Use of Medpor porous polyethylene implants in 140 patients with facial fractures.

Use of alloplastic materials in facial bone reconstruction is still controversial. Medpor porous polyethylene is a relatively new implant material that is well suited for this purpose and has a number of advantages over other alloplasts. It is a pure polyethylene with a unique manufacturing process and pore size. Technically, it is easy to work with; it can be carved, contoured, adapted, and fixated to obtain a precise three-dimensional construct. Physically, it is a pure, biocompatible, strong substance that does not resorb or degenerate. It demonstrates long-term stability, high tensile strength, resistance to stress and fatigue, and a virtual lack of surrounding soft-tissue reaction. Rapid tissue ingrowth occurs into the pores. Extensive vascular ingrowth creates the potential to transport cellular products that fight infection deep into the implant. The implant was used in 140 patients from June 1988 to August 1991 to treat acute orbitozygomatic injuries (71), acute Le Fort injuries (24), delayed orbitozygomatic injuries (33), and delayed onlay augmentation (12). In this series, there was 1 instance of implant infection requiring removal, and no implant migration, or exposure.

Adult↗

Plasma-treated lenowoven polyethylene ribbon for bone fixation at dentoalveolar osteotomy.

Plasma-treated lenowoven polyethylene ribbon was used for splinting between teeth around osteotomy lines in anterior segmental dentoalveolar osteotomy. This fixation was continued for 2 to 3 months, during which there was no damage or fall of the ribbon. In addition, the patients were able to eat their usual food, had much less pain in the teeth and oral mucosa, did not feel uncomfortable in the mouth, had no tooth damage or carious teeth, and had a good aesthetic appearance. In all eight jaws (five patients), accurate and strong bone fixation was achieved based on the planned occlusion. Patient complaints and pain were obviously less with this method than other methods. Polyethylene ribbon is quite useful for bone fixation in anterior segmental dentoalveolar osteotomy.

Adolescent↗

Comparing the osteogenic capacities of bone substitutes: hydroxyapatite, high-density porous polyethylene, and bone collagen: a biochemical and histological analysis.

Several inorganic materials have been shown previously to hold some osteogenic capacity. The purpose of this study is to compare the bone-forming abilities of hydroxyapatite ceramic, high-density porous polyethylene, and bone collagen within the periosteal island flap of rabbit tibia using histological and biochemical analysis. With this goal, four discrete experimental groups were formed, each comprising 22 New Zealand male rabbits. A sac was created on each rabbit tibial periosteum flap in each of the groups, and each of the previously mentioned materials was placed within this sac separately. One of these groups was thought as a control group without any material being placed inside the periosteal sac. Biopsies were taken at weeks 1, 2, 4, and 8 for biochemical analysis and at weeks 2 and 8 for histological evaluation. Neo-osteogenesis was evaluated quantitatively by determination of alkaline phosphatase and osteocalcin levels biochemically as well as by the percentage of new bone formation inside the periosteal sac histologically. Results show statistically that the osteogenic effect of high-density porous polyethylene is greater than that of the other materials used in this study (P < 0.05).

Analysis of Variance↗

Use of a polyethylene body jacket to prevent feeding tube removal in an agitated patient with anoxic encephalopathy.

UNLABELLED: Maintaining a feeding tube in place in the agitated patient following a traumatic brain injury or anoxic encephalopathy is a familiar problem. However, a survey of the literature employing the MEDLINE system provided no solutions. This case study of a 36-yr-old patient with anoxic encephalopathy illustrates a new method of preventing feeding tube removal using a modified polyethylene body jacket. The patient had repeatedly pulled out his gastrostomy tube despite the use of four-way restraints, a posey, behavior modification and anti-psychotic medications at levels near sedation. A polyethylene jacket with an S-shaped tunnel for feeding tube exit was constructed to cover the abdomen. FINDINGS: 1) The patient was unable to disturb the feeding tube. 2) The recessed design of the jacket's tunnel did not traumatize the feeding tube or obstruct fluid flow. 3) Nursing staff encountered no problems in placing or removing the orthosis. 4) Skin integrity was maintained. 5) The orthosis did not interfere with therapies.

Adult↗

Management of relative proptosis with a porous polyethylene orbital rim onlay implant.

PURPOSE: The position of the globe relative to the orbital rim plays a significant role in the relationship between the eyelids and the cornea. A prominent globe (relative proptosis) may cause eyelid retraction and exposure keratopathy. Simple horizontal lower eyelid tightening exacerbates eyelid retraction. Optimal correction with an orbital decompression or advancement of the orbital rim entails considerable risk. A technically simpler alternative, placement of an orbital rim onlay implant, was evaluated. METHODS: Fourteen patients with symptomatic relative proptosis underwent placement of a porous polyethylene orbital rim onlay implant. RESULTS: Lower eyelid position, exposure keratopathy, and ocular discomfort were improved in all patients. Two patients required minor surgical revisions. CONCLUSIONS: Porous polyethylene orbital rim onlay implants are a satisfactory option to treat the sequelae of relative proptosis.

Exophthalmos↗

Growth factors embedded in an agarose matrix enhance the rate of porous polyethylene implant biointegration.

PURPOSE: Repeated injections of epidermal and basic fibroblastic growth factors have been shown to enhance the biointegration rate of implanted porous polyethylene. A study was done to determine whether agarose, introduced at the time of implant placement, might serve as an adequate "single dose" delivery system for endogenous and exogenous growth factors. METHODS: Polyethylene cubes coated with agarose-containing growth factors were implanted into fat and muscle in rabbits. Factors studied included autogenous whole blood, autogenous serum, ascorbic acid, epidermal growth factor, basic fibroblast growth factor, transforming growth factor alpha, and transforming growth factor beta. The rate and character of the fibrovascular ingrowth into implants and surrounding capsule thickness were assessed. RESULTS: Fibroblast infiltration enhanced two- to sixfold with the use of autogenous or allogenic factors introduced in an agarose matrix at the time of cube implantation. CONCLUSIONS: Growth factors studied altered the thickness of the capsule surrounding implants as well as both the vascularity and stromal density within implants.

Adipose Tissue↗

High density polyethylene prosthetic femoral head replacemnt in the dog.

A high density polyethylene (RCH 1000) femoral head prosthesis was inserted in 5 large dogs. Periodic clinical and roentgenographic evaluations, and histopathological examination of the replaced joints as well as biomechanical evaluation of the prosthetic joints were done at intervals from 3 weeks to 15 months. HDP is NOT suitable for movable weight-bearing prosthesis articulating with cartilage or bone. Wear of the cartilage and the polyethylene occurred within a few weeks of function and became extensive proportionally to the length of use. The accumulating wear particles of HDP caused a significant foreign body granulomatous reaction which resulted in erosion of bone adjacent to the acetabulum in one hip.

Acetabulum↗

Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement.

A multicenter retrospective review was performed analyzing 1081 primary total hip replacements in 944 patients using the Harris Galante-I cementless acetabular component with screw fixation. All patients were followed up for a minimum of 5 years with a mean followup of 81 months. Linear polyethylene wear averaged 0.11 mm/year (range, 0-0.86 mm/year). Pelvic osteolysis was seen in 25 patients (2.3%). Migration of the acetabular component was seen in four hips. A subgroup of patients was reanalyzed at a minimum followup of 10 years. The mean linear polyethylene wear rate remained 0.11 mm/year. In this group, only one socket had migrated. There was an association between wear rate and age. On average, younger patients had higher wear rates. The risk for having pelvic osteolysis develop and the need for revision surgery also was age-related. Twenty-two percent of hip replacements (15 hips) in patients younger than 50 years of age at the time of their index operation had pelvic osteolysis develop. In contrast, for patients older than 50 years of age at the time of surgery only 7.8% (eight hips) had osteolysis of the pelvis develop. For patients older than 70 years of age at the time of primary total hip replacement, none had pelvic osteolysis develop.

Adolescent↗

Polyethylene liner dissociation with the Harris-Galante II acetabular component.

Dissociation of the polyethylene liner from its metal shell has been reported as a rare occurrence. During a 4-year period, six hips in five patients who had the Harris-Galante II porous acetabular component implanted as part of a primary or revision total hip arthroplasty presented with acute onset of pain and difficulty ambulating more than 2 years after surgery (range, 27-103 months). Radiographic evaluation revealed an eccentrically placed femoral head within the acetabular component. In patients whose acetabular shells were well-fixed, a polyethylene liner was cemented into the acetabular shell (four hips in three patients), and in one patient (one hip), the acetabular component was revised because of fracture of the metal shell. One patient who had a radiographically well-fixed component refused surgery (one hip). During a 4-year period, from 1990 to 1994, this implant was used resulting in a 2.6% incidence of dissociation. This case series is the largest of this complication for one prosthetic design.

Adult↗

Study of 222Rn permeation through polymer membranes II: calibration curves of a new device equipped with a polyethylene membrane, for continuous measurement of 222Rn in water-saturated soils.

The permeation of 222Rn through plastic membranes has been studied in order to improve a solid-state measuring device BARASOL and to use it in water-saturated soils. Preliminary results show that polyethylene is the most efficient membrane (sufficiently permeable to radon and impermeable to water). In the present study, we have adapted polyethylene membranes to the BARASOL probe and tested them, in this configuration, with a special experimental set-up. We have shown that it is possible to measure radon concentrations in water of about 1 Bq L(-1) with this probe.

Membranes, Artificial↗

Different fibrovascularization rate between coralline hydroxyapatite and high density porous polyethylene (Medpore) measured by 99mTc-MDP bone scintigraphy 6 months after intraorbital implantation.

Many materials and types of implant have been used to achieve a cosmetic effect and prosthesis motility in the anophthalmic socket. Hydroxyapatite remains the implant material of choice for producing the most natural prosthesis motility while porous polyethylene shows promising characteristics as another useful material. The aim of this study was to compare the fibrovascular ingrowth rates of orbital implants between coralline hydroxyapatite and high density porous polyethylene (Medpore). The fibrovascularization rate is determined by bone imaging using 99mTc methylene diphosphonate (99mTc-MDP) 6 months after implantation. Our study included 29 patients with coralline, and nine patients with Medpore implants. Our results showed that groups with coralline implants appearing to achieve complete fibrovascularization at a much more rapid rate than those with Medpore. The differences in rate were statistically significant.

Adolescent↗

Osteochondral reconstruction of a non-weight-bearing joint using a high-density porous polyethylene implant.

Currently, there is no reliable reconstructive modality allowing anatomic resurfacing of traumatic digital osteochondral articular defects. The purpose of the present study is to demonstrate the utility of Medpor, a high-density porous polyethylene (HDPP) scaffold biomaterial that can (1) be readily contoured to fit any joint defect, (2) permit stable internal fixation, and (3) permit osteocyte and chondrocyte ingrowth and subsequent articular cartilage resurfacing necessary to restore joint congruity. HDPP has gained wide acceptance for use in craniofacial and skeletal reconstruction and augmentation. An avian non-weight-bearing joint model was designed to study the role of the HDPP implant in small joint reconstruction. An osteochondral defect was created with a 5-mm circular punch in the humeral articular surface of both glenohumeral joints of 32 adult White Leghorn chickens. In each animal, one defect was press-fitted with a correspondingly sized HDPP implant (HDPP implant group); the contralateral defect was filled with the original osteochondral plug (isograft group) or left unrepaired (control group). At 2 weeks, and 1, 3, and 6 months,joints from each group were harvested and evaluated. Over the 6-month study period, joints in the control group demonstrated healing with dense collagenous scar tissue leaving residual defects at the articular surfaces and significant degenerative disease of the glenohumeral joints radiographically. Joints in the isograft group demonstrated near-complete resorption with some preservation of the cartilaginous cap but overall depression of the articular surface and significant degenerative joint disease. Joints in the HDPP implant group demonstrated stable fixation by highly mineralized bony trabecular ingrowth, preservation of the articular contour of the humeral head, and no evidence of significant degenerative joint disease. These findings indicate a potential role for this high-density porous polyethylene implant in the reconstruction of small joint articular and osseous defects.

Animals↗

Porous polyethylene implants in orbital floor reconstruction.

The purpose of this article is to present the authors' experience with the use of porous polyethylene ultrathin sheets for orbital floor reconstruction. Thirty-two patients with orbital floor fractures were treated with porous polyethylene ultrathin sheets. Sixteen cases corresponded to orbitozygomatic fractures, 11 cases corresponded to pure orbital floor fractures, and five corresponded to panfacial fractures. The subciliary approach was used in 15 patients and the transconjunctival approach in nine; another three patients were operated on through a preexisting eyebrow wound, two were operated on with a subtarsal approach, two were operated on through an eyebrow extension of a facial wound, and one patient was operated on through the facial wound. Intraoperatively, all patients received a prophylactic dose of intravenous antibiotics. Postoperatively, 24 patients received amoxicillin clavulanate for 5 to 7 days, two patients received clindamycin, and six patients received no antibiotics. Enophthalmos was corrected in 15 of 24 patients (62.5 percent), and hypoglobus in nine of 11 (82 percent). Diplopia was resolved in 25 of 28 patients (89.3 percent) with preoperative impairment. Extrinsic eye movement impairment was resolved in 25 of 27 patients (92.6 percent). A preoperative visual acuity deficit was present in four patients (12.5 percent) and was resolved in one (from 20/100 to 20/20). Visual acuity improved in one patient (from 20/60 to 20/30). In the other two patients, visual acuity remained altered (from 20/30 to 20/30). One patient (3.1 percent) suffered blindness induced by surgery. Nine of 26 patients (34.6 percent) had residual infraorbital nerve hypesthesia and five (19.2 percent) had residual paresthesias. Postoperatively, epiphora was present in six patients (18.8 percent) and ectropion in five (15.6 percent). Although there was no statistical significance between the surgical approach and the presence of epiphora (p = 0.211) and ectropion (p = 0.422), patients who were treated using the transconjunctival approach suffered reduced ectropion (0 percent) compared with patients treated using the subciliary approach (20 percent). However, patients treated using the transconjunctival approach suffered increased epiphora (22.2 percent) compared with those treated with the subciliary approach (13.3 percent). There were four cases (12.5 percent) of postoperative facial infections. Two of these cases were resolved with systemic antibiotics, one was resolved with bone sequestrum resection, and one patient needed removal of the implant. Orbital infections were related in all cases to titanium osteosynthesis miniplates or skull bone graft. When comparing patients who were treated with and without antibiotics, no statistical differences (p = 0.958) were found relative to the presence of infections. Correction of hypoglobus is technically easier than enophthalmos, because enophthalmic correction requires a wide, deep subperiosteal dissection and implant positioning, posterior to the equator of the globe, with the inherent risk of orbital apex injury.

Adolescent↗

Analysis of the control of the anti-gal immune response in a non-human primate by galactose alpha1-3 galactose trisaccharide-polyethylene glycol conjugate.

BACKGROUND: The current limitation to the clinical application of xenotransplantation using pig organs is a rejection process that has been termed delayed xenograft rejection or acute vascular rejection. It is thought that acute vascular rejection may be mediated at least in part by both the continued synthesis, of preexisting, and the induction, posttransplantation, of antibodies against the carbohydrate moiety galalpha1-3gal that is present on glycoproteins and glycolipids of the pig endothelium. The synthesis of these antibodies has proven difficult to control with currently available immunosuppressive agents. METHODS: We have synthesized galalpha1-3gal conjugated polyethylene glycol polymers that can bind to anti-galalpha1-3gal antibodies and tested their activity in non-human primates. RESULTS: These conjugates when administered to non-human primates can substantially reduce the levels of preexisting and control the induction of anti-galalpha1-3gal antibodies. The level of circulating antibody-secreting cells that make anti-galalpha1-3gal antibodies is also reduced. CONCLUSION: These alpha-gal polyethylene glycol conjugates may have the potential to control the anti-gal antibody response in a pig to primate organ transplant setting and may be a useful therapeutic agent in prolonging graft survival.

Animals↗

Oculoplastic and orbital applications of porous high-density polyethylene implants.

Porous high-density polyethylene implants have become well accepted for the repair of orbital wall fractures, delayed orbital reconstruction, orbital rim and malar bony onlay augmentation, and volume replacement as orbital spherical implants for the treatment of anophthalmos. Medpor (Porex Surgical, Inc. College Park, GA) is a commercially available porous high-density polyethylene product available in sheets, blocks, Flexblocks, several onlay contour shapes, spheres, and custom implants. Recently, the motility coupling post was introduced to provide an integrated Medpor spherical implant with enhanced prosthetic motility. Medpor implants possess several advantages over hydroxyapatite implants.

Biocompatible Materials↗

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and 11 medial pivot prostheses) under complete sterile conditions. Polyethylene particles were isolated and analyzed by scanning electron microscopy. Particle size (equivalent circle diameter) was 0.78 +/- 0.08 microm (mean +/- standard error) in posterior-stabilized prostheses and 0.67 +/- 0.06 microm in medial pivot prostheses. Particle shape (aspect ratio) was 2.30 +/- 0.22 in posterior-stabilized prostheses and 1.90 +/- 0.16 in medial pivot prostheses. The total numbers of particles were 1.16 +/- 0.57 x 10(8) in posterior-stabilized prostheses and 9.01 +/- 2.95 x 10(6) in medial pivot prostheses. Particles were smaller and rounder in medial pivot prostheses than in posterior-stabilized prostheses, but the differences were not significant. The difference in the common logarithm of particle number was significant. The medial pivot prosthesis generated less wear particles than the posteriorstabilized prosthesis, and these findings may have an impact on the incidence of osteolysis and aseptic loosening.

Arthroplasty, Replacement, Knee↗

The effects of external torque on polyethylene tibial insert damage patterns.

The forces and torques that occur during walking gait, particularly during toe-off, promote articulation in the posteromedial quadrant of tibial inserts. Retrieved components of failed knee arthroplasties show ultrahigh molecular weight polyethylene damage patterns in this region. Component-designed constraint, compromised polymer, and surgical factors account for these observations. The current authors compare the contact stresses that developed on four implant designs during toe-off for optimally aligned and externally torqued components using the finite element method. Under 16 N-m of torque, the four designs studied varied regarding their centers of rotation and magnitude of external rotation, which are related directly to their specific articulating surface geometry. Designs with conforming condylar geometry had greater rotational constraint and therefore, less external rotation. These conforming designs offer the benefits of lower stresses and tend to limit contact near the edge of the plateau. However, because of their increased rotational constraint, torque is transmitted more readily to the implant-bone interface, increasing the potential for implant loosening. The data presented serve as an indicator of the potential for polyethylene tibial component surface damage and define the role that implant geometry plays in resisting external rotation.

Finite Element Analysis↗

Metrology to quantify wear and creep of polyethylene tibial knee inserts.

Assessment of damage on articular surfaces of ultrahigh molecular weight polyethylene tibial knee inserts primarily has been limited to qualitative methods, such as visual observation and classification of features such as pitting, delamination, and subsurface cracking. Semiquantitative methods also have been proposed to determine the linear penetration and volume of the scar that forms on articular surfaces of tibial knee inserts. The current authors report a new metrologic method that uses a coordinate measuring machine to quantify the dimensions of this scar. The articular surface of the insert is digitized with the coordinate measuring machine before and after regular intervals of testing on a knee simulator. The volume and linear penetration of the scar are calculated by mathematically taking the difference between the digitized surface maps of the worn and unworn articular surfaces. Three conventional polyethylene tibial knee inserts of a posterior cruciate-sparing design were subjected to five million cycles of normal gait on a displacement-driven knee wear simulator in bovine serum. A metrologic method was used to calculate creep and wear contributions to the scar formation on each tibial plateau. Weight loss of the inserts was determined gravimetrically with the appropriate correction for fluid absorption. The total average wear volume was 43 +/- 9 and 41 +/- 4 mm3 measured by the metrologic and gravimetric methods, respectively. The wear rate averaged 8.3 +/- 0.9 and 8.5 +/- 1.6 mm3 per million cycles measured by the metrologic and gravimetric methods, respectively. These comparisons reflected strong agreement between the metrologic and gravimetric methods.

Equipment Failure Analysis↗