At least 1,081 records · Page 60Linked to original sources

Flexion after total knee replacement. A comparison between the Medial Pivot knee and a posterior stabilised implant.

A comparison was made between 261 knees replaced with the Medial Pivot arthroplasty and 288 replaced with the 913 posterior stabilised arthroplasty (PS knee). There was no significant difference in the flexion obtained at 12 months after surgery (111 degrees and 109 degrees , respectively). When the knees were grouped into preoperative flexion ranges, there was no significant difference between the two implants. Those knees with preoperative flexion up to 90 degrees gained most (mean 22.6 degrees and 19 degrees for the PS knee and Medial Pivot, respectively). Knees with a preoperative flexion of 125 degrees or greater lost flexion. Regression analysis of individual knees revealed a small (average 2.9 degrees ), but significant greater loss of flexion at 12 months after surgery in the Medial Pivot group, with increasing preoperative flexion (beta coefficient = 2.923, P = 0.007). Some knees in both groups which had less than average preoperative flexion lost rather than gained flexion. We attributed this to patient factors such as pain, swelling and poor compliance with rehabilitation. Although the Medial Pivot knee may have advantages in terms of contact area and kinematics we found no advantage in terms of postoperative flexion over our posterior stabilised knee.

Aged↗

Unicompartmental knee arthroplasty for osteoarthritis of the knee: remaining postoperative flexion contracture affecting overall results.

The success rate of unicompartmental knee arthroplasty has been variable, and controversy still surrounds its use. Achieving good functional results from this surgery may require understanding surgical principles, precise operative techniques, and careful patient selection. This paper evaluates clinical results and factors influencing postoperative knee function after unicompartmental knee arthroplasty. The follow-up assessment of 109 knees that underwent unicompartmental knee arthroplasty showed that 90 of 109 knees were classified as excellent or good (82.6%) using the Hospital for Special Surgery knee scoring system. In the excellent group (54 knees), 52% of the postoperative, standing femorotibial angles converged on a range of 170 degrees to 175 degrees with a mean of 174 degrees +/- 4 degrees. The knees with residual flexion contracture after surgery showed poorer clinical results. Therefore, complete elimination of the flexion contracture during surgery is considered mandatory.

Arthroplasty, Replacement, Knee↗

Instability after total knee arthroplasty with the Miller-Gallante II total knee: 5- to 7-year follow-up.

A consecutive series of 64 posterior cruciate-retaining hybrid total knee arthroplasties in 50 patients were reviewed with an average 57-month follow-up. Seven patients died or were lost to follow-up. One patient was revised for infection in the early postoperative period, and there were no cases of aseptic loosening. Four revisions were performed for recurrent effusions and progressive instability at a mean of 55 months postoperatively. There were statistically significant correlations between manual stability testing (anteroposterior, mediolateral, and pivot shift) and Hospital for Special Surgery and Knee Society scores. At intermediate follow-up, the Miller-Gallante II total knee arthroplasty is functioning well except in a subgroup of patients with progressive instability resulting from a combination of patient and implant factors.

Arthroplasty, Replacement, Knee↗

The effect of a tibial baseplate undersurface peripheral lip on cement penetration in total knee arthroplasty.

Many total knee arthroplasty (TKA) tibial baseplates have a peripheral lip or cement pocket theoretically to increase cement penetration by decreasing edge escape of the cement squeeze film on baseplate impaction. We reviewed 177 consecutive TKAs (89 nonlipped and 87 lipped baseplates) performed by a single surgeon, using the same third-generation tibial cementation techniques. Cement penetration patterns of the lateral 12 mm of proximal tibia were examined by a semiautomatic computerized digital image analysis technique. Penetration in the lipped baseplate was double that of the nonlipped baseplate at the component's lateral edge (P<.05) and continued to be statistically significantly greater to 4 mm from edge. From 5 to 7 mm, the difference was no longer statistically significant, and from 8 to 12 mm, the penetration was equal.

Aged↗

[Foreign body reaction in carbon fiber prosthesis implantation in the knee joint--case report and review of the literature].

We present the clinical radiological and pathological data of a patient who underwent carbon fiber implantation of the right knee. Within half a year a total knee replacement had to be performed due to persistent pain. Apart from the intraoperative, macroscopically visible, massive sclerosis around the drill holes and an obvious synovial reaction, we histopathologically found a severe granulomatous foreign body reaction around the carbon fibers. Experimental data point toward a negative influence of a foreign body reaction on attempted cartilage repair. The implantation of carbon fibers can be recommended neither for biomechanical nor for pathophysiological reasons. Before this treatment can be recommended, prospective randomized trials are mandatory.

Aged↗

[Unicondylar knee arthroplasty--indications and outcome].

Continuous development of new materials, improved operative technique and exact patient selection lead to increasing survival rates of unicondylar sleigh arthroplasties during the last decade as it's demonstrated in this review on the literature. During the 80s the average survival rate after 5 years was 85 %, after 9 years 60 %. In the 90s significantly better results were noted with 5 and 10 years survival in more than 95 % of the cases. Thus, like current studies prove, unicondylar sleigh arthroplasties have reached the standard of complete surface replacement. Additionally minimal loss of bone stock, sparing of the crucial ligaments and of the femoropatellar joint as well as short operation time and low morbidity are advantages of these arthroplasties.

Equipment Failure Analysis↗

Dislocation of the bearing of the Oxford lateral unicompartmental arthroplasty. A radiological assessment.

When the Oxford unicompartmental meniscal bearing arthroplasty is used in the lateral compartment of the knee, 10% of the bearings dislocate. A radiological review was carried out to establish if dislocation was related to surgical technique. The postoperative radiographs of 46 lateral unicompartmental arthroplasties were analysed. Five variables which related to the position and alignment of the components were measured. Dislocations occurred in six knees. Only one of the five variables, the proximal tibial varus angle, had a statistically significant relationship to dislocation. This variable quantifies the height of the lateral joint line. The mean proximal tibial varus angle for knees the bearings of which had dislocated was 9 degrees and for those which had not it was 5 degrees. In both groups it was greater than would be expected in the normal knee (3 degrees). Our study suggests that a high proximal tibial varus angle is associated with dislocation. The surgical technique should be modified to account for this, with care being taken to avoid damage to or overdistraction of the lateral soft tissues.

Aged↗

Intraoperative measurements of male and female distal femurs during primary total knee arthroplasty.

The anteroposterior (AP) and medial-lateral (ML) dimensions of 200 consecutive osteoarthritic knees (100 males and 100 females) undergoing unilateral primary total knee arthroplasty were compared. For all patients, the mean AP dimension was 57.3 mm (range: 49-66 mm) and the dimension was 10.5% taller in height in men than women. The mean ML dimension was 71.6 mm (range: 56-85 mm), and the dimension was 13.7% wider in men than women. The mean AP/ML ratio was 0.8 for all patients, 0.82 (range: 0.73-0.93) for females and 0.79 (range: 0.70-0.89) for males (P<.001). The data suggest that for any given AP femoral dimension, women tend to have a narrower ML dimension than men, independent of AP height, and an AP/ML ratio of 0.80 most closely approximates a standard-sized distal femur across gender. This report documents important gender differences that may serve as a reference for femoral implant designers and knee surgeons.

Adult↗

Extensor mechanism complications following total knee arthroplasty.

Patellofemoral complications are avoided by careful patient selection, proper implant design, and correct surgical technique. The patient with an extensor mechanism complication should be carefully evaluated for femoral and tibial component positioning, especially rotational alignment. Management of the extensor mechanism complication should be directed at its cause and may necessitate revision of the entire arthroplasty. Isolated revision of a patellar implant should only be performed once satisfactory alignment of the femoral and tibial components has been confirmed.

Arthroplasty, Replacement, Knee↗

Screw home motion after total knee replacement.

The objective of this study was to evaluate the effect of muscle force and the posterior cruciate ligament on screw home motion in patients with total knee replacement in a posterior cruciate ligament retaining prosthesis (10 knees) and a posterior cruciate ligament substituting prosthesis (10 knees). Screw home motion was examined with only active extension and with two types of externally loaded active extension (2 kg and body weight). Screw home motion was measured with a 6 degrees of freedom electrogoniometer (instrumented spatial linkage). Retaining the posterior cruciate ligament maintained screw home motion, with and without external load to muscles, whereas substituting the posterior cruciate ligament maintained screw home motion only under the full external load of body weight. This was not seen with a 2-kg external load. As for the normal knee, it appears that screw home motion of a prosthetic knee is influenced, not only by the presence of ligamentous structures, but also by the activity of the muscles. The activity of the muscles may have a much greater effect on screw home motion with currently used prosthetic designs than does the presence of ligamentous structures.

Aged↗

[Suggestion for technical facilitation of Blauth's knee endoprosthesis implantation].

Unsatisfactory seats of the prosthesis in femur and tibia within our clinical and roentgenological materials have been analysed. Upon this basis, the authors suggest some technical improvements with implantation of Blauth's prosthesis of knee joint as follows: 1) Preoperative exact plan of bone resections according to a.p. and lateral X-ray films of knee joint with the aid of cut-out X-ray films of the prosthesis and/or of our test-apparatus of femoral shaft. 2) Ascertain the horizontal line of tibia with the help of a vertical line of tibial shaft drawn preoperatively. 3) It should be emphasized, that finger groping during operation is indispensable.

Humans↗

The role of pre-operative templating in primary total knee replacement.

Templating of preoperative X-rays is routinely performed before a total knee replacement. We performed this retrospective study on preoperative templating in primary total knee replacement to assess its accuracy and reproducibility. Preoperative radiographs of 47 patients were templated twice by two observers separately after a gap of 3 months. The size of actual implant used was compared to the size predicted by templating. Data were analysed to assess inter and intra-observer variation. Templating was accurate for both tibial and femoral components in only 53.2% of observations. This study also revealed that templating is a highly-subjective and observer-dependent technique. Inter-observer and intra-observer mismatch was present in 46.8% and 43.6% of readings respectively. We conclude from this study that preoperative templating is neither accurate nor reproducible.