Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fluorescence Microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Visualizing single molecules inside living cells using total internal reflection fluorescence microscopy.

Over the past 10 years, advances in laser and detector technologies have enabled single fluorophores to be visualized in aqueous solution. Here, we describe methods based on total internal reflection fluorescence microscopy (TIRFM) that we have developed to study the behavior of individual protein molecules within living mammalian cells. We have used cultured myoblasts that were transiently transfected with DNA plasmids encoding a target protein fused to green fluorescent protein (GFP). Expression levels were quantified from confocal images of control dilutions of GFP and cells with 1-100 nM GFP were then examined using TIRFM. An evanescent field was produced by a totally internally reflected, argon ion laser beam that illuminated a shallow region (50-100 nm deep) at the glass-water interface. Individual GFP-tagged proteins that entered the evanescent field appeared as individual, diffraction-limited spots of light, which were clearly resolved from background fluorescence. Molecules that bound to the basal cell membrane remained fixed in position for many seconds, whereas those diffusing freely in the cytoplasm disappeared within a few milliseconds. We developed automated detection and tracking methods to recognize and characterize the behavior of single molecules in recorded video sequences. This enabled us to measure the kinetics of photobleaching and lateral diffusion of membrane-bound molecules.

Animals↗

Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy.

The decay of evanescent field intensity beyond a dielectric interface depends upon beam incident angle, enabling the 3-d distribution of fluorophores to be deduced from total internal reflection fluorescence microscopy (TIRFM) images obtained at multiple incident angles. Instrumentation was constructed for computer-automated multiple angle-TIRFM (MA-TIRFM) using a right angle F2 glass prism (n(r) 1.632) to create the dielectric interface. A laser beam (488 nm) was attenuated by an acoustooptic modulator and directed onto a specified spot on the prism surface. Beam incident angle was set using three microstepper motors controlling two rotatable mirrors and a rotatable optical flat. TIRFM images were acquired by a cooled CCD camera in approximately 0.5 degree steps for >15 incident angles starting from the critical angle. For cell studies, cells were grown directly on the glass prisms (without refractive index-matching fluid) and positioned in the optical path. Images of the samples were acquired at multiple angles, and corrected for angle-dependent evanescent field intensity using "reference" images acquired with a fluorophore solution replacing the sample. A theory was developed to compute fluorophore z-distribution by inverse Laplace transform of angle-resolved intensity functions. The theory included analysis of multiple layers of different refractive index for cell studies, and the anisotropic emission from fluorophores near a dielectric interface. Instrument performance was validated by mapping the thickness of a film of dihexyloxacarbocyanine in DMSO/water (n(r) 1.463) between the F2 glass prism and a plano-convex silica lens (458 mm radius, n(r) 1.463); the MA-TIRFM map accurately reproduced the lens spherical surface. MA-TIRFM was used to compare with nanometer z-resolution the geometry of cell-substrate contact for BCECF-labeled 3T3 fibroblasts versus MDCK epithelial cells. These studies establish MA-TIRFM for measurement of submicroscopic distances between fluorescent probes and cell membranes.

3T3 Cells↗

Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission.

The diffraction barrier responsible for a finite focal spot size and limited resolution in far-field fluorescence microscopy has been fundamentally broken. This is accomplished by quenching excited organic molecules at the rim of the focal spot through stimulated emission. Along the optic axis, the spot size was reduced by up to 6 times beyond the diffraction barrier. The simultaneous 2-fold improvement in the radial direction rendered a nearly spherical fluorescence spot with a diameter of 90-110 nm. The spot volume of down to 0.67 attoliters is 18 times smaller than that of confocal microscopy, thus making our results also relevant to three-dimensional photochemistry and single molecule spectroscopy. Images of live cells reveal greater details.

Escherichia coli↗

Imaging of cell/substrate contacts on polymers by total internal reflection fluorescence microscopy.

A simplified model of total internal reflection fluorescence (TIRF) emission of fluorescently labeled cell membranes [Reichert, W. M.; Truskey, G. A. J. Cell Sci. 1990, 96, 219-230] was used to determine the topography of the cell membrane in apposition to a polymer-coated surface. The homopolymer substrates were spun cast films of hydrophilic poly(hydroxyethyl methacrylate) (polyHEMA) or hydrophobic poly(ethyl methacrylate) (polyEMA). Bovine aortic endothelial cells (BAEC) on preadsorbed fibronectin polymer substrates were either plated for 24 h, fixed, labeled, and examined by TIRF microscopy (TIRFM) and phase-contrast microscopy or plated for 2 h and tested for their adhesion strength in a parallel-plate flow chamber. BAEC attached to polyHEMA showed no evidence of focal contact formation. However, BAEC attached to polyEMA were well spread and showed an array of focal contacts. TIRFM data were transformed to construct a detailed topographical map of relative cell/substrate separation distances. Virtually all of the BAEC plated to polyHEMA were sheared from the surface when subjected to a 50 dyn/cm2 burst of laminar flow, whereas only 10% of the BAEC were sheared from the polyEMA surface. These data suggest that the polyHEMA and polyEMA surface properties (e.g., hydrophobicity) correlate with the presence of BAEC focal contacts and the BAEC attachment strength.

Animals↗

Equilibrium, kinetics, diffusion and self-association of proteins at membrane surfaces: measurement by total internal reflection fluorescence microscopy.

The equilibrium, kinetics, diffusion and self-association of proteins at membrane/solution interfaces may deviate substantially from these processes in bulk solution. A set of methods for examining these phenomena combines substrate-supported planar model membranes and the use of evanescent illumination with laser-based, quantitative fluorescence microscopy. Measurement of the steady-state, surface-associated fluorescence can be used to examine the thermodynamic properties of proteins at membranes. When combined with fluorescence photobleaching recovery, this technique provides information about membrane-binding kinetics; and when combined with fluorescence pattern photobleaching recovery, measurement of the translational diffusion coefficients of proteins weakly bound to membranes is possible. The use of polarized evanescent illumination can provide information about the orientation distributions of adsorbed fluorophores. Fluorescence correlation spectroscopy provides information about the self-association (e.g. dimerization) of membrane-associated proteins.

Animals↗

Intracellular compartmentalization of fura-2 dye demonstrated by laser-excitation fluorescence microscopy: a problem in measuring cytosolic free calcium concentration using fura-2 fluorescence in vascular smooth muscle cells.

Recently, we have developed a novel laser-excitation fluorescence microscope system to study intracellular calcium (Ca2+) in individual cultured vascular smooth muscle (VSM) cells using fluorescent indicators for (Ca2+). In the course of our study, it was shown that the subcellular fluorescence distribution of fura-2 was not homogeneous in VSM cells incubated with the acetoxy-methyl ester form of fura-2, fura-2/AM. The fluorescence appeared spotty or filamentous and resembled in shapes the intracellular organelles, suggesting that there was fura-2 dye compartmentalization in the organelles. To clarify the nature of the subcellular fluorescence, the soluble fraction of cells loaded with the dye was analyzed through high performance liquid chromatography (HPLC). We also examined the excitation spectra of fluorescence in the soluble fraction, which was compared with that in the cell suspension. Using HPLC, it has been shown that no other than fura-2 was found in the soluble fraction, whereas analyses of excitation spectra have indicated that the membrane fraction contained fura-2/AM or its lipophilic metabolite. On the other hand, indo-1 dye fluorescence showed a diffuse intracellular distribution, but the nuclear region had higher or sometimes lower fluorescence levels than the cytoplasm. The present results suggest that it may be necessary to assess subcellular fura-2 compartmentalization and possible interference by fura-2 AM or its lipophilic metabolite for the accurate measurement of intracellular Ca2+ concentration in VSM cells. It is also suggested that indo-1 may be more suitable for estimating Ca2+ concentration than fura-2 in individual VSM cells.

Animals↗

Fluorescence microscopy of calcium and synaptic vesicle dynamics during synapse formation in tissue culture.

The signal transduction process involved in the development of the nerve terminal is an intriguing question in developmental neurobiology. During the formation of the neuromuscular junction, presynaptic development is induced by growth cone's contact with the target muscle cell. Fluorescence microscopy with specific markers has made it possible to follow signalling events during this process. By using fluorescent calcium indicators, such as fura-2 and fluo-3, we found that a rise in intracellular calcium is elicited in the growth cone upon its contact with a target, and this calcium signal can also be elicited by local application of basic fibroblast growth factor. To monitor the clustering of synaptic vesicles in response to target contact, the fluorescent vesicular probe FMl-43 was used. With this probe, we observed that packets of synaptic vesicle are already present along the length of naïve neurite, which has not encountered its synaptic target. The activity-dependent loading of FMl-43 indicates that these packets can undergo exocytosis and endocytosis upon depolarization. Time-lapse recording showed that these packets are quite mobile. Upon target contact, synaptic vesicles become clustered and immobilized at the contact site. The methodology and instrumentation used in these studies are described in this article.

Animals↗

The effects of haloalkene cysteine conjugates on cytosolic free calcium levels in LLC-PK(1) cells--studies utilising digital imaging fluorescence microscopy.

The aim of this study was to examine the effect of haloalkene S-cysteine conjugates on cytosolic free Ca(2+) levels in renal epithelial cells using digital imaging fluorescence microscopy (DIFM). S-(1,2,3,4,4-pentachloro-1,3,-butadienyl)-L-cysteine (PCBC) and S-(1,2-dichlorovinyl)-L-cysteine (DCVC) were both cytotoxic to LLC-PK(1) cells in culture. Prior treatment of the cells with aminooxyacetic acid (AOAA), an inhibitor of the enzyme cysteine conjugate beta-lyase, afforded complete protection against the toxicity at concentrations of PCBC up to 100 microM and DCVC up to 500 microM. The cytotoxicity produced by PCBC (100 microM) was time dependent with no loss of lactate dehydrogenase (LDH) into the medium being observed until 4 h after exposure, while removal of calcium from the medium prevented the toxicity. Addition of PCBC (100 microM) to LLC-PK(1) cells produced a small progressive increase in intracellular calcium ([Ca(2+)](i)) from 72+/-6 to 126+/-11 nM following 10 min of exposure. At this time there was a marked cellular heterogeneity in the calcium response with some cells showing marked increases in [Ca(2+)](i), while others cycled between low and high values and some just maintained basal levels. Exposure to PCBC (100 microM) for 1 h produced a more marked increase in [Ca(2+)](I), 469+/-46 nM, with all cells responding. The elevation in [Ca(2+)](i) was concentration-related with increases seen at concentrations of 5 microM PCBC and above. The increase in [Ca(2+)](i) produced by PCBC (100 microM) was prevented by treatment with AOAA, and markedly reduced by a nominally calcium free medium or the addition of the calcium chelator EGTA. DCVC (500 microM) also markedly elevated [Ca(2+)](i) following exposure for 1 h, this was also prevented by AOAA and a nominal calcium free medium. These findings indicate that elevation in [Ca(2+)](i) produced by PCBC in renal epithelial cells, is an early event in the cascade of signalling changes leading to renal cell death. The major source of calcium appears to be from increased influx although a small component is released from intracellular stores which my trigger a stress protein response.

Aminooxyacetic Acid↗

Direct visualization by confocal fluorescent microscopy of the permeation of myristoylated peptides through the cell membrane.

To study the permeability through the cellular membrane of synthetic peptides containing an hydrophobic moiety, we used a 13-mer myristoylated peptide labeled with a N-terminal fluorescent probe. After 2 h of incubation, the subcellular distribution was analyzed in intact chromaffin cells by confocal fluorescent microscopy. Our results demonstrate that myristoylated peptides diffuse into intact cells, showing an heterogeneous distribution, but they do not reach the cellular nucleous, at least during the time range used.

Acylation↗

Measurement of marine picoplankton cell size by using a cooled, charge-coupled device camera with image-analyzed fluorescence microscopy.

Accurate measurement of the biomass and size distribution of picoplankton cells (0.2 to 2.0 microns) is paramount in characterizing their contribution to the oceanic food web and global biogeochemical cycling. Image-analyzed fluorescence microscopy, usually based on video camera technology, allows detailed measurements of individual cells to be taken. The application of an imaging system employing a cooled, slow-scan charge-coupled device (CCD) camera to automated counting and sizing of individual picoplankton cells from natural marine samples is described. A slow-scan CCD-based camera was compared to a video camera and was superior for detecting and sizing very small, dim particles such as fluorochrome-stained bacteria. Several edge detection methods for accurately measuring picoplankton cells were evaluated. Standard fluorescent microspheres and a Sargasso Sea surface water picoplankton population were used in the evaluation. Global thresholding was inappropriate for these samples. Methods used previously in image analysis of nanoplankton cells (2 to 20 microns) also did not work well with the smaller picoplankton cells. A method combining an edge detector and an adaptive edge strength operator worked best for rapidly generating accurate cell sizes. A complete sample analysis of more than 1,000 cells averages about 50 min and yields size, shape, and fluorescence data for each cell. With this system, the entire size range of picoplankton can be counted and measured.

Algorithms↗

Application of total internal reflection fluorescence microscopy to study cell adhesion to biomaterials.

Cell adhesion and function depend upon the formation of adhesive contacts between the cell and substrate. Determination of the cell substrate contact area is necessary in order to understand how biomaterial properties influence cell adhesion. In this review we describe the development and application of total internal reflection fluorescence microscopy (TIRFM) to quantify the separation distance of cells from a biomaterial surface. An approximate theory is presented for the straightforward calculation of separation distances when a fluor is placed in the cell membrane. The validity of this approach is discussed. TIRFM is compared to interference reflection microscopy and related techniques that measure cell/substrate separation distances. This approach is then applied to a number of important problems in cell substrate interactions, including changes in contact area and adhesion strength on biomaterial surfaces, analysis of bond strength, and real-time measurement of cell/substrate separation distances following exposure to flow.

Animals↗