Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Generation of free radicals and electrochemiluminescence from simple aromatic molecules in aqueous solutions.

Oxide-covered aluminium electrodes were used to demonstrate that aromatic compounds, such as the simple derivatives of benzene, can be electrochemically excited at cathodically pulse-polarized conductor/insulator/electrolyte (C/I/E) tunnel junction electrodes (e.g. oxide-covered aluminium electrodes). The primary cathodic process at these electrodes was a tunnel emission of hot electrons into an aqueous electrolyte solution. Fluorescence (FL) and electrochemiluminescence (ECL) spectra were compared and the dependence of the electrochemiluminescence on the concentrations of benzene, toluene, phenol, p-cresol and aniline were measured and detailed mechanisms for the present electrochemiluminescence are proposed.

Aluminum↗

Locally Addressable Electrochemical Patterning Technique (LAEPT) applied to poly(L-lysine)-graft-poly(ethylene glycol) adlayers on titanium and silicon oxide surfaces.

The protein-resistant polycationic graft polymer, poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG), was uniformly adsorbed onto a homogenous titanium surface and subsequently subjected to a direct current (dc) voltage. Under the influence of an ascending cathodic and anodic potential, there was a steady and gradual loss of PLL-g-PEG from the conductive titanium surface while no desorption was observed on the insulating silicon oxide substrates. We have implemented this difference in the electrochemical response of PLL-g-PEG on conductive titanium and insulating silicon oxide regions as a biosensing platform for the controlled surface functionalization of the titanium areas while maintaining a protein-resistant background on the silicon oxide regions. A silicon-based substrate was micropatterned into alternating stripes of conductive titanium and insulating silicon oxide with subsequent PLL-g-PEG adsorption onto its surfaces. The surface modified substrate was then subjected to +1800 mV (referenced to the silver electrode). It was observed that the potentiostatic action removed the PLL-g-PEG from the titanium stripes without inducing any polyelectrolyte loss from the silicon oxide regions. Time-of-flight secondary ions mass spectroscopy and fluorescence microscopy qualitatively confirmed the PLL-g-PEG retention on the silicon oxide stripes and its absence on the titanium region. This method, known as "Locally Addressable Electrochemical Patterning Technique" (LAEPT), offers great prospects for biomedical and biosensing applications. In an attempt to elucidate the desorption mechanism of PLL-g-PEG in the presence of an electric field on titanium surface, we have conducted electrochemical impedance spectroscopy experiments on bare titanium substrates. The results showed that electrochemical transformations occurred within the titanium oxide layer; its impedance and polarization resistance were found to decrease steadily upon both cathodic and anodic polarization resulting in the polyelectrolyte desorption from the titanium surface.

Biosensing Techniques↗

A low-cost biofuel cell with pH-dependent power output based on porous carbon as matrix.

A glucose/O2 biofuel cell (BFC) possessing a pH-dependent power output was fabricated by taking porous carbon (PC) as the matrix to load glucose oxidase or fungi laccase as the catalysts. The electrolytes in the anode and cathode compartments contain ferrocene monocarboxylic acid and 2,2'-azino-bis-(3-ethylbenzthiazoline-6-sulfonic acid) diammonium salt as the mediators, respectively. The power of the BFC was enhanced significantly by using PC as the matrix, rather than glassy carbon electrode. Additionally, the power output of the BFC decreases as the pH of the solution increases from 4.0 to 7.0, which provides a simple and efficient method to achieve the required power output. More importantly, the BFC can operate at pH 6.0, and even at pH 7.0, which overcomes the requirement for cathode solutions of pH<5.0 when using fungi laccase as a catalyst. Operation of the BFC at neutral pH may provide a means to power medical devices implanted in physiological systems. The facile and low-cost fabrication of this BFC may enable its development for other applications.

Carbon↗

Electrochromic hysteresis performance of a prussian blue film arising from electron-transfer control by a tris(2,2'-bipyridine)ruthenium(II)-doped WO(3) film as studied by a spectrocyclic voltammetry technique.

A [Ru(bpy)(3)](2+) (bpy=2,2'-bipyridine)-doped WO(3) film was prepared as a base layer on a substrate by cathodic electrodeposition from a colloidal triad solution containing peroxotungstic acid (PTA), [Ru(bpy)(3)](2+), and poly(sodium 4-styrenesulfonate) (PSS). A Prussian blue (PB; Fe(II)-Fe(III)) film was cathodically electrodeposited on the [Ru(bpy)(3)](2+)-doped WO(3) film or neat WO(3) film from an aqueous Berlin brown (BB; Fe(III)-Fe(III)) colloid solution to yield a [Ru(bpy)(3)](2+)-doped WO(3)/PB bilayer film or WO(3)/PB bilayer film. For the spectrocyclic voltammogram (SCV) of the WO(3)/PB film, a redox response of Prussian white (PW; Fe(II)-Fe(II))/PB was observed at 0.11 V, however, further oxidation of PB to BB was not allowed by the interfacial n-type Schottky barrier between the WO(3) and PB layers. For the [Ru(bpy)(3)](2+)-doped WO(3)/PB film, any electrochemical response assigned to the redox of PB was not observed in the cyclic voltammogram, however, the in situ absorption spectral change recorded simultaneously showed the significant redox reactions based on PB. The SCV revealed that PW on the [Ru(bpy)(3)](2+)-doped WO(3) film is completely oxidized to PB by a geared reaction of Ru(II)/Ru(III) at 1.05 V, and that 32 % of PB formed is further oxidized to BB by the same geared reaction in the potential scan to 1.5 V. PB was completely re-reduced to PW by a geared reaction of H(x)WO(3)/WO(3) at -0.5 V in the reductive potential scan. These geared electrochemical reactions produced an electrochromic hysteresis performance of the PB film layered on the [Ru(bpy)(3)](2+)-doped WO(3) film.

Journal Article↗

OLED and PLED devices employing electrogenerated, intramolecular charge-transfer fluorescence.

The light generating mechanism of a series of light emitting diodes with electron donor-bridge-acceptor systems (D-b-A) as the emitting species was examined by constructing model diodes based on small organic molecules (OLEDs) as well as on molecularly doped electroactive (poly-N-vinylcarbazole, PVK) and insulating (polystyrene, PS) polymers (PLEDs). The direct electrogeneration of an intramolecular charge-transfer (CT) fluorescence of the donor-bridge-acceptor systems occurred readily in OLED devices with a D-b-A system as the emissive layer. In diodes with PS as the host matrix, hole-injection and electron-injection occurred directly in the D-b-A molecules residing close to the anode and the cathode, respectively. In the PVK diodes, hole-injection occurred primarily into PVK and the positive charge carrier was subsequently trapped on the D-b-A molecule, whereas electron-injection at the cathode side occurred directly into the D-b-A molecules. Charge-hopping between neighboring molecules then occurred until a hole and electron resided on the same molecule, which is equivalent to the formation of the CT excited state, and which finally relaxed by intramolecular charge recombination under the emission of CT fluorescence.

Journal Article↗

Properties of thin-rod immobilized pH gradients.

Immobilized pH gradient gel rods, 1.5 mm in diameter, were cast with a manifold connected to high-precision burettes. The reproducibility of gel length was ca. 1.7 mm. The average standard deviation sigma x for spot position was 2 mm after one-dimensional and 5.8 mm after two-dimensional runs. In order to bring to completion the elution of the salt fronts into the electrode compartments, carrier ampholytes had to be included in the gel formulation at concentrations of at least 0.5-1%, depending on the pH range. The presence of carrier ampholytes, however, was troublesome in two respects: the gel tended to shrink and the cathodic bands drifted with time. Ionic components in the sample were tolerated up to the following concentrations: NaCl 8 mumoles, sodium dodecyl sulfate 10 micrograms per tube. In presence of non-ionic detergents, the gels moved as a whole towards the cathode.

Ampholyte Mixtures↗

Western blotting of basic proteins after nondenaturing electrophoresis in acid conditions using the PhastSystem.

Electroblotting of basic proteins was performed from minigels after electrophoresis, under nondenaturing acidic conditions, by using the automated PhastSystem. Depending on the molecular masses of the proteins to be studied, various precast gel media were chosen. The transfer membranes with various types (nitrocellulose and polyvinylidene difluoride) and pore sizes (0.45 and 0.2 micron) were chosen accordingly. For the semidry electric transfer, a simple, discontinuous two-buffer system was used. The anode solution contained 0.3 M Tris, pH 10.4, and the cathode solution, 40 mM 6-amino-n-hexanoic acid, pH 7.6, with 20% v/v methanol each. The addition of 0.1% sodium dodecyl sulfate (SDS) in the cathode solution facilitated the elution of proteins from the gels and directed the migration of the negative SDS-protein complexes towards the anode membranes. The transfer conditions following native polyacrylamide gel electrophoresis allowed the visualization of basic proteins, with molecular weights ranging from 29,000 to 5,000, for which isoforms could be resolved and which retained their biological properties.

Blotting, Western↗

An isoelectrically trapped enzyme reactor operating in an electric field.

Membrane enzyme reactors constitute an attempt at integrating catalytic conversion, product separation and/or concentration and catalyst recovery into a single operation. Whereas conventional membrane reactors confine an enzyme, in a free form, to one side of a membrane by size exclusion, electrostatic repulsion, or physical or chemical immobilization onto an intermediate support (gel, liposome), the membrane reactor here described is shown to operate under an entirely new principle: enzyme confinement into an isoelectric trap located in a multicompartment electrolyzer operating in an electric field. Two isoelectric membranes, having pI values encompassing both the enzyme pI and the pH of its optimum of activity, act by continuously titrating the enzyme trapped inside, thus preventing it from escaping the reaction chamber. Charged products generated by the enzyme catalysis are continuously electrophoretically transported away from the reaction chamber and collected into other chambers stacked either towards the cathodic or anodic sides. In a urease reactor, ammonia is continuously harvested towards the cathode, thus allowing >95% substrate consumption with maintenance of enzyme integrity over much longer time periods than in a batch reactor. In a trypsin reactor, casein is digested and biologically active peptides are continuously harvested in a pure form into appropriate isoelectric traps. In a third example, pure D-phenylglycine is produced from a racemate mixture, via an acylation reaction onto a cosubstrate (the ester methyl-4-hydroxyphenyl acetate), brought about by the enzyme penicillin G acylase.

Caseins↗

Preparative-scale, recirculating, pH-biased binary isoelectric trapping separations.

In order to improve the production rates and lower the specific electrophoretic energy consumption values in preparative-scale, recirculating, binary isoelectric trapping separations, we propose to add an auxiliary isoelectric agent to the solution in the anodic separation compartment and another to the solution in the cathodic separation compartment to implement pH-biased isoelectric trapping. The auxiliary isoelectric agents are selected such that they are trapped in the respective anodic and cathodic separation compartments and also, have isoelectric point (pI) values that are different from the pI values of the analytes of interest. By proper selection of the auxiliary isoelectric agents and their concentrations, the analytes of interest can be kept in nonisoelectric, charged state during the entire course of the preparative-scale, recirculating, binary isoelectric trapping separation. This results in higher electrophoretic mobilities and solubilities for the analytes than in their isoelectric or near-isoelectric states, and leads to faster binary isoelectric trapping separations.

Animals↗

Alkali-stable high-pI isoelectric membranes for isoelectric trapping separations.

Alkali-stable, high-pI isoelectric membranes have been synthesized from quaternary ammonium derivatives of cyclodextrins and poly(vinyl alcohol), and bifunctional cross-linkers, such as glycerol-1,3-diglycidyl ether. The new, high-pI isoelectric membranes were successfully applied as cathodic membranes in isoelectric trapping separations in place of the hydrolytically more labile, polyacrylamide-based cathodic isoelectric membranes, and permitted the use of catholytes as alkaline as 1 M NaOH. The new high-pI isoelectric membranes have shown excellent mechanical stability, low electric resistance and long life times, even when subjected to electrophoresis with current densities as high as 80 mA/cm2.

Cross-Linking Reagents↗

Simultaneous separation of fifteen approved protease and reverse transcriptase inhibitors for human immunodeficiency virus therapy by capillary electrophoresis.

In the present investigation, a novel approach towards a complete separation of all 15 protease and reverse transcriptase inhibitors which are currently approved for use in highly active antiretroviral therapy in a single analytical run is presented. The developed method employs an acidic background electrolyte with sodium polyanethol sulfonate (SPAS) as polyanionic electroosmotic flow (EOF) modifier to establish a strong cathodic EOF, sodium dodecyl sulfate (SDS) as pseudostationary selector, and acetonitrile and ethanol as organic modifiers. Separation of the analytes is based on two different mechanisms. The more basic analytes are protonated at the prevailing pH conditions and thus migrate in front of the cathodic EOF, whereas the less basic and neutral analytes interact with the SDS and are retained after the EOF. By optimizing electrolyte pH, the amount of solvents and SDS concentrations in the background electrolyte it is possible to completely separate all compounds of interest.

Electrophoresis, Capillary↗

Formation of a resistive region at the anode end in DNA capillary electrophoresis.

We have studied the formation of a resistive region in the capillary during DNA separation. This effect is caused by an unequal change in the mobilities of cations and anions at the interface between the running buffer solution and the capillary. We studied the motion of the resistive region boundary by sequential removal of portions of the affected capillary end. We found that in the process of developing the resistive region the distribution of the electric fields in the capillary changes from uniform to extremely nonuniform, with a very high field (above 1 MV/cm) in the resistive region and a reduced field (80 V/cm) in the rest of the capillary. Though theoretically a resistive region may appear either at the anode (detection) or the cathode (injection) end of the capillary, all previous publications report the formation of the resistive region at the cathode side. In our experiments, however, the anomalous region is formed at the anode. Thus, the separated DNA peaks move towards the slowly progressing resistive region. Our results indicate that the DNA is stopped at the boundary and does not enter the region. When the resistive region is clipped off the peak motion resumes. This suggests that there exists a potential barrier at the resistive layer boundary that prevents the drift of the peaks towards the anode. The formation of the resistive region interferes with a normal separation process causing a gradual decrease of the capillary current and the deceleration and eventual quenching of the peak motion. For the ABI chemistry, we experimented with adding polymers to the electrode buffer to equate the transference numbers for anions and cations, and found the conditions at which this effect is completely eliminated.

Buffers↗

Perspective on concentration polarization effects in electrochromatographic separations.

This work illustrates the appearance and electrohydrodynamic consequences of concentration polarization in the particulate and monolithic fixed beds used in capillary electrochromatography and related electrical-field assisted processes. Key property of most porous materials is the co-existence of bulk, quasi-electroneutral macroporous regions and mesoporous compartments which are ion-permselective (due to electrical double-layer overlap) causing different transport numbers for co-ionic and counterionic species, e.g., background electrolyte components, or the analytes. For a cathodic electroosmotic flow the (cation) permselectivity, together with diffusive and electrokinetic transport induces depleted and enriched concentration polarization zones at the anodic and cathodic interfaces, respectively, in dependence of the mobile phase ionic strength and applied electrical fields. At high field strength a secondary, nonequilibrium electrical double layer may be created in the depleted concentration polarization zones of a material stimulating electroosmosis of the second kind. The potential of this induced-charge electroosmosis with respect to nonlinear flow velocities and electrokinetic instability mixing (basically destroying the concentration polarization zones) is analyzed in view of the pore space morphology in random-close packings of spherical-shaped, porous particles and hierarchically structured monoliths. Possible applications based on a fine-tuning of the illustrated effects emerge for microfluidic pumping and mixing, or the intensification of sample recovery in adsorption processes. With this perspective we want to focus the attention on concentration polarization in electrochromatographic systems by presenting and discussing original data acquired on relevant microscopic as well as macroscopic scales, and point towards the importance of related effects in colloid and membrane science.*

Chromatography↗

Microchip electrophoretic protein separation using electroosmotic flow induced by dynamic sodium dodecyl sulfate-coating of uncoated plastic chips.

Separation of sodium dodecyl sulfate (SDS)-protein complexes is difficult on plastic microchips due to protein adsorption onto the wall. In this paper, we elucidated the reasons for the difficulties in separating SDS-protein complexes on plastic microchips, and we then demonstrated an effective method for separating proteins using polymethyl methacrylate (PMMA) microchips. Separation difficulties were found to be dependent on adsorption of SDS onto the hydrophobic surface of the channel, by which cathodic electroosmotic flow (EOF; reversed flow) was generated. Our developed method effectively utilized the reversed flow from this cathodic EOF as a driving force for sample proteins using permanently uncoated but dynamic SDS-coated PMMA microchips. High-speed (6 s) separation of proteins and peptides up to 116 kDa was successfully achieved using this system.

Adsorption↗

Titanium dioxide nanoparticles-coated column for capillary electrochromatographic separation of oligopeptides.

A novel column made through the condensation reaction of TiO2 nanoparticles (TiO2 NPs) with silanol groups of the fused-silica capillary is described. EOF measurements under various buffer constitutions were used to monitor the completion of reactions. The results indicated that the EOF was dependent on the interactions between buffers and the bonded TiO2 NPs. With formate/Tris buffer, EOF reversal at pH below 5 and cathodic EOF at pH above 5 were indicated. The pI of the bonded TiO2 NPs was found at approximately ph 5. Only cathodic EOF was illustrated by substituting the mobile phase with either glutamate or phosphate buffer. It was elucidated that both glutamate and phosphate buffer yield a negative charge layer on the surface of TiO2 NPs attributable to the formation of a titanium complex. The CEC performance of the column was tested with angiotensin-type oligopeptides. Some parameters that would affect the retention behavior were investigated. The interactions between the bonded phases and the analytes were explicated by epitomized acid-base functional groups of the oligopepetides and the speciation of the surface oxide in different pH ranges. The average separation efficiencies of 3.1 x 10(4) plates/m is readily achieved with a column of 70 cm (50 cm) x 50 mum ID under an applied voltage of 15 kV, phosphate buffer (pH 6.0, 40 mM), and UV detection at 214 nm.

Angiotensins↗

Fluorescence imaging of sample zone narrowing and dispersion in a glass microchip: the effects of organic solvent (acetonitrile)-salt mixtures in the sample matrix and surfactant micelles in the running buffer.

A mismatch in the EOF velocities between the sample zone and running buffer region is known to generate pressure-driven, parabolic flow profile of the sample plug in electrokinetic separation systems. In the present study, video fluorescence microscopy was employed to capture real-time dynamics of the sample plug (containing fluorescein as the probe molecule) in a discontinuous conductivity system within a glass microchip, in which the sample matrix consisted of a mixture of ACN and salt (NaCl), and the running buffer contained sodium cholate (SC) micelles as the pseudo-stationary phase (i.e., performing "ACN stacking" in the mode of MEKC). Upon application of the separation voltage, the video images revealed that zone narrowing and broadening of the probe molecules occurred as the sample plug headed toward the cathode during the initial time period, probably resulting in part from the stacking/sweeping, and destacking of the SC micelles at the boundaries between the sample zone and running buffer. Interestingly, a second sample zone narrowing event can be observed as the sample plug moved further toward the cathode, which could be attributed to the sweeping of the slower moving probe molecules by the faster moving SC micelles that originated from the anode. This phenomenon was studied as a function of pH, sample plug length, as well as the concentration of organic solvent and salt in the sample matrix. The data suggested that the presence of large amounts of an organic solvent (such as ACN or methanol) and salts in the sample matrix not only induces sample dispersion due to the formation of a pressure-driven (hydrodynamic) flow, but may also lead to the formation of a double sample zone narrowing phenomenon by altering the local EOF dynamics within the separation system.

Acetonitriles↗

Reversed-phase and weak anion-exchange mixed-mode silica-based monolithic column for capillary electrochromatography.

A silica-based CEC monolithic column with mixed modes of RP and weak anion-exchange (WAX) was successfully prepared by using the sol-gel technique at mild temperature. The synthesizing procedure was optimized by changing the ratios of tetraethoxysilane (TEOS), aminopropyltriethoxysilane (APTES), and octyltriethoxysilane (C(8)-TEOS) in the mixture. While serving as WAX group, the amino group dominated the charge on the surface of the capillary column and generated an EOF from cathode to anode at low pH. At pH above 7.5, a cathodic EOF was observed due to the full ionization of silanol group and the suppression in the ionization of amino group. The morphology of monolithic columns was examined by SEM, and the performance of column was evaluated in detail by separating different kinds of compounds. As expected, the monolithic column exhibited RP chromatographic behavior for neutral solutes. Fast and efficient separation of six aromatic acids was obtained using acidic mobile phase with column efficiency up to 160,000 plates/m. Symmetrical peaks can be obtained for aromatic amines because positively charged amino groups on the surface can effectively minimize the adsorption of positively charged analytes to the stationary phase.

Acetonitriles↗

Effect of alkali metal hydroxides on the enantioseparation of amines using di-O-isopropylidene-keto-L-gulonic acid as the selector in NACE.

The present work demonstrates the importance of the ionic composition in the BGE for enantioseparation. (-)-2,3:4,6-di-O-Isopropylidene-2-keto-L-gulonic acid ((-)-DIKGA) has been used as the chiral selector in methanolic and ethanolic BGEs. The influence of added alkali metal hydroxides on the EOF and the chiral separation of amines (atenolol, isoprenaline, pindolol and propranolol) have been studied. The ion-pair formation constants in ethanol were determined by precision conductometry for the enantiomers of pindolol with (-)-DIKGA, for Li(+), Na(+) and Cs(+) with (-)-DIKGA, and also for the corresponding alkali metal hydroxides. The effective mobilities and the enantiomeric mobility differences were affected by the type of alkali metal hydroxide (LiOH, NaOH, KOH, RbOH or CsOH) added to the BGE. The effective mobility and mobility difference were increased with decrease in solvated radius of the alkali metal cation. These differences could partly be correlated to the ion-pair formation constants of the alkali metal cations with the chiral selector, affecting the equilibrium concentration of the free selector. The electroosmosis was also affected by the alkali metal hydroxide added to the BGE. The cathodic electroosmosis decreased with decreasing solvated radius of the alkali metal cation added to the BGE. Interestingly, the cathodic EOF was even reversed, i.e. became anodic in the ethanolic BGEs containing KOH, RbOH or CsOH and the methanolic ones with RbOH and CsOH.

Amines↗