Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMB”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

The gait of unilateral transfemoral amputees.

The aim of this study was to describe the gait of persons with a unilateral transfemoral amputation by means of a questionnaire, gait analysis and measurement of energy expenditure, and to find correlations among the variables studied. The study included 29 transfemoral amputees amputated for other reasons than a chronic vascular disease. The patients were assessed using the following methods: 1) A questionnaire rating the walking distance and walking difficulty in different circumstances. 2) Gait analysis measuring temporal variables and goniometry of hips and knees. 3) Measurement of energy expenditure during sitting and walking. Scores on the questionnaire showed a correlation with socket design, a negative correlation with age and energy expenditure, and a positive correlation with fast speed. The gait of transfemoral amputees was asymmetrical as far as temporal variables were concerned, and for most amputees also for the range of motion of hip and knee. The walking speed of the amputees was lower than that of non-amputees and showed a positive correlation with hip extension-flexion range of motion and a negative correlation with age and stride time. The energy expenditure of the amputees during ambulation was higher than that of non-amputees, and seemed to correlate with residual limb length and the hip abduction-adduction range of motion.

Adolescent↗

Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.

Fitting of a prosthetic socket is a critical stage in the process of rehabilitation of a trans-tibial amputation (TTA) patient, since a misfit may cause pressure ulcers or a deep tissue injury (DTI: necrosis of the muscle flap under intact skin) in the residual limb. To date, prosthetic fitting typically depends on the subjective skills of the prosthetist, and is not supported by biomedical instrumentation that allows evaluation of the quality of fitting. Specifically, no technology is presently available to provide real-time continuous information on the internal distribution of mechanical stresses in the residual limb during fitting of the prosthesis, or while using it and this severely limits patient evaluations. In this study, a simplified yet clinically oriented patient-specific finite element (FE) model of the residual limb was developed for real-time stress analysis. For this purpose we employed a custom-made FE code that continuously calculates internal stresses in the residual limb, based on boundary conditions acquired in real-time from force sensors, located at the limb-prosthesis interface. Validation of the modeling system was accomplished by means of a synthetic phantom of the residual limb, which allowed simultaneous measurements of interface pressures and internal stresses. Human studies were conducted subsequently in five TTA patients. The dimensions of bones and soft tissues were obtained from X-rays of the residual limb of each patient. An indentation test was performed in order to obtain the effective elastic modulus of the soft tissues of the residual limb. Seven force sensors were placed between the residual limb and the prosthetic liner, and subjects walked on a treadmill during analysis. Generally, stresses under the shinbones were approximately threefold higher than stresses at the soft tissues behind the bones. Usage of a thigh corset decreased the stresses in the residual limb during gait by approximately 80%. Also, the stresses calculated during the trial of a subject who complained about pain and discomfort were the highest, confirming that his socket was not adequately fitted. We conclude that real-time patient-specific FE analysis of internal stresses in deep soft tissues of the residual limb in TTA patients is feasible. This method is promising for improving the fitting of prostheses in the clinical setting and for protecting the residual limb from pressure ulcers and DTI.

Amputees↗

[Study of bone mass with dual energy x-ray absorptiometry in a population of 99 lower limb amputees].

OBJECTIVES: Osteopenia in lower extremity amputation is described with an increased risk of fracture and it seems to be interesting to study bone mass in a population of 99 amputees of limb. MATERIAL AND METHOD: We studied the bone mass with Dual Energy Xray Absorptiometry in patients with limb amputation, above and under knee and who have been treated in the rehabilitation department of Mulhouse's hospital and more specifically the percentage of the difference of the mesure between amputed and non amputed side and the influence on this mesure of several factors like sexe; age; diabetes mellitus; delay of amputation; aetiology and use of prosthesis. RESULTS: For all the population, we find lower values of BMD (Bone mineral density) for femoral neck -10.4% +/- 12.2 (P < 0,001) and trochanter -14.9% +/- 14.5 (P < 0,001) between amputated and non amputated side, and also comparing with normal population -19.9% +/- 18.8 (P < 0,001) for femoral neck and -8.8% +/- 22 (P < 0,001) for trochanter.There is no influence of sexe, age, and time since amputation on BMD. The study of sub-groupes shows that the loss of bone mass is depending on traumatic amputation, the level of amputation (above knee) and when prothetis doesn't fit. Arteritis or diabetis are not pejoratif factors. CONCLUSION: This work confirms the mechanical factors as an important parameter of bone loss in the limb amputation.

Absorptiometry, Photon↗

Comparison of interface pressures with pin and suction suspension systems.

A common mode of limb suspension for transtibial amputees is the pin liner/shuttle lock system. Despite its popularity, some clinicians question its use because of observed daily and chronic changes to the residual limb. For this study, we measured limb interface pressures during ambulation with pin and suction suspension systems. No pressure differences were seen between the modes of suspension during stance phase. However, during swing phase, pin suspension maintained an average occlusive compressive pressure of 6.7 kPa on the proximal tissues, as compared to the subocclusive pressure of 1.1 kPa with suction suspension. Simultaneously, pin suspension elevated the peak magnitude of suction to -39.5 kPa at the distal residual limb, compared to -26.1 kPa with suction suspension. During swing phase, the pin liner squeezes proximally while creating a large suction distally on the residual limb and is the likely cause of daily and chronic skin changes observed in pin users.

Adult↗

Function of skin grafts in children following acquired amputation of the lower extremity.

BACKGROUND: Investigators have recommended aggressive use of skin-grafting in order to preserve length and proximal joint function following an acquired amputation in children. However, there is little objective evidence to either support or refute that recommendation. METHODS: We performed a retrospective review of the cases of all children for whom a skin graft had been applied to the residual limb following an acquired lower-extremity amputation at our Limb Deficiency Clinic between 1984 and 2002. Skin graft dysfunction, defined as breakdown, contracture, and/or pain, was considered to be clinically relevant if it required the child to discontinue use of the prosthesis for any period of time or if it required revision surgery to facilitate continued prosthetic fitting. RESULTS: Twenty-three children (mean age at amputation, 4.4 years) with a total of thirty-one acquired lower-extremity amputations had been treated with skin-grafting. At a mean of 6.3 years after the operation, sixteen (52%) of the thirty-one extremities had had no episodes of skin graft dysfunction. The remaining fifteen extremities (48%) had had clinically relevant skin graft dysfunction (breakdown in thirteen and contracture and pain in one extremity each). Nine of the ten extensive skin grafts underwent clinically relevant breakdown, as did thirteen of the twenty-four grafts that were located distally on the residual limb. Subsequent surgical revision of the residual limb because of inadequate function of the skin graft was performed on seven extremities (23%), with revision to a more proximal limb-segment level required in five. CONCLUSIONS: Focal skin-grafting (involving < or = 25% of the surface area) of partial-thickness soft-tissue defects in order to optimize the length of the residual limb at the time of an amputation is an effective option for children with an acquired lower-extremity amputation. Limited skin-grafting (involving 26% to 50% of the surface area) is more likely to result in skin graft breakdown, particularly when it is done distally. Extensive skin-grafting, while technically possible, frequently requires revision and rarely results in an optimally functioning limb. Alternative treatment strategies should be considered for extremities that would require extensive, distal skin-grafting.

Adolescent↗

Prostheses, pain and sequelae of amputation, as seen by the amputee.

Results of a survey of 19 organizations belonging to World Veterans Federation indicate that major complains of amputees include; poor fitting, poor dissemination of knowledge to doctors and amputees regarding new prostheses, lack of opportunity for "input" from amputees at research level and inadequate measures to deal with phantom and stump pain. Suggested improvements by amputees; decrease in weight of prostheses, reduction in maintenance for swing and stance-phase control units development of recreational prostheses, more frequent checks through use of X-ray and film techniques, particularly during the "break-in" of a new appliance. Older veterans showed increasing concern in regard to development of consequential disabilities arising from amputation; premature arthritic changes in spine and remaining limb, circulatory problems and gastro-intestinal problems due to ingestion of drugs to control pain.

Adaptation, Psychological↗

Early post-surgical prosthetic limb fitting in dysvascular below-knee amputees with a pre-fabricated temporary limb.

Two consecutive series of patients undergoing below-knee amputation for peripheral vascular insufficiency were compared relative to the length of acute-care hospitalization and rehabilitation. The residual limb control group was treated with soft-surgical dressings and non-weight bearing ambulation with referral to the amputee clinic when the residual limb wound was "ready." The residual limb experimental group was treated with rigid plaster (cast) dressings with early post-surgical prosthetic limb fitting and progressive weight bearing ambulation. Acute-care hospitalization following amputation surgery averaged 27.7 days in the control group, and 23.7 days in the treated group. Patients were either re-admitted or transferred to a rehabilitation unit where hospitalization averaged 42.9 days in the control group and 14.1 days in the treated group. This resulted in a cost savings of almost $15,000 per patient based on present hospital fees. The results of this study suggest that early post-surgical prosthetic limb fitting not only hastens recovery amputation, but can be safe and cost effective.

Adult↗

Below-knee residual limb shape change measurement and visualization.

OBJECTIVE: The ability to measure and visualize shape change (deformation) of a residual limb within and between prostheses is an important step toward improved prosthetic fit assessment. The objective was to develop measurement and visualization methods for below-knee residual limb soft tissue shape change after donning and loading a prosthesis to detect small shape changes (30mm or less). DESIGN: Spiral X-ray computed tomography imaging was utilized to acquire 3D volumetric data of the below-knee residual limb and prosthesis in situ from poor- and a good-fitting prostheses without and with a load. A new sum projection depth-shaded cylindrical mapping technique to measure and visualize small changes in shape was developed. From the volumetric data, the relative displacement of small lead markers placed on the residual limb's skin surface were measured using multiplanar reconstruction images and cylindrical maps. Displacement measurements averaging 15mm or less were obtained. RESULTS: The precision and accuracy was 1mm and 2mm, respectively, when measuring the shape change or deformation of the skin surface from the sum projection cylindrical maps. The skin surface deformation was at least 7mm or greater when comparing marker locations between scans with the prostheses in situ. CONCLUSION: These new image-based measurement and visualization methods provide a feasible means for measuring and displaying lower extremity residual limb shape change within and between different prostheses with and without loading.

Adult↗

Decrease in phantom limb pain associated with prosthesis-induced increased use of an amputation stump in humans.

The experience of phantom limb pain, non-painful phantom limb sensation and telescoping was ascertained by questionnaire in a group of upper extremity amputees wearing a functionally effective Sauerbruch prosthesis which permits extensive use of the affected limb and in a group of patients wearing a cosmetic prosthesis that did little to increase the utilization of the amputation stump. The Sauerbruch prosthesis group exhibited a significant and large decrease in amount of phantom limb pain while the cosmetic prosthesis group showed no change. Neither group experienced a decrease in non-painful phantom limb sensation or telescoping. The amount of phantom limb pain has been found to be highly correlated with the amount of injury-related, afferent-decrease cortical reorganization. It is possible that the increased use of the amputation stump induced by wearing a Sauerbruch prosthesis produced a countervailing use-dependent, afferent-increase type of cortical reorganization that reversed the phantom limb pain. These preliminary results require replication. Their therapeutic implications are discussed.

Adult↗

Lower limb amputation. Part 3: Prosthetics--a 10 year literature review.

This paper is intended as a follow-up to the ISPO Consensus Conference on Amputation Surgery. It reviews all the literature on lower limb prosthetics published after 1990. The review was considered under six categories: feet, knees, hips, thermoplastics, liners/suspension and computers.

Amputation, Surgical↗

Biomechanical significance of the correct length of lower limb prostheses: a clinical and radiological study.

The length of the lower limb prosthesis was compared with the length of the contralateral lower extremity in 113 Finnish war-disabled amputees by a radiological weight bearing method developed by the author. Considering a shortening of 10 mm for above-knee prostheses and of 5 mm for below-knee prostheses as tolerance limits, the length of the prosthesis was acceptable only in 17 cases (15% of the total group). In 79 cases (70%) the prosthesis was up to 47 mm too short and in 17 cases (15%) up to 40 mm too long. Chronic pain symptoms of low back, hip and knee correlated significantly with the lateral asymmetry caused by incorrect length of the prosthesis. Independently of the side of amputation, the unilateral sciatica and chronic hip pain occurred mainly on the long leg side. Physical activity of the lower limb amputees seemed to correlate with the suitability of the length of the prosthesis, and was unrelated to the length of the amputation stump.

Aged↗

The care of the limb deficient child in India.

The problem of treating limb deficient children in India is compounded by many factors, social, cultural and economic. Few attend early and most therefore manage without prosthetic care.

Artificial Limbs↗

Quantitative analysis of the effects of audio biofeedback on weight-bearing characteristics of persons with transtibial amputation during early prosthetic ambulation.

Residual limb recovery after a transtibial amputation depends largely on close monitoring of the weight-bearing activities during the early postoperative stage. Although a biofeedback device, in particular audio biofeedback, was recommended to be used, no quantitative studies regarding its effectiveness in monitoring the weight-bearing activity of a person with amputation were available. In this study, six persons with transtibial amputation were asked to replicate a prescribed amount of weight bearing using a bathroom scale method during their early postoperative ambulatory training. Their weight-bearing characteristics with and without using audio biofeedback were continuously monitored using a load monitoring device and compared with the prescribed load. The results showed that the residual limb would be overloaded using the conventional bathroom scale method during early postoperative ambulatory training if no audio biofeedback was provided. It was demonstrated that audio biofeedback was useful in preventing the residual limb from being overloaded beyond the prescribed load particularly when the prescribed load was low.

Aged↗

[The patient undergoing amputation of the lower limbs and the changes in activities of daily living].

The present study is part of the DIOGO monograph. The objective is to verify the alterations identified in aged patients which had been submitted to amputation of their lower limbs, in relation to everyday life. The data was collected from 25 inpatients, of a government university hospital. The analysis of the results suggests that the alterations referred by the patients submitted to amputation less than 10 days before coincide with those referred by aged patients which had had their limbs amputated over a month before, in the items related to body hygiene and locomotion.

Activities of Daily Living↗

Trans-femoral amputee pilots: criteria for return to the fighter cockpit.

Proximal lower limb amputations (trans-femoral) usually leave amputees with significant functional disturbances. This article contains information regarding three pilots with trans-femoral amputations that returned swiftly to continue their aeronautical careers despite their disabilities. Adaptations are needed in the limb prostheses to enable the amputees to access the minimally spaced cockpit.

Adult↗

Rehabilitation of the elderly amputee.

A rehabilitation service based in a department of geriatric medicine and dealing exclusively with amputees aged 65 years or over, is described. Provision of prostheses has been expedited, and the multi-disciplinary approach of the department has been beneficial in rehabilitation especially of the amputee with multiple pathology. The experience of the first 146 patients with an average age of 74.1 years is reviewed. Discharge home was achieved in 77.6% of the patients provided with a prosthesis and in a small multi-centre study of the post discharge status of 20 elderly amputees it was found that over 90% used their prosthesis regularly and the great majority were independent in the activities of daily living. Although BKA (Below knee amputation) is preferable to AKA (Above knee amputation), the functional benefit in this age group is not always as significant as traditional attitudes would suggest whereas a failed BKA has serious consequences in terms of psychological impact, morbidity and length of hospital stay. In order to minimise the number of BKA's requiring revision or re-amputation every effort should be made to ensure that the initial procedure is carried out by a surgeon with experience of amputation in this age group. Limb provision is cost effective and the frequent difficulty with regard to the financing of prostheses for elderly amputees is counter-productive.

Aged↗

Below-knee amputee gait in stair ambulation. A comparison of stride characteristics using five different prosthetic feet.

The purpose of this study was to compare the stride characteristics provided by four of the new dynamic elastic response prosthetic feet and the SACH foot to determine if any of them provided an increased performance during stair ambulation. Ten traumatic below-knee amputees were studied; each of them tested all five prosthetic feet (Flex-Foot, Carbon Copy II, Seattle, Quantum, and SACH). Compression closing footswitches were used to calculate stride characteristics while ascending and descending a four-step staircase. The only significant difference between feet was found during the initial double-limb support (IDLS) phase of stair ascent, with the Flex-Foot providing a more symmetrical amputated:sound limb IDLS ratio compared with the SACH foot (1.03 versus 1.30). The increased IDLS time seen with the SACH foot reflects the inability to adequately advance the tibia and body weight over the prosthetic foot to achieve progression. This lack of progression and symmetrical gait pattern between limbs may be a function of the limited dorsiflexion range inherent with the SACH foot.

Amputation, Traumatic↗