Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Detection of Ralstonia solanacearum strains with a quantitative, multiplex, real-time, fluorogenic PCR (TaqMan) assay.

A fluorogenic (TaqMan) PCR assay was developed to detect Ralstonia solanacearum strains. Two fluorogenic probes were utilized in a multiplex reaction; one broad-range probe (RS) detected all biovars of R. solanacearum, and a second more specific probe (B2) detected only biovar 2A. Amplification of the target was measured by the 5' nuclease activity of Taq DNA polymerase on each probe, resulting in emission of fluorescence. TaqMan PCR was performed with DNA extracted from 42 R. solanacearum and genetically or serologically related strains to demonstrate the specificity of the assay. In pure cultures, detection of R. solanacearum to >/=10(2) cells ml(-1) was achieved. Sensitivity decreased when TaqMan PCR was performed with inoculated potato tissue extracts, prepared by currently recommended extraction procedures. A third fluorogenic probe (COX), designed with the potato cytochrome oxidase gene sequence, was also developed for use as an internal PCR control and was shown to detect potato DNA in an RS-COX multiplex TaqMan PCR with infected potato tissue. The specificity and sensitivity of the assay, combined with high speed, robustness, reliability, and the possibility of automating the technique, offer potential advantages in routine indexing of potato tubers and other plant material for the presence of R. solanacearum.

Betaproteobacteria↗

Simultaneous detection of Aeromonas salmonicida, Flavobacterium psychrophilum, and Yersinia ruckeri, three major fish pathogens, by multiplex PCR.

A multiplex PCR assay based on the 16S rRNA genes was developed for the simultaneous detection of three major fish pathogens, Aeromonas salmonicida, Flavobacterium psychrophilum, and Yersinia ruckeri. The assay proved to be specific and as sensitive as each single PCR assay, with detection limits in the range of 6, 0.6, and 27 CFU for A. salmonicida, F. psychrophilum, and Y. ruckeri, respectively. The assay was useful for the detection of the bacteria in artificially infected fish as well as in fish farm outbreaks. Results revealed that this multiplex PCR system permits a specific, sensitive, reproducible, and rapid method for the routine laboratory diagnosis of infections produced by these three bacteria.

Aeromonas↗

Use of multiplex PCR and PCR restriction enzyme analysis for detection and exploration of the variability in the free-living amoeba Naegleria in the environment.

A multiplex PCR was developed to simultaneously detect Naegleria fowleri and other Naegleria species in the environment. Multiplex PCR was also capable of identifying N. fowleri isolates with internal transcribed spacers of different sizes. In addition, restriction fragment length polymorphism analysis of the PCR product distinguished the main thermophilic Naegleria species from the sampling sites.

Animals↗

Detection and enumeration of aromatic oxygenase genes by multiplex and real-time PCR.

Our abilities to detect and enumerate pollutant-biodegrading microorganisms in the environment are rapidly advancing with the development of molecular genetic techniques. Techniques based on multiplex and real-time PCR amplification of aromatic oxygenase genes were developed to detect and quantify aromatic catabolic pathways, respectively. PCR primer sets were identified for the large subunits of aromatic oxygenases from alignments of known gene sequences and tested with genetically well-characterized strains. In all, primer sets which allowed amplification of naphthalene dioxygenase, biphenyl dioxygenase, toluene dioxygenase, xylene monooxygenase, phenol monooxygenase, and ring-hydroxylating toluene monooxygenase genes were identified. For each primer set, the length of the observed amplification product matched the length predicted from published sequences, and specificity was confirmed by hybridization. Primer sets were grouped according to the annealing temperature for multiplex PCR permitting simultaneous detection of various genotypes responsible for aromatic hydrocarbon biodegradation. Real-time PCR using SYBR green I was employed with the individual primer sets to determine the gene copy number. Optimum polymerization temperatures for real-time PCR were determined on the basis of the observed melting temperatures of the desired products. When a polymerization temperature of 4 to 5 degrees C below the melting temperature was used, background fluorescence signals were greatly reduced, allowing detection limits of 2 x 10(2) copies per reaction mixture. Improved in situ microbial characterization will provide more accurate assessment of pollutant biodegradation, enhance studies of the ecology of contaminated sites, and facilitate assessment of the impact of remediation technologies on indigenous microbial populations.

Bacteria↗

Multiplex real-time PCR for monitoring Heterobasidion annosum colonization in Norway spruce clones that differ in disease resistance.

A multiplex real-time PCR assay was developed to monitor the dynamics of the Picea abies-Heterobasidion annosum pathosystem. Tissue cultures and 32-year-old trees with low or high resistance to this pathogen were used as the host material. Probes and primers were based on a laccase gene for the pathogen and a polyubiquitin gene for the host. The real-time PCR procedure was compared to an ergosterol-based quantification method in a tissue culture experiment, and there was a strong correlation (product moment correlation coefficient, 0.908) between the data sets. The multiplex real-time PCR procedure had higher resolution and sensitivity during the early stages of colonization and also could be used to monitor the host. In the tissue culture experiment, host DNA was degraded more rapidly in the clone with low resistance than in the clone with high resistance. In the field experiment, the lesions elicited were not strictly proportional to the area colonized by the pathogen. Fungal colonization was more restricted and localized in the lesion in the clone with high resistance, whereas in the clone with low resistance, the fungus could be detected until the visible end of the lesion. Thus, the real-time PCR assay gives better resolution than does the traditionally used lesion length measurement when screening host clones for resistance.

Basidiomycota↗

Comparison of total culturable virus assay and multiplex integrated cell culture-PCR for reliability of waterborne virus detection.

The total culturable virus assay (TCVA) and an integrated cell culture-PCR (ICC-PCR) were compared in parallel to evaluate their detection reliability. Source, finished, and tap water samples from three drinking water treatment plant systems were analyzed by TCVA, and every cell culture dish was subsequently examined by reverse transcription (RT) multiplex PCR using enterovirus- and adenovirus-specific primers. Twenty-seven of 180 (15%) inoculated dishes exhibited cytopathic effects (CPE). Virus concentrations for source water ranged from 3.3 to 21.0 most probable numbers of infectious units (MPN) per 100 liters. No finished or tap water samples were positive. On the other hand, 38 (21%) of the dishes were positive in multiplex ICC-PCR. Virus concentrations ranged from 4.5 to 10.2 MPN/100 liters for source water and 0 to 0.9 MPN/100 liters for finished and tap water. In spite of its superior sensitivity, the ICC-PCR assay resulted in lower virus concentration values than the TCVA for two of the source water sites. Retest of the CPE-positive dishes using reovirus-specific RT-PCR revealed that 24 of the 27 (89%) dishes were also positive for reoviruses. These observations suggested that the detection reliability of ICC-PCR is restricted by the primer sets that are integrated in the reaction mixture. The observation of an uneven distribution of PCR-positive culture dishes in a given sample raises an additional caution that simple extrapolation of the ICC-PCR result from the analysis of a limited fraction of collected samples should be avoided to minimize possible over- and underestimation of the amount of virus.

Adenoviridae↗

Detection of Vibrio parahaemolyticus in shellfish by use of multiplexed real-time PCR with TaqMan fluorescent probes.

We developed a multiplexed real-time PCR assay using four sets of gene-specific oligonucleotide primers and four TaqMan probes labeled with four different fluorophores in a single reaction for detection of total and pathogenic Vibrio parahaemolyticus, including the pandemic O3:K6 serotype in oysters. V. parahaemolyticus has been associated with outbreaks of food-borne gastroenteritis caused by the consumption of raw or undercooked seafood and therefore is a concern to the seafood industry and consumers. We selected specific primers and probes targeting the thermostable direct hemolysin gene (tdh) and tdh-related hemolysin gene (trh) that have been reported to be associated with pathogenesis in this organism. In addition, we targeted open reading frame 8 of phage f237 (ORF8), which is associated with a newly emerged virulent pandemic serotype of V. parahameolyticus O3:K6. Total V. parahaemolyticus was targeted using the thermolabile hemolysin gene (tlh). The sensitivity of the combined four-locus multiplexed TaqMan PCR was found to be 200 pg of purified genomic DNA and 10(4) CFU per ml for pure cultures. Detection of an initial inoculum of 1 CFU V. parahaemolyticus per g of oyster tissue homogenate was possible after overnight enrichment, which resulted in a concentration of 3.3x10(9) CFU per ml. Use of this method with natural oysters resulted in 17/33 samples that were positive for tlh and 4/33 samples that were positive for tdh. This assay specifically and sensitively detected total and pathogenic V. parahaemolyticus and is expected to provide a rapid and reliable alternative to conventional detection methods by reducing the analysis time and obviating the need for multiple assays.

Animals↗

Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins.

Recently, the Centers for Disease Control and Prevention reported an accurate, sensitive, specific, reproducible, and quantitative enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) antibodies to Bacillus anthracis protective antigen (PA) in human serum (C. P. Quinn, V. A. Semenova, C. M. Elie et al., Emerg. Infect. Dis. 8:1103-1110, 2002). The ELISA had a minimum detectable concentration (MDC) of 0.06 microgram/ml, which, when dilution adjusted, yielded a whole-serum MDC of 3.0 micro g of anti-PA IgG per ml. The reliable detection limit (RDL) was 0.09 microgram/ml, while the dynamic range was 0.06 to 1.7 microgram/ml. The diagnostic sensitivity of the assay was 97.6% and the diagnostic specificity was 94.2% for clinically verified cases of anthrax. A competitive inhibition anti-PA IgG ELISA was also developed to enhance the diagnostic specificity to 100%. We report a newly developed fluorescence covalent microbead immunosorbent assay (FCMIA) for B. anthracis PA which was Luminex xMap technology. The FCMIA MDC was 0.006 microgram of anti-PA IgG per ml, the RDL was 0.016 microgram/ml, and the whole-serum equivalent MDC was 1.5 micrograms/ml. The dynamic range was 0.006 to 6.8 microgram/ml. Using this system, we analyzed 20 serum samples for anti-PA IgG and compared our results to those measured by ELISA in a double-masked analysis. The two methods had a high positive correlation (r2 = 0.852; P < 0.001). The FCMIA appears to have benefits over the ELISA for the measurement of anti-PA IgG, including greater sensitivity and speed, enhanced dynamic range and reagent stability, the use of smaller sample volumes, and the ability to be multiplexed (measurement of more than one analyte simultaneously), as evidenced by the multiplexed measurement in the present report of anti-PA and anti-lethal factor IgG in serum from a confirmed clinical anthrax infection.

Adult↗

Simplified fluorescent multiplex PCR method for evaluation of the T-cell receptor V beta-chain repertoire.

RATIONALE: Evaluation of the T-cell receptor (TCR) V beta-chain repertoire by PCR-based CDR3 length analysis allows fine resolution of the usage of the TCR V beta repertoire and is a sensitive tool to monitor changes in the T-cell compartment. A multiplex PCR method employing 24 labeled upstream V beta primers instead of the conventionally labeled downstream C beta primer is described. METHOD: RNA was isolated from purified CD4 and CD8 T-cell subsets from umbilical cord blood and clinical samples using TRI reagent followed by reverse transcription using a C beta primer and an Omniscript RT kit. The 24 V beta primers were multiplexed based on compatibility and product sizes into seven reactions. cDNA was amplified using 24 V beta primers (labeled with tetrachloro-6-cardoxyfluorescein, 6-carboxyfluorescein, and hexachloro-6-carboxyfluorescein), an unlabeled C beta primer, and Taqgold polymerase. The fluorescent PCR products were resolved on an automated DNA sequencer and analyzed using the Genotyper 2.1 software. RESULTS: V beta spectratypes of excellent resolution were obtained with RNA amounts of 250 ng using the labeled V beta primers. The resolution was superior to that obtained with the labeled C beta primer assay. Also the numbers of PCRs were reduced to 7 from the 12 required in the C beta labeling method, and the sample processing time was reduced by half. CONCLUSION: The method described for T-cell receptor V beta-chain repertoire analysis eliminates tedious dilutions and results in superior resolution with small amounts of RNA. The fast throughput makes this method suitable for automation and offers the feasibility to perform TCR V beta repertoire analyses in clinical trials.

CD4 Antigens↗

Blinded multiplex PCR analyses of middle ear and nasopharyngeal fluids from chinchilla models of single- and mixed-pathogen-induced otitis media.

Multiplex PCR analyses for both bacterial and viral pathogens were conducted in a blinded manner on 33 archival specimens, of known culture status, procured from chinchilla models of both single- and mixed-pathogen-induced otitis media and from a pediatric patient. These specimens had been maintained at -70 degrees C for up to 6 years. Experimental specimens evaluated included middle-ear effusions, nasopharyngeal lavage fluids and middle-ear lavage fluids from animals which were immunologically naive, sham-immunized or actively immunized with nontypeable Haemophilus influenzae antigens. Sampling times used ranged from the day of bacterial or viral challenge to 42 days after challenge. Initial PCR analyses of the 33 specimens matched the traditional culture data in 24 instances (73%), correctly identifying nontypeable H. influenzae, Moraxella catarrhalis, Streptococcus pneumoniae, or adenovirus as the causative agent. A PCR-positive signal for the microbe(s) inoculated was also obtained in four animal model specimens (12%) which were culture negative. One of two culture-negative human effusions was also PCR positive. Thus, overall, results obtained by blinded PCR were 85% concordant with traditional culture methods or correctly indicated the specific pathogen introduced in four specimens that were sterile. In no instance was a false-positive signal obtained for any of the five etiologic agents being evaluated. We conclude that the multiplex PCR analyses are rapid and accurate methodologies when they are used to retrospectively evaluate diverse archival specimens of limited volume from experimental models of otitis media.

Adenoviridae↗

Comparison of a multiplex flow cytometric assay with enzyme-linked immunosorbent assay for auantitation of antibodies to tetanus, diphtheria, and Haemophilus influenzae Type b.

We developed a multiplexed indirect immunofluorescence assay for antibodies to Haemophilus influenza type b (Hib) polysaccharide and the toxoids of Clostridium tetani (Tet) and Corynebacterium diphtheriae (Dip) based on the Luminex multiple-analyte profiling system. A pooled serum standard was calibrated against World Health Organization standards for Dip and Tet and an international standard for Hib. The multiplexed Luminex assay was compared to individual enzyme-linked immunosorbent assays (ELISAs) for the same analytes. By both methods, 75 (92.6%) of 81 of random serum samples had protective levels of antibody to Tet (> or = 0.1 IU/ml). For Dip, 81.5% of the samples had protective antibody levels (> or = 0.1 IU/ml) by ELISA and 80.2% had protective antibody levels by Luminex. Protective levels (> or = 1.0 microg/ml) of antibody to Hib were found in 45.0% of the samples tested by ELISA and in 39.0% of the samples tested by Luminex. The correlations (R(2)) between ELISA and Luminex of the 81 samples were 0.96, 0.96, and 0.91 for Tet, Dip, and Hib, respectively. There was also similar agreement between Luminex and ELISA for sera collected before and 1 month after Tet, Dip, and Hib vaccine administration. Both methods detected strong postvaccination responses. The Luminex method is an attractive alternative to ELISA since it reduces labor and reagent costs, as well as assay time.

Antibodies↗

Detection of multidrug-resistant Salmonella enterica serovar typhimurium phage types DT102, DT104, and U302 by multiplex PCR.

Salmonella enterica serovar Typhimurium is a common cause of nontyphoidal salmonellosis in humans and animals. Multidrug-resistant serovar Typhimurium phage type DT104, which emerged in the 1990s, has become widely distributed in many countries. A total of 104 clinical isolates of Salmonella serogroup B were collected from three major hospitals in Taiwan during 1997 to 2003 and were examined by a multiplex PCR targeting the resistance genes and the spv gene of the virulence plasmid. A total of 51 isolates (49%) were resistant to all drugs (ACSSuT [resistance to ampicillin, chloramphenicol, streptomycin, sulfonamide, and tetracycline]), and all contained a 1.25-kb PCR fragment of integron that is part of the 43-kb Salmonella genomic island 1 (SGI1). The second group was resistant to SSu (28%), and the third was susceptible to all five drugs (13%). Fifty-nine isolates were serotyped to be serovar Typhimurium by the tube agglutination method using H antisera. The virulence plasmid was found in 54 (91.5%) of the 59 serovar Typhimurium isolates. A majority (94.1%) of the Salmonella serogroup B isolates with the ACSSuT resistance pattern harbored a virulence plasmid. Phage typing identified three major phage types: DT104, DT120, and U302. Analysis of the isolates by pulsed-field gel electrophoresis showed six genotypes. We found two genotypes in DT104 strains, two in DT120, and the other two in U302. The presence of a monophasic serovar (4,5,12:i:-) has added difficulty in the determination of the serovars of multidrug-resistant Salmonella serogroup B isolates. Nevertheless, the multiplex PCR devised in the present study appears to be efficient and useful in the rapid identification of ACSSuT-type serovar Typhimurium with SGI1, irrespective of their phage types.

Bacterial Proteins↗

Multiplex PCR-based method for identification of common clinical serotypes of Salmonella enterica subsp. enterica.

A multiplex PCR method has been developed to differentiate between the most common clinical serotypes of Salmonella enterica subsp. enterica encountered in Washington State and the United States in general. Six genetic loci from S. enterica serovar Typhimurium and four from S. enterica serovar Typhi were used to create an assay consisting of two five-plex PCRs. The assays gave reproducible results with 30 different serotypes that represent the most common clinical isolates of S. enterica subsp. enterica. Of these, 22 serotypes gave unique amplification patterns compared with each other and the other 8 serotypes were grouped into four pairs. These were further resolved by two additional PCRs. We compared the data from PCR serotyping with conventional serotyping and found that PCR serotyping was nearly as discriminatory as conventional serotyping was. The results from a blind test screening 111 clinical isolates revealed that 97% were correctly identified using the multiplex PCR assay. The assay can be easily performed on multiple samples with final results in less than 5 h and, in conjunction with pulsed-field gel electrophoresis, forms a very robust test method for the molecular subtyping of Salmonella enterica subsp. enterica.

Cost-Benefit Analysis↗

Rapid multiplex PCR assay for identification of USA300 community-associated methicillin-resistant Staphylococcus aureus isolates.

Recent reports have noted a discernible increase in the number of community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) infections in patients without traditional risk factors. In the United States, the most prominent CA-MRSA strain encodes Panton-Valentine leukocidin (PVL) cytotoxin genes, belongs to pulsed field gel electrophoresis type USA300 and multilocus sequence type 8, and carries staphylococcal cassette chromosome mec (SCCmec) type IV. At present, molecular characterization of MRSA strains, such as USA300, can be time-consuming and is often beyond the technical capability of many clinical laboratories, making routine identification difficult. We analyzed the chromosomal regions flanking the SCCmec element in 44 USA300 MRSA isolates and identified a signature "AT repeat" sequence within the conserved hypothetical gene SACOL0058 located 1.4 kb downstream of the 3' end of the J1-SCCmec chromosomal junction. Only USA300 isolates tested contained a sequence of > or =6 AT repeats in combination with PVL (e.g., related USA500 or Iberian strains had > or =6 AT repeats but were PVL negative). Using a locked nucleic acid primer specific for > or =6 AT repeats in combination with primers to detect PVL, we developed a multiplex PCR assay specific for the identification of USA300 strains. Multiplex results were 100% concordant with DNA sequencing, suggesting that the method has promise as a means of rapidly identifying USA300 isolates.

Bacterial Proteins↗

Identification of Vibrio isolates by a multiplex PCR assay and rpoB sequence determination.

Vibrio, a diverse genus of aquatic bacteria, currently includes 72 species, 12 of which occur in human clinical samples. Of these 12, three species--Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus-account for the majority of Vibrio infections in humans. Rapid and accurate identification of Vibrio species has been problematic because phenotypic characteristics are variable within species and biochemical identification requires 2 or more days to complete. To facilitate the identification of human-pathogenic species, we developed a multiplex PCR that uses species-specific primers to amplify gene regions in four species (V. cholerae, V. parahaemolyticus, V. vulnificus, and V. mimicus). The assay was tested on a sample of 309 Vibrio isolates representing 26 named species (including 12 human pathogens) that had been characterized by biochemical methods. A total of 190 isolates that had been identified as one of the four target species all yielded results consistent with the previous classification. The assay identified an additional four V. parahaemolyticus isolates among the other 119 isolates. Sequence analysis based on rpoB was used to validate the multiplex results for these four isolates, and all clustered with other V. parahaemolyticus sequences. The rpoB sequences for 12 of 15 previously unidentified isolates clustered with other Vibrio species in a phylogenetic analysis, and three isolates appeared to represent unnamed Vibrio species. The PCR assay provides a simple, rapid, and reliable tool for identification of the major Vibrio pathogens in clinical samples, and rpoB sequencing provides an additional identification tool for other species in the genus Vibrio.

Bacterial Typing Techniques↗

Genotyping by multiplex polymerase chain reaction for detection of endemic hepatitis B virus transmission.

A nested polymerase chain reaction (PCR) protocol was developed for rapid genotyping of hepatitis B virus (HBV). During the first PCR round, a universal HBV primer pair was used to amplify the entire pre-S region of the HBV genome. Within the pre-S region, many nucleotide exchanges are observed. These are partly correlated to the serological hepatitis B surface antigen subtypes. Five additional subtype-specific primers were selected from that region which, together with two universal non-group-specific primers, generated specific combinations of two to four DNA fragments of defined sizes. By this approach, 55 hepatitis B surface antigen-positive patients from a pediatric oncology unit in Germany were analyzed. Fifty-four patients who had been infected within 2 years had an identical pattern in the multiplex PCR, suggesting a common source of infection and person-to-person transmission within the unit. One child who was infected 5 years later had a different PCR pattern and, therefore, must have been infected from a different source. Furthermore, 109 serum samples taken from pregnant Cameroonian women and 25 serum samples from their babies taken 6 months after birth were analyzed. In one case, mother-to-infant transmission of the virus was demonstrated. Apart from its role in epidemiological studies on HBV, multiplex PCR may also be a useful tool for rapid genetic analysis in other fields if there is a moderate degree of sequence variation which enables the design of specific primers.

Base Sequence↗

Multiplex PCR for identification of methicillin-resistant staphylococci in the clinical laboratory.

A multiplex PCR assay for detection of the staphylococcal mecA gene (the structural gene for penicillin-binding protein 2a) was compared with agar dilution and disk diffusion susceptibility test methods for identifying methicillin resistance. The multiplex PCR assay combined two primer sets (mecA and 16S rRNA) in a single reaction. A total of 500 staphylococcal isolates (228 isolates of Staphylococcus aureus and 272 isolates of coagulase-negative staphylococci) from clinical specimens were studied. For S. aureus, 40 of 40 mecA-positive isolates and 4 of 188 mecA-negative isolates were oxacillin resistant (positive and negative predictive values of 100 and 98%, respectively). In 3 of 4 discordant isolates, resistance was due to hyperproduction of beta-lactamase. For coagulase-negative staphylococci, 148 of 159 mecA-positive isolates and 0 of 113 mecA-negative isolates were oxacillin resistant (positive and negative predictive values of 93 and 100%, respectively). Twenty-six isolates were categorized as indeterminate because of the absence of a detectable 16S rRNA product. Four of these 26 isolates contained mecA when retested. The assay is designed to be incorporated into the work flow of the clinical microbiology laboratory and allows for the identification of intrinsic resistance in a timely and reliable manner.

Base Sequence↗

Multiplex PCR assay and simple preparation method for stool specimens detect enterotoxigenic Escherichia coli DNA during course of infection.

Infection with enterotoxigenic Escherichia coli (ETEC) is a common cause of diarrhea among travelers and residents of developing countries. ETEC produces either a heat-stable toxin or a heat-labile toxin, or both, encoded by plasmid-borne ST and LT genes, respectively. Diagnosis of infection with this subclass of E. coli can be performed with oligonucleotide hybridization probes; however, the sensitivity and specificity of this method are insufficient. A nonradioactive multiplex PCR assay that provides a sensitive and specific method for detecting the presence of either or both toxin genes has been developed. A simple procedure that removed inhibitors of the PCR while efficiently releasing ETEC DNA from stool specimens for subsequent amplification was used. The results for samples from a human volunteer study of ETEC infection indicated that this method of sample preparation results in greater clinical sensitivity than conventional total nucleic acid extraction and ethanol precipitation. Detection of ETEC by a multiplex PCR assay in stool specimens directly processed with a glass matrix and chaotropic solution had greater sensitivity than culture.

Adult↗