Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ZIRCONIUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Relative biological effectiveness enhancement of a 125I brachytherapy seed with characteristic x rays from its constitutive materials.

The isotopes used for permanent prostate implants, 125I and 103Pd, provide about equivalent tumor control. The purpose of this study is to investigate how characteristic x rays may be used to raise the relative biological effectiveness (RBE) of an iodine seed at short distances to increase the differential effect between tumor and healthy tissue. Within the theoretical framework of microdosimetry, the GEANT4 Monte Carlo simulation toolkit has been used to calculate the RBE of experimental seed designs in which shell and core dimensions and composition were varied independently. A new seed model was also simulated based on the best results obtained. The RBE could be enhanced by increasing the shell thickness and for the range considered, optimum results were obtained by using gradually lower atomic number elements. For a practical 50-60 microm shell, molybdenum is the material of choice. The core diameter has little influence on RBE, but maximum effectiveness is obtained with yttrium or zirconium. These results were put together to design a Mo-shell and Y-core seed for which the RBE enhancement was at least 5-7% (close to the source), which is higher than palladium. This enhanced RBE combined with the longer half-life of iodine could mean comparable tumor control and better protection to organs at risk than with current seeds. The RBE dependence on distance is an interesting feature that could benefit other applications such as ocular melanoma or coronary brachytherapy where a highly localized dose distribution is desired.

Brachytherapy↗

Two thermal methods to measure the energy fluence of a brief exposure of diagnostic x rays.

This paper describes two simple thermal methods for measuring the energy fluence in J/cm2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Energy Transfer↗

Pressure-induced amorphization and negative thermal expansion in ZrW2O8

It has recently been shown that zirconium tungstate (ZrW2O8) exhibits isotropic negative thermal expansion over its entire temperature range of stability. This rather unusual behavior makes this compound particularly suitable for testing model predictions of a connection between negative thermal expansion and pressure-induced amorphization. High-pressure x-ray diffraction and Raman scattering experiments showed that ZrW2O8 becomes progressively amorphous from 1.5 to 3.5 gigapascals. The amorphous phase was retained after pressure release, but the original crystalline phase returned after annealing at 923 kelvin. The results indicate a general trend between negative thermal expansion and pressure-induced amorphization in highly flexible framework structures.

Journal Article↗

Rapid lysis technique for mycobacterial species.

The lysis of mycobacterial cells typically has been difficult and time-consuming. We report a method for the physical rupture of Mycobacterium paratuberculosis and several other members of the family Mycobacteriaceae using a Mini-Beadbeater cell disrupter (Biospec Products; Bartlesville, Okla.) and zirconium beads, a process which yields DNA and RNA of high molecular weight and in greater quantity than that obtained by rupture in a Ribi pressure cell.

Animals↗

Detection of Mycobacterium tuberculosis directly from spiked human sputum by Q-beta replicase-amplified assay.

We report on a rapid, sensitive, Q-Beta replicase-amplified nucleic acid hybridization assay for the detection of Mycobacterium tuberculosis directly from spiked human sputum. Specimens were processed by either an N-acetyl-L-cysteine-NaOH or a 2% NaOH digestion-decontamination method and then washed to neutralize the pH of the cell pellet. The washed sputum pellets were heated at 100 degrees C to inactivate the M. tuberculosis organisms. The heat-inactivated samples were mechanically lysed at 5,000 rpm for 6 min in the GENE-TRAK Sample Processing Instrument in the presence of zirconium oxide beads and a buffer containing guanidine thiocyanate. The released nucleic acid was subjected to the GENE-TRAK Q-Beta replicase-amplified, dual-capture assay. The assay sensitivity was 10(3) purified rRNA targets or 1 CFU of M. tuberculosis spiked into M. tuberculosis-negative human sputum. There was a low level of noise because of the limitations of performing a signal amplification assay in an open system. High levels of other mycobacterial rRNA (approximately 10(7) organisms), including rRNAs of Mycobacterium avium and Mycobacterium gordonae, did not interfere with the sensitivity of the assay.

Bacteriological Techniques↗

beta-Lactamase inhibitors and the inducibility of the beta-lactamase of Mycobacterium tuberculosis.

Ten clinical isolates and the type strain (H37Rv) of Mycobacterium tuberculosis were shown to produce an intracellular beta-lactamase. Crude enzyme preparations were extracted from acetone cell powders by grinding with zirconium beads in 0.133 M glycine with 1.0% Triton X-100. The enzymes had identical patterns on isoelectric focusing, with two major bands at isoelectric points of 4.9 and 5.1. The beta-lactamase was highly susceptible to the new beta-lactamase inhibitor BRL 42715, with an I50 of 0.0001 microgram/ml. The enzyme was also susceptible to clavulanic acid with an I50 (0.05 microgram/ml), which was similar to the value for the common bacterial beta-lactamase TEM-1 (0.01 microgram/ml). The latter result is consistent with previous MIC studies with M. tuberculosis, which have shown synergy between clavulanic acid and amoxicillin. BRL 42715 and clavulanic acid were more active than sulbactam, tazobactam, and cloxacillin. These studies support the potential value of penicillin/clavulanic acid and penicillin/BRL 42715 combinations in the treatment of tuberculosis.

Dose-Response Relationship, Drug↗

Endotoxin up-regulates interleukin-18: potential role for gram-negative colonization in sarcoidosis.

RATIONALE AND OBJECTIVES: Sarcoidosis is a granulomatous disease of unknown etiology characterized by a helper T-cell type 1-mediated process. Previously we demonstrated a role for interleukin-18 in sarcoidosis. Here we examine the regulation of interleukin-18 in this condition. METHODS: Cytokine levels in sarcoid epithelial lining fluid were measured by ELISA. We examined interleukin-18 promoter activity and mRNA and protein levels in the epithelial lining fluid of individuals with active sarcoidosis, and of individuals recovered from sarcoidosis, in response to purified protein derivative of Mycobacterium tuberculosis, beryllium sulfate, zirconium sulfate, aluminum sulfate, and lipopolysaccharide. Endotoxin levels in the epithelial lining fluid of individuals with sarcoidosis, individuals recovered from sarcoidosis, and control subjects were assessed by Limulus amebocyte lysate analysis. Allele-specific polymerase chain reaction was used to genotype 94 patients with sarcoidosis and 97 control subjects for the interleukin-18 -607(A/C) polymorphism. Species-specific polymerase chain reaction identified bacterial DNA in fluid samples. RESULTS: Epithelial lining fluid from active sarcoids contained elevated levels of interleukin-18, interferon-gamma, and interleukin-12 compared with recovered patients and also contained significantly higher levels of endotoxin. Depletion of endotoxin from this epithelial lining fluid reduced its effect on the human interleukin-18 promoter in vitro. There was a higher frequency of the -607C allele and -607(C/C) genotype in the sarcoidosis population compared with control subjects; however, this was not associated with a functional response to endotoxin treatment. Finally, bacterial 16S rRNA from Haemophilus influenzae and Moraxella catarrhalis was detected in sarcoid fluid samples. CONCLUSIONS: The pathogenesis of sarcoidosis is propagated through the actions of a helper T-cell type 1-driven response. This study shows that gram-negative bacteria may contribute to this effect by upregulating interleukin-18 expression.

Adult↗

Enamel silicon and fluoride relationships demonstrating a surface silicon effect that facilitates fluoride uptake.

This study indicated that a clear relationship exists between silicon and fluoride. We have also demonstrated a probable surface enamel silicon effect that increases fluoride uptake. The complex set of relationships described in the surface chemistry of calcium, tin, and zirconium with fluoride, hydroxide, phosphate, and other surface-occurring ions need not be considered to confuse the specific silicon-fluoride relationship presented here because in this computation we are relating the changes in the silicon and fluoride ion values only. We have, however, considered the thermodynamics of such reactions and intend to elaborate on it in a later publication. We are aware of the small depth of fluoride penetration into enamel after topical treatment Health Foundation, Research Unit at the National Bureau of Standards, Washington, DC 20034, USA.

Composite Resins↗

Water sorption and filler characteristics of composites for use in posterior teeth.

The purpose of this investigation was to determine the water sorption and solubility, as well as the filler composition and extent of chemical degradation in water, of eight different posterior composites. With one exception, the materials with the largest quantity of fillers had the least water sorption and solubility after three months in water at 37 degrees C. The emission spectroscopy results showed that silicon was the major element in all the fillers except one, which had both silicon and strontium as major elements. Other components registered in quantities of 5-10 wt-% were barium, aluminum, zinc, and zirconium. The leaching of inorganic ions into water from the fillers varied depending on filler composition and filler treatment.

Absorption↗

Materials characteristics of uncoated/ceramic-coated implant materials.

In this paper, the biocompatibility of dental implant materials is discussed in the context of both the mechanical characteristics of the materials and the type of surface presented to the surrounding tissues. The proper functioning of the implant depends on whether it possesses the strength necessary to withstand loading within the expected range, with other properties such as elongation being of importance in some instances. A suitable modulus of elasticity may be of major importance in situations when optimum load transmission from the implant into the surrounding bone is key to the successful functioning of the device. Dental implants present a wide range of surfaces to the surrounding tissues based on surface composition, texture, charge energy, and cleanliness (sterility). Metallic implants are characterized by protective oxide layers, but ion release is still common with these materials, and is a function of passivation state, composition, and corrosion potential. An effective surface treatment for titanium appears to be passivation or anodization in a suitable solution prior to implantation. Inert ceramic surfaces exhibit minimal ion release, but are similar to metals in that they do not form a high energy bond to the surrounding bone. Some of the newly developed dental implant alloys such as titanium alloys, which contain zirconium and niobium, and high-strength ceramics such as zirconia may offer some advantages (such as lower modulus of elasticity) over the conventional materials. Calcium phosphate ceramic coatings are commonly used to convert metallic surfaces into a more bioactive state and typically cause faster bone apposition. There is a wide range of ceramic coatings containing calcium and phosphorus, with the primary difference in many of these materials being in the rate of ion release. Although their long-term success rate is unknown, the calcium phosphate surfaces seem to have a higher potential for attachment of osteoinductive agents than do uncoated titanium and other more inert implant materials.

Biocompatible Materials↗

Some failure modes of four clinical bone cements.

The fracture or failure behaviours of four commercial acrylic-based bone cements have been examined in tensile, bending and compression modes, and their mechanical properties are reviewed. It was found that Palacos R-40 bone cement had high radiopaque agent concentration, with high surface hardness. It exhibited a much lower bending strength and bending modulus compared with the other three bone cements (CMW1, CMW2000 and Simplex P). The textures of tensile fracture surfaces produced were similar for the four bone cements studied. The fracture surface was fragmented by crevices, which developed through the matrix and around large undissolved polymethylmethacrylate (PMMA) beads. Three bands with different features existed on the bending fracture surfaces, with an abrupt transition between them. It appears that the agglomerates of zirconium dioxide particles are implicated in Palacos R-40 bone cement fracture surface. The examination of compressive failed specimens revealed that a 'yielded crack band' existed across the transverse section. Plastic deformation resulted in the PMMA beads being squashed in the longitudinal direction and dilated in the transverse direction.

Biomechanical Phenomena↗

A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.

After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By means of the novel test device, cemented hip stems with different designs, surface topographies and material compositions using various bone cements could be investigated. Before testing, the cemented stems were disconnected from the cement mantle to simulate the situation of stem loosening (debonding). Subsequently, constant radial contact pressures were applied on to the stem surface by a force-controlled hydraulic cylinder. Oscillating micromotions of the stem (+/- 250 microm; 3 x 10(6)cycles; 5 Hz) were carried out at the cement interface initiating the wear process. The usability of the method was demonstrated by testing geometrically identical Ti-6A1-7Nb and Co-28Cr-6Mo hip stems (n= 12) with definite rough and smooth surfaces, combined with commercially available bone cement containing zirconium oxide particles. Under identical frictional conditions with the rough shot-blasted stems, clearly more wear particles were generated than with the smooth stems, whereas the material composition of the hip stems had less impact on the wear behaviour.

Biocompatible Materials↗

Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.

In the course of 30 years of hip endoprosthetics, a number of material combinations for the cups and balls of total hip prostheses have proven successful under clinical conditions. Favourably priced hip prostheses with polyethylene cups and metal balls are available for older patients with a moderate range of activity. Polyethylene wear of 100-300 microns/year is to be expected with these models. Ceramic balls (aluminium oxide for diameters 32 and 28 mm and zirconium oxide for 22 mm) paired with polyethylene cups are recommended for patients with a life expectancy of 10 to 20 years, because the expected polyethylene wear rate with this material combination is only 50-150 microns/year. In other words, the life cycle of the polyethylene cup is doubled, when it is paired with a ceramic ball. A similar polyethylene wear rate is also to be expected with oxygen-deep-hardened TiAlNb metal balls, which are currently the subject of a clinical field study. Last but not least, CoCrMoC metal-metal and Al2O3 ceramic ceramic pairings, which have the lowest wear rate of 2-20 microns/year, are available for highly active patients with a life expectancy of more than 20 years. As far as the cup-ball pairing is concerned and under the current pressure of costs, the surgeon should be able to select the optimum hip prosthesis model for every patient from these three categories.

Alloys↗

Optical characteristics of the compound PLZT.

We present a summary of measured characteristics of lanthanum-doped lead zirconium titanate (PLZT) compound in its mechanical housing. It is expected that the PLZT device will be used as the main component in an ultrafast electro-optic switch. We have performed several experiments to measure and calculate the following characteristics: optical power transmission, thermodynamic effects, switching speed, and dc drift phenomenon.

Journal Article↗

Determination of the optical constants (n and k) of inhomogeneous thin films with linear index profiles.

A new method for the determination of optical constants of absorbing inhomogeneous thin films is proposed. It requires measurements at normal incidence of the reflectance and transmittance of the film. In an inhomogeneous thin film, the optical constants vary along the thickness of the film. It has been reported in the literature that only the spatial integral value of the absorption index needs to be considered if its value is small. Therefore, in the proposed method, the mean value of the absorption index was used. The validity of this assumption was tested. On the other hand, the variation in the refractive index along the thickness of the film was taken into account. The method is discussed along with the nature of the solutions obtained and the effects of various parameters and assumptions. The method is applied successfully to inhomogeneous thin films of zirconium oxide.

Journal Article↗

[TNF-alpha secretion by human macrophage-like cells in response to wear particles and its modification by drugs].

UNLABELLED: Tumour necrosis factor (TNF) is considered to be the initiator protein of particle disease leading to aseptic loosening of endoprostheses. The aim of the present study was to investigate the TNF response of the macrophage-like cells (MLC) to the periprosthetic particles typically found during revision surgery. For this purpose, particles of polyethylene (PE), pure titanium (Ti), chromium (Cr), cobalt (Co), alumina ceramic (Al2O3) and zirconium dioxide (ZrO2) were used. Additionally, the therapeutic effect of non-steroidal and steroidal drugs, biphosphonates and pentoxyfylline on PE particles was investigated with the aim of differentiating drugs with, from those without, a positive effect on aseptic loosening. METHOD: In an established macrophage model (Rader et al. 1999), THP1 cells (human monocytic cell line) were differentiated over a period of five days in the presence of vitamin D3 and GM-CSF in macrophage-like cells (MLC). To obtain a TNF profile of the different materials, 10(6) MLC were incubated with each of a range of different particle concentrations. For drug testing purposes 80 x 10(8) PE particles, which evoked a maximum TNF response, were applied together with increasing drug concentrations in the same manner. The supernatant was then investigated for TNF secretion using ELISA. RESULTS: It was found that the greatest TNF response was provoked by Co and PE particles, and was 25 and 23 times as high, respectively, in comparison with control. The smallest TNF secretion was seen with Al2O3 (4 x control) and ZrO2 (5 x control). At the recommended dose, non-steroidal anti-inflammatory drugs (NSAIDs) produced no decrease in TNF secretion. The biphosphonates, etidronate and ibendronate significantly reduced the TNF response of the PE-stimulated macrophages (by 1/7 and 1/5, respectively). Therapeutic doses of pentoxyfylline also led to a decrease of 1/5 in maximum TNF release. CONCLUSION: Ceramic articulating surfaces are superior to metal/metal or PE/PE matings in terms of the biological effects of their wear particles. At therapeutic doses, NSAIDs have no beneficial effect on the process of aseptic loosening. Certain biphosphonates and pentoxyfylline have a positive effect on aseptic loosening.

Biocompatible Materials↗

[Identification of wear particles of joint prostheses in tissues using laser microprobe mass analysis (LAMMA)].

The definite identification of wear particles from joint prostheses is of great importance for the development of joint replacement, as the type and quantity of different wear particles gives information on the wear resistance of implant materials. From the types of prostheses nowadays in use polyethylene wear of the sockets, bone cement wear, metallic and ceramic wear can be generated. Whereas polyethylene wear can be easily identified by its bright luminescence in polarized light and its characteristic configuration, the distinction of the small granular wear particles of the bone cement, metal and ceramic by light microscope is difficult. The laser microprobe mass analysis (LAMMA) is a method, which allows the analysis of single light microscopically detectable wear particles in tissues. Not only contrast medium particles of the bone cements (zirconium oxide or barium sulfate) but also metallic and aluminum oxide particles could be definitely identified within the pseudocapsules as well as in regional lymph nodes by LAMMA-analysis, whereby the bone cement wear predominated. In addition, the distinction between organic substances (as blood degradation products), which may appear similar to wear particles in configuration and colour, and the foreign material is also possible with this method.

Bone Cements↗

[Occupational diseases caused by exposure to sensitizing metals].

Diseases caused by occupational exposure to sensitizing metals including platinum (Pt), rhodium (Rh), nickel (Ni), chromium (Cr), cobalt (Co), gold (Au), mercury (Hg), zirconium (Zr) and beryllium (Be) are reviewed. Allergic reactions induced by the metals are described according to the classification by Coombs and Gell. Metals with unproven sensitizing potential are not discussed if reports on these are either very rare or devoid of convincing evidence for allergic involvement. The sensitizing metals are haptens which are not themselves able to act as antigens. There is evidence that combination of the metals with circulating or tissue protein gives rise to new antigens. An alternative hypothesis is that these metals interfere with the antigen recognition step of the immune response. Immunomodulatory effects or immunotoxicity of the metals may be also involved in metal-induced hypersensitivity. Occupational exposure to Pt, Rh, Ni, Cr, and Co causes allergic asthma via type I allergic reaction in which serum from affected individuals shows specific IgE antibodies against mental-human serum albumin conjugates. Some rheumatoid arthritis patients treated with gold salt therapy develop glomerulonephritis, thrombocytopenia, or agranulocytosis, which arise from type II and/or type III allergic reactions. Occupational exposure to mercury causes glomerulonephritis in which involvement of type III reaction is suggested. Type IV hypersensitivity reaction of the skin also takes place following exposure to the metals: allergic contact dermatitis is evoked by exposure to Ni, Cr, Co, Rh, and Hg; cutaneous granuloma is formed by contact with Zr and Be. Be is also a sensitizer of the lungs, resulting in granulomatous disease. Diagnosis of metal-induced allergic diseases is made on the basis of allergological tests with metal antigens including skin tests, radioallergosorbent test for specific antibody, lymphocyte transformation test, macrophage migration inhibition test, and provocation test. Atopy is a predisposing factor and smoking is a risk factor for developing metal-induced asthma. Evidence for genetic factors in the development of metal contact dermatitis is conflicting, although animal models implicate genetic factors in skin sensitization with some metals and respiratory sensitization with Be. Skin irritation, forearm injury, complication with atopic dermatitis and concomitant sensitization to other agents are determinants for prognosis of the dermatitis. Epidemiological reports of occupational diseases from allergic reactions to metals in industries are reviewed with respect to prevalence and allergic manifestations. There is a report on a clinical trial of hyposensitization with Pt in a platinum asthma patient. Predictive methods for evaluating sensitization potential of metals have been developed and new methods, which quantify potential more objectively, are sought.

Allergens↗