Cardiac output in patients with acute lower limb ischaemia of presumed embolic origin--a predictor of severity and outcome?

Cardiodynamic studies using a non-invasive computerised thoracic electrical bioimpedance (TEB) equipment were performed in 35 patients presenting with acute lower limb ischaemia of presumed embolic origin, and in 36 age-matched control patients without emboli. Patients who presented with imminent gangrene were promptly operated upon, whereas those who had less severe ischaemia were treated initially with heparin only. In the former group, cardiac output and myocardial contractility were very low on admission, while systemic vascular resistance was high. Cardiac output was further decreased when measured immediately after revascularisation, whereas it had become normal 2 days later. In patients with less severe acute ischaemia, cardiac output and myocardial contractility values on admission were similar to those of control patients, and no changes were observed after 2 days of conservative treatment. Overall, cardiac output on admission was significantly related to the simultaneously observed severity of the limb ischaemia. A low cardiac output (less than 1.7 l/min m2) on admission was found to predict severe cardiac complications (60% mortality within 10 days), whereas clinical assessment of cardiac failure on admission was poorly related to outcome. We conclude that patients with acute lower limb ischaemia of presumed embolic origin often have unrecognised poor cardiac function, which is related to the severity of the limb ischaemia and to outcome. By routine non-invasive TEB cardiodynamic measurements, high risk patients can rapidly be identified and proper treatment regimes be instituted in each individual patient.

Aged↗

Accuracy of cardiac output, oxygen uptake, and arteriovenous oxygen difference at rest, during exercise, and after vasodilator therapy in patients with severe, chronic heart failure.

Measurement of cardiac output, arteriovenous oxygen difference, and oxygen uptake in patients with heart failure may be subject to technical and biologic inaccuracies. We measured these 3 variables in 16 patients with chronic heart failure at rest and during exercise. When cardiac output was measured by thermodilution and compared with values calculated by the Fick principle, there was a significant correlation at rest (r = 0.91, p less than 0.001) and at exercise (r = 0.93, p less than 0.001). When the arteriovenous oxygen difference was measured by spectrophotometry of arterial and mixed venous samples and compared with values calculated by the Fick principle, there was a significant correlation at rest (r = 0.80, p less than 0.01) and at exercise (r = 0.76, p less than 0.01). When oxygen uptake was measured from expired gas analysis and compared with values calculated by the Fick principle, there was a significant correlation at rest (r = 0.84, p less than 0.01) and at exercise (r = 0.94, p less than 0.001). In addition, 10 patients received vasodilator treatment which increased cardiac output and decreased the arteriovenous oxygen difference at rest and exercise. There was no significant difference between measured and calculated values for the 3 variables under those additional conditions. It is concluded that despite technical and biologic difficulties, cardiac output, arteriovenous oxygen difference, and oxygen uptake, when calculated from Fick's principle, yield results equivalent to direct measurement.

Adult↗

Oxygen uptake and cardiac output at rest and during exercise after surgery for coarctation of the aorta.

Oxygen uptake and cardiac output at rest and during exercise were studied in 19 men operated on for coarctation of the aorta during childhood. Their aerobic capacity and their maximal values for cardiac output, stroke volume and arteriovenous oxygen difference were normal. No differences were found regarding these variables between hypertensive and normotensive subjects. Thus, there was no sign of failure of the left ventricle even in patients with high blood pressure during exercise. Whether the normal arteriovenous oxygen difference indicates a normal distribution of the cardiac output cannot be settled from the present data.

Adolescent↗

Development and in vitro validation of a device for measuring non-shunt cardiac output by nitrous oxide throughflow.

A system has been developed for measuring non-shunt cardiac output by the throughflow technique, using nitrous oxide in patients undergoing general anaesthesia. The throughflow measurement technique is a non-invasive method based on inert gas throughflow theory. In vitro validation of the measurement system was performed using a lung gas exchange simulator. The accuracy and precision of the throughflow measurement system was assessed by comparing measured and target values for five simulated values of non-shunt cardiac output, from 2.88 to 9.86 l min(-1). This showed an overall mean bias of -0.031 min(-1) (range -0.00 to -0.101 min(-1)), with a mean coefficient of variation of the difference of 1.39% (1.20-1.93%). These results indicate that the measurement system is suitable for monitoring the non-shunt cardiac output in patients undergoing general anaesthesia using nitrous oxide throughflow.

Anesthetics, Inhalation↗

Measurement accuracy of cardiac output in humans: indicator-dilution technique versus geometric analysis by ultrafast computed tomography.

OBJECTIVES: The aim of this study was to evaluate measurement accuracy of cardiac output in humans by comparing the indicator-dilution technique with geometric analysis by ultrafast computed tomography. BACKGROUND: Ultrafast computed tomography can be used to measure cardiac output by two methods. First, by scanning to obtain end-systolic and end-diastolic short-axis images of the ventricular cavities at sequential tomographic levels, the stroke volume and therefore the cardiac output can be calculated. Second, indicator-dilution theory (the Stewart-Hamilton equation) can be applied to measurements of the concentration of radiographic contrast in the blood pool after a bolus injection. The latter method has not been validated in humans. METHODS: The accuracy of the geometric method itself was first established by comparing left and right ventricular stroke volumes in 29 patients without valvular regurgitation or an intracardiac shunt, whose left and right ventricular stroke volumes should have been identical (group A). In a subset of 17 patients, the geometric method was compared with the indicator-dilution method (group B). RESULTS: Geometric analysis showed that the mean difference between left and right ventricular stroke volume was 1.8 +/- 7.3 ml, with a percentage SD of the differences of 9.3% (r = 0.9). Comparison wih indicator dilution-calculated cardiac output showed a mean difference of 0.079 +/- 1.22 liters/min, with a percent SD of the differences of 23.7% (r = 0.6). There was no improvement in this comparison with individual calibration of the scanner for each patient. CONCLUSIONS: The disparity found between data obtained with the geometric and indicator-dilution methods may be a result of the hemodynamic effects of contrast medium or it may suggest the possibility that some assumptions of indicator-dilution theory are not valid.

Adult↗

Effect of background serum lithium concentrations on the accuracy of lithium dilution cardiac output determination in dogs.

OBJECTIVES: To assess the effect of increasing serum lithium concentrations on lithium dilution cardiac output (LiDCO) determination and to determine the ability to predict the serum lithium concentration from the cumulative lithium chloride dosage. ANIMALS: 10 dogs (7 males, 3 females). PROCEDURE: Cardiac output (CO) was determined in anesthetized dogs by measuring LiDCO and thermodilution cardiac output (TDCO). The effect of the serum lithium concentration on LiDCO was assessed by observing the agreement between TDCO and LiDCO at various serum lithium concentrations. Also, cumulative lithium chloride dosage was compared with the corresponding serum lithium concentrations. RESULTS: 44 paired observations were used. The linear regression analysis for the effect of the serum lithium concentration on the agreement between TDCO and LiDCO revealed a slope of -1.530 (95% confidence interval [CI], -2.388 to -0.671) and a y-intercept of 0.011 (r2 = 0.235). The linear regression analysis for the effect of the cumulative lithium chloride dosage on the serum lithium concentration revealed a slope of 2.291 (95% CI, 2.153 to 2.429) and a y-intercept of 0.008 (r2 = 0.969). CONCLUSIONS AND CLINICAL RELEVANCE: The LiDCO measurement increased slightly as the serum lithium concentration increased. This error was not clinically relevant and was minimal at a serum lithium concentration of 0.1 mmol/L and modest at a concentration of 0.4 mmol/L. The serum lithium concentration can be reliably predicted from the cumulative lithium dosage if lithium chloride is administered often within a short period.

Animals↗

Phase-related changes in right ventricular cardiac output under volume-controlled mechanical ventilation with positive end-expiratory pressure.

OBJECTIVE: To examine determinants of right ventricular function throughout the ventilatory cycle under volume-controlled mechanical ventilation with various positive end-expiratory pressure (PEEP) stages. DESIGN: Prospective observational animal pilot study. SETTING: Animal research laboratory at a university hospital. SUBJECTS: Eight healthy swine under volume- controlled mechanical ventilation. INTERVENTIONS: Flow probes were implanted in eight swine in order to continuously measure blood flow in the pulmonary artery and inferior vena cava. After a recovery phase of 14 days, the swine were subjected to various PEEP stages (0, 5, 10 cm H2O) during volume-controlled positive pressure ventilation. MEASUREMENTS AND MAIN RESULTS: Continuous flow measurement took place in the pulmonary artery and inferior vena cava. Data on standard hemodynamic parameters were additionally acquired. Respiration-phase-specific analysis of right ventricular cardiac output and of additional hemodynamic function parameters followed, after calculation of mean values throughout five respiration cycles. PEEP at 5 cm H2O led to significant decreases in inferior vena cava flow (4.1%), and in right ventricular cardiac output (5.2%); the respective decreases at PEEP 10 cm H2O were 13.9% and 18.3%. In the inspiration phase at PEEP 10 cm H2O, results revealed an overproportionally pronounced decrease in comparison with the expiration phase in inferior vena cava flow (-24.6% vs. -10%) and right ventricular cardiac output (-35% vs. -13.5%). This phenomenon is presumably caused by a PEEP-related increase in mean airway pressure by the amount of 10.7 cm H2O in inspiration. CONCLUSIONS: Increases in PEEP during volume-controlled mechanical ventilation leads to respiration-phase-specific reduction of right ventricular cardiac output, with a significantly pronounced decrease during the inspiration phase. This decrease in cardiac output should be taken into particular consideration for patients with already critically reduced cardiac output.

Airway Resistance↗

Hypotension during cemented arthroplasty. Relationship to cardiac output and fat embolism.

An episode of hypotension is common during cemented joint replacement, and has been associated with circulatory collapse and sudden death. We studied the mechanism of hypotension in two groups of six dogs after simulated bilateral cemented arthroplasty. In one group, with no lavage, the insertion of cement and prosthesis was followed by severe hypotension, elevated pulmonary artery pressure, decreased systemic vascular resistance and a 21% reduction in cardiac output. In the other group, pulsatile intramedullary lavage was performed before the simulated arthroplasties. Hypotension was less, and although systemic vascular resistance decreased, the cardiac output did not change. The severity of the hypotension, the decrease in cardiac output and an increase in prostaglandin metabolites were related to the magnitude of pulmonary fat embolism. Pulsatile lavage prevents much of this fat embolism, and hence the decrease in cardiac output. The relatively mild hypotension after lavage was secondary to transient vasodilation, which may accentuate the hypotension caused by the decreased cardiac output due to a large embolic fat load. We make recommendations for the prevention and management of hypotension during cemented arthroplasty.

Animals↗

Simultaneous measurements of cardiac output by thermodilution, esophageal Doppler, and electrical impedance in anesthetized patients.

Simultaneous intraoperative measurements of cardiac output were obtained in nine patients with transesophageal Doppler, transthoracic impedance, and pulmonary artery thermodilution techniques to evaluate the utility of the noninvasive methods. Pairs of noninvasive and thermodilution measurements were obtained 25 times with transesophageal Doppler and 58 times with transthoracic impedance. Correlation of the noninvasive measurements with thermodilution was poor, with r = 0.43 for transthoracic impedance and r = .68 for transesophageal Doppler. The average difference between the noninvasive and the thermodilution values was -0.4 +/- 1.4 L/min (mean +/- SD) and -0.1 +/- 1.6 L/min for impedance and Doppler, respectively. Changes in cardiac output at sequential time points as measured by thermodilution were predicted with 95% confidence only when a change of >4 L/min was observed by transesophageal Doppler or >8 L/min was observed by transthoracic impedance. Therefore, it is concluded that neither noninvasive technique reliably estimated cardiac output as determined by thermodilution, and neither tracked trends.

Cardiac Output↗

Noninvasive estimation of cardiac output.

A noninvasive method of measuring cardiac output is described. The method uses adaptive aorta models in conjunction with femoral and carotid pulse contour waveform measurements to calculate aortic flow. Results are presented from measurements on dogs using internal pressure recordings made with fluid-filled catheters and compared with electromagnetic flow measurements taken in the ascending aorta. Preliminary results using external pulse measurements on patients are also presented and compared with thermal dilution measurements.

Animals↗

[Effects of cardiac output on PETCO2 and PaCO2 during combined inhalational-epidural anesthesia].

We investigated the effects of cardiac output on PETCO2 in anesthetized patients. We studied 8 adult patients undergoing long-lasting lower abdominal surgery. Anesthesia was maintained with epidural combined with inhalational anesthesia. The minute ventilation volume was kept constant at 10 ml.kg-1 x 10 cycles.min-1. PETCO2, PaCO2, and cardiac index, (CI) by thermodilution method were measured simultaneously. PaCO2 was corrected for body temperature for comparison with PETCO2. Approximate value of alveolar dead space to tidal volume ratio was calculated as VD/ VTalv = (PaCO2-PETCO2)/PaCO2. The measurements were repeated every 10 to 20 minutes under the steady body temperature. One hundred and six sets of data were obtained from these patients. PETCO2 as well as PaCO2 correlated positively with CI, while VD/VTalv did not correlate with CI. PETCO2 correlated positively with PaCO2, while it did not correlate with VD/VTa1v. When examined in individual patients, PETCO2 correlated positively with CI in 7 patients. PaCO2 correlated positively with CI in 6 patients, while VD/VTa1v correlated negatively with CI only in 2 patients, in whom CI showed a large fluctuation. PaCO2 correlated positively with PETCO2 in 8 patient, while VD/VTa1v correlated negatively with PETCO2 only in 1 patient. By multiple regression analysis, VD/VTa1v change accounted for only 20.0 +/- 15.3% of PETCO2 change, while PACO2 or PaCO2 change accounted for 79.3 +/- 16.7%. Decreased CI was associated with a decrease in oxygen uptake (VO2), and PaCO2 correlated positively with VO2. Decreased CI was also associated with an increase in VA/Q, and PaCO2 correlated negatively with VA/Q. Thus, PETCO2 decreased with decreasing cardiac output. A decrease in PACO2 explained the decrease in PETCO2 better than an increase in VD/VT did. Decreased cardiac output caused hypocapnia through decreased CO2 production and/or increased ventilation to perfusion ratio i.e. relative hyperventilation.

Adult↗

Cardiac output changes during experimental renal hypertension in the rabbit.

1. The haemodynamic changes during the development of hypertension in rabbits have been studied for 1 week before and 4-5 weeks after sham-operation (thirteen rabbits) or bilateral renal cellophan wrapping (thirteen rabbits), Doppler flowmeters being used to measure cardiac output. 2. There was a significant but transient rise in cardiac output on post-operative day 4 in six of thirteen sham-operated rabbits and six of thirteen renal-wrap rabbits before development of hypertension. Both groups showed the same rise in mean cardiac output of 10%. The reise in cardiac output was more transient than in other species, and was not essential for subsequent development of hypertension.

Animals↗

Enhanced cardiac thermal dilution measurement of cardiac output, volumes, regurgitation, valve effective diameters, ventricular power and efficiency -- Feasibility analysis using digital simulation.

Cardiac output is measured by the thermal dilution method which uses a quadruple lumen catheter, with a thermistor on the tip, through the right atrium, right ventricle and into the pulmonary artery. Cold saline is injected into the right atrium and the resulting pulmonary artery temperature profile is integrated. The same procedure performed with three thermistors and three pressure sensors located on the catheter to measure temperature and pressure in the atrium, ventricle and artery respectively will produce a set of temperature and pressure curves with shapes determined by injectate temperature, injectate volume, heart rate, systolic time interval, body temperature, cardiac output, volumes, flow rates and valve openings. A digital computer program has been developed to optimize the fit of a lumped parameter model to the thermodilution curves in order to determine heart rate, systolic time as a fraction of cardiac cycle, right atrial systolic and diastolic volumes, ventricular systolic and diastolic volumes, cardiac output, inflow valve forward and reverse flow rates and effective diameters, outflow valve forward and reverse flow rates and effective diameters, ventricular power and efficiency. The program has been tested over a range of operating conditions including noise in the temperature and pressure signals, randomly varying heart rate and cardiac cycle. All of the data for the tests were produced by a digital computer simulation of a pulsatile artificial heart. The results of these tests indicate that the enhanced thermal dilution analysis method is feasible.

Cardiac Output↗

Relation of various degrees of body mass index in patients with systemic hypertension to left ventricular mass, cardiac output, and peripheral resistance (The Hypertension Genetic Epidemiology Network Study).

The impact of different methods of indexation of left ventricular (LV) mass and systemic hemodynamic variables on prevalences and correlates of cardiovascular abnormalities in relation to level of obesity in populations remains unclear. We evaluated 1,672 participants in the Hypertension Genetic Epidemiology Network Study to investigate the relations of overweight and level of obesity to LV mass and prevalences of LV hypertrophy, abnormal cardiac output, and peripheral resistance detected using different indexations for body size. In our study population, 1,577 subjects were clinically healthy nondiabetic hypertensive and 95 were normotensive normal-weight nondiabetic reference subjects. Fat-free mass (FFM) did not differ between the reference group and the normal-weight hypertensive subjects, and increased with overweight. In hypertensive subjects, LV mass and cardiac output increased and total peripheral resistance decreased with overweight. Indexation of LV mass for FFM or body surface area (BSA) resulted in no difference or even lower prevalence of LV hypertrophy in severely obese compared with normal-weight hypertensive subjects. In contrast, indexation of LV mass for height(2.7) identified an increased prevalence of LV hypertrophy with overweight and obesity. Absolute cardiac output increased and total peripheral resistance decreased with overweight. Prevalence of elevated cardiac output indexed for height(1.83) increased and for elevated total peripheral resistance-height(1.83) index decreased with greater overweight, whereas opposite trends were seen when cardiac output and total peripheral resistance were indexed for BSA or FFM. Thus, in hypertensive subjects, FFM increases with overweight and is directly related to LV mass, stroke volume, and cardiac output, and inversely related to total peripheral resistance. Indexations of LV mass and systemic hemodynamics for FFM or BSA obscured associations of LV hypertrophy and abnormal cardiac and total peripheral resistance indexes with overweight, whereas LV mass/height(2,7), cardiac output/height(1.83), and total peripheral resistance-height(1.83) detected significant preclinical cardiovascular abnormalities with obesity.

Body Mass Index↗

Measurements of cardiac output of an isolated heart using a specially designed turbine.

Cardiac output is one of the important parameters used in evaluation of heart function. A turbine which works on mechanical principles was designed. It is also suitable for cardiac output measurements on isolated pig hearts in cases where some other equipment is not, like on doppler effect based transducers. The basic principle of measuring liquid flow through a turbine is based on measurement of the time that elapses when the rotor rotates by one degree. For this purpose, the rotor is fitted with transparent foil with a ring of 360 short black lines printed close to its circumference. Two infrared light-emitting diodes are mounted on one side of the foil and two photo-transistors, used as sensors of the transmitted infrared light, are mounted on the other. Voltage-regulated output ranging from 0 to +/- 2048 V at one revolution per second gives 500 mV at the output (changeable by programming), calculating time 2 ms, 1 mV resolution (11 bits), with an external power supply of 5 V. The turbine showed a linear response at a continuous saline flow up to 3000 ml min-1 at pressure loads of between 20 and 220 cm H2O. Pressure drop across the turbine depends on the volume flow and was 1 mm Hg at 100 ml min-1 and 3 mm Hg at 7000 ml min-1. A rotating movement 1.25 x 10(-4) kg m2 s-1 was calculated. The lowest volume change of a bolus of saline solution, detected by the turbine, was 1.6 ml.

Animals↗

Measurement of the cardiac output in small animals by thermodilution.

Cardiac output (CO) measurements based on indicator dilution, microspheres, thermodilution and ultrasonic sensors are not suitable for small animals, because of limited blood volume, high heart rates and small caliber vessels that do not allow probe placement within the heart. We developed a modified thermodilution method to measure CO in awake animals weighing less than 100 g. Under anesthesia, the animal is instrumented with a jugular vein catheter placed proximal to the subclavian vein and a temperature probe in the carotid artery with the thermocouple positioned at the aortic arch. Two days after implantation, room temperature saline is injected (150 microl) into the jugular catheter and the temperature change recorded. This system uses the temperature probe as a digital feedback control: (1) to minimize recirculation error; (2) to adjust baseline temperature, thereby increasing sensitivity to small changes in temperature; and (3) to stabilize animal core temperature. The system was calibrated using a laboratory bench model with anatomically scaled components. CO was measured (n=29) in 16 hamsters (65-115 g), and was linearly related to body weight. Cardiac index (CI=CO/weight) was 197.0 +/- 18.8 (ml/min)/kg. Repeated measurements were made. This technique allows correlating systemic flow changes to be correlated to those measured in the microcirculation of window chamber preparations.

Animals↗

Radionuclide methods for cardiac output determination.

For repeated determinations of cardiac output, radionuclides have provided a safe, reliable and minimally invasive approach. The techniques used are (1) the first-pass dilution method and (2) the derivation of stroke volume from end-diastolic and end-systolic ventricular volumes. Each of the two techniques offers specific advantages, thus, both may be used clinically according to the type of evaluation that is required. Their development has been helped by the availability of adequate radiopharmaceuticals as well as highly efficient precordial detection devices, computer systems, and data handling 'software'. The associated patient exposure to radioactivity has not precluded clinical application because of the small doses used and the protective measures applied.

Algorithms↗

Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy.

In the last decade, an inexpensive and simple noninvasive method (i.e., transthoracic electrical bioimpedance cardiography, has been tested in healthy subjects and patients with various heart disease for measuring stroke volume and cardiac output at rest and/or during exercise. However, the results are still controversial, especially when measurements are obtained during exercise and data on reproducibility during exercise are lacking. Twenty-five consecutive patients (20 men and 5 women, mean age 48 +/- 9 years) in sinus rhythm with documented coronary artery disease and a previous myocardial infarct were studied. Patients were divided into 2 groups. Group A had ischemic cardiomyopathy, characterized by left ventricular (LV) enlargement and LV ejection fraction depression (35 +/- 8%). Group B had normal LV dimensions and ejection fraction (62 +/- 9%). After a familiarization study, all patients underwent an exercise test with gas exchange analysis and hemodynamic measurements. Stroke volume and cardiac output were simultaneously obtained at rest and at the end of each work rate stage with 3 methods: impedance, thermodilution, and direct Fick. Group A reached a lower peak oxygen uptake (56%), peak work load (60%), and peak systolic blood pressure (69%) than group B. Cardiac output and stroke volume were significantly greater at submaximal and peak exercise in group B than in group A (p < 0.0001). There were no significant differences in stroke volume and cardiac output in the 3 techniques at any matched work rate. There was no significant difference between measurements obtained by 2 experienced observers or between those obtained on 2 exercise tests performed on 2 different days. These results demonstrate that impedance cardiography is a noninvasive, simple, accurate, and reproducible method of measurement of cardiac output and stroke volume over a wide range of workloads.

Cardiac Catheterization↗