The predictive value of indium-111 leukocyte scans in the diagnosis of infected total hip, knee, or resection arthroplasties.

To evaluate the usefulness of the indium-111 scan in detecting actually or potentially infected total hip, knee, and resection arthroplasties, 153 scans were performed on 143 patients who underwent reoperation for a loose or painful total joint arthroplasty or a resection arthroplasty between 1990 and 1996. Scans were interpreted as infected, not infected, or equivocal by an experienced nuclear medicine radiologist. Patients were considered to be infected if they met any 2 of the following criteria: i) positive intraoperative cultures, ii) final permanent histologic section indicating acute inflammation, and iii) intraoperative findings of gross purulence within the joint. Twenty-six patients (17%) met the infection criteria at the time of reoperation. Indium scans were found to have a 77% sensitivity, 86% specificity, 54% and 95% positive and negative predictive values, and 84% accuracy for the prediction of infection. Of 6 equivocal scans, none were infected. The results of this study suggest limited indications for the use of the indium-111 scan in the evaluation of painful hip, knee, or resection arthroplasties. A negative indium scan may be helpful in suggesting the absence of infection in cases in which the diagnosis is not otherwise evident.

Adult↗

Resection arthroplasty of the hip.

Forty-four patients with 46 resection arthroplasties performed for various indications were followed an average of 8.0 years. Pain relief was good or excellent in 77% and eradication of infection was achieved in all but one. Completeness of cement removal at the time of resection arthroplasty did not affect the results or control of infection. Patients with a history of prior septic total hip arthroplasty had results similar to those for patients with other indications for resection arthroplasty. A comprehensive review of the literature supports these results.

Activities of Daily Living↗

Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty.

Fractures of the ceramic ball in total hip arthroplasty are an uncommon cause of arthroplasty failure, and reports of this complication in ceramic-on-polyethylene total hip arthroplasty articulations are rare. Ball fractures have been reported in patients who were overweight, had high levels of activity, or had been injured. Other postulated contributory factors have included small ball diameter, defects in ceramic quality or manufacture, and errors in implantation of the arthroplasty. A case of a ceramic ball fracture in a ceramic and polyethylene articulation is reported, and the literature on such fractures is reviewed.

Ceramics↗

Relationship of surgical volume to short-term mortality, morbidity, and hospital charges in arthroplasty.

In 1992, the Agency of Health Care Administration in Tallahassee, Florida, started releasing, as part of the patient discharge information, the names of the treating physicians, in addition to demographic and diagnostic data. This information is available to the general public for a small price and is being used by health planners, hospital administrators, finance departments, third-party payers, and other agencies involved in health care. Patient discharge information was used to assess the effects of volume on the short-term outcome of primary and revision hip and knee arthroplasty as a function of surgeon and hospital in the State of Florida, during 1992. A total of 19,925 primary and 2,536 revision arthroplasties of the hip and knee were performed during 1992 in Florida and were available for study. After the doctors and hospitals were arbitrarily divided into three case volume groups (low, medium, high), results showed that in primary arthroplasty, surgeons with a low volume of primary cases (< 10) have a significantly higher mortality rate (24%), higher average charges ($25,000), and increased average length of hospital stay (9.3 days). In revision surgery, physicians with a low volume of cases (< 10) have a higher mortality rate (13%) and increased average length of hospital stay (9.8 days). Patients discharge information has many potential uses for investigators interested in the short-term outcome of arthroplasty. In their present form, these databases should not be released to the general public or the media. Lastly, the volume-outcome relation for a specific surgical procedure should, in addition to case severity, account for characteristics affecting the degree of technical difficulty.

Florida↗

Prosthetic component failures in hip arthroplasty surgery.

A survey was conducted of the entire membership of the American Association of Hip and Knee Surgeons to determine their experience with total hip arthroplasty (THA) device-related failures. Forty-seven percent of the membership reviewed their preceding 5-year clinical experience and returned the survey instrument. The aggregate 5-year volume encompassed experience with more than 60,000 hip arthroplasties. The median 5-year experience per respondent was 200 metal-based sockets and 214 metal stems. The frequency distribution of the number of hip arthroplasties per respondent was skewed to the right, with fewer surgeons reporting the higher volumes of arthroplasties. In aggregate, 60,115 of the acetabular components used were metal backed. Nonmetal acetabular component usage totaled 3,219. Complete polyethylene failure was defined as fracture or complete wear through of the polyethylene portion of the component. Complete polyethylene failure was seen in 172 metal-backed sockets (29/10,000). Seventy-seven all-polyethylene sockets had complete polyethylene failure (239/10,100). A total of 87 THAs were revised for modular acetabular dissociations for a dissociation rate of 15/10,000. In aggregate, 64,483 metal-stemmed components were used. Femoral stem fractures occurred in 172 for a rate of 27/10,000. A total of 56,965 metallic femoral components were reported as being modular. Dissociation between the femoral head and neck was uncommonly seen (3/10,000). Use of ceramic femoral heads was low (5,023); however, a total of 11 ceramic head fractures were revised in the 5-year period for a failure rate of 22/10,000. The risks of catastrophic prosthetic THA failure are low but vary according to hip component and the manufacturer of the part.

Ceramics↗

Intraoperative autologous transfusion in primary and revision total hip arthroplasty.

Significant blood loss during total hip arthroplasty is usually unavoidable. Blood loss is even more of a problem during revision total hip arthroplasty. Using the Cell-Saver for retrieval of red blood cells to be used for autotransfusion during surgery is a safe and useful way of sparing donor blood transfusion. This is a retrospective analysis of primary and revision total hip arthroplasty cases and comparison between cases in which Cell-Saver was used versus those in which Cell-Saver was not used. Generally accepted standards to determine the need for blood transfusion, including measured serum hemoglobin and patient symptoms and vital signs, were used as guidelines in treating patients. Using multiple regression models and taking into account certain variables between cases, it was determined that a significant amount of donor blood transfusion can be saved when the Cell-Saver is used. The Cell-Saver is an important aid in intraoperative treatment for both primary and revision total hip arthroplasty cases.

Aged↗

Heterotopic ossification following primary total knee arthroplasty.

Heterotopic ossification is a rare complication following primary total knee arthroplasty and may be symptomatic if massive enough. The authors retrospectively reviewed 158 primary total knee arthroplasties from 1985 to 1989 and found 6 cases (3.8%) of heterotopic ossification. Patients were graded before and after surgery according to the Hospital for Special Surgery total knee arthroplasty score and their histories were reviewed for the presence of recognized risk factors for heterotopic ossification and whether a manipulation under anesthesia was performed. This report describes the incidence of, appearance of, and clinical risk factors for heterotopic ossification following primary total knee arthroplasty in this series. A radiographic grading system is proposed.

Aged↗

Heterotopic ossification following uncemented total hip arthroplasty.

Heterotopic ossification following an uncemented total hip arthroplasty should theoretically demonstrate a higher incidence than a cemented arthroplasty. This is due to increased production of bone debris following vigorous femoral canal and pelvic reaming, which should provide increased stimulatory factors for ectopic bone production. The authors examined 196 consecutive primary total hip arthroplasties prospectively for 1 year. The overall incidence of heterotopic ossification was 26% with only one patient having a Grade III (severe) amount of ectopic bone. This incidence is consistent with those reported in cemented total hip arthroplasties. This paper does not support Puzas et al theory of bone dust providing a stimulatory factor for the production of heterotopic bone.

Aged↗

Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty.

Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.

Adult↗

Aseptic loosening after total hip arthroplasty. Incidence, clinical significance, and etiology.

Three hundred forty-one consecutive Charnley total hip arthroplasties were reviewed after a 3-10-year follow-up period to correlate the radiographic signs of aseptic loosening to clinical outcome, femoral cementing technique, and epidemiologic patient characteristics. High-grade femoral demarcation at the bone-cement interface (75-100%) correlated with a significantly higher incidence of unsatisfactory follow-up clinical scores. The incidence of high-grade femoral bone-cement demarcation and the associated radiographic signs of aseptic loosening had a direct correlation with the quality of the femoral cementing technique (P less than .01). Trochanter nonunion or trochanter separation demonstrated a highly significant correlation with high-grade femoral bone-cement demarcation (P less than .001). Patients having secondary total hip arthroplasty for failed cup arthroplasty or endoprosthesis had a higher rate of unsatisfactory pain and function scores, compared with those having arthroplasties performed after failed internal fixation. Male patients or patients with a high activity level demonstrated a twofold greater incidence of high-grade femoral demarcation (P less than .05). Patient weight by itself did not demonstrate any effect on radiographic outcome.

Age Factors↗

Selection of an animal model for resurfacing hip arthroplasty.

This study was done to determine whether sheep provide a better model of resurfacing hip arthroplasty than dogs. Eighteen sheep were subjected to unilateral resurfacing arthroplasty. Fifty-eight percent developed femoral loosening by 10 months. This reflects the clinical situation in humans: loosening has been the leading cause of failure. By contrast, reports of experiments with dogs describe very low loosening rates. Sheep provide a more stringent test of hip arthroplasty than dogs. The critical difference appears to be activity level. Sheep allowed free activity on a farm more closely simulate the situation of active patients than do dogs housed in small enclosures in conventional research facilities. New techniques of prosthetic hip arthroplasty that lend themselves to animal models should be studied in sheep before being studied in humans.

Animals↗

Proximal femoral osteotomy as an adjunct in cementless revision total hip arthroplasty.

Cementless total hip replacement techniques are increasingly used in revision arthroplasty. A major challenge is to achieve implant stability in a femur distorted by a failed arthroplasty. Five patients with aseptic loosening of cemented primary or revision total hip replacements complicated by significant proximal femoral disease, four with marked angular deformity of the femur and one with a subtrochanteric nonunion, were treated successfully with cementless revision arthroplasty combined with proximal femoral osteotomy. At follow-up examination, all femoral and trochanteric osteotomies had healed and D'Aubigne and Postel scores for pain, function, and range of motion had improved. All porous prostheses demonstrated radiographic features consistent with bone ingrowth fixation. No progressive stress shielding has been observed. Concomitant femoral osteotomy to correct anatomic deformity, in association with cementless total hip arthroplasty, results in union of the osteotomy and restoration of hip function.

Adult↗

Femoral revision total hip arthroplasty using a long-stem femoral component. Clinical and radiographic analysis.

Proximal femoral bone stock deficiencies exist during many femoral revision arthroplasties, thus providing inadequate support and fixation for conventional-length cemented femoral components. The authors analyzed the long-term clinical and roentgenographic results of 165 hips requiring femoral revision arthroplasty with a long-stem femoral prosthesis. Intraoperative complications occurred in 23% of hips, with femoral perforations in 16% and femoral fractures in 5%. Of 110 hips with at least 5 years of follow-up study (average, 6.7 years), functional ratings were graded excellent in 34%, good in 36%, fair in 17%, and poor in 13%. Failures occurred in 17 hips (12%) and were attributed to aseptic loosening (11 hips), femoral component fracture (2), femoral shaft fracture (1), and sepsis (3). Symptomatic trochanteric separations occurred in 16% of hips. Rerevision or resection arthroplasty was required in 7 hips (5%) and recommended for another 10 hips (7%). Cemented long-stem femoral components (versus cemented conventional-length stems) decrease the extent and progression of femoral lucencies, thereby lowering the incidence of mechanical failures and improving long-term functional results in cemented femoral revision arthroplasty.

Adult↗

Clinical experience with a triradiate exposure of the hip for difficult total hip arthroplasty.

A triradiate exposure of the hip was developed to facilitate the performance of certain difficult primary and revision total hip arthroplasties. Using this triradiate skin and fascial incision, complete anterior and posterior exposure of the hip capsule can be performed with relative ease. Between October 1980 and January 1985, this exposure was used 50 times in selected cases, including 9 of 320 (3%) primary total hip arthroplasties. All of these cases involved obesity, acetabular protrusion, and/or fragile femoral bone, conditions that would have made safe, adequate exposure without trochanteric osteotomy considerably more difficult through a routine anterolateral or posterior approach. Over this period, the majority of revision hip arthroplasties were performed using triradiate exposure; trochanteric osteotomy was routinely performed in these revision cases. Excellent wound healing was observed in every case, despite unfavorable factors such as advanced age, prednisone therapy, and the presence of prior incisional scars. The triradiate incision offers safe, controlled, and improved exposure in selected primary and revision total hip arthroplasties. It has become nearly the routine incision for the senior author for revision cases.

Aged↗

Glenoid loosening in total shoulder arthroplasty. Association with rotator cuff deficiency.

Seven cases of total shoulder arthroplasty exhibiting major glenoid radiolucent lines or actual translation of the glenoid component were evaluated to identify factors associated with glenoid loosening. The average time from arthroplasty was 30 months (range, 14-44 months). Six of the patients had severe, incompletely reconstructable rotator cuff tears present at the time of surgery, and one patient developed a cuff tear within 1 year of surgery. The amount of superior migration of the humeral component was closely correlated with the degree of glenoid loosening. With superior displacement of the humeral component, superior tipping of the glenoid component was observed: a "rocking horse" glenoid. For comparison, a contemporary group of 16 consecutive total shoulder arthroplasty patients with intact rotator cuffs were reviewed. The control group had no glenoid loosening an average of 5 years after operation. Upward riding of the prosthetic humeral head in patients with rotator cuff deficiency may contribute to loosening of the glenoid component in total shoulder arthroplasty.

Aged↗

Revision total hip arthroplasty in patients younger than 55 years old. Clinical and radiologic results after 4 years.

Since 1979, all revision total hip arthroplasties performed in Sweden have been entered into a prospective multicenter study. Between 1979 and 1982, 65 patients (67 hips) younger than 55 years old required revision arthroplasty because of aseptic loosening. These patients were followed clinically and radiographically for 2-6 years (mean, 4 years). Thirteen patients requiring a second revision because of a recurrent aseptic loosening and one because of subluxations were classified as failures and were not included in the final follow-up study. In the remaining 52 hips (50 patients), the results, rated by the Harris hip score, were good or excellent in 15 hips (29%), fair in 9 hips (17%), and poor in 28 hips (54%). Early complications were rare. Ten hips in 10 patients had radiographic signs of gross loosening of the acetabular or femoral component. mechanical failure, defined as gross loosening or a second revision, was identified in 36% of hips included in the study (n = 67). Revision hip arthroplasty using cement in young and middle-aged patients with cemented primary arthroplasty gave a high rate of failure, because of aseptic loosening. The use of alternative methods and techniques must be explored for revision surgery in younger patients.

Adult↗

Clinical results after revision and primary total hip arthroplasty.

Results after 184 primary and 227 revision total hip arthroplasties were compared with an emphasis on rates of failure leading to reoperation and intra- and postoperative complications and on the clinical outcome of the nonrevised arthroplasties in the two series. The failure rate was 7% (11 of 156) in the primary series, versus 27% (54 of 195) in the revision series. The rate of complications was substantially higher after revision, due to 16% (36 of 227) intraoperative fractures of the femoral shaft and 6% (14 of 227) postoperative dislocations. Clinical assessment of the nonrevised arthroplasties in the two series revealed no difference with regard to relief of pain. For patients with concomitant disabling conditions functional outcome was inferior after revision, but for patients without such conditions the functional results of the two series were equal. The favorable clinical results of the nonrevised arthroplasties in the revision series must be seen in relation to the very high rate of failure leading to reoperation.

Adult↗

Survivorship analysis of failure pattern after revision total hip arthroplasty.

Failure, defined as established indication for or performed re-revision of one or both components, was analyzed using survivorship methods in 306 revision total hip arthroplasties. The longevity of revision total hip arthroplasties was inferior to that of previously reported primary total hip arthroplasties. The overall survival curve was two-phased, with a late failure period associated with aseptic loosening of one or both components and an early failure period associated with causes of failure other than loosening. Separate survival curves for aseptic loosening of femoral and acetabular components showed late and almost simultaneous decline, but with a tendency toward a higher rate of failure for the femoral component. No differences in survival could be found between the Stanmore, Lubinus standard, and Lubinus long-stemmed femoral components. A short interval between the index operation and the revision and intraoperative and postoperative complications were risk factors for early failure. Young age was a risk factor for aseptic loosening of the femoral component. Intraoperative fracture of the femoral shaft was not a risk factor for secondary loosening. No difference in survival was found between primary cemented total arthroplasty and primary noncemented hemiarthroplasty.

Adult↗