Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Programming, Linear”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Pharmacokinetics of vincristine sulfate in children.

A radioimmunoassay was used to measure vincristine sulfate concentrations in the serum of four children with malignancies (ages 5-16 years) following intravenous (IV) bolus injections. The pharmacokinetic data were analyzed by a non-linear least-square regression program NONLIN. A three-compartment open model fitted the raw data better than a two-compartment model in three patients. In the other patient the raw data fitted a two-compartment open model. The half-lives of the triphasic decay curves alpha, beta, and gamma were 2.6, 41, and 1,531 min (25.5 h), respectively. The mean apparent volume of the central compartment was 3.25 l, and the the volume of distribution per 1.73 m2 body surface area at steady state was 215.9 l. In a three-compartment open model, the first-order distribution and elimination rate constants (min-1) of vincristine were as follows: k12, 0.088; k13, 0.121; k21, 0.028; k31, 0.0026; k10, 0.045. The plasma clearance was 146.2 ml/min per 1.73 m2, while the AUC0 infinity was 27,816 nM . min. Urinary excretion in one patient demonstrated a drug concentration of greater than 1.0 X 10(-7) M in the urine up to 78 h after the injection. Up to 37% of the administered drug was excreted in the urine as vincristine and/or its metabolites by 90 h. The low elimination rate constant from poorly perfused tissues to blood plasma (k31), a large apparent volume of distribution, and a long biological half-life (25.5 h) indicate avid tissue binding from which a slow release of the drug from the body tissues occurs.

Adolescent↗

The effect of density-dependent treatment and behavior change on the dynamics of HIV transmission.

In this work, we propose a model for heterosexual transmission of HIV/AIDS in a population of varying size with an intervention program in which treatment and/or behavior change of the infecteds occur as an increasing function of the density of the infected class in the population. This assumption has socio-economic implications which is important for public health considerations since density-dependent treatment/behavior change may be more cost-saving than a program where treatment/behavior change occurs linearly with respect to the number of infecteds. We will make use of the conservation law of total sexual contacts which enables us to reduce the two-sex model to a simpler one-sex formulation. Analytical results will be given. Unlike a similar model with linear treatment/behavior change in Hsieh (1996) where conditions were obtained for the eradication of disease, we will show that density-dependent treatment/behavior change cannot eradicate the disease if the disease is able to persist without any treatment/behavior change. This work demonstrates the need to further understand how treatment/behavior change occurs in a society with varying population.

Acquired Immunodeficiency Syndrome↗

Estimation of glomerular filtration rate in children.

The aim of this study was to develop a method to predict the glomerular filtration rate (GFR) in children by using the population pharmacokinetic approach. This powerful approach is widely used for drug development in order to study relationships between patients' characteristics (demographic, morphological, biological covariates) and pharmacokinetic parameters. For the first time, (51)Cr-EDTA plasma concentrations from 64 children (development data set) were analyzed using the Non-linear Mixed Effects Model (NONMEM) program to determine the most appropriate equation to relate (51)Cr-EDTA clearance (as a measurement of GFR) and patient characteristics. The most predictive equation was based on body weight, square height, and plasma creatinine (PCr, determined by the Jaffé method). This equation was then validated using the data from a further 33 patients. This equation produced estimates of GFR that were less biased and more precise than those obtained using the widely used Schwartz formula. The coefficient of correlation between estimated and actual GFR was 0.83, and the 10th to 90th percentiles for percentage errors were -20% to +30%. Finally, analysis of the whole data set (97 patients) led to an equation (i.e., GFR (ml/min)=[56.7 x Body weight (kg)+0.142 x Length(2)(cm)]/PCr ( microM)) very similar to that obtained from the development data set. This equation would be useful for estimating GFR in children when isotopic determination of the (51)Cr-EDTA clearance cannot be performed.

Adolescent↗

An improved data analysis method for interleukin 2 microassay.

Development of the interleukin 2(IL 2) microassay, coupled with the use of highly purified or recombinant factors has allowed a detailed examination of the mechanism of action of this important biological response modifier. However, probit analysis of the microassay data does not allow inherent error of the system to be approximated nor can units of activity be assessed for significance. A computer program was developed to analyze the validity of each regression line and to generate 95% confidence intervals around each line. This program employs analysis of variance, linear regression analysis and the parallel line assay to fix confidence intervals for each IL 2 unit value. The use of recombinant IL 2 as an immunomodulator in clinical settings warrants a more precise statistical method to evaluate normal fluctuations of this factor than currently in use. The development of such a method is presented here.

Biological Assay↗

Method of analysis of non-competitive enzyme immunoassays for antibody quantification.

A computerized analysis of a quantitative enzyme-linked immunoadsorbent assay (EIA) using a non-specific immunoglobulin (IgG) of known concentration as the standard has been developed for measuring specific antibody levels in serum without the need for affinity purification of the positive control antibody. The computer program utilized logit-log linear regression analysis of sigmoid serial dilution curves plus a weighted least-squares best curve fit analysis and an iterative manipulation to eliminate errant data points. The EIA was performed using serial dilutions of standard and unknown antibodies, and a double sandwich technique. A comparison of antibody levels determined by EIA using non-specific IgG as a standard relative to antibody levels determined using affinity-purified specific antibody as a standard were 1.04, 0.53, 0.48, and 0.97 for four different polyclonal antibody systems. Five monoclonal antibodies to carcinoembryonic antigen gave ratios as described above of 1.07, 1.59, 1.73, 2.32, and 2.42. The corresponding antibody affinity constants (1/mol) were 1.0 X 10(8), 3.8 X 10(8), 5.5 X 10(9), 1.8 X 10(10), and 2.6 X 10(10) respectively. This method permits accurate quantification of serum antibody levels when affinity-purified antibodies are not readily available and avoids errors due to loss of antibody activity during affinity purification.

Amino Acids↗

An acoustic study of vowel production in aphasia.

A group of five anterior and seven posterior aphasic patients were recorded for their vowel productions of the nine nondipthong vowels of American English and compared to a group of seven normal speakers. All phonemic substitutions were eliminated from the data base. A Linear Predictive Coding (LPC) computer program was used to extract the first and the second formant frequencies at the midpoint of the vowel for each of the remaining repetitions of the nine vowels. The vowel duration and the fundamental frequency of phonation were also measured. Although there were no significant differences in the formant frequency means across groups, there were significantly larger standard deviations for the aphasic groups compared to normals. Anterior aphasics were not significantly different from posterior aphasics with respect to this greater formant variability. There was a main effect for vowel duration means, but no individual group was significantly different from the other. Standard deviations of duration were significantly greater for the anterior aphasics compared to normal speakers, but not significantly different from posterior aphasics. Posterior aphasics did not have significantly greater standard deviations of duration than did normal subjects. Greater acoustic variability was considered to evidence a phonetic production deficit on the part of both groups of aphasic speakers, in the context of fairly well-preserved phonemic organization for vowels.

Adult↗

Capillary gas chromatography of underivatized fatty acids with a free fatty acid phase column and a programmed temperature vaporizer injector.

Underivatized fatty acids occurring in lipids of a number of biological specimens (blood plasma, tissues, food) were studied using a capillary column with a chemically bonded free fatty acid phase and a programmed temperature vaporizer. Non-linear calibration dependences were obtained for almost all the acids at lower concentrations because of losses in the column, non-linearity increasing with increasing carbon number and degree of unsaturation. Sample introduction at temperatures below the solvent boiling point eliminates losses in the injector. The lower recovery of long-chain polyunsaturated acids is caused by interactions occurring in the column. Some critical pairs remain unresolved in the underivatized form (18:1n9-18:1n7, 20:4n6-20:3n3), whereas the corresponding methyl esters exhibit baseline resolution.

Chromatography, Gas↗

Smoking cessation processes in low-SES women: the impact of time-varying pregnancy status, health care messages, stress, and health concerns.

UNLABELLED: We tracked smoking outcomes - quitting, stage of readiness, action, motivation, self-efficacy, and confidence - over time among 943 low-SES women smokers accrued in an earlier smoking cessation intervention trial conducted in public health clinics. We assessed outcomes at 2, 6, 12 and 18 months post-initial clinic visit. Controlling for baseline characteristics and earlier program participation, we used hierarchical linear modeling to assess how intervening life events - pregnancy and exposure to subsequent clinic smoking interventions - affected smoking outcomes directly and indirectly, through the mediators, perceived stress and health concerns. RESULTS: All longitudinal smoking outcomes were positively related to health concerns and negatively related to perceived stress. Pregnancy favorably influenced all smoking outcomes but confidence, but exposure to additional interventions affected only motivation. Health concerns and stress partially mediated the positive impact of pregnancy. CONCLUSION: Public health efforts targeted to low-SES women smokers should continue to emphasize the benefits of quitting smoking for health maintenance and incorporate more effective stress-coping mechanisms. Pregnancy increases abstinence, but preventing post-delivery relapse may require stress management and re-focusing of health concerns.

Attitude to Health↗

Gel permeation chromatography of dextrans in parenteral solutions: calibration procedure development and method validation.

We describe development and validation of a gel permeation chromatographic (GPC) method for dextrans in parenteral solutions. The GPC method was adopted from USP monographs on Dextran 40 and Dextran 70 raw materials. The method was optimized with a mobile phase flow rate of 1 mL/min and column temperature of 40 degrees C, to sharpen dextran and dextrose peaks. An easy-to-use, curve-fitting program capable of non-linear regression was developed in-house, using Microsoft Excel and its Solver add-in to successfully meet the GPC calibration requirements for dextrans and dextrose, i.e., the experimental molecular weights within 100+/-5% of the known molecular weights for dextrans and molecular weight of dextrose within 180+/-2 Da. The GPC method was validated in terms of its stability indicating nature, robustness (column temperature of 40+/-3 degrees C), accuracy (lack of effects of pH and concentration of dextrans or matrix components), and precision (repeatability and intermediate). Molecular weight distribution of dextrans were unchanged when the dextran containing test solutions were subjected to forced degradation using heat, light (daylight and UV light), extreme alkaline conditions or oxidative conditions. The method was capable of detecting changes in molecular weight distribution caused by degradation under extreme acidic conditions and heat, thereby confirming the stability indicating nature of the method. The concentration of Dextran 40 and Dextran 70 (75-125% of the nominal assay concentration), matrix components (108-111% of their nominal concentrations), and solution pH (pH 3-7 for Dextran 40 solutions and pH 4-7 for Dextran 70 solutions) did not affect the measured molecular weight distribution of Dextran 40 or Dextran 70. The method was precise with %R.S.D. of less than 1% for M (W) values of Dextran 40 or Dextran 70.

Chromatography, Gel↗

Calculation of biochemical net reactions and pathways by using matrix operations.

Pathways for net biochemical reactions can be calculated by using a computer program that solves systems of linear equations. The coefficients in the linear equations are the stoichiometric numbers in the biochemical equations for the system. The solution of the system of linear equations is a vector of the stoichiometric numbers of the reactions in the pathway for the net reaction; this is referred to as the pathway vector. The pathway vector gives the number of times the various reactions have to occur to produce the desired net reaction. Net reactions may involve unknown numbers of ATP, ADP, and Pi molecules. The numbers of ATP, ADP, and Pi in a desired net reaction can be calculated in a two-step process. In the first step, the pathway is calculated by solving the system of linear equations for an abbreviated stoichiometric number matrix without ATP, ADP, Pi, NADred, and NADox. In the second step, the stoichiometric numbers in the desired net reaction, which includes ATP, ADP, Pi, NADred, and NADox, are obtained by multiplying the full stoichiometric number matrix by the calculated pathway vector.

Adenosine Diphosphate↗

Evaluation of a particle-enhanced turbidimetric immunoassay for the measurement of ferritin: application to patients participating in an autologous blood transfusion program.

OBJECTIVES: To evaluate a turbidimetric immunoassay for the measurement of ferritin, and to assay this method in a group of patients undergoing an autologous blood transfusion program. DESIGN AND METHODS: We used an ILab 900 analyzer. This instrument automates a particle-enhanced immunoturbidimetric assay with an analysis time of 9 min. This technique was compared with a microparticle immunoassay. The turbidimetric assay was used to measure ferritin in a group of 30 patients undergoing an autologous blood transfusion program. RESULTS: The assay was linear in the range 3-1400 microg/L (r = 0.9999). The intra- and inter-assay imprecision (CV) at 20, 97 and 469 microg/L were <3.0 and <5.0%, respectively. Recovery was 88. 7 to 97.4%. The detection limit was 3 microg/L. Hemoglobin (</=4 g/L), mild hyperbilirubilinemia (bilirubin </=50 micromol/L), triglycerides (</=10 mmol/L) and myeloma paraproteins did not interfere with the assay. The assay showed good correlation with a microparticle enzymoimmunoassay (r = 0.994) with a mean difference between methods of -6 +/- 16 microg/L. This method was sensitive, accurate, and fast enough for an efficient follow-up of autologous blood transfusion patients. CONCLUSIONS: The new automated serum assay for ferritin is an attractive alternative that avoids the need for dedicated instrumentation.

Adult↗

A limited sampling strategy for determining carboplatin AUC and monitoring drug dosage.

There are several convincing reports showing relationships between the area under the curve of ultrafilterable concentration versus time (AUC) and pharmacodynamics of carboplatin. It is advisable, in treated patients, to check the AUC that is effectively delivered as compared with the prescribed AUC. To this end, limited sampling strategy seems to be an adequate approach since it limits the constraints of repeated blood sampling for both patients and nursing staff. A flexible limited sampling method for assessing ultrafilterable carboplatin AUC was developed. This method was based on a Bayesian estimation of carboplatin clearance using the NON linear Mixed Effect Model (NONMEN) program and a large pharmacokinetic and covariates database (103 patients). The optimal sampling design was a two-sample schedule (1 and 4 h after the end of infusion). During a prospective evaluation, it allowed an adequate estimation of carboplatin clearance with a non-significant bias (-4.5%) and a good precision (9%). In a second stage, this method was clinically applied to monitor carboplatin AUC in a group of 5 patients with metastatic germ cell tumours treated with intensified high dose carboplatin-based chemotherapy for 4 days. Dosage adjustments were performed according to daily controls of their AUC in order to obtain a total AUC of 20 mg/ml x min. By using this strategy all patients effectively received a total AUC very close to this targeted AUC, thus proving the clinical usefulness of this limited sampling method.

Antineoplastic Agents↗

The use of the G1 and Octosmart programs in detecting temporal changes in the visual field.

PURPOSE: The Octopus program Octosmart is able to classify visual fields into six classes. In the program a horizontal bar indicates these classes, and an indicator points to the most probable position, related to the measured pathology. The width of this dashed indicator shows the range of possible fluctuations in the measurement and, therefore, its precision. This study sets out to analyse the suitability of this display mode using other visual-field index data. METHODS: The visual fields of 83 glaucomatous eyes of 61 patients of various etiological groups and glaucoma suspects were studied for periods varying from 1 to 5 years in a retrospective study. All examinations were performed with the G1 Octopus program and analyzed with the Octosmart program. The statistical significance of linear trends of the visual-field indices, mean defect (MD) and corrected loss variance (CLV), and the class shown by the indicator (POI = position of indicator) were determined, and their regression coefficients were analyzed by means of a linear trend test as a function of time. RESULTS: Of the sample of 83 tested eyes, a total of 18 significant trends were recorded after five examinations. All visual-field indices showed a trend towards amelioration. CONCLUSIONS: The 18 significant trends observed must be attributed to perturbing long-term fluctuations and, despite their statistical significance, are of little clinical value. It is questionable whether an increased number of examinations per eye would have attenuated the threshold fluctuations sufficiently to make the change in field class more reliable.

Adult↗

High-throughput pedigree drawing.

Family trees have long been a valuable visual tool for geneticists in identifying clusters of inherited traits and genotypes. As more data are collected, drawing the graphs by hand becomes impractical and, for this reason, we have developed the pedigree software CraneFoot. It can process any family graph with minimal computational cost by making a pedigree transformation that enables the use of a linear node positioning algorithm. The program is designed for automated drawing to printed media and efficient visual classification of genetically interesting families from large data sets. It also incorporates a robust pedigree topology check with detailed error messages.

Algorithms↗

Comparative population pharmacokinetics of lorazepam and midazolam during long-term continuous infusion in critically ill patients.

AIMS: It is well established that there is a wide intra- and interindividual variability in dose requirements for lorazepam and midazolam in intensive care patients. The objective of this study was to compare the population pharmacokinetics of lorazepam and midazolam after long-term continuous infusion in mechanically ventilated critically ill patients. METHODS: Forty-nine critically ill patients randomly received either lorazepam (n = 28) or midazolam (n = 21) by continuous infusion for at least 24 h. Multiple blood samples were obtained for determination of the drug and metabolite concentrations by HPLC. Population pharmacokinetic models were developed using the Non-Linear Mixed Effect Modelling (NONMEM) program. The influence of selected covariates was investigated. The prospective performance of the models was evaluated on the basis of results in separate groups of patients for lorazepam (n = 31) and midazolam (n = 33). RESULTS: The pharmacokinetics of lorazepam were best described by a two-compartment model. Alcohol abuse, positive end expiratory pressure (PEEP) and age were identified as significant covariates. Total body clearance for patients without alcohol abuse was 4.13 - (PEEP - 5) x 0.42 l h-1, and 0.74 l h-1 for patients with alcohol abuse. The volume of distribution was 0.74 l, the steady state volume of distribution was 56 - (age - 58) x 2.1 l and the intercompartmental clearance was 10 l h-1. The proportional residual error was 15% and the median absolute prediction error was 13.6% with a bias of 1.5%. The pharmacokinetics of midazolam were best described by a two-compartment model with alcohol abuse, APACHE score and age as significant covariates. Total body clearance for patients without alcohol abuse was 11.3 - (age - 57) x 0.14 l h-1, and 7.27 - (age -57) x 0.14 l h-1 for patients with alcohol abuse. The volume of distribution was 7.15 l, the steady state volume of distribution was 431 l, and the intercompartmental clearance was 40.8 - (APACHE score - 26) x 2.75 l h-1. The proportional residual error was 31% with an additive residual error of 32 ng ml-1. The median absolute prediction error was 12.9% with a bias of 1.2%. The prospective performance in the lorazepam evaluation group was better with the covariate adjusted model, but in the midazolam evaluation group it was not better than with the simple model. In all models a tendency to overestimate the lower plasma concentrations was observed. CONCLUSIONS: The pharmacokinetics of both lorazepam and midazolam were well described by a two-compartment model. Inclusion of alcohol abuse and age as covariates improved both models. PEEP was identified as an additional covariate for lorazepam, and the APACHE score for midazolam. For both drugs there is a large interindividual variability in their pharmacokinetics when used for long-term sedation in critically ill patients. However, the intra-individual variability is much lower for lorazepam.

Adolescent↗

Extended storage of platelets in a new plastic container. II. In vivo response to infusion of platelets stored for 5 days.

A new blood container material (PL 1240 plastic) made of polyvinyl chloride containing a tri(2-ethylhexyl) trimellitate plasticizer was evaluated in three laboratories. When platelet concentrates (50-60 ml) were stored on a variety of agitators for 7 days at 22 +/- 2 degrees C, poststorage pH (mean +/- SD) ranged from 7.29 +/- 0.05 (6 rpm elliptical rotator) to 6.87 +/- 0.8 (70 cycles per minute flatbed agitator). The platelet counts ranged from 1.51 +/- 0.12 to 0.95 +/- 0.36 X 10(6) per microliter. Morphology scores and hypotonic shock response values of platelets stored 7 days in PL 1240 plastic containers were better than those noted following 3-day storage of control platelets in PL 146 plastic containers. The percent discharge of lactic dehydrogenase from platelets stored 7 days in PL 1240 plastic containers for 3 days (p less than 0.05). Mean platelet recoveries of 44 +/- 15 percent (n = 11; 111Indium) and 39 +/- 8 percent (n = 29; 51Chromium) were seen when autologous platelets were infused following 5-day storage in PL 1240 plastic bags. Platelet half-lives of 3.6 +/- 0.4 (n = 9) 4.1 +/- 0.4 (n = 20) days were reported in the two laboratories which used 51Cr labeling, while survival values of 7.0 +/- 1.0, 2.8 +/- 0.8, and 5.4 +/- 1.9 days were seen when data from the 111Indium studies (n = 11) were analyzed using linear, exponential, and multiple hit programs, respectively. Platelets stored for 5 days also were administered to 13 thrombocytopenic oncology patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Platelets↗

Pharmacokinetics and pharmacodynamics of ximelagatran.

Oral anticoagulant therapy with vitamin K antagonists (VKAs) such as warfarin has proven benefits in the treatment and prevention of thromboembolic disorders but has important limitations that result in substantial underuse. In particular, the VKAs have variable and unpredictable pharmacokinetics and pharmacodynamics and a narrow separation between antithrombotic and hemorrhagic effects that necessitates careful dose adjustment based on frequent coagulation monitoring. In contrast, the oral direct thrombin inhibitor ximelagatran has a predictable and reproducible pharmacokinetic/pharmacodynamic profile that allows treatment using fixed-dose regimens without coagulation monitoring. The bioavailability of melagatran, the active form of ximelagatran, after oral administration of ximelagatran is approximately 20% with low inter- and intra-individual variability. Peak plasma melagatran concentrations are reached approximately 2 hours after oral dosing of ximelagatran to healthy volunteers, and melagatran is eliminated with a half-life of approximately 3 hours with clearance predominantly by renal excretion. Hence, a higher melagatran exposure is seen in patients with renal failure; ximelagatran is currently not recommended for patients with severe renal impairment (creatinine clearance of <30 mL/min) as these patients were not included in the clinical trial program. Exposure to melagatran increases linearly with the ximelagatran dose. The pharmacokinetic/pharmacodynamic profile is consistent across a broad range of different patient populations and is unaffected by gender, age, body weight, ethnic origin, obesity, and mild-to-moderate hepatic impairment. Any differences in melagatran pharmacokinetics associated with these factors are attributable to differences in renal function.

Administration, Oral↗