Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

The Insall-Burstein II prosthesis: a 5- to 9-year follow-up study in osteoarthritic knees.

We prospectively studied 100 Insall-Burstein Posterior Stabilized II total knee arthroplasties (Zimmer Inc, Warsaw, IN) consecutively implanted in 91 patients with osteoarthritis. We reviewed 92 knees in 85 patients at a mean follow-up of 7.5 years (range, 5.3-9.5 years). According to the Knee Society score, 78 (85%) results were excellent, 11 (12%) were good, and 3 (3%) were fair or poor. The unsatisfactory results were attributed to patellofemoral pain with a low patella (2 knees) and to valgus alignment and medial laxity (1 knee). Flexion at follow-up averaged 116 degrees. Nonprogressive radiolucent lines were present around 30% of the tibial components. There was only 1 small osteolytic lesion around the tibial plateau. We observed no aspetic loosening, infection, or patella stress fracture. Survivorship analysis in the worst-case scenario showed a 90.9% success rate at 8 years.

Aged↗

[Total prosthesis on a rheumatoid knee].

Results of 81 total knee replacements in 67 patients with rheumatoid arthritis were studied. Mean follow-up was three years. Pain was the main reason for knee replacement surgery; knee mobility was well preserved prior to surgery. Failure occurred in four patients, as the result of infection, due in three instances to skin necrosis. Arthrodesis of the knee proved necessary in these patients. The fourth patient developed delayed hematogenous infection which was treated by a change of prosthesis. At follow-up, 82% of patients reported no pain and 18% moderate pain. Mean passive flexion was 113 degrees +/- 17 degrees. HSS score was 83.6 +/- 1.3 and all the patients except for the four with prosthesis failure stated that they were satisfied on very satisfied. Mechanical results were satisfactory, with a mean mechanical femur-tibial angle of 180.4 degrees. A circling line was visible at follow-up in 40% of operated knees but was partial in every case. No reoperations for prosthesis loosening were required. These data show that total knee replacement is the only reliable and radical treatment of rheumatoid arthritis of the knee and should be performed as soon as fixed flessum or axial deviation develops.

Adult↗

New knees now.

Explore the source record for details and available documents.

Arthroplasty↗

Muscle flaps in total knee arthroplasty.

The results of 12 patients who had been treated with muscle flap coverage for compromised soft tissues associated with total knee arthroplasty were studied. Five latissimus dorsi free flaps, 6 medial gastrocnemius rotational flaps, and 2 rectus abdominis free flaps were done in 12 knees. The authors used and classified 3 types of muscle flaps: (1) prophylactic soft tissue coverage, done before definitive reconstruction; (2) treating muscle flap for infected prostheses with deficient soft tissue coverage; and (3) salvage muscle flap for wound dehiscence or necrosis in the immediate postoperative period. These patients were observed for an average of 4.1 years (range, 1-8 years). The wound was revascularized successfully in 100% of the knees. The prosthesis was preserved in 83% of the knees. Recurrent infection occurred in 3 patients. Treating muscle flaps are least likely to result in an overall successful reconstruction because these flaps are used in knees with chronic infection. Prophylactic flaps and salvage muscle flaps provide the soft tissue coverage necessary to allow successful reconstruction in the appropriate circumstances.

Adult↗

Total knee arthroplasty in patients </=50 years old.

Thirty patients (30 knees) who underwent total knee arthroplasty at age </=50 were reviewed. These patients were operated on between July 1, 1991, and May 1, 1995, with final follow-up evaluation at a mean of 86 months (range, 60-107 months). At final evaluation, 18 knees (60%) had excellent Knee Society objective scores, 11 knees (37%) had good scores, and 1 knee (3%) had a poor score. There were no statistically significant differences in Knee Society objective scores among the cemented group (mean, 88 points), hybrid group (mean, 88 points), and noncemented group (mean, 90 points). One patient (3%) had a revision because of unexplained pain. In the other knees, there was no radiographic evidence of progressive loosening, lucencies, or change in position or alignment of the prosthesis. Total knee arthroplasty of this design, at least for the time period studied (7-year mean follow-up), has a high rate of success in patients who are </=50 years old.

Adult↗

[Revision of unicompartmental knee arthroplasty].

Despite the good midterm survivorship reported for unicondylar knee arthroplasty, an increase in revision surgery has to be expected due to increased replacement rates. The reasons for failure as well as distribution are different for unicondylar knee arthroplasty compared to total knee arthroplasty. The main reasons for revision are aseptic loosening and the progression of osteoarthritis. In most cases, unicondylar knee arthroplasty will be revised to total knee arthroplasty. To obtain good revision results, the cause of implant failure has to be analysed carefully. In the case of contained bone defects, the reconstruction can be supported with bone grafting. For those cases with uncontained defects, implants with augmentation and, in some cases, stem extensions are needed. The modularity of the revision implant should cover different intraoperative requirements.

Arthroplasty, Replacement, Knee↗

[Alkaptonuria and ochronotic arthropathy. Arthroscopic and intraoperative findings in implantation of a knee joint surface replacing prosthesis].

Alcaptonuria is a rare (incidence approx. 1:10(6)), autosomal-recessive transmitted metabolic disease. The basic defect is a lack of the enzyme homogentisic acid oxidase. During metabolism of phenylalanin and tyrosin to fumaric acid and acetoacetic acid this enzymatic defect causes an accumulation of the intermediate breakdown product homogentisic acid in bradytrophic tissues resulting in pigmentation and calcification of the intervertebral disks. We present a 57 year old female patient in whom we diagnosed alcaptonuria by the appearance of the typical symptom trias homogentisic acid excretion in the urine, ochronosis and arthritis. The anamnesis and results of a knee arthroscopy, radiographic and laboratory examinations as well as the intraoperative and histological findings during implantation of a knee joint surface replacing prosthesis (Gemini-System, Link Co., Hamburg, Germany) are reported.

Alkaptonuria↗

The press-fit condylar modular total knee system with a posterior cruciate-substituting design. A concise follow-up of a previous report.

The purpose of the present study was to determine the long-term results of a series of 150 consecutive primary posterior stabilized modular knee arthroplasties that had been performed in 118 patients with use of a circumferential tibial insert capture as described in a previous report, published in 1997. The patients were evaluated with use of a patient-administered questionnaire; Knee Society clinical, functional, and radiographic scoring systems; and Kaplan-Meier survivorship analysis. A good to excellent result was confirmed in seventy-six (90%) of the eighty-four patients (105 knees) with a mean duration of follow-up of twelve years (range, ten to thirteen years). At twelve years, the survival rate was 94.6% +/- 4.0% with failure for any reason as the end point and 98.3% +/- 2.4% with mechanical failure as the end point. Revision surgery was performed in five knees because of infection (two knees), dislocation (one knee), and substantial polyethylene wear with femoral osteolysis (two knees). We concluded that, while fixation failure is rare, polyethylene wear and osteolysis are emerging as important causes of failure.

Arthroplasty, Replacement, Knee↗

[Treatment of degenerative disease of knee joint with the Oxford prosthesis].

Eleven patients with single compartment arthrosis of the knee were treated surgically, using the Oxford prosthesis. The age of the patients at the time of surgery ranged from 48 to 73 years. Varus deformity of the knee before surgery ranged from 0-23 degrees (average: 11 degrees). Patients with arthrosis of the medial compartment were elected for surgery. Surgery was performed only when passive correction of the varus deformity was possible and when the cruciate ligaments were intact. In all cases surgery yielded a stable knee joint.

Aged↗

Bondgraph modelling and simulation of the dynamic behaviour of above-knee prostheses.

A mathematical model was used to investigate the dynamic behaviour of an above-knee (AK) prosthesis in the swing phase and to analyse the influence of mass and mass distribution on the maximal stump load and the required energy. The model consists of a bondgraph model of the prosthesis and a "walking" model which predicts the walking velocity, step length and the femoral trajectory. Equipment was developed to measure the inertial properties of the components of the prosthesis. Through computer simulation, stickdiagrams of the swing phase and graphs of the variation with time of the hip and stump forces were obtained. It was found that for a normal AK prosthesis with a knee-lock mechanism the axial stump load is greatest at the beginning and at the end of the swing phase. At a walking velocity of 5 km/hr the maximum axial stump load amounts to 2.1 times the static weight of the prosthesis. The maximum axial stump force appeared to be almost directly proportional to the total mass of the prosthesis but independent of the mass distribution. The required energy also increased with the mass of the prosthesis but is dependent on mass distribution. Because of their comparable weights the influence of the shoe is almost equal to the influence of the prosthetic foot. Thus lightweight shoes should be used with lightweight prosthetic feet in order to add to their advantages.

Artificial Limbs↗

Salvage revision total knee replacement using the Endo-Model rotating hinge prosthesis.

Inability to balance a knee in complex revision total knee replacement has led to the use of rotating hinged knee devices in these cases as a salvage procedure. We conducted a retrospective study of 50 patients receiving 51 Endo-Model rotating hinge prosthesis with an average follow-up of 4 years (range 2-6 years). Clinical and radiological results were reviewed at latest follow-up. Five patients died from unrelated causes. Reasons for revision were infection (23), aseptic loosening (23), implant failure (3), stiffness (1) and peri-prosthetic fracture (1). The average number of previous surgery from and including the primary arthroplasty was three (ranges 1-14). Seven patients required plastic surgery for soft tissue cover. There was notable improvement in the pain, stability, range of motion and mobility of the patients with an improvement in the Hospital for Special Surgery Score (35.9 to 72.17). Postoperatively, 11 (22%) had an excellent HSS grade, 22 (44%) good grade, 10 (19%) fair grade and 8 (15%) poor grade. A significant number of our patients had an extremely low preoperative HSS score, and for these patients, an improvement to a fair grade HSS score was a satisfactory and realistic outcome. Forty-four (86%) patients were satisfied with the outcome of the revision surgery, 3 (6%) noncommittal and 4 (8%) disappointed. Comparing revision for infection vs. aseptic loosening, 22 (95%) patients out of 23 were satisfied in the aseptic loosening group vs. 17 (74%) out of 23 were satisfied in the infected group. In selected complex cases, salvage revision surgery shows encouraging results in the short to medium term using the Endo-Model rotating hinge prosthesis. A knee score such as the Hospital for Special Surgery score (objective outcome) should be used in conjunction with a patient satisfaction questionnaire (subjective outcome) in assessing the clinical outcome of complex, salvage revision knee surgery. Revision for infected total knee replacement is less likely to produce a satisfactory outcome as compared to revision for aseptic loosening.

Adult↗

Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up.

The condylar constrained total knee arthroplasty was performed on 29 patients undergoing 33 procedures and were reviewed clinically and radiographically at an average follow-up of 5 years (range, 2-10 years). There were 21 women and 8 men. The average age at the time of surgery was 70 years (range, 32-84). Of the 16 knees that were revision total knee arthroplasties, 8 had a previous infected total knee arthroplasty, and 17 knees had severe deformities requiring the use of the condylar constrained prosthesis. The patients were rated according to the Knee Society clinical and radiological evaluation protocol. Measurements of femoral and tibial component position were obtained as well as femoral tibial angle, patella position, and cement bone radiolucencies. All clinical measurements were made by an independent physical therapist. Clinical results revealed an improvement from an average preoperative knee score of 38 points to an average postoperative score of 86 points. The clinical results for 19 (58%) knees were excellent, 8 (24%) had a good result, 1 (3%) was fair, 2 (6%) were poor, and 3 (9%) were failures. The patients' average functional levels increased from 24 to 58. The final average flexion was 96 degrees. Three knees have been revised (9%). One was revised for recurrent infection, one for periprosthetic fracture, and one for mechanical loosening of the tibial component. There were no other knees with evidence of radiologic loosening. We conclude that the condylar constrained total knee prosthesis provides an acceptable solution for revision and complex primary total knee replacements at an intermediate follow-up term of 5 years.

Adult↗

Role of rifampin for treatment of orthopedic implant-related staphylococcal infections: a randomized controlled trial. Foreign-Body Infection (FBI) Study Group.

CONTEXT: Rifampin-containing regimens are able to cure staphylococcal implant-related infections based on in vitro and in vivo observations. However, this evidence has not been proven by a controlled clinical trial. OBJECTIVE: To evaluate the clinical efficacy of a rifampin combination in staphylococcal infections associated with stable orthopedic devices. DESIGN: A randomized, placebo-controlled, double-blind trial conducted from 1992 through 1997. SETTING: Two infectious disease services in tertiary care centers in collaboration with 5 orthopedic surgeons in Switzerland. PATIENTS: A total of 33 patients with culture-proven staphylococcal infection associated with stable orthopedic implants and with a short duration of symptoms of infection (exclusion limit <1 year; actual experience 0-21 days). INTERVENTION: Initial debridement and 2-week intravenous course of flucloxacillin or vancomycin with rifampin or placebo, followed by either ciprofloxacin-rifampin or ciprofloxacin-placebo long-term therapy. MAIN OUTCOME MEASURES: Cure was defined as (1) lack of clinical signs and symptoms of infection, (2) C-reactive protein level less than 5 mg/L, and (3) absence of radiological signs of loosening or infection at the final follow-up visit at 24 months. Failure was defined as (1) persisting clinical and/or laboratory signs of infection or (2) persisting or new isolation of the initial microorganism. RESULTS: A total of 18 patients were allocated to ciprofloxacin-rifampin and 15 patients to the ciprofloxacin-placebo combination. Twenty-four patients fully completed the trial with a follow-up of 35 and 33 months. The cure rate was 12 (100%) of 12 in the ciprofloxacin-rifampin group compared with 7 (58%) of 12 in the ciprofloxacin-placebo group (P=.02). Nine of 33 patients dropped out due to adverse events (n=6), noncompliance (n=1), or protocol violation (n=2). Seven of the 9 patients who dropped out were subsequently treated with rifampin combinations, and 5 of them were cured without removal of the device. CONCLUSION: Among patients with stable implants, short duration of infection, and initial debridement, patients able to tolerate long-term (3-6 months) therapy with rifampin-ciprofloxacin experienced cure of the infection without removal of the implant.

Aged↗

Systemic metal-protein binding associated with total joint replacement arthroplasty.

The distribution of titanium [Ti] and chromium [Cr] in serum protein fractions of patients with and without total joint replacements containing Cr and Ti was studied. Three groups were evaluated: 10 patients with cobalt-chromium [CoCr] alloy prostheses and known elevated levels of Cr; 10 patients with Ti containing implants and known elevated levels of Ti; and 10 age matched controls without prostheses. Metal-protein binding was also examined by adding various concentrations of Cr(+3) (CrCl(3)) to control serum. Cr and Ti were bound to serum proteins within specific molecular weight ranges in both patient groups. Two molecular weight ranges were found to bind Cr (at approximately 70 and approximately 180 kDa) in patients with CoCr alloy prostheses, whereas a single molecular weight range (at approximately 70 kDa) was found to bind Ti in patients with Ti alloy implants. This metal-protein binding was reproduced in vitro by adding CrCl(3) at concentrations of approximately 100 and 1000 ppb Cr, which is orders of magnitude higher than that contained in the serum of patients with CoCr alloy implants ( approximately 3 ppb Cr). This suggests that protein binding is initiated in the periprosthetic space where metal concentrations are typically 2-3 orders of magnitude higher than that observed systemically in the serum. In vitro, high molecular weight proteins including immunoglobulins demonstrated the highest affinity to Cr. Determination of specific protein carriers of metal degradation products is an essential component in the assessment of the long-term biological affects of total joint replacement devices.

Adult↗

Signal measurement strategies: are they feasible and do they offer any advantage in outcome measurement in osteoarthritis?

The applicability of a signal measurement strategy was compared with a traditional method of measuring outcome in osteoarthritis. The signal method detected statistically significant alterations in health status with small sample sizes and with a relative efficiency close to or at unity. The prevalence of deterioration in nonsignal items was low. Signal methods of measurement may provide an alternative approach to outcome measurement in osteoarthritis clinical trials.

Feasibility Studies↗

Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements.

Sensitivity to nickel, cobalt, and chromium is common among the general population. The identification of these sensitivities is generally by the detection of cell-mediated immunity. Detection of humoral immunity to these metals has rarely been undertaken because suitable assays are not available. To further our knowledge about the systemic humoral immune system response to weak hapten-syngeneic or allogeneic protein conjugates (corrosion and wear products of metallic orthopedic devices), a sensitive enzyme-linked immunosorbent assay (ELISA) method for testing for antibody (humoral immunity) to metals was developed. Microtiter plates were coated with human serum albumin (HSA) or glutathione (GSH) and then conjugated with metal ions. Plates coated with HSA or GSH and without metal ions served as background controls. An indirect ELISA method was used to detect antibody binding. Patients bearing cobalt-chromium alloy devices were considered to be the most likely candidates as sources of antibody to metal and were used to document the usefulness of the test. Specificity of the test was documented by inhibition studies with these metal ions in the ELISA assay. The serum samples of 10 patients were screened for the presence of Cr-, Co-, or Ni-specific antibody at various periods up to 5.5 years after implantation of F-75 cobalt alloy total joint replacements. All patients had implants that were functioning well. The pre- and postimplantation humoral immune profiles of patients were determined and compared with each preimplantation control and with a pooled normal serum sample. This study presents evidence that metal-protein complex-specific antibodies can be detected. The clinical implications remain to be determined.

Antibodies↗