Revision of well-fixed cementless acetabular components for polyethylene failure.

The results of revision of well-fixed Porous Coated Anatomic cementless acetabular components for polyethylene failure or periacetabular osteolysis in 18 hips (14 patients) are reported. Revisions were done with larger diameter cementless acetabular components replacing one-piece Porous Coated Anatomic devices for which no replacement liner was available. The objective was to determine the increase in size of the revision acetabular component and to assess clinical and radiographic outcomes. The Porous Coated Anatomic components were in place for an average of 7.8 years. At an average followup of 68 months, all revision components remain in place. Preoperatively, 12 hips in 10 patients had radiographic osteolysis, and 25 osteolytic lesions in 17 patients were grafted at revision. All grafted lesions showed partial or complete evidence of bone graft consolidation. The average revision component size increased 8.5 mm in diameter (range, 3-14 mm) compared with the primary component size. This corresponded to an average 6.5-mm increase in the acetabular cavitary diameter. When locking mechanism failure in a well-fixed cementless acetabular component prevents polyethylene liner replacement, acetabular component revision can provide good clinical and radiographic results with acceptable bone loss and improved access to osteolytic areas for debridement and grafting.

Acetabulum↗

The pros and cons of polyethylene sterilization with gamma irradiation.

This retrospective study evaluated the implant, patient and surgical factors associated with polyethylene wear for one type of porous-coated hemispheric total hip arthroplasty cup. Radiographic wear measurements among 567 Duraloc cups (512 patients) revealed that liners sterilized by gamma-irradiation wore 0.085 mm/year less than those that were sterilized by gas-plasma, a noncross-linking chemical surface treatment. The substantially decreased wear rate associated with gamma-irradiation was attributed to sterilization-induced polyethylene cross-linking. Shelf-aging adversely affected liners that were gamma irradiated in air. On average, highly crystalline Hylamer liners showed a 0.064 mm/year increase in wear rates for each year of shelf storage after terminal sterilization with gamma-irradiation in air. Among conventional Enduron liners, the effect of shelf aging after gamma-irradiation in air was more modest, increasing wear rates by 0.014 mm/year for each year of shelf storage. Because Hylamer's wear performance degraded at about five times the rate of Enduron's, the improved wear resistance associated with gamma-irradiation in air would be lost after 1.3 years of shelf aging for Hylamer compared with 6.1 years for Enduron. For every additional year of age at the time of surgery, the wear rate decreased by 0.003 mm/year. Increased body mass index, a preoperative diagnosis of inflammatory arthritis, and a ceramic femoral head also were associated with decreased wear rates.

Aged↗

Clinical study of a modified Brooks technique for atlanto-axial subluxation using polyethylene tape.

Forty-four patients, 15 males and 29 females (3-71 years old; mean age, 52.9), were treated for the control of cervical instability with a modified Brooks operation using Tekmilon tape (an ultrahigh molecular weight polyethylene tape) instead of metal wires. Forty of the patients had rheumatoid arthritis (RA) with atlanto-axial subluxation (AAS), three patients had os odontoideum, and one patient had a cervical spine injury. The mean follow-up period was 8 years and 4 months. These patients were divided into three groups: 30 years or less, 31 to 60 years, and over 60 years. Atlanto-dental interval (ADI), inclination angle of atlanto-axial vertebrae (A-A angle), and bone fusion were examined on plain radiographs. The proportion of patients with reduced neck pain (Ranawat's grade 0 or grade 1) increased from 42.5% to 97.9% at the time of postoperative evaluation. Surgical complications, such as dural tear, lamina fracture, and spinal cord injury did not occur in any cases. Thirty-nine patients (88.6%) achieved bone union. ADI in the maximum flexed position improved from 10.3 to 2.5 mm. There was no statistical difference between ADI in males and females. ADI did not change in any age group both before and after surgery. A-A angle also improved from 9.4 to 24.4 degrees. The polyethylene tapes, used for internal fixation, caused no neurologic complications during sublaminar wiring and produced no MR artifacts. This modified Brooks technique using Tekmilon tape was proved to be a simple and safe treatment of AAS.

Adult↗

Effect of synthetic bone glass particulate on the fibrovascularization of porous polyethylene orbital implants.

PURPOSE: To determine the effects of synthetic bone glass particulate (BG) on the fibrovascular ingrowth that occurs in porous polyethylene orbital implants (PP). METHODS: Forty-eight rabbits were divided into 4 groups, according to the different surgical techniques and implanted materials used. Group 1 was enucleated and implanted with PP, group 2 underwent evisceration and was implanted with PP, group 3 was enucleated and implanted with BG, and group 4 underwent evisceration and was implanted with BG. All of the implants in each group were histologically assessed at postoperative weeks 1, 2, 4, and 8. RESULTS: There was no statistically significant difference with regard to fibrovascular ingrowth in the 4 groups. A greater number of vessels per unit area and mature fibrous tissue were found in the outermost zone for a longer time after implantation, but we found no statistically significant differences among the 4 groups. CONCLUSIONS: We conclude that inclusion of synthetic bone glass particulate did not result in any significant increases in the rates of fibrovascular ingrowth in porous polyethylene orbital implants in rabbits.

Animals↗

Facial skeletal reconstruction using porous polyethylene implants.

A retrospective review of clinical outcomes was performed to determine the clinical utility and morbidity associated with the use of porous polyethylene facial implants. Three hundred seventy implants were placed in 162 consecutive patients, in 178 operations performed in 11 years. The number of patients, the number of implants used, and the average follow-up period were categorized according to the cause of the deformity. The resultant distribution was as follows: acquired (tumor-related), 17 patients, 39 implants, and 30 months; congenital, eight patients, 31 implants, and 92 months; aesthetic, 39 patients, 97 implants, and 24 months; secondary posttraumatic, 48 patients, 139 implants, and 37 months; and acute trauma (internal orbit reconstruction), 50 patients, 64 implants, and 9 months. The distribution of implants according to location was as follows: frontal, 21; temporal, 30; internal orbit, 145; infraorbital rim, 28; malar, 58; paranasal, 29; nasal, 13; mandible, 24; and chin, 22. The combined average follow-up period per patient was 27 months (range, immediate postoperative period to 11 years). All implants were placed in the subperiosteal plane, and the majority were fixed with titanium screws. Antibiotics were administered perioperatively. No implants were extruded or migrated, formed clinically apparent capsules, or caused symptoms attributable to bioincompatibility. The overall reoperation rate was 10 percent (n = 16), which included operations to remove implants because of acute infections (2 percent, n = 3) or a late infection (1 percent, n = 1), to remove implants causing displeasing contours (2 percent, n = 3), and to improve contours (6 percent, n = 9). Porous polyethylene implants have biomaterial properties favorable for facial skeletal augmentation. Screw application of the implants to the skeleton allows precise predictable contouring, thus limiting the need for revisional surgical procedures.

Adolescent↗

Dynamic effects of a 9 mm missile on cadaveric skull protected by aramid, polyethylene or aluminum plate: an experimental study.

BACKGROUND: Most military helmets are designed to prevent penetration by small firearms using composite materials in their construction. However, the transient deformation of the composite helmet during a non penetrating impact may result in severe head injury. METHOD: Two experimental designs were undertaken to characterize the extend of injuries imparted by composite panels using in protective helmets. In the first series, 21 dry skulls were protected by polyethylene plates, with gaps between the protective plate and skull ranging from 12 to 15 mm. In another design, using 9 cadavers, heads were protected by aluminum, aramid, or polyethylene plates. Specimens were instrumented with pressure gauges to record the impact response. The ammunition used in these experiments was 9 mm caliber and had a velocity of 400 m/s. A macroscopic analysis of the specimens quantified fractures and injuries, which were then related to the measured pressures. RESULTS: Protective plates influenced both the levels of injury and the intracranial pressure. Injuries were accentuated as the plates was changed from aluminum to composite materials and ranged from skin laceration to extensive skull fractures and brain contusion. Fractures were associated with brain parenchymal pressures in excess of 560 kPa and cerebrospinal fluid pressure of 150 kPa. An air gap of a few millimeters between the plate and the head was sufficient to decrease these internal pressures by half, significantly reducing the level of injury. CONCLUSIONS: Ballistic helmets made of composite materials could be optimized to avoid extensive transient deformation and thus reduce the impact and blunt trauma to the head. However, this deformation cannot be completely removed, which is why the gap between the helmet and the head must be maintained at more than 12 mm.

Acceleration↗

A simple radiographic measurement method for polyethylene wear in total knee arthroplasty.

This study describes a new method for evaluating polyethylene wear in total knee arthroplasty. Since the amount of wear is dependent on a number of variables such as the weight and activity of the patient, it should be estimated based on in vivo measurements. We used a computer vision technique called three-dimensional/two-dimensional (3-D/2-D) matching to perform in vivo assessment using a single-plane radiograph. Using the 3-D/2-D matching algorithm we estimated the 3-D position and orientation of each knee implant and then measured the femorotibial distance, which is defined as the shortest perpendicular distance from the tibial tray to the femoral component. The accuracy of the proposed 3-D/2-D matching method was determined by in vitro investigations. The worst errors in in-plane/out-of-plane translations and rotations were 0.20/1.95 mm and 0.17/0.29 degrees, respectively. The root-mean-square error in femorotibial distance measurements using real polyethylene inserts was 0.04 mm. Results of in vivo femorotibial distance measurements are also described.

Humans↗

Comparative pharmacokinetic properties of murine monoclonal antibody A7 modified with neocarzinostatin, dextran and polyethylene glycol.

The murine monoclonal antibody A7 (Mab A7) was chemically modified with several macromolecules: dextran, polyethylene glycol and the anti-cancer polypeptide neocarzinostatin. The pharmacokinetic properties of the combinations were subsequently examined. Radioimmunoassay revealed that all preparations retained their antigen-binding activities. The Mab A7-neocarzinostatin conjugate was cleared from the blood circulation with a kinetic pattern almost identical to that of the parent Mab A7. Of the three preparations, Mab A7-dextran (A7-Dx) was removed the most rapidly from the circulation. Mab A7-polyethylene glycol (A7-PEG) exhibited the slowest blood clearance curve, with twice the half life of the parent Mab A7 in the circulation. In normal organ distributions, A7-Dx exhibited the highest liver, spleen and kidney uptake, and A7-PEG showed the lowest uptake, when expressed as tissue:blood ratio. Although A7-Dx exhibited lower tumor uptake, there was no significant difference among the three conjugates in tumor-bearing nude mice. A7-PEG seems to be a good candidate for targeted cancer therapy using antibody due to its high blood retention but low normal organ uptake.

Animals↗

Use of tegaserod along with polyethylene glycol electrolyte solution for colonoscopy bowel preparation: a prospective, randomized, double-blind, placebo-controlled study.

BACKGROUND: Polyethylene glycol electrolyte solution (PEG-EL) used for colonoscopy preparation is not well tolerated by several patients. A significant number of patients have inadequate bowel preparation despite taking PEG-EL. AIMS: To determine the effect of prokinetic agent, tegaserod when given in addition to PEG-EL on patient tolerance, quality of colonic preparation and adverse side effects experienced. METHODS: In this prospective, randomized, placebo-controlled, double-blind study, a total of 130 patients scheduled for colonoscopy were enrolled. They were instructed to take three pills of either tegaserod 6 mg each or placebo (one pill twice on the day prior to and third pill in the morning on the day of colonoscopy) in addition to standard 4L of PEG-EL in the evening prior to the day of colonoscopy. Patient tolerance of preparation, quality of bowel preparation, overall satisfaction and adverse side effects were compared between the two groups. RESULTS: Fifty-five patients in placebo group and 58 patients in tegaserod group completed the study. There was no difference between the two groups in the tolerance of preparation, quality of bowel preparation, overall satisfaction and the side effects. CONCLUSION: Addition of tegaserod to polyethylene glycol electrolyte solution during colonoscopy preparation does not improve patient tolerance, quality of colonic preparation or the adverse side effects.

Colon↗

Fate of chlorbutol during storage in polyethylene dropper containers and simulated patient use.

The disappearance of chlorbutol from aqueous solutions stored in polyethylene containers under various experimental and simulated patient use conditions is described. Chlorbutol is lost by sorption into the container wall, container insert and by permeation into the external environment. The extent of chlorbutol loss from solution and uptake by the container components is dependent on temperature, chlorbutol concentration and the closure used. Aqueous chlorbutol solutions stored in the polyethylene container evaluated have a predicted shelf-life (time for 10% loss) of about 4 months at 25 degrees C and 8 months at 20 degrees C. Negligible loss is found during simulated patient use over 1 month.

Chlorobutanol↗

Multipin peptide synthesis at the micromole scale using 2-hydroxyethyl methacrylate grafted polyethylene supports.

The multipin peptide synthesis procedure has been adapted to allow the synthesis of peptides at micromole loadings. The original solid pin support was replaced with a detachable crown-shaped polyethylene support with an increased surface area. In addition, the polyethylene crowns were radiation-grafted with 2-hydroxyethyl methacrylate monomer instead of acrylic acid to yield hydroxy functionalized supports with a larger concentration of polymer and hence a larger peptide capacity. Fmoc-beta-Alanine was directly esterified to the HEMA hydroxy groups with subsequent addition of a diketopiperazine-forming handle for peptide attachment. Peptides varying in length from 10 to 25 residues were assembled at a number of loadings from 1.0 to 2.2 mumol. Purity of peptides at all loadings was equal to, and in some instances superior to, that achieved on conventional solid-phase supports.

Amino Acid Sequence↗

Polyethylene skin wrapping accelerates recovery from hypothermia in very low-birthweight infants.

BACKGROUND: Thermal management of the very low-birthweight (VLBW) infant is a cornerstone of neonatology because thermal stress is an important determinant of survival. This prospective study was designed to determine the effects of polyethylene occlusive skin wrapping on heat loss in VLBW infants admitted to the neonatal intensive care unit (NICU) promptly after birth. METHODS: Thirty consecutively inborn infants weighing <1500 g were allocated to a wrap or non-wrap group within an incubator after admission to the NICU. Axillary and incubator temperatures were taken on arrival at 1 and 2 h. RESULTS: Infants in the wrap group reached a normal axillary temperature faster then non-wrap infants and required lower incubator temperatures. CONCLUSIONS: Polyethylene film wrapping effectively helps to correct hypothermia in VLBW infants admitted to the NICU.

Female↗

Microwave sterilization of polyethylene catheters for intermittent self-catheterization.

A standard household 650 W microwave oven was used to sterilize polyethylene catheters of the type used for intermittent self-catheterization. The catheters were infected with Proteus sp. bacteria and microwaved at 650 W for periods of 2, 4, 6 and 8 minutes. The effect of microwaving was assessed by determining the resultant colony counts following catheter culture. It was determined that 6 minutes of microwaving were required to achieve sterility. It is suggested that use of a microwave oven is a reliable and cost-effective method of sterilizing polyethylene catheters for intermittent self-catheterization.

Catheterization↗

Protection of ROC-1 hybrid glial cells by polyethylene glycol following ATP depletion.

Oligodendroglia-glioma hybrid cells (ROC-1) subjected to inhibition of glycolytic and oxidative ATP synthesis undergo a sequence of changes, including ATP depletion, parallel processes of cell swelling and blebbing, and finally plasma membrane disruption and cell death. The morphological and biochemical changes that follow ATP depletion were studied in the presence and absence of polyethylene glycol (M(r) 8,000), a nonpermeant oncotic agent. Polyethylene glycol prevented cell swelling and membrane blebbing. It significantly delayed, but did not prevent, the release of lactate dehydrogenase into the medium; it did not affect the fall in [ATP]. These results suggest that osmotic cell swelling may be a contributing factor in the loss of cell viability when ROC-1 cells are depleted of ATP.

Adenosine Triphosphate↗

A highly efficient polyethylene glycol-mediated transformation method for mushrooms.

A highly efficient transformation system mediated by polyethylene glycol was developed for the cultivated mushroom Pleurotus ostreatus. Eighty to 180 integrative and stable-resistant colonies appeared per mug of DNA per 10(7) viable protoplasts in a transformation experiment with the hygromycin B phosphotransferase gene (hph), which is about 40-1800 times higher than that previously reported in P. ostreatus. One hundred to 150 transformants emitting green fluorescence were observed per mug of DNA per 10(7) viable protoplasts in a transformation with the green fluorescent protein gene, but green fluorescence disappeared 30 h after transformation, suggesting that the green fluorescent protein gene was only transiently expressed in P. ostreatus. Plasmid pAN7-1 was also transferred into two important cultivated mushrooms, Ganoderma lucidum and Lentinus edodes, and 120-150 and 85-100 transformants per mug of DNA per 10(7) viable protoplasts were obtained, respectively, which is seven to 38 times and 24-28 times greater than previously reported. These data indicate that this new polyethylene glycol-mediated transformation procedure is highly efficient for mushrooms, and could be a useful tool in mushroom improvement by gene engineering.

Drug Resistance, Fungal↗

Combined technique with polyethylene fibers and composite resins in restoration of traumatized anterior teeth.

Traumatized anterior teeth need quick esthetic and functional repair. Esthetic requirements of anterior teeth require the use of composite materials which, in the most complex cases, can be used in association with fibers so as to improve their mechanical resistance. Many kinds of fibers are available. The authors considered parameters such as physical properties, water absorption, ease of cutting and of laying. Polyethylene fibers appear to have the best properties in elasticity, translucency, adaptability, tenaciousness, resistance to traction and to impact. Fifteen children, between 7 and 13 years old, with crown fractures of the anterior sector were treated. In the case of a simple crown fracture, the missing part was restored by polyethylene fibers and composite resins. In the case of a complex crown fracture needing endodontic treatment, the fibers were used as a central core stump in order to restore the dental morphology. At control examinations, the teeth restored by this technique were acceptable, both in function and in aesthetics. Thus, the authors recommend this combined technique for predictable restoration of traumatized anterior teeth.

Adolescent↗

Ultrastructural localization of tubulin and actin in polyethylene glycol-embedded rat seminiferous epithelium by immunogold staining.

The polyethylene glycol (PEG) method for immunofluorescence localization of cytoskeletal antigens has been extended to the ultrastructural level using glutaraldehyde-fixed tissues and immunogold staining. Semithin sections of fixed tissue embedded in polyethylene glycol are divested of the PEG, exposed to purified antibodies (e.g., antiactin, antitubulin) and anti-IgG-colloidal gold. The sections may be processed by dehydration and critical-point drying, or reembedment in hydrophilic substances. Tubulin is demonstrated in the mitotic spindles of dividing spermatogonia, manchettes, axonemes and centrioles of developing spermatids, and in the Sertoli cell cytoplasm; actin localization is demonstrated in the myoid cells of the tunica propria, and smooth muscle cells of arterioles in the interstitial tissue. The results demonstrate the applicability and versatility of PEG embedding for immunocytochemistry.

Actins↗

Acrylic resins reinforced with woven highly drawn linear polyethylene fibres. 3. Mechanical properties and further aspects of denture construction.

Previous work has established the feasibility of producing acrylic denture bases reinforced with layers of highly drawn linear polyethylene fibres in a woven form. This paper reports on the mechanical properties of the system, including the effect of water conditioning. It is confirmed that substantial improvements in impact strength can be obtained by the incorporation of the polyethylene fibres in woven form. The fibre/resin integration within the dentures has also been studied by optical microscopy. It was found that delamination may occur during some processing stages and steps are suggested to avoid this problem.

Acrylic Resins↗