pressure of at least 40 mmHg during rest and 80 to 120 mmHg during stimulation should be obtained to guarantee a future continent sphincter.

Adult↗

A dynamic approach to spinal instability. Part I: Sensitization of intersegmental motion profiles to motion direction and load condition by instability.

STUDY DESIGN: Human lumbar functional spinal units (FSUs) were moved throughout their range of motion in sagittal and lateral bending while the dynamics of this movement were computed in vitro. Functional spinal units were tested intact and after subsequent discectomy and unilateral facetectomy. OBJECTIVE: To establish "normal" velocity and acceleration curves during lumbar intersegmental bending in the intact FSU and then evaluate the changes of this dynamic behavior due to surgically induced component instability. SUMMARY OF BACKGROUND DATA: In preliminary clinical studies, researchers have provided evidence that dynamic motion measurements may be useful in the assessment of spinal impairment. METHODS: Human lumbar FSUs moved from extension to flexion, flexion to extension, left to right, and right to left a pure moment. Range of motion, as well as velocity and acceleration patterns of the main and coupled motions, were evaluated in six degrees of freedom by position changes of attached infrared light-emitting diodes recorded by cameras. Functional spinal units were tested in three surgical conditions (intact, discectomy, and unilateral facetectomy) under two preload conditions (no preload and 400 N preload). RESULTS: Motion of intact FSUs progressed with velocity and acceleration patterns that were relatively independent from motion direction and preload condition. After surgery, however, the dynamic motion became unequal between opposite motion directions (even if range of motion was equal between directions) and more sensitive to preload condition. CONCLUSION: The results suggest that equilibrium of dynamic motion parameters within a range of motion is an element of segmental stability. From this approach, segmental instability appears to change intersegmental acceleration and velocity patterns as a function of motion direction and load conditions. Whereas dynamic motion patterns in an intact FSU are relatively invariable between reversed motion directions, instability is characterized by a considerable diversity of dynamic motion parameters between reversed motion directions.

Acceleration↗

Dynamic range enhancement for cochlear implants.

HYPOTHESIS: The addition of a continuous, unmodulated, high-rate pulse train to sinusoidal stimuli presented by the cochlear implant to implant recipients will result in increases in the psychophysical dynamic range. BACKGROUND: The hearing dynamic range of cochlear implant patients is markedly reduced compared with that of normal-hearing individuals. This has negative implications for both speech perception and sound quality in these patients. It has been suggested that the addition of an unmodulated high-rate pulse train to deafened auditory nerves could create spontaneous-like neural activity, similar to that recorded from normal ears, of which one significant benefit would be an increase in the dynamic range of cochlear implant users. METHODS: Twenty-nine patients who underwent implantation with the Clarion CII device participated in this single-blinded prospective study. The psychophysical dynamic range of 28 of these subjects was measured with sinusoidal stimuli in response to various levels of an additional unmodulated high-rate pulse train. RESULTS: All the tested subjects (n = 28) demonstrated an increase in dynamic range in response to an appropriate level of unmodulated high-rate pulse train. The largest increase in dynamic range for each subject had a mean value of 6.7 dB. CONCLUSION: The addition of an unmodulated high-rate pulse train to the electric signal presented to cochlear implant patients results in significant increases in dynamic range for sinusoidal stimuli.

Acoustic Stimulation↗

VEGF expression in osteosarcoma correlates with vascular permeability by dynamic MRI.

Dynamic enhanced magnetic resonance imaging has been used to assess tumor angiogenesis in osteosarcoma. Vascular endothelial growth factor has been shown to correlate with pulmonary metastasis and a poor prognosis in osteosarcoma. The purpose of this investigation was to determine whether vascular endothelial growth factor expression in osteosarcoma correlates with vascular permeability detected by dynamic enhanced magnetic resonance imaging and to explore the role of dynamic enhanced magnetic resonance imaging as a noninvasive means of assessing tumor angiogenic activity. Fifty-five osteosarcoma patients with osteosarcoma enrolled in a treatment protocol that included dynamic enhanced magnetic resonance imaging. In 15 patients, tumor tissues were available for vascular endothelial growth factor immunohistochemical studies. A two-compartment model used the exchange rate constants (kep) between the plasma and tumor compartments to quantify vascular permeability during dynamic magnetic resonance imaging studies. Immunohistochemical staining for vascular endothelial growth factor was graded according to the intensity and number of positively stained cells. Vascular endothelial growth factor-positive tumors showed higher mean vascular permeability when compared with vascular endothelial growth factor-negative tumors. Vascular permeability also correlated with increasing vascular endothelial growth factor expression. The preliminary results in this study show an association between vascular endothelial growth factor and dynamic MR signal enhancement in osteosarcoma. Dynamic enhanced magnetic resonance imaging should be investigated as a means to prognosticate osteosarcoma patients with osteosarcoma according to their tumor angiogenic activity.

Adolescent↗