Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography.

PURPOSE: To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography. MATERIALS AND METHODS: The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Basic imaging characteristics of the FPD and associated image processing system were assessed on acquired images, including linearity, repeatability, uniformity of response, modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), contrast sensitivity, and scatter content. Results with the FPD system were compared to those with a storage phosphor computed radiography (CR) system. RESULTS: Images obtained with the FPD demonstrated excellent uniformity, repeatability, and linearity, as well as MTF and DQE that were superior to those with the storage phosphor CR system. The contrast and scatter content of images acquired with the FPD were equivalent to those acquired with the storage phosphor system. CONCLUSION: The FPD provides radiographic images with excellent inherent physical image quality.

Evaluation Studies as Topic↗

Validation of dynamic radiography in the dog and evaluation of ischemic dyssynergy.

If a collimated radiation detector (sodium iodide crystal) and a collimated X-ray source are positioned at right angles, scattered radiation will be sensed and the detector will generate a signal as tissue enters and leaves the "sensitive volume" formed by the intersection of the field of view of the detector and incident beam. This technique, called dynamic radiography, was used to identify and quantify the components of epicardial motion in anesthetized open-chested dogs. The data so obtained were validated by two independent optical methods: biplane cinematography and a technique that measures the shadow cast by the heart using a light beam-cadmium sulfide photocell. Displacement measured by dynamic radiography appeared to be the time integral of the scalar product of the velocity vector and the vector normal to the surface area within the sensitive volume, i.e., that component of displacement of myocardial mass that was perpendicular to the surface of the myocardium. In other words, the dynamic radiographic signal was proportional to the mass of tissue within the sensitive volume. Good agreement in terms of absolute motion, its direction, and phase was noted between predicted dynamic radiographic signals and those observed. Thus validated, this technique was found to be reliable in quantifying motion abnormalities produced by acute coronary ligation.

Animals↗

Approximal caries depth assessment with storage phosphor versus film radiography. Evaluation of the caries-specific Oslo enhancement procedure.

OBJECTIVES: To study whether caries-specific enhancement of storage phosphor images might improve the observer performance of approximal caries depth assessments compared with film radiography. MATERIALS AND METHODS: 120 exposures were made of 120 extracted human teeth. To obtain geometrically identical images, Ektaspeed Plus films and storage phosphor plates were exposed simultaneously. The imaging plates were scanned in a Digora scanner and the files transferred to a different platform for image enhancement. Nine observers viewed films and storage phosphor images without provisions for adjustment of image intensity and contrast. For each imaging modality, 240 approximal surfaces were rated for caries on a 5-point confidence scale. Definite and probable caries lesions were also rated for lesion depth, and all ratings were compared with the histological state. Diagnostic accuracy was expressed as the area under the ROC curve (A(z) value). Paired t tests were used to compare the imaging modalities for diagnostic accuracy and F tests to compare observer variances. RESULTS: Enhanced storage phosphor images demonstrated significantly higher mean A(z) values than film (p = 0.0066). Significantly higher mean A(z) values were demonstrated in the outer half of enamel (p = 0.01), but no significant differences were found between the modalities for caries lesions penetrating beyond the outer half of the enamel. The number of correctly diagnosed true-positive surfaces with caries in outer enamel was significantly higher with storage phosphor images than with film (p = 0.00014). False-positive surfaces were most frequently registered in the outer enamel with both modalities, but in this region the number of false-positive surfaces was significantly higher with storage phosphor images than with film (p = 0.0038). Pooled sensitivity and specificity values were 0.48/0.94 and 0.61/0.86 for film and storage phosphor images, respectively. The interobserver variability was significantly lower for storage phosphor images than for film. CONCLUSION: Enhancement of storage phosphor images with a caries-specific procedure significantly improved the accuracy of caries depth assessments in the outer half of the enamel compared with film radiography and reduced observer variability.

Adult↗

Scintigraphy and chest radiography in the screening of pulmonary embolism after total hip replacement.

210 patients were screened for pulmonary embolism after total hip replacement with chest radiography and perfusion-ventilation scintigraphy using a new, dry 99mTc-microaerosol and a detailed system for coding scintigraphic abnormalities. Chest radiography did not contribute significantly to the diagnosis of pulmonary embolism. In spite of careful evaluation, false-negative and false-positive scintigraphic diagnoses of PE are still possible.

Evaluation Studies as Topic↗

Wavelength-dependent fibre-optic transillumination of small approximal caries lesions: the use of a dye, and a comparison to bitewing radiography.

The mere detection of caries lesions is insufficient for optimal treatment decision-making. Hence, the aim of this study was to investigate whether quantitative information about approximal lesion depth can be obtained from a technique based on the wavelength dependency of light propagation and additional use of a dye. Another aim was to compare the diagnostic performance of the optical technique and bitewing radiography. Measurements were performed on 33 extracted premolar teeth. Twelve proximal surfaces had white-spot, and 17 had discoloured small lesions. Four surfaces were sound. The teeth were transilluminated with a single glass fibre at the approximal surface before and after dye application. The occlusal surface was imaged with a CCD camera. Light in the blue and red part of the electromagnetic spectrum was selected using Schott glass filters. Average decadic optical thickness differences, delta bl-rd tau eff, were estimated and plotted as a function of normalised lesion depth, dhist, established from histological validation by two observers. The Spearman rank correlation was rs (delta bl-rd tau eff, dhist) = 0.87 (95% confidence interval, CI: 0.74-0.94). A marked increase in average decadic optical thickness in the blue part of the electromagnetic spectrum, delta dye tau eff, was observed for those lesion that, upon direct visual inspection of the approximal surface, clearly showed dye uptake. Bitewing radiographic depth ratings of two observers were plotted as a function of dhist. The correlations were rs (dRA,1, dhist) = 0.62 (95% CI: 0.34-0.80), rs (dRA,2, dhist) = 0.75 (95% CI: 0.54-0.87), and between the observers rs (dRA,1, dRA,2) = 0.44 (95% CI: 0.10-0.69). The p values of rs (delta bl-rd tau eff, dhist) -rs (dRA1,1, dhist) and rs (delta bl-rd tau eff, dhist) -rs (dRA,2, dhist) were p1 = 0.01 and p2 = 0.08, respectively. It was concluded that quantitative information about lesion depth can be obtained optically. The dye penetrates into only a limited number of caries lesions, in which cases dye uptake is detectable in transillumination geometry. Under laboratory circumstances the optical technique performs as well as bitewing radiography in the diagnosis of small approximal caries lesions.

Bicuspid↗

Ultrasonic examination: an alternative to chest radiography after central venous catheter insertion?

We evaluated ultrasonic examination as a diagnostic tool for catheter misplacement and pneumothorax after central venous catheter insertion. Physicians in the intensive care unit (ICU) performed the ultrasonic examinations, and the results were compared with those of chest radiography. Eighty-five central venous catheters (70 subclavian and 15 internal jugular) were inserted into 81 patients; 10 misplacements and one pneumothorax occurred. Ultrasonic examination feasibility was 99.6%. The only pneumothorax and all misplacements except one were diagnosed by ultrasound. Taking into consideration misplacements and pneumothorax research, ultrasonic examination did not give any false positive results. The mean time of the entire ultrasonic examination was 6.8 +/- 3.5 min, whereas 80.3 +/- 66.7 min were needed for the radiography (p < 0.0001). This study has suggested that ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is a rapid and accurate method that can be easily performed by ICU physicians.

Adult↗

Evaluation of intrathoracic extent of lung cancer by plain chest radiography, computed tomography, and magnetic resonance imaging.

A comparison was made of the ability of plain chest radiography, computed tomography (CT), and magnetic resonance imaging (MRI) to detect and assess the intrathoracic extent of lung cancer in 46 patients. The chest radiographs (CXR) were obtained with a high kilovoltage phototimed technique. The CT scans were obtained with a GE 9800 machine and the MRI studies with a 0.3 Tesla permanent magnet imaging system. The primary tumor was well demonstrated by all 3 imaging techniques; however, the configuration of lesions was best demonstrated by CT. MRI was superior to CXR and CT for demonstrating hilar involvement in 4 cases. CT and MRI were generally comparable for demonstrating mediastinal involvement but were superior to CXR. In 2 cases, small normal size nodes seen on CT were considered to be a single large abnormal node on MRI. Because of the paucity of signal from flowing blood, compression and displacement of vessels were easier to identify with MRI. In 1 case, a small pleural effusion was better seen with CT than with CXR or with MRI. Direct chest wall involvement in 1 case was not seen by CXR. Vertebral body abnormality in another case was seen only by MRI and not by CXR or CT. At present, MRI, with its long scanning time, motion degradation of the image, and poor spatial resolution, is inferior to CT for imaging lung cancer. For evaluation of intrathoracic extent of lung cancer, CT remains the procedure of choice after performing plain chest radiography.

Adult↗

Value of radiography in the management of possible fishbone ingestion.

A retrospective study was performed on 42 consecutive patients to examine the value of radiography in the management of complaints of fishbone ingestion. All patients underwent an oral examination followed by radiographic examination with plain films, barium swallows, barium and water swallows, and an endoscopic examination. All radiographs were reviewed by two unbiased, experienced radiologists. Of the 7 cases with fishbone found at endoscopic examination, only two (29%) bones were seen by the primary radiologist and 5 (71%) by the reviewing radiologists. Except for one case in which all three radiologists detected a fishbone that passed during the examination, and thereby was not found on endoscopy, no fishbones were found at the radiographic examination that were not seen on the endoscopic examination. Thus, radiography added no valuable information but only delayed the endoscopic examination with ensuing removal of the foreign body, which had to be performed regardless of the outcome of the radiographic examination. Therefore, we suggest that patients with a short history of complaints of fishbone ingestion, ie, 48 hours or less, should first be evaluated with oral and endoscopic examination.

Animals↗

Blurring and layer thickness in narrow beam rotation radiography.

The definition of the blurring of narrow beam rotation radiography is revived. The relative value of the blurring is considered to be the most reliable measurement. Calculations of the layer thickness should be based on the definition of the relative blurring. Experimental tests were performed, which confirm the mathematically presented hypothesis and also confirm the validity of the mathematical model of narrow beam rotation radiography presented by WELANDER (1974).

Mathematics↗

Radiography in primary tumors of the small bowel.

The value of radiography in patients with tumors of the small bowel was assessed retrospectively in 63 patients, who had been subjected to radiography, in a series of 118 patients treated for such tumors. Thirteen of 17 jejunal tumors (76%) and 19 of 46 ileal tumors (41%) were diagnosed preoperatively. Elective barium examination of the small bowel was performed in 36 patients, in whom the tumors were diagnosed in 18. When the small bowel examination was performed during obstruction, 7 of 21 tumors were diagnosed. With the barium examination, adenocarcinomas and carcinoid tumors were often diagnosed correctly. In 32 patients angiography was carried out, and the nature of the tumor was disclosed in 24 (75%).

Adenocarcinoma↗

A three-contrast, metal test pattern (Snellen E-plate) in evaluation of imaging techniques in clinical chest radiography.

A metal test pattern based on a minified Snellen-type E-plate was evaluated in testing six imaging techniques for chest radiography. The device consisted of three contrast zones and it was attached to the patient's back over the right lung during chest radiography. The values for visual detectability of the E-figures were compared with the film scores obtained by grading the radiographs with respect to visibility of diagnostically important anatomic details. The test plate proved to be a simple, quick and reproducible tool for testing several imaging techniques at the same time. The E-plate results were similar to those of the visual grading analysis in most respects. A few discrepancies existed, which were probably due to the inability of the test pattern to fully consider the effect of motion unsharpness and varying scattering conditions within the human thorax, as well as to great differences in roentgen ray absorption properties between Au and tissues.

Humans↗

Large-screen image intensifier photofluorography compared with full-size screen-film technique in chest radiography.

Large-screen image intensifier photofluorography revealed a radiation dose and exposure time of about one third of those of a medium speed rare-earth screen/film (Trimax T4/XD) combination for full-size chest radiography. The resolving power of the former technique is somewhat poorer and there is a moderate electron-òptical distortion in the peripheral field. In clinical chest radiography photospot films showed excellent demonstration of the central areas of the image but slight deterioration in peripheral parts. The minification effect of the photofluorographic films is advantageous for visual perception of many anatomic details on chest radiographs. The type of viewing device for photospot films is important.

Aged↗

Conventional radiography and ultrasonography in the diagnosis of small bowel obstruction and strangulation.

Ninety-six patients, 45 men and 51 women (mean age 39 years, range 13- 90 years), with clinically acute abdomen were examined by conventional abdominal radiography and ultrasonography during a period of one year. Ultrasonography was performed with a linear transducer, which permitted study of morphology and motility of small bowel loops: distention, paralysis, intramural thickening, and extraluminal fluid. Nineteen cases of mechanical obstruction (9 simple and 10 of strangulation type) were observed. In the strangulation group ultrasonographic findings were positive in 91% whereas conventional radiography solely was positive in 30%. In the simple obstruction, 89% and 78%, respectively, were correctly diagnosed by the 2 techniques. Ultrasonography is recommended as a routine examination beside conventional abdominal films in acute abdomen.

Adolescent↗

Ultrasound and soft-tissue radiography to monitor local interferon-alpha 2B treatment in Peyronie's disease.

PURPOSE: We attempted to assess objectively the response of Peyronie's disease plaques to local interferon-alpha 2B. MATERIAL AND METHODS: Twenty patients were treated with 5 local injections of 1 million units of IFN-alpha 2B into a single designated plaque. Before treatment, and 4 weeks and 6 months after treatment, the plaques were examined ultrasonographically. Each time, a histogram profile was performed. All patients also underwent soft-tissue radiography in 2 planes using the mammography technique before and 6 months after treatment. RESULTS: We found that with ultrasonography the plaques could be classified into 3 groups depending on degree of calcification, from nil to complete. Radiography detected calcifications better than ultrasonography but failed to detect plaques without calcification. The degree of calcification was negatively correlated with the response to treatment, since noncalcified plaques responded best, while fully calcified plaques failed to respond. CONCLUSION: In Peyronie's disease, ultrasonography is an important tool for non-invasive monitoring treatment response and for preselecting patients for medical treatment.

Follow-Up Studies↗

Digital subtraction radiography for longitudinal assessment of peri-implant bone change: method and validation.

The purpose of this paper is to present a digital subtraction technique for the assessment of peri-implant bone change over time in vivo. Digital subtraction radiography may be used to detect areas of bony change that have occurred between radiographic examinations, and image processing algorithms have been developed which can relate the magnitude of the change on the subtraction image to a reference wedge, thereby allowing calculation of the mass of the lesion. This manuscript will present two algorithms for the assessment of osseous change. The method was validated in monkeys by means of small bony chips placed intra-orally prior to the first radiograph. The chips were removed, a second radiograph taken, and the images subtracted. Each algorithm was used to isolate the lesion and calculate change in bone mass. Overall, there was excellent correlation between the calculated lesion mass (in milligrams) and actual lesion mass (r2 > 0.9). The utility of the method was demonstrated by comparison of the results of subtraction radiography in successful implants and in implants that did not integrate during the healing phase.

Absorptiometry, Photon↗

Quality assurance in orthodontic radiography.

The implementation of a Quality Assurance (QA) programme in orthodontic radiography is designed to improve the quality of the resultant radiographs and to reduce the number of repeat exposures. This is particularly desirable in orthodontic practice where the majority of patients are young and therefore more at risk from the detrimental effects of X-rays. A programme is described and QA tests are given that may be applied in the surgery. Particular emphasis is placed on QA measures for extraoral radiography, since this is frequently undertaken in the treatment of the orthodontic patient.

Equipment Design↗

Chest radiography and pneumonia in primary care: diagnostic yield and consequences for patient management.

The current prospective cohort study assessed the diagnostic yield of chest radiography (CXR) in primary-care patients suspected of pneumonia. In total, 192 patients with a clinical suspicion of pneumonia aged >/=18 yrs were referred by their general practitioner (GP) for CXR to one of the three participating hospitals in the Netherlands. All GPs were asked to complete a standardised form before and after CXR. Pneumonia was diagnosed by GPs in 35 (18%) patients, of whom 27 (14%) patients had a positive CXR, and eight (4%) patients a negative CXR, but with an assumed high probability of pneumonia by the GP. CXR clearly influenced the diagnosis of pneumonia by the GP in 53% of the patients. CXR ruled out pneumonia in 47% and the probability of pneumonia substantially increased in 6% of the patients. Patient management changed after CXR in 69% of the patients, mainly caused by a reduction in medication prescription (from 43 to 17%) and more frequent reassurance of the patient (from 8 to 35%). In conclusion, pneumonia was frequently over diagnosed clinically by general practitioners. Chest radiography is a valuable diagnostic tool to substantially reduce the number of patients misdiagnosed and is particularly important for the exclusion of pneumonia in general practice.

Adult↗

An evaluation of different imaging chains in clinical chest radiography.

Six imaging techniques in clinical chest radiography have been evaluated: four film-screen combinations in the conventional grid technique and two combinations in the air gap technique. Five parameters characterising the quality of a chest radiograph were evaluated by three radiologists and one chest physician by using a nominal grading scale from -2 to +2 compared with the standard technique. The quality parameters judged were: the visibility of peripheral lung vessels, lung parenchyme, the pulmonary hilum, and lung structure behind the heart shadow, as well as the visibility of miscellaneous findings of clinical interest. The air gap technique was shown to be superior to the ordinary grid technique. The diagnostic quality of chest radiography does not necessarily deteriorate with the screen speed. However, statistically significant differences were noticed, even between techniques which had equal speed and physical resolution.

Aged↗