Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

A novel crossed microfluidic device for the precise positioning of proteins and vesicles.

Herein we present a novel way to create arrays of different proteins or lipid vesicles using a crossed microfluidic device. The concept relies on the combination of I) a designated two-step surface chemistry, which allows activation for subsequent binding events, and II) crossing microfluidic channels for the local functionalization by separated laminar streams. Besides its simplicity and cost efficiency, this concept has the advantage that it keeps the proteins in a hydrated environment throughout the experiment. We have demonstrated the feasibility of such a device to create a chessboard pattern of different fluorescently labeled lipid vesicles, which offers the possibility to contain biomolecules, drugs or membrane proteins.

Equipment Design↗

Parallel measurements of drug actions on Erythrocytes by dielectrophoresis, using a three-dimensional electrode design.

A type of well-based assay that uses a laminated three-dimensional electrode design to characterise the effects of different drugs on red blood cells using dielectrophoresis is presented. The capability of the system to determine the effects of chemical agents on the electrophysiology of red blood cells is demonstrated using saponin and valinomycin as two examples of drugs that can penetrate the cell membrane and therefore change the dielectric properties of the cell. Light intensity changes are measured in the well over a period of time at various frequencies and the dielectric properties of the cells determined using an ellipsoidal multi-shell model. It is shown that the laminated electrode permits a high degree of automation and thus a high number of parallel experiments, which reduces both the time and effort needed to examine differences between populations of red blood cells. The technique is directly compatible with the industry-standard 1536 well-plate analysis technique.

Biological Assay↗

[Regional cerebral blood flow analysis by 133Xe intraarterial injection method. A comparison with cerebral infarction and cerebrovascular dementia].

Nine cases of cerebral infarction (cerebrovascular dementia 4 cases, hemiparesis 4, aphasia 1) were investigated by intraarterial 133Xe injection. Eight of the cases were male and one was female. Ages ranged from 38 to 72, with a mean age of 57.6 years. Two criteria were necessary for a diagnosis of cerebrovascular dementia: the presence of cerebrovascular disease and a score of less than 20 on Hasegawa's dementia scale. Cases of cerebrovascular dementia tended to have a lower mean cerebral blood flow (CBF) value on the white matter by two-compartmental analysis. Two of the five brain areas showed statistically significant differences. These results support the modern theory that cerebrovascular dementia appears as a result of a disturbance of the white matter. Cases of cerebrovascular dementia showed a lower mean CBF value with a coefficient of variance of regional distribution by height over area method. This showed that CBF values in cerebrovascular dementia were generally low and the range of values were narrow. In a comparison of regional CBF and cerebral angiographical findings, cases of cerebrovascular dementia tended to have a lower mean CBF value in proportion to the severity of angiographical findings. In addition, regional CBF showed a tendency to agree closely with angiographical findings.

Adult↗

A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flow.

A microchip-based capillary electrophoresis device supported by a microfluidic network made of poly(dimethylsiloxane), used for measuring target analytes from a continuous sample flow, is presented. The microsystem was fabricated by means of replica molding in combination with standard microfabrication technologies, resulting in microfluidic components and an electrochemical detector. A new hydrodynamic sample injection procedure is introduced, and the maximum number of consecutive measurements that can be made with a poly(dimethylsiloxane) capillary electrophoresis chip with amperometric detection is investigated with respect to reproducibility. The device features a high degree of functional integration, so the benefits associated with miniaturized analysis systems apply to it.

Biosensing Techniques↗

Small volume flow probe for automated direct-injection NMR analysis: design and performance.

A detailed characterization of an NMR flow probe for use in direct-injection sample analysis is presented. A 600-MHz, indirect detection NMR flow probe with a 120-microl active volume is evaluated in two configurations: first as a stand-alone small volume probe for the analysis of static, nonflowing solutions, and second as a component in an integrated liquids-handling system used for high-throughput NMR analysis. In the stand-alone mode, (1)H lineshape, sensitivity, radiofrequency (RF) homogeneity, and heat transfer characteristics are measured and compared to conventional-format NMR probes of related design. Commonly used descriptive terminology for the hardware, sample regions, and RF coils are reviewed or defined, and test procedures developed for flow probes are described. The flow probe displayed general performance that is competitive with standard probes. Key advantages of the flow probe include high molar sensitivity, ease of use in an automation setup, and superior reproducibility of magnetic field homogeneity which enables the practical implementation of 1D T2-edited analysis of protein-ligand interactions.

Equipment Design↗

Flow injection spectrophotometric determination of Al in hemodialysis solutions.

A flow analysis (FA) system with spectrophotometric detection for Al determination in hemodialysis solutions was developed. The method was based on the reaction of Al with eriochrome cyanine R (ECR). The complex formed associated with cetyltrimethylammonium bromide (CTAB)--a cationic surfactant, which showed enough sensitivity to execute the direct analyte determination. All interferences were eliminated with the matrix matching calibration. The system presented the following analytic parameters: sensitivity (m) of 8.10 x 10(-4)L microg(-1), limit of detection (LOD) of 3.24 microg L(-1) (3sigma), linear correlation coefficient of 0.9966 and linear range response from 10.8 to 650 microg L(-1). The accuracy of the proposed method was checked by comparison with electrothermal atomic absorption spectrometry (ET-AAS) method. There were no differences among the results obtained from both methods, at a confidence level of 95% (paired t-test). Recovery tests were also made, values obtained were from 90.4 to 109 of recovery for Al-spiked samples.

Aluminum↗

[Study on the determination of free iron oxide in soil extract by FIA-ICP-AES].

Free iron oxide in soil extract is determined by flow injection analysis-inductively coupled plasma-atomic emission spectrometry. The effects of the volume of the loading sample and the concentration of the extractants(NH2OH.HCl,H2C2O4) were investigated. When 50 microL sampling ring is selected and the concentration of two extractants is controlled under 10 mg.mL-1, sprayer nozzle is not blocked and feeding is smooth, the background interference is checked effectively as well. The recoveries of standard addition are 97.6%-100% with precision 2.3%-3.5% RSD(n = 5).

Ferric Compounds↗

Flow injection system based on the sandwich technique for saving expensive reagents.

We report the application of a sandwich technique in flow injection systems which afford low consumption of expensive reagents and two reagent recirculation systems. The potential applicability of the technique thus developed was assessed by determining glucose in serum samples by the enzymatic glucosidase/peroxidase method. It was possible to perform up to 450 determinations with the same amount of reagent used to perform 50 determinations by batch procedures. The sampling rate was 80 determinations per hour with a 0.9% relative standard deviation.

Blood Glucose↗

Molecular imprinted ormosils for nafcillin recognition by room temperature phosphorescence optosensing.

Nafcillin imprinted sol-gels were used as specific binding materials for the room temperature phosphorescence (RTP) recognition of nafcillin using a flow injection system. Selective and reversible binding of the template to imprinted sol-gels could be observed by tailoring the hydrophobic/hydrophilic balance of the materials. Also, the possibility of minimizing non-specific interactions was evaluated by end-capping with trimethyl silyl groups. Control experiments were performed with non imprinted reference sol-gels. The recognition mechanism and the analytical potential of these materials for developing stable, selective and sensitive approaches for nafcillin recognition in real samples are outlined.

Biosensing Techniques↗

Antioxidant activities of some Lamiaceae plant extracts.

The antioxidant activities of four Lamiaceae plants, Salvia viridis L., Salvia multicaulis Vahl, Stachys byzantina C. Koch and Eremostachys laciniata (L.) Bunge have been determined by using 1,1-diphenyl-2-picrylhydrazyl (DPPH) as well as by flow injection analysis-luminol chemiluminescence (FIA-CL). All extracts were shown to possess a significant scavenger activity against DPPH free radical and an inhibitory effect on H2O2- or HOCl-luminol chemiluminescence. The extracts scavenged 50% of DPPH radical ranging in the following descending order: Salvia viridis > Stachys byzantina > Salvia multicaulis > Eremostachys laciniata. The most potent extract on H2O2-induced peak chemiluminescence was that of Salvia viridis and on HOCl-induced peak chemiluminescence was that of Stachys byzantina. The results concluded that the extracts have a potential source of antioxidants of natural origin.

Antioxidants↗

Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection.

The present study reports a microfluidic system using the concept of membrane-movement to design and fabricate micro-pneumatic valves and pumps to form a bio-sensing diagnostic chip. The automatic bio-sampling system includes a micro-diagnostic chip fabricated by using MEMS (micro-electro-mechanical systems) technology and an automatic platform comprising of a control circuit, a compressed air source and several electromagnetic valve switches. The control circuit is used to regulate the electromagnetic valve switches, causing thin PDMS membranes to deflect pneumatically by the compressed air and generate valving and pumping effects. The micro-diagnostic chip allows for the quick detection of diseases. Compared to large-scale systems, the new microfluidic system uses smaller amounts of samples and reagents and performs fast diagnosis in an automated format. Instead of using traditional pneumatic micro-pumps, the current study adopts a new design called "spider-web" micro-pumps to increase the pumping rate, and more importantly, improve the uniformity of flow rates inside multiple micro-channels. Experimental data show that for disease diagnosis, the bio-sensing chips integrated with the micro-pneumatic valves and the peristaltic micro-pumps could successfully perform diagnosis tests. Small amounts of samples and reagents could be injected into the diagnosis chips using the micro-pumps and the micro-pneumatic valves could effectively control the movement of the samples and reagents. In order to demonstrate the functionality of the developed device, detection of hepatitis C virus (HCV) and syphilis has been performed using the bio-sampling chips. Experimental data show that fluorescence signals from the microfluidic system were comparable to the ones using conventional testing methods. The developed chip could be easily extended for multiple disease detection. The automatic bio-sensing chips could provide a useful tool for fast disease detection and be crucial for a micro-total-analysis system.

Biosensing Techniques↗

Semi disposable reactor biosensors for detecting carbamate pesticides in water.

Two flow-injection biosensor systems using semi disposable enzyme reactor have been developed to determine carbamate pesticides in water samples. Acetylcholinesterase was immobilized on silica gel by covalent binding. pH and conductivity electrodes were used to detect the ionic change of the sample solution due to hydrolysis of acetylcholine. Carbamate pesticides inhibited acetylcholinesterase and the decrease in the enzyme activity was used to determine these pesticides. Parameters influencing the performance of the systems were optimized to be used in the inhibition procedure. Carbofuran and carbaryl were used to test these systems. Detection limits for the potentiometric and conductimetric systems were both at 10% inhibition corresponding to 0.02 and 0.3 ppm of carbofuran and carbaryl, respectively. Both systems also provided the same linear ranges, 0.02-8.0 ppm for carbofuran, and 0.3-10 ppm for carbaryl. The analysis of pesticides was done a few times before the reactor was disposed. Percentages of inhibition obtained from different reactors were reproducible, therefore, no recalibration was necessary when changing the reactor. The biosensors were used to analyze carbaryl in water samples from six wells in a vegetable growing area. Both systems could detect the presence of carbaryl in the samples and provided good recoveries of the added carbaryl, i.e., 80-106% for the potentiometric system and 75-105% for the conductimetric system. The presence of carbaryl in water samples analyzed by the biosensors was confirmed by gas chromatography-mass spectrometric system. These biosensors do not require any sample preconcentration and are suitable for detecting pesticides in real water samples.

Acetylcholinesterase↗

Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis.

Microparticles have been manipulated in a microfluidic channel by means of negative dielectrophoresis (n-DEP), and the approach applied to a heterogeneous immunoassay system. A microfluidic device, with three-dimensional (3-D) microelectrodes fabricated on two substrates, was used to manipulate particle flow in the channel and to capture the particles in the caged area that was enclosed by the collector electrodes. Polystyrene microparticles (6 microm diameters) modified with anti-mouse immunoglobulin G (IgG) were manipulated and captured in the caged area when surrounded by intense n-DEP electric fields. Specifically, particles were trapped when AC voltages with amplitudes of 6-15 V(peak) and frequencies over 500 kHz were applied to the two facing microelectrodes. A heterogeneous sandwich immunoassay was achieved by successively injecting a sample solution containing mouse antigen (IgG), and a solution containing a secondary antibody with a signal source (FITC-labeled anti-mouse IgG antibody), into the channel. The fluorescence intensity from captured particles in the caged area increased with increasing concentrations (10 ng/ml to 10 microg/ml) of mouse IgG. The described system enables mouse IgG to be assayed in 40 min. Thus, the automatic separation of free fractions from desired analytes and labeled antibodies can be achieved using a microfluidic device based on n-DEP.

Biosensing Techniques↗

[Determination of antioxidation of the extract from Chinese medicine Morinda officinalis How by flow injection chemiluminescence and spectroscopy].

Flow injection chemiluminescence analysis was used to determine the antioxidation activity of extract from Morinda officinalis How. The determination was based on the inhibition effect of Morinda officinalis How extraction in the chemiluminescence reaction of luminol - H2O2-CuSO4 system, and vitamin C was used as positive control. It was showed that Morinda officinalis How original liquid has obvious anti-radical activity. Spectroscopy was applied to determine the inhibition ratio of Morinda officinalis How extraction for the superoxide anion and hydroxy radicals in the special system. It was shown that the extraction from Morinda officinalis How could obviously scavenge superoxide anion and hydroxy radicals. It is suggested that the Chinese Medicine Morinda Officinalis How is a potential antioxidation activity medicine.

Antioxidants↗

Direct determination of small cations in proteinaceous samples using a flow injection-capillary electrophoresis system.

A method is described for the direct determination of small inorganic cations in samples containing large amounts of proteins, such as milk or blood plasma. The method is based on electrokinetic injection in a flow injection analysis-capillary electrophoresis (CE) system. The selected CE-electrolyte, containing 5 mM 4-aminopyridine and 7 microM cetyltrimethylammonium bromide at pH 4.5, prevents detrimental protein adsorption on the capillary walls. Therefore, no sample pretreatment, except for dilution, is required. Up to 30 repeated injections in one electrophoretic run can be performed, yielding RSD values of the migration time of less than 1 and 2.5% (n=30) for milk and blood plasma samples, respectively.

Blood Proteins↗

Bi-enzyme reactor for electrochemical detection of low concentrations of uric acid and glucose.

An enzyme-based flow-injection amperometric analysis system (FIA) for monitoring of uric acid and glucose is described. The oxidase and peroxidase enzymes are physically coimmobilised in a sandwich-type reactor and ferrocene serves as a mediator. The assays are based on the measurement of a reduction current resulting from the enzymatic reactions, at a glassy carbon electrode held at 0.00 mV (vs. Ag/AgCl). The high selectivity (ascorbic acid did not interfere) is coupled to high sensitivity (a detection limit of 30 and 60 nmol/l for uric acid and glucose, respectively; signal/noise = 3) and good stability (the enzymes remained active for more than 6 weeks at 30 degrees C). The usefulness of the assay in clinical chemistry is illustrated by the measurement of human serum uric acid and glucose concentration. The results obtained were in fairly good agreement with those obtained using conventional hospital laboratory methods.

Ascorbic Acid↗

Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection.

Affinity proteins were covalently immobilised on silicon microchips with overall dimensions of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235 microm depth and 25 microm width, and used to develop microfluidic immunosensors based on horseradish peroxidase (HRP), catalysing the chemiluminescent oxidation of luminol/p-iodophenol (PIP). Different hydrophilic polymers with long flexible chains (polyethylenimine (PEI), dextran (DEX), polyvinyl alcohol, aminodextran) and 3-aminopropyltriethoxysilane (APTS) were employed for modification of the silica surfaces followed by attachment of protein A or G. The resulting immunosensors were compared in an affinity capture assay format, where the competition between the labelled antigen and the analyte for antibody-binding sites took place in the bulk of the solution. The formed immunocomplexes were then trapped by the microchip affinity capture support and the amount of bound tracer was monitored by injection of luminol, PIP and H2O2. All immunosensors were capable of detecting atrazine at the sub-microg l(-1) level. The most sensitive assays were obtained with PEI and DEX polymer modified supports and immobilised protein G, with limits of detection of 0.006 and 0.010 microg l(-1), and IC50 values of 0.096 and 0.130 microg l(-1), respectively. The protein G based immunosensors were regenerated with 0.4 M glycine-HCl buffer pH 2.2, with no loss of activity observed for a storage and operating period of over 8 months. To estimate the applicability of the immunosensors to the analysis of real samples, PEI and DEX based protein G microchips were used to detect atrazine in surface water and fruit juice, spiked with known amounts of the atrazine, giving recovery values of 87-102 and 88-124% at atrazine fortification levels of 0.5-3 and 80-240 microg l(-1), respectively.

Adsorption↗

Electroanalysis of tetracycline using nickel-implanted boron-doped diamond thin film electrode applied to flow injection system.

The electrochemical analysis of tetracycline was investigated using nickel-implanted boron-doped diamond thin film electrode by cyclic voltammetry and amperometry with a flow injection system. Cyclic voltammetry was used to study the electrochemical oxidation of tetracycline. Comparison experiments were carried out using as-deposited boron-doped diamond thin film electrode (BDD). Nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) provided well-resolved oxidation irreversible cyclic voltammograms. The current signals were higher than those obtained using the as-deposited BDD electrode. Results using nickel-implanted boron-doped diamond thin film electrode in flow injection system coupled with amperometric detection are presented. The optimum potential for tetracycline was 1.55 V versus Ag/AgCl. The linear range of 1.0 to 100 microM and the detection limit of 10 nM were obtained. In addition, the application for drug formulation was also investigated.

Anti-Bacterial Agents↗