Optimization of radiographic technique for chest radiography.

Over 1500 patients undergoing chest radiography in the West Midlands have been monitored for entrance surface doses using lithium borate thermoluminescent dosemeters. In total 63 X-ray tubes were monitored from 30 hospital departments. The mean patient entrance surface dose is 0.15 mGy, and the 75th percentile entrance surface dose is 0.18 mGy. A reference level of 0.18 mGy has been recommended for PA chest radiography in the West Midlands. Image quality has been assessed on patient radiographs. Departmental radiologists were responsible for assessing radiographs taken within their hospital. Independent analysis was performed by a control radiologist. Film-screen processor sensitivity has been assessed on 48 film-screen processor combinations. Significant differences were observed between the nominally quoted sensitivities and the measured sensitivities. Only 26% of systems produced measured sensitivities within 10% of the nominal values. A four variable regression model, explaining 78% of the variance, provided the best description for the variation in patient dose. These variables were actual sensitivity, applied potential, generator waveform and radiographic quality. Four recommendations have been made to lower patient doses; these are: (1) an increase in applied potential to a minimum of 90 kVp; (2) a film-screen sensitivity of 400; (3) optimization of processor performance and (4) regular radiological audits to reduce repeat rates to a level of 5%. If all of these recommendations are followed, an estimated overall entrance surface dose saving of 53% would result. Changing the applied potential alone will see the variation in the mean entrance surface dose from non-gridded systems reduce from a factor of 4 to a factor of 2.

Humans↗

The role of plain radiography in the management of suspected orbital blow-out fractures.

We reviewed the indications for radiography and its impact on management in 100 consecutive patients referred to the Radiology Department from the Accident and Emergency Department of a large eye hospital in order to assess the utility of orbital plain radiographs in patients suspected of having blow-out fractures. We assessed whether administration of antibiotics or referral for surgical or orthoptic treatment was influenced by clinical features, radiographic findings or both. Ophthalmologists interpreting the radiographs appeared to be guided by the presence or absence of physical signs. No patient in whom they overlooked a fracture which was not evident clinically was subsequently referred for surgery. All patients who did have surgery for complications of a blow-out fracture underwent pre-operative computed tomography. Neither referral for orthoptic treatment nor administration of systemic antibiotics was consistently influenced by the presence or absence of a fracture. Given these findings, and the observation that the decision to operate was guided exclusively by clinical rather than radiological criteria, we recommend that only patients with well-defined indications for surgery (enophthalmos of more than 2 mm at any time within the first 6 weeks following the injury, and/or diplopia in the primary and/or downgaze reading positions not showing evidence of resolving within 2 weeks of the injury) should undergo radiography.

Adolescent↗

Does 100 mm photofluorography always have a dose advantage over conventional film-screen radiography in barium meals?

It is generally held that 100 mm photofluorography has a significant dose saving advantage over conventional radiography. The dose area product (DAP) data for the two formats were available for study in consecutive patients undergoing barium meal examination. There was no significant difference in DAP readings between the two formats. Conventional radiographs expose a 40% greater area than the 100 mm format, probably accounting for the lower mean DAP value of photofluorography. The mean DAP for whole examinations was 26.1 Gy cm2 for photofluorography, and 30.5 Gy cm2 for conventional radiography. These are both above the third quartile of national reference dose levels. There is little apparent difference in the doses incurred by patients between the two formats in respect of the working practice of the department. Barium meals will therefore continue to be recorded on both formats.

Barium Sulfate↗

"Anode heel effect" on patient dose in lumbar spine radiography.

Appropriate use of the "anode heel effect" of the output beam from an X-ray tube can reduce the effective dose to patients in some common radiological examinations. We investigated the variation in radiation intensity across the X-ray beam caused by the anode heel effect, and quantified the difference in absorbed dose to critical organs resulting from lumbar spine X-ray projections carried out with the two possible orientations of the patient along the tube axis (cathode to anode). A Rando phantom and some high sensitivity thermoluminescent dosemeters (TLDs) (LiF:Mg,Cu,P) were used. With the tube axis horizontal, radiation intensity profiles, parallel and perpendicular to the axis, were measured. Lumbar spine radiographs were recorded using the Rando phantom in the standard anteroposterior (AP) and lateral projections. TLD pellets were used to measure the absorbed radiation dose at various sites corresponding to critical organ tissues (ovaries, testes, breasts, thyroid and lens). Each set of projections was recorded in two phantom orientations, first with the phantom head placed towards the cathode end of the X-ray tube, and then in the reverse direction. From the radiation intensity profile of the incident X-ray beam, the "cathode end" to "anode end" air dose ratio was found to be 1.8. In lumbar spine radiography, with the phantom head placed towards the anode end of the X-ray tube, the ovaries and testes received an average dose 17% and 12% higher, respectively, in the lateral projection, and 16% and 27% higher, respectively, in the AP projection, than those obtained in the reverse "patient" orientation. These results indicate that patients (particularly females) should always be positioned with the head placed towards the cathode end of the X-ray tube for lumbar spine radiography to achieve significant dose reductions.

Breast↗

A phantom for dose-image quality optimization in chest radiography.

Optimization in chest radiography requires evaluation of patient dose and image quality. This study is aimed at proposing a simple geometrical phantom that realistically simulates the important anatomical regions of the thorax. For this purpose, the standard LucAl chest phantom is modified by adding an "anthropomorphic" insert and image quality test plate. Different test objects are arranged on the plate in three important anatomical areas; lung, cardiac, and subdiaphragmal regions. The aim is to simultaneously find two types of image quality index, objective and subjective, which can be used to compare different images in order to select the better image. Two objective indices are proposed, areal contrast index DeltaC(a) and scatter fraction P(s) and two subjectively estimated, a low contrast visualization index P(low) and a high contrast visualization index P(high). To demonstrate the potential of this phantom method it was applied to an X-ray unit to find the optical film density that ensures optimal visualization in different anatomical areas. It was found for the X-ray system under investigation that the automatic exposure control could be set to produce an optical density of about 1.8 in the lung field. The reported method is easily implemented in any clinical situation where optimization of chest radiography is needed.

Humans↗

Determination of projections for subtraction radiography based on image similarity measurements.

The reliability of subtraction radiography strongly depends on the ability to obtain two identical projections. Generally this is done by connecting mechanically the X-ray source, the patient and the film. However, this method has certain disadvantages, which restrict its use to small groups of patients in other than routine clinical situations. A computer-aided radiographic imaging technique (tomosynthesis) brings the reconstruction of arbitrary projections within reach. This technique can be used to reconstruct the projection required for a proper subtraction. However, in order to do so, the coordinates of the source position of one projection, relative to the source positions of the set of projections used for fomosynthesis, has to be determined. A method is described based on similarity measurements, in pairs of images (expressed in the form of standard deviations) to achieve this. The coordinates of the unknown source position could be determined with an average accuracy of 0.513 degrees (range 0.000-1.289 degrees), which is well within the range of deviations tolerable for the clinical application of subtraction radiography.

Radiography, Dental↗

A comparison of panoramic radiography with computed tomography in the planning of implant surgery.

The accuracy of panoramic radiography and computed tomography (CT) in the evaluation of depth of the mandible at recipient implant sites was compared by measuring the distance between the edentulous bony crest and the superior border of the inferior alveolar canal in a group of ten patients. Distortion was calculated using the metal ball technique for the panoramic radiographs and the computer scale for the CT scans. The precise distance between the bony crest and inferior alveolar canal was determined from postoperative radiographs from the known length of the implants. It was found that although CT scans are more precise, panoramic radiography is sufficiently accurate for routine clinical purposes. CT scans have, however, an additional advantage in presurgical planning, since they reveal the horizontal dimension and shape of the mandible, and the topography and buccolingual location of the inferior alveolar canal.

Alveolar Process↗

Comprehensive oral X-ray diagnosis: Scanora multimodal radiography. A preliminary description.

Scanora (Soredex, Orion Corporation, Helsinki, Finland) is a multimodal radiography system which utilizes the principles of narrow beam radiography and spiral tomography. The system includes an integrated multifunction X-ray unit, a coordinate system for object localization and a wide selection of dental and maxillofacial imaging problems. All imaging procedures are computer controlled and executed automatically. Clinical experience and preliminary results show that the multimodal imaging system has great potential in the detection of pathological conditions of the maxillofacial region.

Humans↗

1992 assessment of radiation risk from dental radiography.

Recent studies suggest that the lifetime cancer risks from exposure to low levels of ionizing radiation may be greater than previously estimated. This review first summarizes the findings of these studies as they pertain to dental radiology, then uses their concepts in combination with dosimetry from the dental literature to estimate the radiation risk from dental radiology. Estimation of risk from groups of exposed individuals requires use of mathematical models that fit the epidemiological data. The ICRP estimates that a single brief whole-body exposure of 1 Gy to 10,000 people results in about 500 additional cancer deaths over the lifetime of the exposed individuals, assuming a dose rate effectiveness factor of 2 for cancers other than leukaemia. Leukaemias are seen as a wave from 5 to 30 years following exposure. Cancers other than leukaemia typically start to appear about 10 years following exposure and remain in excess for as long as most exposed populations are followed, presumably for the lifetime of the exposed individuals. The gonadal dose is so small from dental radiography that the risk of heritable defects is negligible in comparison with the somatic risk. The dental literature contains several studies reporting sufficient dosimetric data for radiosensitive sites in the head and neck to allow estimation of the risk of fatal cancers from intra-oral and panoramic radiography. The highest estimated risks (using the ICRP data) are for leukaemia (bone marrow), thyroid and bone surface cancer. The total risk is estimated to be 2.5 fatal malignancies per 10(6) full-mouth examinations made with D-speed film and round collimation.(ABSTRACT TRUNCATED AT 250 WORDS)

Abnormalities, Radiation-Induced↗

An anthropomorphic phantom for periodontal radiography.

OBJECTIVE: To construct an anthropomorphic phantom for periodontal radiography. METHODS: The phantom material for the spongiosa was produced by melting polyethylene with calcium hydroxyapatite. Compact bone and teeth were simulated by mixing silicone rubber with calcium hydroxyapatite and calcium carbonate respectively. RESULTS: Radiographs of the phantom show nearly all the structures relevant for periodontal radiography. Measurements of X-ray attenuation and optical density correspond to those of the human mandible. Any defect in the periodontal bone can be reproduced. CONCLUSION: The new phantom will be useful for research and education.

Alveolar Bone Loss↗

Estimation of single-root surface area from true thickness data and from thickness derived from digital dental radiography.

OBJECTIVES: The prognosis of a tooth affected by periodontitis may depend on the amount of bone remaining around the root surface. The aim of this study was to find how the surface area of a single root is related to the true thickness data and the calculated thickness data from digital dental radiographs. METHODS: Eight extracted single-root teeth were digitized three-dimensionally for direct surface area measurement. Meanwhile, they were also exposed to a digital dental X-ray system. The true thickness of the tooth root was measured. The estimated circumference data were calculated from both the measured thickness and the thickness estimated from the digital image and then measured and estimated circumferences were compared. RESULTS: (1) The largest circumference difference mean for measured thickness and for estimated thickness was -4.94% (+/-0.07%) and 23.02% (+/-1.12%) respectively. (2) The largest 95% confidence interval for difference means for measured thickness and for estimated thickness was (-2.82%, -1.87%) and (-5.42%, 2.22%), respectively. CONCLUSIONS: When the thickness data are available, the surface area of a single-root tooth can be estimated to an error of less than 5%. Theoretically, the root thickness can be derived from the projected radiological image of the tooth. However, the error of estimated circumference from digital dental radiography may be over 20%. This error can be minimized if the estimated thickness from digital dental radiography can be made more accurate.

Absorptiometry, Photon↗

A precise receptor-positioning device for subtraction radiography, based on cross-arch stabilization.

OBJECTIVES: To devise and test for reproducibility a new patient-beam alignment device for subtraction radiography. METHODS: A rigid, cross-arch bar was used with bite-registration material. A modified Rinn XCP rod and ring were firmly attached to the bar and were placed in contact with the X-ray cone. The receptor was held by a slot in the bar. Duplicate sets (n=8 pairs) of digital radiographs were made with a modified, calibrated DenOptix photostimulable phosphor system. Image pairs were registered and compared for geometrical and intensity errors by means of quantitative subtraction radiography. The reproducibility of patient-beam alignment for each pair was determined by measuring spatial errors at alveolar crest edges and by comparing magnifications. Intensity errors measured at two predetermined regions of alveolar bone were used to estimate corresponding bone-mass errors. RESULTS: Misalignment at the alveolar crest was generally <1 pixel (0.085 mm), and everywhere < or =0.25 mm. The magnification was constant within a relative standard deviation of 0.13% (n=8). Trabecular features were generally invisible or barely visible in subtraction images. The standard deviation of intensity errors was 1.07% (n=16). This corresponds to a change in bone mass of approximately 2% or less. CONCLUSION: The device has potential for clinical population studies in which the goal is to detect small changes in bone mass and alveolar-crest height. It is convenient to use and comfortable for patients. Because of the cross-arch design, patient-beam alignment is expected to be relatively insensitive to bite-registration errors, tooth movement, and tooth loss.

Alveolar Process↗

Scatter radiation in cephalometric radiography: the effects of grid and collimation.

OBJECTIVES: To measure the scatter fraction in cephalometric radiography with and without a grid and to estimate the patient's dose reduction by using a specially fabricated collimator without a grid. METHODS: A 16 cm thick water-equivalent phantom was used to measure the scatter fraction. The projection geometry was the same as our conventional one, i.e. the distance from the X-ray source to the centre of the phantom was 200 cm. A photostimulable phosphor plate was used as an X-ray sensor and was 20 cm from the centre of the phantom. The measurements were performed in four combinations: with an antiscatter grid in place, with a specially fabricated collimator in place, with neither in place, and with both in place. The images of a human dried skull were obtained by using the above parameters and were subjectively assessed for a visibility of several reference points. RESULT: The scatter fraction in the regularly collimated geometry with the antiscatter grid in place was 0.35 for a relative exposure of 1. With the antiscatter grid removed, the scatter fraction increased to 0.68, but the relative exposure was reduced to 0.3. With a special collimator, the scatter fraction was reduced to some extent in all instances, but the exposure was reduced to 0.45. The visibility of the reference points was acceptable in all conditions. CONCLUSION: In cephalometric radiography, removal of the antiscatter grid yields a significant reduction in exposure with no significant loss of information.

Cephalometry↗

A randomized double blinded study to assess the efficacy of a laser-guided collimator on dental radiography training.

OBJECTIVES: To assess the effect of a laser-guided collimator in intraoral radiography training. METHODS: A custom-made collimator with four red laser diodes on each corner on the rim of an aluminium alloy cubic housing was fabricated. The laser used low power diodes, which are classified as laser-safe by the United States Food and Drug Administration (FDA). When activated, the effective dimensions of the laser beams were 4 cm x 4.5 cm. Eighteen dental hygiene students were randomized into test and control groups. The Laser group used a rectangular collimator with the laser device, while the Non-laser group used a conventional rectangular collimator. Each group attended nine intraoral radiography training sessions. All radiographs were assessed and were classified into three categories: Excellent, Acceptable and Repeat, by a masked academic staff member. Reasons for repeats were marked. Statistical comparisons between the two groups were made. RESULTS: A total of 2334 radiographs were made. Conecut was more common on bitewings than periapicals. The Laser group produced fewer conecuts than the Non-laser group. The Laser group produced more excellent radiographs with fewer repeats than the Non-laser group, but there was not a significant difference. CONCLUSIONS: The laser-guided collimator helped the students to produce fewer repeats in a shorter period of time. It was an effective training aid.

Dental Hygienists↗

The diagnosis and follow-up of pediatric sinusitis: Water's view radiography versus ultrasonography.

Water's view plain film radiography was compared with ultrasonography in the diagnosis and follow-up of acute maxillary sinusitis in 85 children (170 sinuses). At the first visit, the concordance of the two modalities was 91%, but 20 days later, when the symptoms and signs had disappeared, it was only 76%. At the latter date, the concordance between radiography and clinical findings was 71% and between sonography and clinical findings, 93%. The two modalities studied appear to be equally useful in the initial diagnosis of acute maxillary sinusitis. The loss of back-wall echo correlates well with symptomatic improvement of acute sinusitis. Sonography is also nonionizing and inexpensive, and the examination is simple to repeat.

Child↗

The effects of vagotomy on the abomasum in calves: radiography and protein gene product 9.5 immunohistochemistry.

Abomasal disorders of calves with total vagotomy, operated on at 1 week old, were investigated with radiography and protein gene product (PGP) 9.5 immunohistochemistry. Radiographic findings indicated abomasal atony with dilatation in all calves 2 weeks after vagotomy, while 4 weeks after vagotomy abomasal dilatation was detected in 2 calves and another 2 calves showed dilatation and impaction. The densities of PGP 9.5-immunoreactive nerves in the tunica muscularis decreased significantly in the corpus region of the greater curvature 2 weeks after vagotomy and in the pyloric region of the lesser curvature 4 weeks after vagotomy, and it was at its lowest 4 weeks after vagotomy in all regions examined. In conclusion, abomasal dilatation and/or impaction in vagotomized calves confirmed by radiography were related with a decreased frequency of nerves in the tunica muscularis of the abomasum.

Abomasum↗

Analytical radiography of club feet.

A radiographic method is described for making the diagnosis of talo-navicular subluxation before ossification of the navicular bone occurs. Seven basic combinations of deformities are thought to occur in the club foot. Radiography before operation enables the surgeon to determine which of these combinations exists in a particular foot, and radiography during operation enables him to determine wheter or not all the existing deformities have been corrected, and therefore whether or not the operation must be extended.

Child↗

Development of the ball-and-socket ankle as assessed by radiography and arthrography. A long-term follow-up report.

We studied the development of ball-and-socket deformity of the ankle by arthrography and radiography in 14 ankles of ten patients with congenital longitudinal deficiency of the fibula accompanied by various anomalies. The mean follow-up was for 18 years 10 months. In three ankles in infants less than one year old the lateral and medial sides of the ankle were already slightly round. In another seven ankles the ball-and-socket appearance developed before the age of five years. This was thought to be due to osseous coalition which limits eversion and inversion. In another four ankles in children who were over the age of one year at the initial examination, the deformity was demonstrated by arthrography and radiography at their first examination. Ball-and-socket deformity accompanied by tarsal coalition is an acquired deformity secondary to limitation of movement of the subtalar and midtarsal joints. It has completely developed by about five years of age.

Adolescent↗