Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Azobenzene on Cu(110): adsorption site-dependent diffusion.

Azobenzene and its derivatives can undergo reversible trans-cis isomerizations when irradiated with light, making them potential candidates for optically sensitive materials and devices. The adsorption and diffusion of azobenzene on the Cu(110) surface was investigated with a variable-temperature scanning tunneling microscope. The trans-isomer was observed and found to occupy two adsorption geometries-an energetically stable and a metastable state. Diffusion occurred along the closed-packed [1 -1 0] direction of the surface, and the diffusivity for the two adsorption states was found to differ by approximately 1 order of magnitude.

Journal Article↗

Assembly of silica nanowires on silica aerogels for microphotonic devices.

We report on the assembly of low-loss silica nanowires into functional microphotonics devices on a low-index nondissipative silica aerogel substrate. Using this all-silica technique, we fabricated linear waveguides, waveguide bends, and branch couplers. The devices are significantly smaller than existing comparable devices and have low optical loss, indicating that the all-silica technique presented here has great potential for future applications in optical communication, optical sensing, and high-density optical integration.

Adsorption↗

The DICOM image formatting standard: its role in echocardiography and angiography.

Both echocardiography and angiography have traditionally used analog media for long-term storage, but increasingly there is the desire to develop digital storage and exchange methodology. Before digital storage can become a reality, though, standards must be agreed to by the vendor and user community to ensure global intra operability of medical instrumentation. To this end, the National Electrical Manufacturers' Association and various professional organizations from around the world have collaborated to develop the DICOM (Digital Imaging and Communications in Medicine) image formatting standard. This standard specifies the exact way in which digital images are exchanged between instruments, either using a network or storage medium, and distinct standards have been developed for angiography and echocardiography. In angiography, only gray scale images are considered, whereas in echocardiography several different types of image formats are allowed to account for color Doppler echocardiography. Distinct standards have also evolved for disk-based storage. For angiography, only storage on the writable CD-ROM is allowed, whereas echocardiograms may be stored on re-writable magneto-optical disks, floppy disks, and CD-ROMs. Only lossless compression is allowed in the angiographic standard, whereas echocardiography allows the use of the JPEG (Joint Photographic Expert Group) lossy compression algorithm. Currently, all major angiographic and echocardiographic vendors have agreed to support the DICOM standard, and products are beginning to appear, first with disk-based storage but increasingly with network-based exchange of image data.

Coronary Angiography↗

A comparison of video and digital data in the assessment of myocardial perfusion abnormalities by myocardial contrast echocardiography.

OBJECTIVE: The objective of the present study was to compare the digital and video data of myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses. METHODS: Three grades of left anterior descending (LAD) coronary artery stenosis and occlusion were created in eight open-chest canine models. MCE was performed with BR1 infusion by harmonic power Doppler with ECG gated intermittent triggered imaging at pulsing intervals ranging from 1:1 to 1:10. For images that were recorded simultaneously on both a videotape (video data) and an optical disk (digital data), myocardial signal intensity in the LAD region was plotted vs. pulsing intervals and was fitted to an exponential function: y = A(1 - e(-bt)), where A is the peak plateau signal intensity, and b is the rate of signal intensity rise for quantification of myocardial blood flow. RESULTS: Both values for A and b progressively decreased with a greater level of stenosis. The correlation of A with myocardial blood flow (determined by use of fluorescent microspheres) was weak with digital data (r = 0.38, p = 0.037), and was insignificant with video data (r = 0.16, p = 0.38). The correlation of b with microsphere-derived myocardial blood flow was better than that of A with both video and digital data, and was similar between the two kinds of data (video: r = 0.69, p < 0.0001; digital: r = 0.68, p < 0.0001). CONCLUSIONS: Video and digital MCE data are equivalent in their ability to quantify altered myocardial blood flow produced by graded coronary stenoses.

Analysis of Variance↗

Large-scale synthesis of a silicon photonic crystal with a complete three-dimensional bandgap near 1.5 micrometres

Photonic technology, using light instead of electrons as the information carrier, is increasingly replacing electronics in communication and information management systems. Microscopic light manipulation, for this purpose, is achievable through photonic bandgap materials, a special class of photonic crystals in which three-dimensional, periodic dielectric constant variations controllably prohibit electromagnetic propagation throughout a specified frequency band. This can result in the localization of photons, thus providing a mechanism for controlling and inhibiting spontaneous light emission that can be exploited for photonic device fabrication. In fact, carefully engineered line defects could act as waveguides connecting photonic devices in all-optical microchips, and infiltration of the photonic material with suitable liquid crystals might produce photonic bandgap structures (and hence light-flow patterns) fully tunable by an externally applied voltage. However, the realization of this technology requires a strategy for the efficient synthesis of high-quality, large-scale photonic crystals with photonic bandgaps at micrometre and sub-micrometre wavelengths, and with rationally designed line and point defects for optical circuitry. Here we describe single crystals of silicon inverse opal with a complete three-dimensional photonic bandgap centred on 1.46 microm, produced by growing silicon inside the voids of an opal template of dose-packed silica spheres that are connected by small 'necks' formed during sintering, followed by removal of the silica template. The synthesis method is simple and inexpensive, yielding photonic crystals of pure silicon that are easily integrated with existing silicon-based microelectronics.

Journal Article↗

Proteomic applications of surface plasmon resonance biosensors: analysis of protein arrays.

Proteomics is one of the most important issues in the post-genomic area, because it can greatly contribute to identifying protein biomarkers for disease diagnosis and drug screening. Protein array is a key technology for proteome researches and has been analyzed by various methods including fluorescence, mass spectrometry, atomic force microscopy and surface plasmon resonance (SPR). SPR biosensor is a promising technology in proteomics, since it has various advantages including real-time measurement of biomolecular interactions without labeling and the simple optical system for the device. SPR biosensors have a strong potential for analyzing proteomes by SPR imaging and SPR spectroscopic imaging, even though the challenge is to produce proteins on a proteomic scale.

Animals↗

Comparative antiplatelet effects of aspirin, vapiprost and GR144053, a GPIIb/IIIa antagonist, with a special reference to the role of platelet microaggregates.

Microthrombi produced have a potential to form larger thrombi, leading to vascular occlusions. Recently, a new device to easily detect microaggregates using laser-light scattering (LS) has been developed. We adopted this device to comparatively evaluate the inhibitory effects of aspirin (1,3 or 10 mg kg(-1)), vapiprost (0.3, 1 or 3 mg kg(-1)) or GR144053 (0.1, 0.3 or 1 mg kg(-1)) on ex vivo aggregation of hamster platelets in relation to their in vivo antithrombotic effects. A transluminal thrombus was produced in the hamster femoral artery by the photochemical reaction. Each compound was injected i.v. as a bolus 10 min prior to the reaction, showing a dose-dependent antithrombotic effect, i.e. they prolonged the time before the artery occluded. At that time cyclic flow reductions occurred more marked when aspirin or vapiprost was given. At the end of experiments, blood was collected to evaluate the platelet aggregation using both the new LS device and the conventional optical density (OD) method. Many more small aggregates were still formed when the highest dose of aspirin or vapiprost was used as compared with that of GR144053, although suppression of the platelet aggregation using the OD method, prolongation of the occlusion time and the bleeding time were quite similar. In conclusion, a GPIIb/IIIa antagonist markedly suppressed the microthrombi and reduced the cyclic flow reduction. This further indicates the importance of small aggregates as triggers of thrombosis and shows that prevention of their formation may result in improved vascular patency after thrombotic insult.

Animals↗

Integration of a picture archiving and communication system with videocapture and computed radiography in a dental hospital.

A method for the integration of a picture archiving and communication system (PACS) at Kyushu University Dental Hospital with radiological information (RIS) and hospital information (HIS) systems is described. CT, US and DSA from different manufacturers were integrated by videocapture and then subsequently integrated with computed radiography (CR) by means of DICOM. The approximate amount of data stored each month on optical discs is 2 GB. The system does not incorporate intra-oral radiography.

Angiography, Digital Subtraction↗

Optimization of poly(dimethylsiloxane) hollow prisms for optical sensing.

A new generation of simple, robust and compact microfluidic systems with optical readout is presented. The devices consist of hollow prisms fabricated by soft-lithography, together with microlenses and self-aligned channels for fibre optic positioning, conferring the system with a high degree of monolithic integration. Its working principle is based on the absorption of the working wavelength (lambda = 460 nm) by the different substances that can fill the hollow prisms. By modifying the volumes and geometries, optimization of the presented systems has been achieved. Results show how the limit of detection (LOD) for fluorescein and methylorange diluted in phosphate buffer can be significantly lowered, by increasing the size of the prism or increasing the total deviation angle. For our investigations we used concentrations for which the Beer-Lambert law is fulfilled and the measurements showed a LOD in the microM range for both species. Finally, since the change in the fractions of the methylorange as a function of the pH causes a variation of the total absorption of the solution, the hollow prisms have also been used for pH measurements.

Absorption↗

Nano-chemistry and scanning probe nanolithographies.

The development of nanometer-scale lithographies is the focus of an intense research activity because progress on nanotechnology depends on the capability to fabricate, position and interconnect nanometer-scale structures. The unique imaging and manipulation properties of atomic force microscopes have prompted the emergence of several scanning probe-based nanolithographies. In this tutorial review we present the most promising probe-based nanolithographies that are based on the spatial confinement of a chemical reaction within a nanometer-size region of the sample surface. The potential of local chemical nanolithography in nanometer-scale science and technology is illustrated by describing a range of applications such as the fabrication of conjugated molecular wires, optical microlenses, complex quantum devices or tailored chemical surfaces for controlling biorecognition processes.

Journal Article↗

Quenched disorder in a liquid-crystal biosensor: adsorbed nanoparticles at confining walls.

We analyze the response of a nematic liquid-crystal film, confined between parallel walls, to the presence of nanoscopic particles adsorbed at the walls. This is done for a variety of patterns of adsorption (random and periodic) and operational conditions of the system that can be controlled in experimental liquid-crystal-based devices. We compute simulated optical textures and the total optical output of the sensor between crossed polars, as well as the correlation function for the liquid-crystal tensor order parameter; we use these observables to discuss the gradual destruction of the original uniform orientation. For large concentrations of particles adsorbed in random patterns, the liquid crystal at the center of the sensor adopts a multidomain state, characterized by a small correlation length of the tensor order parameter, and also by a loss of optical anisotropy under observation through crossed polars. In contrast, for particles adsorbed in periodic patterns, the nematic at the center of the cell can remain in a monodomain orientation state, provided the patterns in opposite walls are synchronized.

Adsorption↗

Simulation of radiation effects on three-dimensional computer optical memories.

A model was developed to simulate the effects of heavy charged-particle (HCP) radiation on the information stored in three-dimensional computer optical memories. The model is based on (i) the HCP track radial dose distribution, (ii) the spatial and temporal distribution of temperature in the track, (iii) the matrix-specific radiation-induced changes that will affect the response, and (iv) the kinetics of transition of photochromic molecules from the colored to the colorless isomeric form (bit flip). It is shown that information stored in a volume of several nanometers radius around the particle's track axis may be lost. The magnitude of the effect is dependent on the particle's track structure.

Biophysical Phenomena↗

Nonvolatile read-out molecular memory.

A versatile molecule is described that performs as a nondestructible read-out optical-storage molecular memory. This molecular memory is composed of two distinct molecules that are chemically bonded to each other to form a single molecule with unique properties. One component is a photochromic fulgimide, and the other is a strongly fluorescing oxazine dye. This composite molecule was specifically designed and synthesized to display, under specific conditions, both the photochromic functions of the first component and the fluorescence properties of the dye. To store information, the polar, closed form of the photochromic component is illuminated with 530-nm light, which converts it to the open, nonpolar form. The information is accessed by excitation at the 650-nm band of the oxazine dye component, causing the dye to fluoresce. However, the dye emits intense fluorescence under a nonpolar environment, which is attained only when the fulgimide component is in its open, nonpolar structure. The ultrafast kinetics, spectroscopy, and mechanism of the photoreaction of this molecule and its photoinduced intermediates have been measured, and fluorescence quantum yields and cross sections were determined.

Coloring Agents↗

From papyrus to compact disc: the microbial deterioration of documentary heritage.

Highly significant evidence of the intellectual and cultural efforts of the human race is contained in documents. They take many forms, from papyri through paper to modern magnetic media and optical records. These items are mainly made of organic materials many of which contain polymers, which span from cellulose and its derivatives to synthetic resins. As with other manmade objects, however, documentary heritage is susceptible to chemical, physical, and biological damage. For the colonization and establishment of any biological community, the composition of materials used, their status of conservation, and environmental and climatic factors, such as temperature and humidity, are important elements to take into account. This article covers the scientific investigation of microbial degradation of documents, which is one of the most serious and underappreciated sources of damage to library and archival materials. In particular, although less known, modern records, including compact discs, are also subjected to biodeterioration. Archival and library material preservation broadly encompasses those activities and functions designed to produce a suitable and safe environment that extends the life of collections in useable condition for as long as is feasible. In the literature quoted, key information is also provided to avoid or limit microbial growth and some conservation treatments are also reported.

Animals↗

Teleophthalmology link between a primary health care centre and a reference hospital.

We have evaluated a teleophthalmology service linking a primary health care centre and an eye clinic at a reference hospital. General practitioners at the primary care centre serving a population of 15,000 and ophthalmologists at the reference hospital participated in this study. Eye fundus digital images were taken from 278 eye fundi of 139 consecutive patients with clinical conditions that could potentially produce fundus alterations. Fundus images were obtained with a non-mydriatic fundus camera (Canon CR6-45M) and were electronically sent reference hospital where ophthalmologist inspected the images and returned the diagnosis. In 18 patients (13%) the images did not have good enough quality to exclude eye fundus lesions. In 24 patients (17%) clear eye fundus alterations were found in at least one eye. In 14 patients (10%) there were image features suggesting retinal alterations that could not be confirmed by image inspection. Media opacity (13 eyes, 5%, seven patients, 5%) was the most common cause of poor image quality. The most difficult assessment was the evaluation of optic nerve head cupping. Retinal oedema was not observable in the digital images. In our experience teleopthalmology services seem to be an effective alternative for eye fundus diagnosis and patient follow-up.

Computer Communication Networks↗