Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Finite Element Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials.

PURPOSE: This study evaluated stress distribution in metal frameworks constructed on implants under masticatory forces using computer simulations. MATERIALS AND METHODS: Three-dimensional finite element analysis was used to study four different veneering materials-metal framework combinations using Calcitek implants. The veneering materials used in the study were porcelain, heat-polymerized poly(methyl methacrylate) resin, microfilled composite resin, and glass-modified composite resin. All computations were conducted for different levels on the buccal and lingual sides. RESULTS: Changing the veneering material on the prosthesis produced significant effects on stress levels and stress distribution on the metal frameworks. Stresses were concentrated along the marginal area of the prosthesis. Acrylic resin showed greater displacement than porcelain, probably because of its lower modulus of elasticity. CONCLUSION: In comparison to porcelain, more stress is borne by the acrylic resin-veneered metal framework under static loading.

Acrylic Resins↗

A theoretical framework for strain-related trabecular bone maintenance and adaptation.

It is assumed that density and morphology of trabecular bone is partially controlled by mechanical forces. How these effects are expressed in the local metabolic functions of osteoclast resorption and osteoblast formation is not known. In order to investigate possible mechano-biological pathways for these mechanisms we have proposed a mathematical theory (Nature 405 (2000) 704). This theory is based on hypothetical osteocyte stimulation of osteoblast bone formation, as an effect of elevated strain in the bone matrix, and a role for microcracks and disuse in promoting osteoclast resorption. Applied in a 2-D Finite Element Analysis model, the theory explained the formation of trabecular patterns. In this article we present a 3-D FEA model based on the same theory and investigated its potential morphological predictability of metabolic reactions to mechanical loads. The computations simulated the development of trabecular morphological details during growth, relative to measurements in growing pigs, reasonably realistic. They confirmed that the proposed mechanisms also inherently lead to optimal stress transfer. Alternative loading directions produced new trabecular orientations. Reduction of load reduced trabecular thickness, connectivity and mass in the simulation, as is seen in disuse osteoporosis. Simulating the effects of estrogen deficiency through increased osteoclast resorption frequencies produced osteoporotic morphologies as well, as seen in post-menopausal osteoporosis. We conclude that the theory provides a suitable computational framework to investigate hypothetical relationships between bone loading and metabolic expressions.

Adaptation, Physiological↗

Effect of fiber orientation on the stress distribution within a leaflet of a polymer composite heart valve in the closed position.

Polymer trileaflet valves offer natural hemodynamics with the potential for better durability than commercially available tissue valves. Strength and durability of polymer-based valves may be increased through fiber reinforcement. A finite element analysis of the mechanics of a statically loaded polymer trileaflet aortic heart valve has been conducted. A parametric analysis was performed to determine the effects of fiber orientation and volume density in a single and double ply model. A maximum stress value of 1.02MPa was obtained in the non-reinforced model for a transvalvular load (downstream-upstream) of 120mmHg. The maximum stress on the downstream side of the leaflet was approximately twice the maximum stress on the upstream side, and always occurred on the interface with the valve stent. The single ply model reduced the stress on the polymer matrix, with the maximum reduction of at least 64% occurring when the fiber orientation was such that the fibers ran perpendicular to the stent edge. The double ply model further reduced the stress on the polymer matrix, with the maximum reduction of greater than 86% now occurring when the fibers are oriented most perpendicular to one another.

Biomechanical Phenomena↗

Trabecular shear stresses predict in vivo linear microcrack density but not diffuse damage in human vertebral cancellous bone.

Linear microcracks and diffuse damage (staining over a broad region) are two types of microscopic damage known to occur in vivo in human vertebral trabecular bone. These damage types might be associated with vertebral failure. Using microcomputed tomography and finite element analysis for specimens of cancellous bone, we estimated the stresses in the trabeculae of human vertebral tissue for inferosuperior loading. Microdamage was quantified histologically. The density of in vivo linear microcracks was, but the diffuse damage area was not, related to the estimates of von Mises stress distribution in the tissue. In vivo linear microcrack density increased with increasing coefficient of variation of the trabecular von Mises stress and with increasing average trabecular von Mises stress generated per superoinferior apparent axial stress. Nonlinear increase in linear crack density, similar to the increase of the coefficient of variation of trabecular shear stresses, with decreasing bone stiffness and bone volume fraction suggests that damage may accumulate rather rapidly in diseases associated with low bone density due to the dramatic increase of shear stresses in the tissue.

Adult↗

Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains.

Experimental evidence indicates that the surface geometry of bone-interfacing implants influences the nature and rate of tissues formed around implants. In a previously reported animal model study, we showed that non-functional, press-fitted porous-surfaced implants placed in rabbit femoral condyle sites osseointegrated more rapidly than plasma-sprayed implants. We hypothesized that the accelerated osseointegration observed with the porous-surfaced design was the result of this design providing a local mechanical environment that was more favourable for bone formation. In the present study, we tested this hypothesis using finite element analysis and homogenization methods to predict the local strains in the pre-mineralized tissues formed around porous-surfaced and plasma-sprayed implants. We found that, for loading perpendicular to the implant interface, the porous surface structure provided a large region that experienced low distortional and volumetric strains, whereas the plasma-sprayed implant provided little local strain protection to the healing tissue. The strain protected region, which was within the pores of the sintered porous surface layer. corresponded to the region where the difference in the amount of mineralization between the two implant designs was the greatest. Low distortional and volumetric strains are believed to favour osteogenesis, and therefore the model results provide initial support for the hypothesis that the porous-surfaced geometry provides a local mechanical environment that favours more rapid bone formation in certain situations.

Animals↗

The role of facilitated diffusion in oxygen transport by cell-free hemoglobins: implications for the design of hemoglobin-based oxygen carriers.

We compared rates of oxygen transport in an in vitro capillary system using red blood cells (RBCs) and cell-free hemoglobins. The axial PO(2) drop down the capillary was calculated using finite-element analysis. RBCs, unmodified hemoglobin (HbA(0)), cross-linked hemoglobin (alpha alpha-Hb) and hemoglobin conjugated to polyethylene-glycol (PEG-Hb) were evaluated. According to their fractional saturation curves, PEG-Hb showed the least desaturation down the capillary, which most closely matched the RBCs; HbA(0) and alpha alpha-Hb showed much greater desaturation. A lumped diffusion parameter, K*, was calculated based on the Fick diffusion equation with a term for facilitated diffusion. The overall rates of oxygen transfer are consistent with hemoglobin diffusion rates according to the Stokes-Einstein Law and with previously measured blood pressure responses in rats. This study provides a conceptual framework for the design of a 'blood substitute' based on mimicking O(2) transport by RBCs to prevent autoregulatory changes in blood flow and pressure.

Algorithms↗

The dynamic role of buttress reconstruction after maxillectomy.

BACKGROUND: The purpose of this study was to investigate the dynamic effect of maxillary reconstruction after partial resection of the maxilla. METHODS: On a personal computer, three-dimensional maxilla models were designed based on computed tomographic data obtained from 10 edentulous skull models. Simulation surgery was performed on each model, creating 10 pairs of half-removed maxilla models and corresponding models after reconstruction with a rib. The three different patterns seen in the 10 models were termed normal maxilla, half-removed maxilla, and reconstructed maxilla. After an implant was fixed on the molar region of each model, a 300-N vertical load and a 50-N horizontal load were applied. Using finite element analysis software, the deviation and stress on each model were calculated and compared between different model patterns. RESULTS: Regarding deformity of the maxilla, when a vertical load was applied, no significant difference was observed among the three model patterns. However, a difference was observed in response to a horizontal load in that there was a tendency for deformation to occur, with that of half-removed maxilla being the greatest followed by reconstructed and normal maxilla. Regarding stresses around the implant, when the vertical and horizontal loads were applied, no significant difference was observed among the three model patterns in maximum stress around the implant. CONCLUSIONS: A buttress reconstruction is effective in increasing the stability of the maxilla against a horizontal load. However, the maximum stress around the implant in the molar region is unaffected whether or not removal or reconstruction is performed.

Computer Graphics↗

Implant-abutment interface: biomechanical study of flat top versus conical.

BACKGROUND: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage strength is maximized if the implant is given a design that minimizes the peak bone stress caused by a standardized load. Clinical studies have shown that it is possible to obtain a marginal bone level close to the crest of the implant. Different implant systems make use of different designs of the implant-abutment interface. Different implant-abutment interfaces imply that the functional load is distributed in different ways upon the implant. According to Saint-Venant's principle, this will result in different stress patterns in the marginal bone when this reaches levels close to the implant crest. PURPOSE: One aim of the study was to theoretically investigate if a conical implant-abutment interface gives rise to a changed stress pattern in the marginal bone, as compared to a flat top interface, for an axially loaded mandibular titanium implant, the neck of which is provided with retention elements giving effective interlocking with the bone. Further aims were to investigate if the way in which the axial load is distributed on the flat top and on the inner conus respectively affects the stress pattern in the marginal bone. The pertinent stress was considered to be the bone-implant interfacial shear stress. It was assumed that the marginal bone reached the level of the implant-abutment interface. METHOD: The investigation was performed by means of axisymmetric finite element analysis. RESULTS: The conical implant-abutment interface of the type studied brought about a decrease in the peak bone-implant interfacial shear stress as compared to the flat top interface of the type studied. This peak interfacial shear stress was located at the top marginal bone for the flat top implant-abutment interface whereas it was located more apically in the bone for the conical implant-abutment interface. The way in which the axial load was distributed on the flat top and on the inner conus respectively affected the peak interfacial shear stress level. CONCLUSION: The design of the implant-abutment interface has a profound effect upon the stress state in the marginal bone when this reaches the level of this interface. The implant with the conical interface can theoretically resist a larger axial load than the implant with the flat top interface.

Alveolar Process↗

Bending properties of strengthened Ti-6Al-7Nb alloy major connectors compared to Co-Cr alloy major connectors.

STATEMENT OF PROBLEM: Although Ti-6Al-7Nb alloy has several excellent mechanical properties, its poor rigidity has limited its clinical use as a material for the fabrication of a removable partial denture (RPD) major connector. PURPOSE: The purpose of this study was to develop and evaluate strengthening designs of Ti-6Al-7Nb RPD major connectors in an effort to increase rigidity. MATERIAL AND METHODS: Four strengthening designs of Ti-6Al-7Nb alloy major connectors were developed using finite element analysis modeling: wide, thick, thick at the middle, and thick at the anterior and posterior borders. The designs had similar rigidity values to a conventional Co-Cr alloy major connector, as measured by the maximum deformation when a simulated load was applied. Next, 30 Kennedy Class II maxillary RPD specimens, using 6 different major connector designs (n = 5), were fabricated. These 6 designs included Ti-6Al-7Nb alloy RPDs with 4 different strengthening designs, a Ti-6Al-7Nb alloy RPD without strengthening designs, and a conventional Co-Cr alloy RPD as a control. The rigidity of the RPDs was evaluated by measuring strains on the major connector and force on the intaglio surface of a denture base under a 30 N loading condition. The data obtained from the 6 different RPD designs were compared using a repeated measures analysis of variance and the Bonferroni correction (alpha=.05). RESULTS: The strains on the major connectors and the force on the denture bases measured from the Ti-6Al-7Nb RPD without strengthening designs were significantly larger than those of the standard Co-Cr alloy RPD. The strains measured from the 4 strengthening designs were not significantly larger than those of the Co-Cr alloy RPD. CONCLUSION: The results suggest that the strengthening designs tested may improve the rigidity of the Ti-6Al-7Nb alloy major connectors and, hence, may promote clinical application for RPDs.

Chromium Alloys↗

Vascular mechanics of the coronary artery.

UNLABELLED: This paper describes our research into the vascular mechanics of the coronary artery and plaque. The three sections describe the determination of arterial mechanical properties using intravascular ultrasound (IVUS), a constitutive relation for the arterial wall, and finite element method (FEM) models of the arterial wall and atheroma. METHODS: Inflation testing of porcine left anterior descending coronary arteries was conducted. The changes in the vessel geometry were monitored using IVUS, and intracoronary pressure was recorded using a pressure transducer. The creep and quasistatic stress/strain responses were determined. A Standard Linear Solid (SLS) was modified to reproduce the non-linear elastic behavior of the arterial wall. This Standard Non-linear Solid (SNS) was implemented into an axisymetric thick-walled cylinder numerical model. Finite element analysis models were created for five age groups and four levels of stenosis using the Pathobiological Determinants of Atherosclerosis Youth (PDAY) database. RESULTS: The arteries exhibited non-linear elastic behavior. The total tissue creep strain was epsilon creep = 0.082 +/- 0.018 mm/mm. The numerical model could reproduce both the non-linearity of the porcine data and time dependent behavior of the arterial wall found in the literature with a correlation coefficient of 0.985. Increasing age had a strong positive correlation with the shoulder stress level, (r = 0.95). The 30% stenosis had the highest shoulder stress due to the combination of a fully formed lipid pool and a thin cap. CONCLUSIONS: Studying the solid mechanics of the arterial wall and the atheroma provide important insights into the mechanisms involved in plaque rupture.

Animals↗

A conical-collared intramedullary stem can improve stress transfer and limit micromotion.

OBJECTIVE: The objective of this study was to quantify the effect of collar geometry on stress transfer and micromotion in idealized models of a cementless implant having an intramedullary stem. BACKGROUND: Intramedullary stems exist on several types of orthopaedic implants, including the femoral component of hip arthroplasties and segmental replacements used in the surgical treatment of a tumor or trauma in the diaphysis of a long bone. METHODS: Using three-dimensional finite element analysis, we compared four idealized, straight-stemmed, axisymmetric prostheses: flat-collared (0 degrees), conical-collared (30 degrees and 60 degrees), and collarless tapered (80 degrees). We simulated axial and non-axial (20 degrees oblique) loads as well as non-ingrown and ingrown interface conditions. RESULTS: Without bone ingrowth, stress transfer to bone adjacent to the collar increased with collar angle. Micromotion at the distal stem increased moderately with collar angle from 0 degrees through 60 degrees, then increased markedly from 60 degrees to 80 degrees. With simulated bony ingrowth, the effect of the collar was greatly reduced. CONCLUSIONS: The results of this study suggest that the selection of collar angle represents a tradeoff between initial stress transfer and micromotion. Stems with conical collar angles in the range of 30-60 degrees can provide increased stress transfer compared to a flat collar design and reduced micromotion compared to a collarless tapered design.

Biomechanical Phenomena↗

Unsteady viscous flow model on moving the domain through a stenotic artery.

An unsteady Navier-Stokes (N-S) solver based on the method of operator splitting and artificial compressibility has been studied for the moving boundary problem to simulate blood flow through a compliant vessel. Galerkin finite element analysis is used to discretize the governing equations. The model has been applied to a time-varying computational domain (two-dimensional tube) as a test case for validation. Consideration has been given to retaining the space conservation property. The same code is then applied to a hypothetical critical high-pressure gradient over a short length of blood vessel based on the spring and dashpot model. The governing equation for the blood vessel is based on two-dimensional dynamic thin-shell theory that takes into account the curvature of the stenotic portion of the vessel. Progressing the solution towards steady state is considered, as the main objective is to show the viability of the current technique for fluid/structure interactions. Preliminary results of the wall velocity and displacement based on steady state prediction agree well with data in the literature. Results, such as the streamlines, wall pressures and wall shear stress depict the possible progression of arterial disease.

Arterial Occlusive Diseases↗

Strains and tensile stress distribution in loaded disc-shaped ceramic specimens. An FEA study.

Disc-shaped specimens are frequently tested in order to establish an understanding of the properties of ceramic material. In this study three-dimensional finite element stress analysis has been used to investigate the loading characteristics of this shape of specimen and the effect of incorporating scratches and voids into its structure. The results indicated that stress increased as loading was carried out nearer to the centre of the specimen. The presence of cracks did not affect these stresses whereas the presence of a void resulted in a very high stress concentration.

Compressive Strength↗

Microtensile bond strength of different components of core veneered all-ceramic restorations.

OBJECTIVES: The present study aims to evaluate the core-veneer bond strength and the cohesive strength of the components of three commercial layered all-ceramic systems. Two surface treatments for the core surface finish and different veneering ceramics with different thermal expansion coefficients (TEC) were applied. The selected systems were two CAD-CAM ceramics; Cercon and Vita Mark II and one pressable system; (IPS)Empress 2 for layering technique. METHODS: Standardized core specimens were fabricated according to the manufacturer's instructions, or polished with 1200 siliconcarbide polishing paper. The core specimens were veneered with either its manufacturer's veneer or an experimental veneer with higher TEC. The obtained micro-bars were subjected to the microtensile bond strength test. The obtained data were analyzed using one and two-way ANOVA. A finite element analysis (FEA) model of the test setup was analyzed. Scanning Electron Microscopy (SEM) was carried out at the fracture surface. RESULTS: The core materials were significantly stronger than the veneering materials and the layered core-veneer specimens of which the results were statistically comparable. Polishing the core surfaces did not have an effect on the core-veneer bond strength. Experimental veneer with higher TEC resulted in massive fractures in both the core and veneering material. SEM and FEA demonstrated fracture pattern and mechanism of failure. SIGNIFICANCE: The core-veneer bond strength is one of the weakest links of layered all-ceramic restorations and has a significant role in their success. To exploit fully the high strength of zirconium oxide cores, further research work is needed to improve its bond with its corresponding veneering material.

Biocompatible Materials↗

Mucosal folding in biologic vessels.

A two-layer model is used to simulate the mechanical behavior of an airway or other biological vessel under external compressive stress or smooth muscle constriction sufficient to cause longitudinal mucosal buckling. Analytic andfinite element numerical methods are used to examine the onset of buckling. Post-buckling solutions are obtained by finite element analysis, then verified with large-scale physical model experiments. The two-layer model provides insight into how the stiffness of a vessel wall changes due to changes in the geometry and intrinsic material stiffnesses of the wall components. Specifically, it predicts that the number of mucosal folds in the buckled state is diminished most by increased thickness of the inner collagen-rich layer, and relatively little by increased thickness of the outer submucosal layer. An increase in the ratio of the inner to outer material stiffnesses causes an intermediate reduction in the number of folds. Results are cast in a simple form that can easily be used to predict buckling in a variety of vessels. The model quantitatively confirms that an increase in the thickness of the inner layer leads to a reduction in the number of mucosal folds, and further, that this can lead to increased vessel collapse at high levels of smooth muscle constriction.

Bronchi↗

Mechanobiology and joint conformity regulate endochondral ossification of sesamoids.

Sesamoid bones form by the endochondral ossification of sesamoid cartilages. This ossification process is thought to be similar to that responsible for the formation of secondary ossific nuclei in long-bone epiphyses. Sesamoids ossify much later in development than do epiphyses, however, and bone formation within sesamoids often begins by way of multiple ossific nuclei. Endochondral growth and ossification in the formation of secondary ossific nuclei have previously been correlated with distributions of the octahedral shear and hydrostatic stresses generated in vivo within cartilage anlagen. In this study, we used two-dimensional finite element analysis to predict the distributions of octahedral shear and hydrostatic stresses in an idealized model of a sesamoid cartilage subjected to in vivo loading. We examined the influence of sesamoid joint conformity. The distribution of an osteogenic stimulus was calculated with an approach similar to that used to predict epiphyseal ossification. The results suggest that, compared with conforming joints, nonconformity between the sesamoid cartilage and its articulating surface, which arises during early development, produces higher contact pressures within the sesamoid and leads to a thicker articular cartilage layer. For a nonconforming joint surface, the results suggest that ossification is favored anywhere within a broad internal region of the sesamoid, whereas a layer at the articular surface will remain cartilaginous. These findings highlight the subtle differences between ossification processes in epiphyses and sesamoids, indicating that the mechanical stress environment in sesamoids produces a diffuse stimulus leading to the onset of ossification and that the degree of joint nonconformity may influence the thickness of the articular cartilage layer.

Cartilage↗

Anchorage effect of osseointegrated vs nonosseointegrated palatal implants.

Palatal implants can be used with a transpalatal arch (TPA) connected with the second premolar to provide anchorage. The purpose of this study was to compare the anchorage effects of an osseointegrated palatal implant (OPI) with a nonosseointegrated palatal implant (NOPI), using finite element analysis. One model, which was composed of two maxillary premolars, periodontal ligament (PDL), alveolar bone, a palatal implant, palatal bone, a bracket, band, and TPA, was created on the basis of the clinical situation. The palatal implant was treated as either NOPI or OPI. The force on the premolars was investigated under three conditions: a distomesial horizontal force, a buccolingual horizontal force, and a vertical intrusive force. The PDL stress was calculated and compared with a model without an implant. The result showed that OPI could reduce PDL stress significantly. (The average stress was reduced by 14.44% for the distomesial horizontal force, 60.28% for the buccolingual horizontal force, and 17.31% for the vertical intrusive force.) The NOPI showed almost the same anchorage effect as OPI. The stress on the NOPI surface was higher than that on the OPI surface, but the stress was not high enough to result in failure of the implant. These results suggested that waiting for osseointegration might be unnecessary for an orthodontic implant.

Alveolar Process↗

Prediction of electrical impedance parameters for the simulated leg segment of an aircraft pilot under G-stress.

BACKGROUND: Blood accumulation in the lower extremities of fighter pilots has been known to induce loss of peripheral vision and consciousness. G suits and anti-G straining maneuvers applied to lower limbs do not work according to the actual status of blood accumulation. Therefore, the problem of blood accumulation in the legs requires further investigation. METHOD: The leg segment of an aircraft pilot has been modeled as a cylinder containing its anatomical structure of skin-fat layer, muscles, bones, and blood volume in the form of inner cylinders. Finite element analysis (FEA) was applied to the leg model with suitable boundary conditions. Predicted leg-segment electrical impedance (LEI) without blood accumulation has been compared with the measured experimental value using electrical impedance plethysmography (EIP). The effects of 7% blood pooling were analyzed by electrical impedance of the leg segment and its constituents by increasing the diameter of blood volume cylinder. RESULTS: The LEI has been predicted to be 46.7 omega, which corresponds well with experimental value of 46.0 omega and predicted value, being 1.58% higher. Predicted LEI was reduced to 44.2 omega during simulation of blood accumulation in FE model. The relative contributions of admittance for leg constituents fat, muscle, bones and blood volume are also found to be 2.96, 75.58, 0.33, and 11.13%, respectively. CONCLUSION: A computer simulation technique has been developed to predict electrical impedance parameters of the leg segment and its constituents with and without blood pooling. These results will be useful in further research and clinical applications for aircraft pilots under acceleration (G) stress.

Adipose Tissue↗