Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

The influence of alumina and ultra-high molecular weight polyethylene particles on osteoblast-osteoclast cooperation.

Particle-induced macrophage activation, mainly by UHMWPE wear, has been recognized as the biological mechanism leading to periprosthetic bone resorption, which is responsible for the loosening of the total hip replacements (THR). Ceramic-on-ceramic implants have been advocated as a means of reducing wear products. Many studies investigated the effect of alumina (Al(2)O(3)) particles on monocytes/macrophages, but only limited information are available on their participation to bone turnover. An in vitro model was performed to investigate how Al(2)O(3) and UHMWPE particles may influence the osteoblast-osteoclast interaction: human osteoblasts (HOB) were obtained from trabecular bone, while osteoclasts were derived from peripheral blood mononuclear cells (PBMC) of healthy donors. The amount of IL6, TNF alpha, GM-CSF, and other factors acting on the bone turnover, i.e. the 'receptor activator of NF kappa B' ligand (RANKL) and osteoprotegerin (OPG), was detected in culture medium of particle-challenged HOB (HOB-CM). The Al(2)O(3) and UHMWPE particles did not affect either cell viability or TNF and GM-CSF release, while the increase in IL6 release seemed to be dependent on the particle concentration. UHMWPE increased the release of RANKL from HOB, while OPG and OPG-to-RANKL ratio were significantly inhibited. The ability of HOB-CM to promote osteoclastogenesis was tested via osteoblast/monocyte cooperation: after seven days of culture UHMWPE HOB-CM induced a large amount of multinucleated TRAP-positive giant cells, as well as significantly reduced the amount of IL6, GM-CSF and RANKL in the supernatant. With regard to the inductive effect on the osteoclastogenesis, our results show that the Al(2)O(3) wear debris are less active.

Aluminum Oxide↗

Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup.

A total of 391 edentulous maxillae and mandibles was consecutively treated with routine fixed prostheses, supported by 2,199 implants. The patients were followed for 1 year; the overall success rate was 99.5% and 98.1% for the prostheses and implants, respectively. The number of severe complications was low, but it was possible to identify a significantly higher ratio of problems in the maxillae throughout the observation period than for the mandibles. While many problems occurred in both the maxillae and mandibles, there were also problems more typical for each jaw. Diction and fractures of resin teeth were more common problems in maxillae; cheek and lip biting was a more frequent postinsertion complication in the treatment of mandibles. Most problems were easily resolved, and the retrievability of the prostheses was of great advantage.

Adult↗

Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study.

Ultrahigh molecular weight polyethylene (PE) cups with 0, 2.5, 50, 100, and 150 Mrad radiation treatments were run in a hip simulator for comparison of the microwear phenomena on the cup surfaces with the corresponding debris morphology. In general, the size and frequency of the PE surface fibrils and the size of the retrieved PE debris decreased with increasing radiation dose. The fibril size and shape on the cup surfaces were well correlated with the radiation dose. The fibrillar shape and size were found to be proportional to the square root of the radiation dose. However, the trend for size and shape factors of the wear debris related to the radiation dose was weak at best. Thus, the morphology of the PE fibrils on the cup surfaces was more sensitive to variations in the radiation dose than the actual wear debris. The wear response appeared to be a three-step process, which was dependent on the formation of surface nodules or ripples, the teasing out of surface fibrils, and the toughness of the PE matrix in releasing a wear fibril to form a debris particle. The tougher PE became with increasing radiation dose, the harder it was for the PE fibrils to break out into wear particles.

Arthroplasty, Replacement, Hip↗

Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation.

The purpose of this study was to evaluate the long-term wear performance of alumina matrix composite (AMC) heads against alumina matrix composite inserts and alumina matrix composite heads against alumina (Al) inserts with the use of a hip-joint simulator incorporating severe swing phase joint microseparation. The wear of AMC on Al produced an average wear rate of 0.61 mm3/million cycles over the 5-million-cycle test duration. The wear of AMC on AMC produced an average wear rate of 0.16 mm3/million cycles over the 5-million-cycle test duration. Both the AMC on alumina and AMC on AMC produced significantly lower wear than previously tested HIPed alumina, where an average wear rate of 1.84 mm3/million cycles was reported over 5 million cycles. The wear mechanisms and wear debris of AMC on AMC and AMC on Al were similar to those observed in previous alumina retrieval studies with stripe wear caused by intragranular fracture and wear debris consisting of predominantly uniform 10-20-nm-sized particles and a few irregular particles up to 3 microm in size.

Aluminum Oxide↗

Wear of dental resin composites: insights into underlying processes and assessment methods--a review.

Given the increased aesthetic demands of patients, along with improvements in the formulation of resin composites, the ability of these materials to bond to tooth structures, and concerns about dental amalgam fillings, the applicability of resin composites in dentistry has become increasingly widespread. As resistance to wear represents an important factor in determining the clinical success of resin composite restoratives, the aim of this article was to define what constitutes wear; the major underlying phenomena involved in this process-adhesion, abrasion, fatigue, and corrosion-being described. Discussions were also focused on factors that contribute both to the magnitude and minimization of resin composite wear. Finally, insights were included on both in vivo and laboratory studies used to determine wear resistance.

Animals↗

Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Osteolysis induced by ultra high molecular weight polyethylene wear debris is one of the primary factors limiting the lifespan of total hip replacements. Crosslinking polyethylene is known to improve its wear resistance in certain industrial applications, and crosslinked polyethylene acetabular cups have shown improved wear resistance in two clinical studies. In the present study, crosslinked polyethylene cups were produced by two methods. Chemically crosslinked cups were produced by mixing a peroxide with ultra high molecular weight polyethylene powder and then molding the cups directly to shape. Radiation-crosslinked cups were produced by exposing conventional extruded ultra high molecular weight polyethylene bar stock to gamma radiation at various doses from 3.3 to 100 Mrad (1 Mrad = 10 kGy), remelting the bars to extinguish residual free radicals (i.e., to minimize long-term oxidation), and then machining the cups by conventional techniques. In hip-joint simulator tests lasting as long as 5 million cycles, both types of cross-linked cups exhibited dramatically improved resistance to wear. Artificial aging of the cups by heating for 30 days in air at 80 degrees C induced oxidation of the chemically crosslinked cups. However, a chemically crosslinked cup that was aged 2.7 years at room temperature had very little oxidation. Thus, whether substantial oxidation of chemically crosslinked polyethylene would occur at body temperature remains unclear. The radiation-crosslinked remelted cups exhibited excellent resistance to oxidation. Because crosslinking can reduce the ultimate tensile strength, fatigue strength, and elongation to failure of ultra high molecular weight polyethylene, the optimal crosslinking dose provides a balance between these physical properties and the wear resistance of the implant and might substantially reduce the incidence of wear-induced osteolysis with total hip replacements.

Arthroplasty, Replacement, Hip↗

Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy.

A technique for the determination of titanium and zirconium in human blood serum, after pressurized digestion utilizing ICP-MS coupled to an ultrasonic nebulizer (USN) and desolvating membrane is described. As no CRM for titanium is available, zirconium has been determined in order to demonstrate the accuracy of the technique, as the limits in blood are well known. Bone cement consists basically of a polymer, namely polymethylmethacrylate (PMMA). For better X-ray contrast some manufacturers use incorporated ZrO2 with a volume fraction of 10 to 15%. Thus, the zirconium present in the PMMA matrix can be used as an indicator for the PMMA particulate debris.

Bone Cements↗

Fatigue failure in the cement mantle of an artificial hip joint.

The cement mantle of an artificial hip joint was retrieved, largely intact, during a revision operation, and subjected to detailed failure analysis. The results reveal a number of features which are important to our understanding of the failure of bone cement in situ and its consequences for prosthesis loosening. Microscopic examination showed clear evidence of fatigue cracking in the mantle prior to removal. This took the form of worn areas in certain regions of the fracture surfaces, which elsewhere showed evidence of rapid, brittle fracture. The mantle contained two large defects which had been introduced during insertion; fatigue was shown to have originated both from these defects and from the proximal surface. Results from a finite element analysis were used, together with the techniques of fracture mechanics, in an attempt to explain the magnitude and direction of fatigue cracking. Fracture mechanics calculations, though subject to some uncertainty in this case, indicate that the local stress intensity in the region of the principal defect would have been sufficient to exceed the threshold for fatigue crack propagation in this material. This approach demonstrates the advantages of this 'defect-tolerance' analysis.

Bone Cements↗

Gene expression clustering using self-organizing maps: analysis of the macrophage response to particulate biomaterials.

The most common cause of total joint replacement failure is peri-implant bone loss causing pain and prosthesis loosening. This process, known as osteolysis or aseptic loosening, is characterized by macrophage phagocytosis of particulate implant wear debris. In an incompletely defined step, particulate biomaterial debris induces macrophages to release a variety of inflammatory mediators and signaling proteins that lead to bone loss. In an in vitro model of this process, we used microarray technology and data analysis techniques, including the use of self-organizing maps (SOMs), to understand the mRNA gene expression changes occurring in macrophages exposed to clinically relevant particles of ultra-high molecular weight polyethylene and TiAlV alloy. Earlier studies have been limited by technology that only allowed analysis of a few genes at a time, but the microarray techniques used in this paper generate the quantitative analysis of over a thousand genes simultaneously. Our microarray analysis utilized an SOM clustering to elucidate general patterns in the data, lists of top up- and down-regulated genes for each time point and genes with differential expression under different biomaterial exposures. The expression levels of the majority of genes (>95%) did not vary over time or with exposure to different biomaterials, but a few important genes, such as TNF-alpha, IL-1beta, IL-6, and MIP1alpha, proved to be highly regulated in response to biomaterial exposure. We also uncovered a novel set of genes, which not only validates and logically extends the current model of the pathogenesis of osteolysis and aseptic loosening, but also provides new targets for further research and therapeutics.

Algorithms↗

The effect of patient gait on the material properties of UHMWPE in hip replacements.

The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) has been shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional, compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship between clinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within the UHMWPE acetabular component. Individual patients' wear paths were determined prior to revision operation from hip joint kinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revision operation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantify the orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient's clinical gait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affecting the wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.

Aged↗

Axillorenal arteriovenous graft: a new approach for dialysis access.

As the population requiring hemodialysis grows, it becomes increasingly common to encounter patients with limited options for vascular access. Because inability to secure vascular access is a life-threatening problem, it is important to consider all possible options in each patient. We report a new arteriovenous grafting procedure in which the left renal vein is used for outflow in a patient with multiple venous occlusions. Patency of the graft continues 18 months after placement. This graft carries acceptable morbidity, and can be revised. Consideration of this graft is appropriate in selected patients.

Arteriovenous Shunt, Surgical↗