Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Filipin-induced lesions in planar phospholipid bilayers imaged by atomic force microscopy.

Filipin is a macrolide polyene with antifungal activity belonging to the same family of antibiotics as amphotericin B and nystatin. Despite the spectroscopy and electron microscopy studies of its interaction with natural membranes and membrane model systems, several aspects of its biochemical action, such as the role of membrane sterols, remain to be completely understood. We have used atomic force microscopy (AFM) to study the effect of filipin on dipalmitoylphosphatidylethanolamine bilayers in the presence and absence of cholesterol. The bilayers were prepared by Langmuir-Blodgett deposition over mica and imaged under water. It was shown that filipin-induced lesions could only be found in membranes with cholesterol. In close agreement with electron microscopy results, we have reported the presence of densely packed circular protrusions in the membrane with a mean diameter of 19 nm (corrected for convolution with AFM tip) and 0.4 nm height. Larger circular protrusions (90 nm diameter and 2.5 nm height) and doughnut-shaped lesions were also detected. These results demonstrate that filipin-induced lesions in membranes previously observed by electron microscopy are not biased by artifacts resulting from sample preparation. Filipin aggregates in aqueous solution could also be imaged for the first time. These polydisperse spherical structures were observed in samples with and without cholesterol.

Cholesterol↗

An investigation of self-reinforced poly(methyl methacrylate) denture base acrylic resin using scanning electron and atomic force microscopy.

PURPOSE: The aim of this study was to examine the interfacial region of poly(methyl methacrylate) (PMMA) reinforced with untreated and surface-treated PMMA fibers in both chopped and continuous form using scanning electron and atomic force microscopy. MATERIALS AND METHODS: Acrylic resin specimens incorporating untreated and surface-treated (with butadiene styrene latex emulsion) PMMA fibers were examined using a scanning electron microscope and an atomic force microscope. RESULTS: There was evidence of random arrangement of untreated and surface-treated chopped fibers throughout specimens with areas of dense fiber aggregation and other areas containing few or no fibers. For the untreated and surface-treated fibers in continuous forms (a single and 2 unidirectional layers), there was evidence of fiber displacement and buckling, together with variation in interfiber spacing. For the specimens containing surface-treated continuous fibers in a cross-ply arrangement that had demonstrated a substantial improvement in the modulus of rupture, there was no evidence of fiber buckling, and the layer of butadiene styrene was consistently thin and even in comparison to weaker specimens. CONCLUSION: The thickness of the rubber layer and the fiber arrangement (in terms of fiber displacement and interfiber spacing) may be important factors in the success of the reinforcement.

Acrylic Resins↗

Local mobility in lipid domains of supported bilayers characterized by atomic force microscopy and fluorescence correlation spectroscopy.

Fluorescence correlation spectroscopy (FCS) is used to examine mobility of labeled probes at specific sites in supported bilayers consisting of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) lipid domains in 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC). Those sites are mapped beforehand with simultaneous atomic force microscopy and submicron confocal fluorescence imaging, allowing characterization of probe partitioning between gel DPPC and disordered liquid DOPC domains with corresponding topography of domain structure. We thus examine the relative partitioning and mobility in gel and disordered liquid phases for headgroup- and tailgroup-labeled GM1 ganglioside probes and for headgroup- and tailgroup-labeled phospholipid probes. For the GM1 probes, large differences in mobility between fluid and gel domains are observed; whereas unexpected mobility is observed in submicron gel domains for the phospholipid probes. We attribute the latter to domain heterogeneities that could be induced by the probe. Furthermore, fits to the FCS data for the phospholipid probes in the DOPC fluid phase require two components (fast and slow). Although proximity to the glass substrate may be a factor, local distortion of the probe by the fluorophore could also be important. Overall, we observe nonideal aspects of phospholipid probe mobility and partitioning that may not be restricted to supported bilayers.

G(M1) Ganglioside↗

Using atomic force microscopy to investigate patch-clamped nuclear membrane.

Nuclear patch clamp is an emerging research field that aims to disclose the electrical phenomena underlying macromolecular transport across the nuclear envelope (NE), its properties as an ion barrier and its function as an intracellular calcium store. The authors combined the patch clamp technique with atomic force microscopy (AFM) to investigate the structure-function relationship of NE. In principle, patch clamp currents, recorded from the NE can indicate the activity of the nuclear pore complexes (NPCs) and/or of ion channels in the two biomembranes that compose the NE. However, the role of the NPCs is still nuclear because the observed NE current in patch clamp experiments is lower than expected from the known density of the NPCs. Therefore, AFM was applied to link patch clamp currents to structure. The membrane patch was excised from the nuclear envelope and, after electrical evaluation, transferred from the patch pipette to a substrate. We could identify the native nuclear membrane patches with AFM at a lateral and a vertical resolution of 3 nm and 0.1 nm, respectively. It was shown that complete NE together with NPCs can be excised from the nucleus after their functional identification in patch clamp experiments. However, we also show that membranes of the endoplasmic reticulum can contaminate the tip of the patch pipette during nuclear patch clamp experiments. This possibility must be considered carefully in nuclear patch clamp experiments.

Animals↗

Analysis of the interaction between adeno-associated virus and heparan sulfate using atomic force microscopy.

Adeno-associated virus (AAV) has been widely used as a viral vector to deliver genes to animal and human tissues in gene therapy studies. Both AAV-2 and AAV-3 use cell surface heparan sulfate (HS), a highly sulfated polysaccharide, as a receptor to establish infections. In this study, we used atomic force microscopy (AFM) to investigate the interaction of HS and AAV. A silicon chip functionalized with HS was used as a substrate for binding AAV for AFM analysis. To validate our approach, we found that the binding of AAV-2 to the HS surface was effectively competed by soluble HS, suggesting that the binding of AAV-2 to the functionalized surface was specific. In addition, we examined the binding of various AAV serotypes, including AAV-1, AAV-2, AAV-3, and AAV-5, to the HS surface. As expected, only AAV-2 and AAV-3 bound, whereas AAV-1 and AAV-5 did not. This observation was consistent with the previous conclusion that AAV-1 and AAV-5 do not use HS as a receptor for infection. In conclusion, we developed a novel approach to investigate the interaction of AAV virus with its polysaccharide-based receptor at the level of a single viral particle. Given that HSs serve as receptor for numerous viruses, this approach has the potential to become a generalized method for studying interactions between the viral particle and HS, as well as other virus-cell interactions, and potentially serve as a platform for screening antiviral therapies.

Cell Line↗

Measurement of Interaction Forces between Silica and alpha-Alumina by Atomic Force Microscopy

Interaction forces between a silica sphere and an alpha-alumina substrate at various pH values were measured by atomic force microscopy (AFM). As expected, at pH values of 10.8 and 10.2 when the surfaces are similarly charged, a repulsive force was observed. On the other hand, at pH values of 5.5, 6.4, and 8.6 when the surfaces are oppositely charged, attractive forces were observed. Experimental force vs separation distance curves were found to be in good agreement with theoretical predictions based on electrostatic and van der Waals interactions. Interestingly, when the force/radius values at a particular separation distance were plotted against pH, the transition from an attractive to a repulsive force occurred at pH 9.3, which is very close to the point of zero charge (pzc) of alpha-alumina as determined from electrophoresis experiments. These results suggest that AFM force measurements can be used to estimate the pzc of materials. This method may be of particular significance for soluble salt minerals where conventional electrophoretic measurements are not possible at high ionic strengths. Finally, results from transmittance studies further confirmed the interaction between silica and alpha alumina particles in suspensions at various pH values as would be expected based on the results from atomic force microscopy measurements.

Journal Article↗

Atomic Force Microscopy Studies of Membranes: Effect of Surface Roughness on Double-Layer Interactions and Particle Adhesion.

Atomic force microscopy in conjunction with the colloid (silica) probe technique has been used to quantify the variations in electrical double-layer interactions and adhesion at different locations on a rough reverse osmosis membrane (AFC99) surface in NaCl solutions. Prior scanning of the membrane surface with the colloid probe allowed precise location for force measurements. The membrane surface was composed entirely of peaks and valleys with a surface roughness substantially greater than that of most other types of polymeric membranes. The magnitude of the electrical double-layer repulsion between the colloid probe and the membrane at peaks on the membrane surface was greatly reduced compared to that in the valleys. Nevertheless, adhesion of the colloid probe was lower at the peaks on the membrane surface than in the valleys with the difference increasing with decreasing salt concentration, and reaching a factor of more than 20 in 10(-3) M solution. The study shows that minimization of membrane fouling by colloids could be achieved by choosing membranes with a roughness periodicity preventing penetration of foulants into valleys on the surface. Copyright 2000 Academic Press.

Journal Article↗

Conformational change in an isolated single synthetic polymer chain on a mica surface observed by atomic force microscopy.

The random coil conformation of an isolated conventional synthetic polymer chain was clearly imaged by atomic force microscopy (AFM). The sample used was a poly(styrene)-block-poly(methyl methacrylate) diblock copolymer. A very dilute solution of the copolymer with benzene was spread on a water surface. The structure thus formed on water was subsequently transferred and deposited onto mica at various surface pressures and observed under AFM. The AFM images obtained with films deposited at a low surface pressure (<0.1 mN/m) showed a single polystyrene (PS) block chain aggregated into a single PS particle with a single poly(methyl methacrylate) (PMMA) block chain emanating from the particle. Immediately after the deposition, the single PMMA block chain aggregated to form a condensed monolayer around the polystyrene particles. However, after exposing the deposited film to highly humid air for 1 day, the PMMA chains spread out so that the single PMMA block chain could be identified as a random coil on the substrate. The thin water layer formed on the mica substrate in humid air may enable the PMMA block chain to be mobilized on the substrate, leading to the conformational rearrangement from the condensed monolayer conformation to an expanded and elongated coil. The elongation of the PMMA chain was highly sensitive to the humidity; the maximum elongation was obtained at 79% relative humidity. The elongation was a slow process and took about 20 h.

Journal Article↗

Reentrant mound formation in GaAs(001) homoepitaxy observed by ex situ atomic force microscopy

A study of the surface morphology of homoepitaxial GaAs(001) by means of ex situ atomic force microscopy in air reveals the reentrance of mounding behavior at low growth temperatures. A transition from statistical roughening to organized mound formation is observed as the growth temperature is reduced. We show by means of growth simulations that the observed morphology is compatible with anisotropic adatom diffusion in the presence of an Ehrlich-Schwoebel barrier. The mechanism leading to this kind of adatom kinetics at low temperatures is interpreted in terms of surfactant acting arsenic condensing on the surface.

Journal Article↗

Targeting of Helicobacter pylori vacuolating toxin to lipid raft membrane domains analysed by atomic force microscopy.

The Helicobacter pylori vacuolating toxin VacA causes several effects on mammalian cells in vitro, including intracellular vacuolation, formation of pores in the plasma membrane and apoptosis. When added to cells, VacA becomes associated with detergent-resistant membranes, indicating that it binds preferentially to lipid rafts. In the present study, we have used atomic force microscopy to examine directly the association of VacA with lipid domains in supported lipid bilayers. VacA did not bind to lipid bilayers at pH 7.6. In contrast, at pH 4.0, VacA associated with the bilayers in the form of 26-nm oligomeric complexes. VacA bound to bilayers produced from either brain lipids or SM (sphingomyelin) plus cholesterol, each of which lacked detectable lipid domains. Bilayers composed of DOPC (dioleoylphosphatidylcholine), SM and cholesterol contained clearly visible raft-like domains, and VacA preferentially associated with these rafts. VacA bound poorly to raft-like domains in DOPC/SM bilayers, indicating that cholesterol is required for efficient association of VacA with lipid domains. When PS (phosphatidylserine), an anionic phospholipid that does not partition significantly into rafts, was added to the mixture of DOPC, SM and cholesterol, VacA was excluded from the rafts, indicating that it binds more avidly to PS than to the raft components. A typical plasma membrane exhibits pronounced lipid asymmetry, with SM enriched in the outer leaflet and PS in the inner leaflet. Therefore it is probable that the association of VacA with rafts in DOPC/SM/cholesterol bilayers represents a useful model for understanding the interactions of VacA with membranes in vivo.

Bacterial Proteins↗

Human immunoglobulin adsorption investigated by means of quartz crystal microbalance dissipation, atomic force microscopy, surface acoustic wave, and surface plasmon resonance techniques.

Time-resolved adsorption behavior of a human immunoglobin G (hIgG) protein on a hydrophobized gold surface is investigated using multitechniques: quartz crystal microbalance/dissipation (QCM-D) technique; combined surface plasmon resonance (SPR) and Love mode surface acoustic wave (SAW) technique; combined QCM-D and atomic force microscopy (AFM) technique. The adsorbed hIgG forms interfacial structures varying in organization from a submonolayer to a multilayer. An "end-on" IgG orientation in the monolayer film, associated with the surface coverage results, does not corroborate with the effective protein thickness determined from SPR/SAW measurements. This inconsistence is interpreted by a deformation effect induced by conformation change. This conformation change is confirmed by QCM-D measurement. Combined SPR/SAW measurements suggest that the adsorbed protein barely contains water after extended contact with the hydrophobic surface. This limited interfacial hydration also contributed to a continuous conformation change in the adsorbed protein layer. The viscoelastic variation associated with interfacial conformation changes induces about 1.5 times overestimation of the mass uptake in the QCM-D measurements. The merit of combined multitechnique measurements is demonstrated.

Adsorption↗

Analysis by atomic force microscopy of Med8 binding to cis-acting regulatory elements of the SUC2 and HXK2 genes of saccharomyces cerevisiae.

Med8 protein is a regulator that specifically binds to upstream activating sequences (UASs) of SUC2 promoter, to downstream repressing sequences (DRSs) of the HXK2 gene and to the carboxy-terminal domain of the RNA polymerase II. Atomic force microscopy has allowed for direct visualization of Med8 interactions with a 305 bp fragment of SUC2 promoter and with a 676 bp fragment of HXK2 gene, containing respectively the UASs and DRSs regulatory regions. This approach has provided complementary information about the position and the structure of the DNA-protein complexes. Med8 binding to DNA results in total covering of one of the two existing 7 bp motives (consensus, (A/C)(A/G)GAAAT) in the studied DNA fragments. No preference for binding either of the two UASs of SUC2 promoter as well as for the two DRSs of HXK2 gene has been found. We also discuss whether this protein works as dimer or as a monomer.

Carrier Proteins↗

Discrimination of aqueous and aeolian paleoenvironments by atomic force microscopy-- a database for the characterization of martian sediments.

In the search for aqueous habitats on Mars direct proof of (ancient) flowing water is still lacking, although remote sensing has provided indications of young fluvial systems. To demonstrate that such proof can be given, we examined surface marks on recent terrestrial sand grains by atomic force microscopy (AFM) and applied a quantitative three-dimensional analysis that can numerically distinguish between aeolian and aquatic transport mechanisms in sedimentary deposits on Earth. The surfaces of natural quartz grains as well as olivine, feldspar pyroxene, and monazite sands of known origin were imaged, each image yielding a three-dimensional map of the mineral surface. A fully automated analysis of distribution patterns of the structural elements that constitute the grain surfaces shows that wind-transported quartz grains have short linear elements irregularly distributed on the surface. Linear elements on water-transported grains, however, are longer with orientations that reflect the mineral symmetry. Because the surface patterns found on aqueous grains are due to preferential etching, they can be used as diagnostic fingerprints for the existence of past or present aqueous transport systems. We used a cluster analysis of the cross-correlation distance of distribution patterns in the structures of aeolian and aquatic sand grains to build a phenogram that provides a map for the relationship of the various sediments found on earth. The analysis shows that the method is highly significant and that water and wind transport can clearly be differentiated. In particular, feldspar and olivine sands contributed even more to the discrimination than quartz grains, which indicated that the method is promising for its application on future missions to Mars. Assuming that martian aqueous sand grains exhibit similar erosional patterns to mineral grains on Earth, simple AFM experiments on a Mars lander would be capable of proving the activity of flowing water in modern runoff systems and of analyzing the paleoenvironments of Mars.

Exobiology↗

Atomic force microscopy imaging demonstrates that P2X2 receptors are trimers but that P2X6 receptor subunits do not oligomerize.

P2X receptors are cation-selective channels activated by extracellular ATP. The architecture of these receptors is still not completely clear. Here we have addressed this issue by both chemical cross-linking and direct imaging of individual receptors by atomic force microscopy (AFM). Cross-linking of the P2X(2) receptor produced higher order adducts, consistent with the presence of trimers. The mean molecular volume of the receptor determined by AFM (409 nm(3)) also points to a trimeric structure. P2X(2) receptors bearing His(6) epitope tags were incubated with anti-His(6) antibodies, and the resultant complexes were imaged by AFM. For receptors with two bound antibodies, the mean angle between the antibodies was 123 degrees , again indicating that the receptor is a trimer. In contrast, cross-linking of the P2X(6) receptor did not produce higher order adducts, and the mean molecular volume of the receptor was 145 nm(3). We conclude that P2X(2) receptors are trimers, whereas the P2X(6) receptor subunits do not form stable oligomers.

Animals↗

Volume of extracellular polymeric substance coverage of individual Acidithiobacillus ferrooxidans bacterium measured by atomic force microscopy.

The Acidithiobacillus ferrooxidans response to stress associated with the drying process is known to be the production of extracellular polymeric substance (EPS) coverage. Here, samples of A. ferrooxidans suspensions grown in 1.8 pH and 3.0 pH and dried on mica and silicon are shown to form a structure of isolated bacteria. Individual bacteria coverage patterns were imaged by atomic force microscopy (AFM) on hydrophobic (silicon) and hydrophilic (mica) substrates. A comparison of images of covered and uncovered bacteria establish the volume of individual EPS coverage. The EPS production for bacteria on hydrophobic substrates shows a substantial decrease (a factor of 30) in the EPS volume per bacterium when compared with the one on hydrophilic substrates. Shape and volume determination of EPS structures on bacteria as a function of hydrophobicity or hydrophilicity of the substrate may help to determine the functions of EPS on bacterial aggregates.

Acidithiobacillus↗

Preliminary atomic force microscopy study of two-dimensional crystals of lactose permease from Escherichia coli.

Lactose permease (LacY) of Escherichia coli is not only a paradigm for secondary transporters but also for difficulties in two-dimensional (2D) crystallization. In this work we present the progresses achieved in the observation of 2D crystals of wild-type LacY by atomic force microscopy (AFM). Crystals were obtained following reconstitution of LacY in 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) liposomes. Proteolipid sheets (PLSs) 6.4 nm in height were obtained after spreading the samples onto mica. Observations were carried out in liquid medium and in contact mode (CM-AFM). When the crystalline surfaces of the PLSs were imaged regular packing arrangements were observed. The back-Fourier transformation revealed the existence of various orientations mostly consistent with crystals possessing p2 symmetry and unit-cell dimensions: a=13.15 nm, b=16.74 nm, gamma=116 degrees. The characteristics, size, and shape of the repetitive motif could be compatible with dimers of this protein. These preliminary results are compared and discussed with previously reported 2D crystals observed by electron microscopy.

Crystallization↗

An in situ atomic force microscopy study of uric acid crystal growth.

Kidney stones are heterogeneous polycrystalline aggregates that can consist of several different building blocks. A significant number of human stones contain uric acid crystals as a crystalline component, though the molecular-level growth of this important biomaterial has not been previously well-characterized. In the present study, in situ atomic force microscopy (AFM) is used to investigate the real-time growth on the (100) surface of uric acid (UA) single crystals as a function of fundamental solution parameters. Layer-by-layer growth on UA (100) was found to be initiated at screw dislocation sites and to proceed via highly anisotropic rates which depend on the crystallographic direction. The smallest b-steps exhibited minimum heights corresponding to two molecular layers, while fast-moving c-steps more commonly showed monolayer heights. Growth kinetics measured under a range of flow rates, supersaturation levels, and pH values reveal linear trends in the growth kinetics, with faster growth attained in solutions with higher supersaturation and/or pH. The calculated kinetic parameters for UA growth derived from these experiments are in good agreement with the values reported for other crystal systems.

Crystallization↗

Atomic force microscopy study of Escherichia coli lactose permease proteolipid sheets.

Proteolipid sheets (PLSs) obtained using the vesicle fusion technique on a convenient surface are the base to obtain transmembrane protein biosensors. In this preliminary work, we have screened several physicochemical conditions to optimize the visualization of proteolipid sheets formed between different phospholipid matrices and the membrane protein lactose permease (LacP) by atomic force microscopy (AFM). When LacP was reconstituted in 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) liposomes, the proteolipid sheets were densely packed with an upper layer that protruded from a background layer. Several lipid protein molar ratios (LPR) were screened. High resolution analysis of the upper layer revealed a quasi-crystalline arrangement formed by small entities that could be attributed to the protein. The approach described here may be suitable for the rational design of biosensors based in other transmembrane proteins.

Adsorption↗