Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ENDOSCOPY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Jejunal leiomyosarcoma, a rare cause of obscure gastrointestinal bleeding diagnosed by wireless capsule endoscopy.

Obscure gastrointestinal bleeding is a relatively frequent disorder and may account for as many as 5% of all cases of gastrointestinal bleeding. The etiology of these hemorrhages may be attributed to lesions in the small intestine, which may not show up in radiologic studies, located in areas inaccessible to conventional endoscopy. The case of a 50-year-old patient admitted to the hospital on two occasions for gastrointestinal bleeding requiring blood transfusions is reported. On the first occasion, the bleeding was thought to be caused by a duodenal ulcer because no other lesions prone to bleeding were found. At the next admission for recurrent bleeding, the ulcer was found to have healed and thus was ruled out as the cause. Wireless capsule endoscopy detected an ulcerated tumor invading the submucosa of the jejunum. The pathologic diagnosis was low-grade leiomyosarcoma. Wireless capsule endoscopy has proved to be far superior to other radiologic and endoscopic techniques for the diagnosis of obscure gastrointestinal bleeding and pathologies of the small intestine in general.

Blood Transfusion↗

Possibilities and limitations of current stereo-endoscopy.

BACKGROUND: Stereo-endoscopy has become a commonly used technology. In many comparative studies striking advantages of stereo-endoscopy over two-dimensional presentation could not be proven. To show the potential and fields for further improvement of this technology is the aim of this article. METHOD: The physiological basis of three-dimensional vision limitations of current stereo-endoscopes is discussed and fields for further research are indicated. New developments in spatial picture acquisition and spatial picture presentation are discussed. RESULTS: Current limitations of stereo-endoscopy that prevent a better ranking in comparative studies with two-dimensional presentation are mainly based on insufficient picture acquisition. CONCLUSION: Devices for three-dimensional picture presentation are at a more advanced developmental stage than devices for three-dimensional picture acquisition. Further research should emphasize the development of new devices for three-dimensional picture acquisition.

Depth Perception↗

Learning curves and impact of psychomotor training on performance in simulated colonoscopy: a randomized trial using a virtual reality endoscopy trainer.

BACKGROUND: The aim of this study was to analyze the learning curve for the GI Mentor II endoscope trainer and to determine whether psychomotor training can contribute to an improvement in the performance of virtual colonoscopy. METHODS: To analyze the learning curve, 28 subjects were divided into three groups on the basis of their experience with gastrointestinal (GI) endoscopy: experienced surgeons (group 1, performed > 200 endoscopic procedures, (n = 8)) residents (group 2, performed < 50 endoscopic procedures, (n = 10)); and medical students (group 3, never performed GI endoscopy, (n = 10)). The participants were tested on the GI Mentor II virtual reality simulator 10 consecutive times. Assessment of the learning curve was based on the following three parameters: time used, number of punctured balloons, and number of wall collisions. In the second part of the study, 20 subjects who had never performed GI endoscopy were included. After performing a virtual colonoscopy, they were randomized to a group that received psychomotor training and a control group. Finally, all subjects performed a virtual colonoscopy. Assessment of endoscopic skills during the colonoscopy was based on nine parameters dealing with psychomotor skills. RESULTS: The learning curve for time expended reached a plateau after the second repetition for group 1 (Friedman's test, p < 0.05), after the fifth repetition for group 2 (p < 0.05), and after the seventh repetition for group 3 (p < 0.05). Experienced surgeons did not improve their scores for regarding number of balloons punctured or number of wall collisions (p > 0.05), indicating the absence of a learning curve for these parameters. Group 2 improved their scores up to the fourth and fifth repetitions, respectively (p < 0.05), and group 3 up to the fifth and seventh repetitions, respectively (p < 0.05). Experienced surgeons achieved the best performance, followed by group 2 and then group 3. The surgeons who had received psychomotor training performed the second virtual colonoscopy significantly faster than the control group (Mann-Whitney test, p < 0.001) and made significantly greater improvement in all other parameters as well. CONCLUSIONS: There were different learning curves for surgeons depending on their endoscopic background. The familiarization rate on the simulator was proportional to the endoscopic experience of the surgeons. Psychomotor training had a significant effect on the performance of a simulated colonoscopy.

Clinical Competence↗

Features of early gastric cancer and gastric adenoma by enhanced-magnification endoscopy.

BACKGROUND: Changes to the mucosal surface of early gastric carcinomas and gastric adenomas as viewed by enhanced-magnification endoscopy with acetic acid have not been investigated thoroughly. Using this technology, we investigated the appearance of the gastric surface patterns of neoplastic and surrounding nonneoplastic mucosa. METHODS: Forty-seven consecutive patients with early gastric carcinomas or gastric adenomas underwent enhanced-magnification endoscopy following 1.5% acetic acid instillation. All biopsy specimens were taken from the area at which the enhanced-magnified endoscopic image was obtained. RESULTS: Surface patterns of gastric tumors and the surrounding mucosa were classified into five types: type I, small round pits of uniform size and shape; type II, slit-like pits; type III, gyrus and villous patterns; type IV, irregular arrangements and sizes of pattern types I, II and III; type V, destructive patterns of types I, II and III. The predominant pattern of the surrounding mucosa was type III, and most type III mucosa had characteristics of intestinal metaplasia. Although all elevated adenomas showed type II or type III surface patterns, both depressed adenomas showed type IV. Elevated carcinomas showed type III (42.9%) or type IV (57.1%) surface patterns, while depressed carcinomas showed type IV (70%) or type V (30%). Although differentiated tubular adenocarcinomas showed type III (10.3%), type IV (86.2%), or type V (3.5%) surface patterns, all of the signet-ring cell carcinomas and poorly differentiated tubular adenocarcinomas showed type V. CONCLUSIONS: Enhanced-magnification endoscopy may be useful for identifying gastric tumors and determining the extent of horizontal spread, especially in tumors of the depressed type.

Adenoma↗

[Evaluation of B-scan ultrasound, 3-D ultrasound, roentgen diagnosis and sinus endoscopy in follow-up assessment of the maxillary sinus after sinus floor elevation].

PROBLEM: The aim of this study was to determine which technique--B-scan sonography, 3D sonography, X-ray, or endoscopy--is the most effective for diagnosis in changes of the maxillary sinus after sinus lift and simultaneous augmentation. MATERIAL AND METHODS: In 33 patients the maxillary sinus was examined before sinus lift, 1 week and 6 months postoperatively with a 7.5-MHz linear scanner and 3D sonography. At the same time, the sonographic results were compared with the X-ray as well as the endoscopic results. Endoscopy of the maxillary sinus was only applied during the sinus lift operation and the abutment operation after 6 months. RESULTS: A total of 56 operations of sinus lift and simultaneous augmentation with autogenous bone were carried out. Preoperatively, there where no pathological findings detectable in the maxillary sinus. One week postoperatively, the X-rays as well as the sonographic images revealed thickening of the mucosa in 40 maxillary sinuses. After the healing period of 6 months, polyposa was still detected in three cases sonographically, in the radiographic follow-up as well as endoscopically. The sonographic 3D imaging of the maxillary sinus improved the spatial visualization of postoperative changes in the maxillary sinus and the reliability of the diagnosis. CONCLUSION: Due to the lack of radiation, the cost effectiveness, and its reproducibility, sonography is suitable as a primary screening technique in recall. In cases of normal sonographic findings but clinical symptoms, CT, MRT, and endoscopy should be performed to exclude pathological processes of the posterior maxillary sinus.

Alveolar Ridge Augmentation↗

Capsule endoscopy examination--preliminary review by a nurse.

Capsule endoscopy (CE) has been recommended as the method of choice for diagnostic endoscopy of the small bowel. An experienced nurse, after proper training, may contribute to the endoscopy procedures as previously described for sigmoidoscopy. The aim of this study was to evaluate the ability of an experienced gastroenterology nurse to prepare CE records for physician interpretation, by detecting abnormal thumbnails. A prospective, observational design was used. Fifty CE videos were pre-read by a specially trained gastroenterology nurse who thumbnailed the abnormalities detected for interpretation by the gastroenterologist. The nurse's description of the lesions and the calculated gastric and bowel transit times were compared to the interpretation of the videos made directly by the gastroenterologist (gold standard). The primary end point of the study was the quality of the nurse's pathology findings; the secondary end point was the cost effectiveness of this practice. There was complete agreement between the nurse and gastroenterologist for all 12 cases interpreted as normal by the gastroenterologist. In the remaining 38 cases, the nurse created 130 thumbnail selections and the physician, 99. Complete interobserver agreement was achieved for 93 of the 96 lesions categorized as "significant" by the physician (96.9%). After all relevant variables were taken into account, this approach saved dollar 324 per CE examination. The use of nurse practitioner to pre-read CE videos and prepare thumbnail selections for further assessment by the gastroenterologist appears to be safe, reliable, and cost effective.

Clinical Competence↗

Randomized active and placebo-controlled endoscopy study of a novel protected formulation of oral alendronate.

Although generally well tolerated, oral aminobisphosphonates have been associated with sporadic cases of severe esophageal injury attributed to pill contact. A novel protected formulation of oral alendronate uses an inert cylindrical shell to prevent mucosal contact with intact tablets. An active and placebo-controlled endoscopy study was undertaken to assess mucosal injury associated with this protected formulation. Healthy volunteers with normal baseline endoscopy were randomly assigned to receive protected alendronate 70 mg/day, standard alendronate 70 mg/day, or placebo for 14 days. Endoscopy was repeated on days 8 and 15. Of 78 subjects, 30 received protected alendronate, 28 received standard alendronate, and 20 received placebo. Mean gastric injury scores did not differ significantly among treatment groups. However, subjects on standard alendronate were more likely than those on protected alendronate to develop severe gastric injury, defined as Lanza score 3 or 4 (67.9% versus 33.3%, P=.009), and more likely to develop a gastric ulcer (21.4% versus 3.3%, P=.015). No differences in symptoms or adverse events were observed. In conclusion, a novel protected formulation of oral alendronate is less likely than standard alendronate to induce severe mucosal injury to the upper gastrointestinal tract.

Administration, Oral↗

Unsedated transnasal endoscopy: a safe and less costly alternative.

Upper endoscopy is an integral component in the management of upper gastrointestinal disorders, but it is underutilized because of its high cost and potential complications. Unsedated transnasal endoscopy (T-EGD) is a relatively new technique using an ultrathin endoscope. Because it is better tolerated than standard upper endoscopy, it is performed with the patient unsedated, thus avoiding the associated costs and complications of conscious sedation. In this review, the technique of T-EGD and its current experience are discussed. In addition, potential future applications, special considerations, and potential pitfalls are reviewed.

Procedural Sedation↗

Capsule endoscopy.

Video capsule endoscopy is a major innovation that provides high-resolution imaging of the entire small intestine in its entirety. In the 4 years since its introduction, capsule endoscopy has demonstrated its viability as a first-line investigation in patients with obscure gastrointestinal bleeding after a negative esophagogastroduodenoscopy and colonoscopy, and it has a positive impact on the outcome. Video capsule endoscopy is also useful in the evaluation of inflammatory and neoplastic disorders of the small bowel. Its role in children and in the evaluation of esophageal disorders is currently being explored and defined.

Capsules↗

Interventional upper endoscopy: the pediatric perspective.

Pediatric endoscopy has evolved from a purely observational modality into one with the potential for many therapeutic applications. Common therapeutic uses of endoscopy in children now include treatment of variceal bleeds and foreign body retrieval and newer procedures such as endoluminal gastroplication and endoscopic pyloromyotomy. Continuing research in pediatric endoscopy will allow pediatric gastroenterologists to perfect existing interventional endoscopic techniques and to learn to perform new ones.

Child↗

AIDS: practising safe endoscopy.

The emergence of HIV has provoked a widespread reappraisal of infection control practices in endoscopy units. Infection control practices should be applied to all patients alike without recourse to selection or screening. Although there has only been one reported instance of viral transmission at endoscopy, HIV could in theory be transmitted by a contaminated endoscope. Experience suggests that this is more likely to occur from damaged endoscopes, if an unsuitable disinfectant is used or endoscopes are not precleaned. In-use studies have shown that HIV contaminates endoscopes used on patients with AIDS, but in amounts too small to cause infection in tissue cultures. Cleaning in neutral detergent is extremely effective in removing contaminating micro-organisms, including HIV, from endoscopes. Aldehydes are the disinfectants of choice, but any disinfectant may fail if organic material is not removed by cleaning. After thorough cleaning, short disinfection times (e.g. four minutes) ensure inactivation of all relevant micro-organisms except Cryptosporidium and mycobacteria, although in practice even these organisms are likely to be reduced to non-pathogenic levels. Accidental needlestick injuries are the greatest hazard in the endoscopy suite; needles should not be resheathed and biopsy forceps must be handled with great care. The wearing of gloves should become second nature.

Acquired Immunodeficiency Syndrome↗

Monitoring and safety in endoscopy.

Over 50% of the complications and 60% of the deaths associated with upper GI endoscopy are cardiopulmonary in type. Oxygen desaturation and cardiac arrhythmias at the time of endoscopy are common. Ways of trying to prevent hypoxia occurring are discussed. The most effective of these is the use of supplemental oxygen. Pulse oximeters are being used increasingly frequently by endoscopists. The way in which oximeters work is described in some depth, as are some of the potential errors that may result from their use. The author believes that, as in anaesthetic practice, pulse oximeters will be used ever more frequently by endoscopists and finally become standard equipment in all endoscopy units. The case for using continuous ECG monitoring and blood pressure measurement is briefly discussed. The ASGE have recently published their recommendations on monitoring patients undergoing GI endoscopic procedures. The BSG's own working party on safety and monitoring is in the process of finalizing its recommendations, and the final part of the chapter discusses the views of this working party and gives some insight into what its final recommendations are likely to be.

Arrhythmias, Cardiac↗

The appreciation of colour in endoscopy.

The perception of colour at endoscopy has been taken for granted since the discovery of the fibreoptic bundle and the advent of fibreoptic endoscopy. Fibreoptic and lens assemblies can distort the impression of colour by selectively absorbing some wavelengths of light. In the case of electronic endoscopes, the principal sensor is the charge-coupled device (CCD), a small microelectronic device that converts an image into a sequence of electronic signals which, after appropriate processing, are transformed into an image on the monitor screen. The image is therefore visualized as a mosaic of small images, one from each sensing element. Colour is synthesized by using sequential illumination using filters or by filters placed over the CCD. Fibre-endoscopes may alter colour by selectively transmitting certain portions of the visible spectrum, while electronic endoscopes are susceptible to errors due to poor calibration of the instrument and manipulation of the colour controls by endoscopists. Colour information provides the endoscopist with clues to the nature of the lesion and also a site for biopsy. In experimental situations, colour information has been used to determine blood flow and classify lesions. Much work needs to be done to define normal and abnormal colour in the gastrointestinal tract and to develop a standard terminology for colour nomenclature in endoscopy.

Color Perception↗

The importance of rigid nasal endoscopy in the diagnosis and treatment of rhinolithiasis.

OBJECTIVES: Rhinolithiasis is the presence of mineralized and calcareous formations located in the nasal cavity. They have rare occurrence and can be easily confused with infection or obstruction of upper airways. If they are undetected for a long time, they may grow large enough to cause of nasal obstruction, mimicking sinusitis. Seven cases of rhinolithiasis were presented, and their diagnosis was made by rigid endoscopic nasal examination. Also computerized tomography scan was used to describe the size and site of the rhinoliths accurately. Our purpose was to determine the role of rigid nasal endoscopy in the diagnosis and the treatment of rhinolithiasis. METHODS: In this study, seven cases of rhinolithiasis, who were diagnosed and treated by rigid nasal endoscopy were presented. RESULTS: Between January 2000 and November 2004, seven cases (four males and three females; age ranged from 8 to 45 years) with rhinolithiasis were diagnosed. The most frequent symptoms were nasal obstruction with purulent rhinorhea, nasal and oral malodor. As complementary examinations, computerized tomography and simple X-ray of paranasal sinuses were used to locate and measure the dimension of calcareous mass, and to reveal possible invasion of the adjacent structures. The removal of rhinolithiasis was done with rigid nasal endoscopy under topical anesthesia in six cases and general anesthesia in one case. CONCLUSION: Rhinolithiasis is a rare condition but must always be suspected in patients with long standing nasal obstruction, nasal and oral malodor, purulent rhinorrhea and chronic headache.

Adolescent↗

[Interventional digestive endoscopy in pediatrics].

Interventional endoscopy concerns the therapeutic acts carried out by endoscopic way at the level of the digestive tract. It is realized under general anaesthesia and it has profited from recent progress of the material (endoscopes and accessories). Some acts are realized in a current way in paediatrics: extraction of foreign body, dilation of oesophageal stenosis, gastrostomy. Other indications are rarer. In these cases, interventional endoscopy is usually done with the collaboration of the adult endoscopists, whose field of activity in interventional endoscopy is far much broader.

Catheterization↗

Endoscopy-assisted ultrasonic surgical aspiration of axillary osmidrosis: a retrospective review of 896 consecutive patients from 1998 to 2004.

Axillary osmidrosis is a distressing and troublesome problem that causes a serious handicap in personal and social life. Many different methods have been introduced to treat axillary osmidrosis, however, they are often accompanied by marked complications. We analysed our experiences using endoscopy-assisted ultrasonic surgical aspiration in treating the axillary osmidrosis. From June 1998 to February 2004, a total of 896 patients (562 females, 334 males) were treated for axillary osmidrosis using endoscopy-assisted ultrasonic surgical aspiration. Our method was satisfactory in 815 patients (91%) and recurrence of odour occurred only in 29 (3.2%) patients. It also showed complications in 28 (3.1%) patients. Our method leaves a small inconspicuous scar and no contracture of the axillary skin after a short and comfortable recovery period and maintains normal axillary hair growth patterns. Axillary osmidrosis can be best treated by endoscopy-assisted ultrasonic surgical aspiration and this operation has many advantages with a high success rate, a low complication rate, and a rapid recovery period.

Adolescent↗

Capsule endoscopy in 2005: facts and perspectives.

Capsule endoscopy has recently been introduced to explore endoscopically the whole small intestine, fulfilling a gap between examinations of the upper and lower gastrointestinal tract. The technique consists of a miniaturized endoscope, embedded in a swallowable capsule that is propulsed by peristalsis and achieves the journey to the right colon in five to eight hours. Images captured by the capsule are recorded on a hard drive worn in a belt by the patient. The main indication for capsule examination is the examination of the small bowel to find a bleeding lesion in patients with obscure bleeding. Several studies have shown that the diagnostic yield of capsule endoscopy is superior to that of push enteroscopy in this indication. Other possible indications are patients with suspected intestinal location of Crohn's disease, familial adenomatous polyposis, complicated coeliac disease and lesions due NSAIDs. The review contains information on the technical aspects of capsule endoscopy and discusses the indications. Issues of safety and tolerance are also discussed.

Capsules↗

Double-balloon endoscopy for the diagnosis and treatment of small intestinal disease.

Evaluation of the small bowel has long been hampered because of its long and multiple complex loop configurations. Yamamoto et al have developed a new method of inserting an endoscope, known as the double-balloon method of enteroscopy, the Fujinon double-balloon endoscopy system being specialised for this application. Two types of endoscope are currently available for this technique. The EN-450 P5 is a thin endoscope for regular use, whereas the EN-450 T5 is a therapeutic double-balloon endoscope with a larger accessory channel of 2.8mm in diameter. Double-balloon endoscopy enables visualisation of the entire small bowel and also allows for interventional therapy in the small intestine. This method can be used either from an oral or an anal insertion. Observation of an affected area with controlled movement of the endoscope enables interventions, including biopsies, haemostasis, balloon dilatation, stent placement, polypectomy and endoscopic mucosal resection, to be performed. In our large study series, it was demonstrated that double-balloon endoscopy permitted exploration of the small intestine with the high success rate of total enteroscopy. The procedure is safe and useful, and it provides high diagnostic yields and therapeutic capabilities.

Clinical Trials as Topic↗