Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Joint Instability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Simultaneous feedforward recruitment of the vasti in untrained postural tasks can be restored by physical therapy.

BACKGROUND AND PURPOSE: Physical therapy rehabilitation strategies are commonly directed at the alteration of muscle recruitment in functional movements. The aim of this study was to investigate whether feedforward strategies of the vasti in people with patellofemoral pain syndrome can be changed by a physical therapy treatment program in a randomised, double blind, placebo controlled trial. SUBJECTS: Forty (25 female, 15 male) subjects aged 40 yrs or less (27.2+/-7.8 yrs). METHODS: Subjects were allocated to either a placebo treatment or a physical therapy intervention program. The postural challenge used as the outcome measure was not included in the training program. Electromyography (EMG) onsets of vastus medialis obliquus (VMO), vastus lateralis (VL), tibialis anterior and soleus were assessed before and after the six week standardised treatment programs. RESULTS: At baseline the EMG onset of VL occurred prior to that of VMO in both subject groups. Following physical therapy intervention there was a significant change in the time of onset of EMG of VMO compared to VL with the onsets occurring simultaneously. This change was associated with a reduction in symptoms. In contrast, following placebo intervention the EMG onset of VL still occurred prior to that of VMO. CONCLUSION AND DISCUSSION: The results indicate that the feedforward strategy used by the central nervous system to control the patella can be restored. Importantly, the data suggest that this intervention produced a change that was transferred to a task that was not specifically included in the training program. Furthermore, the change in motor control was associated with clinical improvement in symptoms.

Adult↗

The effect of initial graft tension on the biomechanical properties of a healing ACL replacement graft: a study in goats.

While a number of in vitro studies have shown that the tension on an anterior cruciate ligament (ACL) replacement graft at the time of fixation has an affect on joint stability, most in vivo studies have reported little or no long-term difference in outcome. The objectives of this study were to (1) establish a large animal model in which differences in knee stability are present at time-zero after ACL reconstruction with grafts fixed at a low (5 N) and high (35 N) initial tension and to (2) quantitatively determine if these initial effects remain after six weeks of healing and if the tensile properties of an ACL replacement graft are influenced by initial graft tension. Seventeen skeletally mature female Saanan breed goats were used. Using the robotic/UFS testing system, the knee kinematics and in situ forces in the replacement graft in response to an externally applied 67 N anterior-posterior (A-P) tibial load were evaluated at time-zero and after six weeks of healing. Afterward, the femur-ACL graft-tibia complexes (FGTCs) from the six-week group were tested under uniaxial tension so that the stress relaxation and structural properties of the FGTC were obtained. At time-zero, knees fixed with a high initial graft tension could better reproduce the A-P translation of the intact knee in response to the 67 N A-P tibial load. Further, in situ forces in these grafts were also closer to those in the intact ACL under the same external loading condition. After six weeks of healing, the A-P translation of the knee and in situ forces in the replacement grafts became similar for the low and high tension groups, while both were significantly different from controls. Further, the percentage of stress relaxation as well as the stiffness, ultimate load at failure, ultimate elongation at failure, and energy absorbed of the FGTCs for both reconstruction groups were not significantly different from each other, but were significantly different from controls. These results demonstrate that while the high initial graft tension could better replicate the normal knee kinematics at time-zero, these effects may diminish during the early graft healing process.

Animals↗

Arthroscopic studies of variants of the anterior horn of the medical meniscus.

The objective of this study was to arthroscopically analyse the morphology and dynamics of variants of the anterior horn of the medial meniscus of the knee (VAMM) and to then consider the pathological significance of these variants. VAMM was defined as knees in which the anterior horn of the medial meniscus is not attached to the tibia. Between April 1992 and March 1995, arthroscopy was performed on 953 knees of 903 patients. At the time of this examination, observation and probing were performed to determine the condition of the synovium, the synovial plica, the cartilage in all compartments, the meniscus, the cruciate ligaments, and the popliteal tendon. In particular, detailed examination was made of the anterior horn of the medial meniscus with regard to the point of insertion to the tibia and the degree of movement in knee flexion/ extension. Cases of VAMM diagnosed on the basis of the arthroscopic findings were classified into the following four categories: the ACL (anterior cruciate ligament) type, where the anterior horn of the medial meniscus was attached to the ACL; the transverse ligament type, where the anterior horn of the medial meniscus was attached to the transverse ligament; the coronary ligament type, where the anterior horn of the medial meniscus was attached to the coronary ligament; and the infrapatellar fold type, where the anterior horn of the medial meniscus was attached to the infrapatellar synovial fold. These patients were then analyzed with regard to the arthroscopic findings and the intra-articular lesions other than VAMM. In 98 (10.9%) of the total patients, 103 knees were classified as VAMM. Classification of those 103 knees using the above criteria showed 39 ACL type knees, 51 transverse ligament type knees, 11 coronary ligament type knees, and 2 infrapatellar fold type knees. The arthroscopic findings indicated that the anterior horn of the medial meniscus was not attached directly to the tibia in any of these knees. Probing and flexion/extension of the knee revealed hypermobility at the anterior horn of the medial meniscus. In this study, anterior knee pain syndrome was diagnosed in 12 (11.7%) of the 103 VAMM knees. In addition, there was no clear history of trauma in 20 of 23 knees found to have an isolated medial meniscus tear. In these cases, even detailed arthroscopic observation proved the causes of the symptoms or injury. On the basis of these findings, we surmised that the anterior portion shows hypermobility at the time of flexion/extension of the knee, regardless of the type of VAMM. In this study, we discussed the possibility that the existence of VAMM may become the cause of pain or injury to the meniscus.

Adolescent↗

Treatment of unstable osteochondritis dissecans lesions of the knee using autogenous osteochondral grafts (mosaicplasty).

Symptomatic osteochondritis dissecans lesions with minimal fragmentation that may be replaced within their crater have classically been treated by reattachment. The choice for internal fixation is varied. This article reports on the treatment of unstable osteochondritis dissecans lesions using autogenous osteochondral plugs as a means of biological internal fixation. The appearance on magnetic resonance imaging of osteochondral plugs at 6 and 9 months after transplantation is also presented.

Adolescent↗

The TRAC PS mobile-bearing prosthesis: design rationale and in vivo 3-dimensional laxity.

We present a posterior stabilized mobile-bearing prosthesis, TRAC PS, which has congruent contact from full extension to full flexion, allows for freedom of internal-external rotation, and has an automatic posterior shift in tibiofemoral contact on the tibia to maximize the quadriceps lever arm in flexion. TRAC PS has 2 radii of curvature in the sagittal plane, 1 for the distal femoral condyles and 1 for the posterior femoral condyles, as does the normal knee. The distal and posterior femoral condyles articulate congruently in the inner tracks or the outer tracks of the polyethylene bearing, respectively. Anterior or posterior sliding of the femoral condyles on the bearing or of the bearing on the tibial tray cannot occur, providing inherent anterior and posterior stability. Three-dimensional knee laxity testing was performed on 17 patients from 12 months to 25 months after total knee arthroplasty with the TRAC PS and on 18 healthy control subjects of similar ages. Normal ligament balancing and normal internal-external rotational laxity were achieved with the TRAC PS prosthesis. Anterior and posterior laxity in the patients with TRAC PS was significantly reduced compared with that of the control subjects.

Arthroplasty, Replacement, Knee↗

Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty.

Excessive external rotation of the femoral component can cause an abnormally tight popliteus tendon complex, which induces loss of rotational laxity of the knee in the late phase of knee flexion after total knee arthroplasty. This study evaluated the effect of popliteus tendon release on rotational and varus-valgus laxity of implanted knees with an excessively externally rotated femoral component. Rotational and varus-valgus laxity was measured with a knee kinematics testing device before and after total knee arthroplasty. External rotational positions of the femoral component of 5 degrees and 8 degrees were compared, and the effects of popliteus tendon release on rotational and varus-valgus laxity were evaluated. To further investigate this question, the effect of a conforming articular design was compared with that of a flat tibial surface. External rotational position of 5 degrees did not change rotational or varus-valgus laxity of the knee. With an 8 degrees external rotational position, however, external rotational laxity significantly decreased in knees with a conforming surface at angles of 30 degrees, 45 degrees, 60 degrees, and 90 degrees. After popliteus tendon release, external rotational laxity significantly improved at 90 degrees flexion and was identical to that of the normal knee. Internal rotational range was similar before and after popliteus tendon release. Popliteus tendon release did not affect the varus-valgus laxity (stability) with either articular surface.

Biophysical Phenomena↗

Total knee arthroplasty kinematics. An in vivo evaluation of four different designs.

Thirty-four patients who had 42 total knee arthroplasties during the past 5 years were examined. Four types of total knee arthroplasties (Tricon-M, PCA, Variable Axis, and Anametric) were evaluated, using a computerized knee evaluation system. The patients and 10 controls with normal knees were tested for anteroposterior stability with the Lachman test, medial/lateral stability at 20 degrees, varus/valgus stability at 20 degrees, internal/external rotation at 80 degrees and 20 degrees of flexion, and internal/lateral rotation (screw home) over the active range of motion. At 30 degrees of flexion, the Variable Axis prosthesis was 54% more constrained than the normal knee to anterior/posterior shear. The Anametric and the Variable Axis were more lax under varus/valgus stress than the normal knee by 85% and 71%, respectively. There were no statistical differences for any of the other tests.

Aged↗

The effect of posterior tibial slope on knee stability after Ortholoc total knee arthroplasty.

The effect of posterior tibial slope was evaluated in a rotationally unconstrained anterior cruciate ligament-sacrificing total knee replacement (Ortholoc, Dow Corning Wright, Arlington, TN). Sloping the surface 7 degree posteriorly loosened the knee to varus-valgus and anterior-posterior stress in flexion. Eliminating posterior slope improved varus-valgus stability in flexion but slightly increased anterior-posterior laxity in extension. Values for the 3 degree posterior slope knee were between the values for 0 degree and 7 degree sloped surfaces, but not significantly different statistically from either. Total knee replacement designs with a posterior tibial slope are likely to promote anterior-posterior and varus-valgus laxity in flexion, and those with no posterior slope or 3 degree posterior slope are most likely to achieve normal stability in flexion and extension.

Biomechanical Phenomena↗

Clinical and radiographic results of the Total Condylar III and Constrained Condylar total knee arthroplasty.

The Total Condylar III (Johnson and Johnson, Braintree, MA) and Constrained Condylar (Zimmer, Warsaw, IN) knee prostheses are nonlinked, semi-constrained prosthetic alternatives to rigid or rotating hinge prostheses for use in complex knee reconstructions. Forty-six Total Condylar III or Constrained Condylar prostheses were implanted with cement in 36 patients and followed for a mean of 5 years (range, 2-9 years). There were 25 primary total knee arthroplasties and 21 revision total knee arthroplasties. The knees were evaluated using The Hospital for Special Surgery 100-point knee rating system. Overall, 40 knees (87%) had a good or excellent clinical result, 2 knees (4%) had a fair result, and 4 knees (9%) had a poor result. There was one revision for loosening of a cemented, nonmodular Constrained Condylar prosthesis, and one knee had a debridement for a late, metastatic infection, but the components were retained. There were no mechanical failures in those knees that were primary arthroplasties, but two mechanical failures occurred in those knees that were revision arthroplasties. Radiographic review showed one asymptomatic loosening of a Constrained Condylar tibial component with an uncemented press-fit stem, and only 8 knees had scattered nonprogressive tibial bone-cement radiolucent lines. The Total Condylar III and Constrained Condylar semiconstrained prostheses are successful when used in complex knee reconstructions.

Adult↗

The Porous-Coated Anatomic total knee experience. Special emphasis on complications and wear.

One hundred sixty knees in 141 patients with the Primary Porous-Coated Anatomic prosthesis (Howmedica, Rutherford, NJ) were evaluated after a follow-up period of 5.6 years (range, 1-10 years). One hundred six knees were in the latest follow-up evaluation, including clinical examination and a defined standing radiograph with a follow-up period of 6.3 years (range, 3-10 years). Survivorship analysis regarding the cumulative revision rate (including completion with a patellar component) was 0.88 at the 8-year and 0.84 at the 10-year follow-up examination. The clinical result was satisfying/good, with a mean Hospital for Special Surgery score of 83 (range, 39-97). Five percent had thinning greater than 30% of the tibial component. The wear was calculated to be 1.0 mm (range, 0-9 mm), including three revised tibial components with heavy wear. Excluding the revised cases, the wear was 0.7 mm.

Aged↗

Cementless total knee arthroplasty in rheumatoid arthritis. A report on 51 AGC knees followed for 54 months.

Fifty-one primary consecutive cementless AGC 2000 (Anatomically Graduated Components, Biomet, Warsaw, IN) total knee arthroplasties were performed during 1985 through 1990 in 40 patients with rheumatoid arthritis. Forty-one knees (32 patients) were available for clinical and radiologic follow-up analysis after 24 to 76 months (median, 54 months). There was no pain in 33 knees and mild pain in the rest. Median range of motion was 110 degrees (range, 50 degrees-130 degrees). Median knee score was 90 (range, 71-97), and all knees were rated good or excellent. Radiolucencies greater than 1 mm were found under five tibial components, but no obvious migrations were seen. One tibial component was revised due to aseptic loosening. The cumulative success rate after 4 to 5 years was 97% (lower limit of 95% confidence interval, 91.8%). The medium-term results are considered to compare favorably with reported cemented series.

Adult↗

Computer-based method for the 3-D kinematic analysis of posterior cruciate ligament and postero-lateral corner lesions.

Posterior cruciate ligament (PCL) rupture, whether or not combined with postero-lateral corner (PLC) tears, are more often diagnosed today thanks to improved imaging techniques. However, due to the lack of reliable instrumentation to quantitatively evaluate the knee, much is still unknown about the function of these ligamentous structures. The aim of this paper is to present results on the effect of progressive resection of the PCL and PLC on knee laxity and 3-D knee kinematics. The results show that 3-D movement analysis is important and complements laxity measurements by helping to interpret the complex alteration of knee function.

Aged↗

Comparison of two methods for reconstruction of the posterior cruciate ligament using a computer based method: quantitative evaluation of laxity, three-dimensional kinematics and ligament deformation measurement in cadaver knees.

The aim of this paper is to present a biomechanical comparison of two different methods for reconstruction of the posterior cruciate ligament in cadaver knees. We used an original computer-based method allowing precise calculation of three-dimensional (3D) knee kinematic parameters as well as the estimation of combined graft deformation (elongation-flexion-torsion). After isolated posterior cruciate ligament (PCL) dissection, double bundle and 'over-the-bottom' methods were performed successively on each knee using synthetic polyester ligaments. The effect of pre-tensioning was tested with the 'over-the-bottom' method. antero-posterior (A-P) and rotational laxity as well as 3D kinematics were recorded and analysed. Our computer based method allowed us to show that both reconstruction methods were equivalent in restoring A-P and rotational laxity as well as kinematic curves. Combined deformation of the prostheses was equivalent for both ligaments.

Aged↗

Rating systems for total knee replacement.

The objective assessment of outcome of surgical procedures is assuming increasing significance as the culture of audit and revalidation advances. There is a clear need for surgeons in all fields, but especially in Orthopaedics, to be familiar with the available scoring systems and their relative strengths and weaknesses. It is clear from a recent survey of BASK members' practice that there is little consensus about which system to use (addendum). This review presents a summary of the scoring systems available for the assessment of patients undergoing total knee replacement. These scores are described in detail and their relative merits discussed. None of the systems reviewed is perfect but those developed most recently do appear to offer advantages over older systems. Overall, the Western Ontario and McMaster University Osteoarthritis Index, Short Form 36 and Oxford Knee Score have undergone the most thorough assessment of reliability and validity and are therefore appropriate for the assessment of outcome after total knee replacement.

Arthroplasty, Replacement, Knee↗

Computer based method for the three-dimensional kinematic analysis of combined posterior cruciate ligament and postero-lateral complex reconstructions on cadaver knees.

The aim of this study is to evaluate the effect of combined posterior cruciate ligament (PCL) and postero-lateral corner (PLC) reconstruction on laxity and three-dimensional kinematics of cadaver knees. We performed anatomical double bundle PCL reconstruction, and functional one bundle 'over-the-bottom' PCL reconstruction combined with one type of PLC reconstruction, running from the postero-lateral tibia to an isometric point near the lateral epicondyle of the femur. Our results showed that combined reconstruction was necessary to restore rotatory laxity. PLC reconstruction, according to the technique described, invariably created a shift towards internal rotation of the kinematic curves, compared to the intact knee.

Aged↗

Revision anterior cruciate ligament reconstruction using autografts with a polyester fixation device.

Twenty-nine patients who had undergone anterior cruciate ligament (ACL) revision were evaluated retrospectively between 1992 and 2000. A similar surgical technique was used in all cases. Twenty-six patients underwent revision following failed primary and revision surgery with the ABC scaffold ligament. There were 2 failed primary semitendinosus/gracilis (STG) autografts and one failed bone patella tendon bone (BPTB) autograft. Autologous hamstring tendons (STG) were used in 26 knees, quadriceps tendon in 2 and BPTB autograft in 1 knee. The Mark I Soffix soft tissue fixation device was used in 16 patients and 13 patients underwent reconstruction with the Mark II BH (Button Hole ) Soffix. Follow up evaluation included clinical examination, KT 2000 arthrometric side to side difference (SSD) assessment, Lysholm, Tegner and IKDC scoring. The average follow up time was 50+/-22 months. The overall SSD was 1.66+/-1.5 mm, a mean Lysholm score of 87.2+/-12.5 was obtained and 22 patients had an IKDC score of nearly normal (B). In the Mark II (BH Soffix) group knees were significantly tighter than in the Mark I Soffix group (P<0.05) with a mean SSD of 1.23+/-1.3 and 2.0+/-1.6 mm, respectively. However there were no significant differences in the other measured parameters between the two fixation devices. Multiply re-operated knees tended to have lower IKDC and Lysholm scores (not statistically significant). We concluded that the technique reported in this study can restore stability to the knee following failed primary or revision ACL reconstruction and the results in the non-multiply operated knees are comparable to primary reconstruction.

Adult↗